At least 55 records · Page 3

SU-F-I-72: Evaluation of the Ancillary Lead Shielding for Optimizing Radiation Protection in the Interventional Radiology Department

Purpose: The rising complexity of interventional fluoroscopic procedures has resulted in an increase of occupational radiation exposures in the interventional radiology (IR) department. This study assessed the impact of ancillary shielding on optimizing radiation protection for the IR staff. Methods: Scattered radiation measurements were performed in two IR suites equipped with Axiom Artis systems (Siemens Healthcare, Erlangen, Germany) installed in 2006 and 2010. Both rooms had suspended ceiling-mounted lead-acrylic shields of 75×60 cm (Mavig, Munich, Germany) with lead equivalency of 0.5 mm, and under-table drapes of 70×116 cm and 65×70 cm in the newer and the older room respectively. The larger skirt can be wrapped around the table’s corner and in addition the newer suite had two upper shields of 25×55 cm and 25×35 cm. The patient was simulated by 30 cm of acrylic, air kerma rate (AKR) was measured with the 180cc ionization chamber (AccuPro Radcal Corporation, Monrovia, CA, USA) at different positions. The ancillary shields, x-ray tube, image detector, and table height were adjusted by the IR radiologist to simulate various clinical setups. The same exposure parameters were used for all acquisitions. AKR measurements were made at different positions relative to the operator. Results: The AKR measurements demonstrated 91–99% x-ray attenuation by the drapes in both suites. The smaller size of the under-table skirt and absence of the side-drapes in the older room resulted in a 20–50 fold increase of scattered radiation to the operator. The mobile suspended lead-acrylic shield reduced AKR by 90–94% measured at 150–170 cm height. The recommendations were made to replace the smaller under-table skirt and to use the ceiling-mounted shields for all IR procedures. Conclusion: The ancillary shielding may significantly affect radiation exposure to the IR staff. The use of suspended ceiling-mounted shields is especially important for reduction of interventional radiologists’ cranial radiation.

60 APPLIED LIFE SCIENCES↗

Injection Beam Loss Monitor for NSLS-II Radiation Protection

The NSLS-II with its high stored beam energy operation and top-off injection, make the radiation protection a critical issue. The radiation shield wall of the tunnel is being designed to be adequate for a 10% loss of the injection current (l.4nC/min) at any one location. The injection region is shielded for 100% injection losses (14nC/min). This thinner shielding around the ring is a concern should the beam develop high current instabilities, that would cause the beam to dump or develop a very short lifetime. In order to overcome these instabilities, studies and operations in the high current conditions that might drive these instabilities would be required. If the radiation shielding would not allow operation at these currents, then the ability to study and correct these instabilities may not be allowed or at least not without greatly restriction the users access to the experimental floor. We propose a detector that could be used to quantify the amount of charge (DC current) lost around the ring, verifying that beam losses didn't exceed the design levels. This would then allow the beam to be refilled for operations and/or studies without regard to the experimental floor occupancy. In a earlier Tech Note we proposed a method to control the location of the beam dumped during intentional (interlock trips) and unintentional beam losses, this Tech Note will deal mostly with accounting for beam lost during injection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pregnancy and Radiation Protection

Several modalities are currently utilized for diagnosis and therapy, by appropriate application of x-rays. In diagnostic radiology, interventional radiology, radiotherapy, interventional cardiology, nuclear medicine and other specialties radiation protection of a pregnant woman as a patient, as well as a member of the operating personnel, is of outmost importance. Based on radiation risk, the termination of pregnancy is not justified if foetal doses are below 100 mGy. For foetal doses between 100 and 500 mGy, a decision is reached on a case by case basis. In Diagnostic Radiology, when a pregnant patient takes an abdomen CT, then an estimation of the foetus' dose is necessary. However, it is extremely rare for the dose to be high enough to justify an abortion. Radiographs of the chest and extremities can be done at any period of pregnancy, provided that the equipment is functioning properly. Usually, the radiation risk is lower than the risk of not undergoing a radiological examination. Radiation exposure in uterus from diagnostic radiological examinations is unlikely to result in any deleterious effect on the child, but the possibility of a radiation-induced effect can not be entirely ruled out. The effects of exposure to radiation on the foetus depend on the time of exposure, the date of conception and the absorbed dose. Finally, a pregnant worker can continue working in an x-ray department, as long as there is reasonable assurance that the foetal dose can be kept below 1 mGy during the pregnancy. Nuclear Medicine diagnostic examinations using short-lived radionuclides can be used for pregnant patient. Irradiation of the foetus results from placental transfer and distribution of radiopharmaceuticals in the foetal tissues, as well as from external irradiation from radioactivity in the mother's organ and tissues. As a rule, a pregnant patient should not undergo therapy with radionuclide, unless it is crucial for her life. In Radiotherapy, the patient, treating oncologist, other team and family members should carefully discuss for the decision of abortion. Important factors must be considered such as the stage and aggressiveness of the tumour, the location of the tumour, the stage of pregnancy, various therapies etc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection Considerations at USACE Formerly Utilized Sites Remedial Action Program (FUSRAP) Projects

The Formerly Utilized Sites Remedial Action Program (FUSRAP) was initially authorized by Congress in 1974. FUSRAP was enacted to address residual radioactive contamination associated with numerous sites across the U.S. at which radioactive material (primarily Uranium ores and related milling products) had been processed in support of the nation's nuclear weapons program dating back to the Manhattan Project and the period immediately following World War II. In October 1997, Congress transferred the management of this program from the Department of Energy to the United States Corp of Engineers. Through this program, the Corps addresses the environmental remediation of certain sites once used by DOE's predecessor agencies, the Manhattan Engineer District and the Atomic Energy Commission. The waste at FUSRAP sites consists mainly of low levels of uranium, thorium and radium, along with some mixed wastes. Upon completion of remedial activities, these sites are transferred to DOE for long-term stewardship activities. This paper presents and contrasts the radiological conditions and recent monitoring results associated with five large ongoing FUSRAP projects including Maywood, N.J.; the Linde site near Buffalo, N.Y.; Colonie in Albany N.Y. and the St Louis, Mo. airport and downtown sites. The radiological characteristics of soil and debris at each site and respective regulatory clean up criteria is presented and contrasted. Some differences are discussed in the radiological characteristics of material at some sites that result in variations in radiation protection monitoring programs. Additionally, summary data for typical personnel radiation exposure monitoring results are presented. In summary: 1. The FUSRAP projects for which data and observations are reported in this paper are considered typical of the radiological nature of FUSRAP sites in general. 2. These sites are characterized by naturally occurring uranium and thorium series radionuclides in soil and debris, at concentrations typically < E4 pCi/ gram total activity. 3. Although external exposure rates are generally low resulting in few exposures above background, occasional 'hot spots' are observed in the 1- 10 mR / hr range or higher. However personnel and general area external exposure monitoring programs consistently demonstrate very low potential for external exposure at theses sites. 4. Potential for airborne exposure is controlled by wetting and misting techniques during excavation and movement of materials. Air sampling and bioassay programs confirm low potential for airborne exposure of workers at these sites. 5. Radiation protection and health physics monitoring programs as implemented at these sites ensure that exposures to personal are maintained ALARA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation Protection Studies for LCLS Tune Up Dump

The Linac Coherent Light Source (LCLS) at the Stanford Linear Accelerator Center is a pioneer fourth generation hard x-ray free electron laser that shall start to deliver laser pulses in 2009. Among other components of LCLS that present radiation protection concerns, the tune up dump (tdund) is of special interest because it also constitutes an issue for machine protection, as it is placed close to radiation sensitive components, like electronic devices and permanent magnets in the undulators. This paper first introduces the stopper of tdund looking at the heat load, and then it describes the shielding around the dump necessary to maintain the prompt and residual dose within design values. Next, preliminary comparisons of the magnetization loss in a dedicated on-site magnet irradiation experiment with FLUKA simulations serve to characterize the magnetic response to radiation of magnets like those of LCLS. The previous knowledge, together with the limit for the allowed demagnetization, are used to estimate the lifetime of the undulator. Further simulations provide guidelines on which lifetime can be expected for an electronic device placed at a given distance of tdund.

43 PARTICLE ACCELERATORS↗

Radiation Protection Methods for the Interventionalist’s Hands: Use of an Extension Tube

PurposeCumulative radiation exposure to the hands during certain interventional procedures may be high. It is important to decrease the amount of radiation to the operator due to the possibility of deterministic effects. We performed a pilot study to demonstrate a significant decrease in operator dose when using extension tubing (ET) in combination with shielding and collimation during a simulated percutaneous transhepatic cholangiogram (PTC) procedure.MethodsA whole body, anthropomorphic phantom was used to simulate the patient. A Unfors-Xi Survey detector (to measure scatter) supported by a retort stand and trolley was placed in various positions to simulate the position of hands and eyes/thyroid of an interventionalist. Radiation dose was measured simulating left and right-sided PTC punctures with and without a lead shield, and with and without ET.ResultsRegarding the radiation dose to the hands; the use of an ET reduces dose by 54 % in right-sided PTC punctures without a shield and by 91 % if used in combination with a shield. For left-sided PTC punctures, ET reduces hand dose by 75 %. The use of collimation decreases hand dose by approximately 60 %. The use of shielding reduces dose to the eyes/thyroid by 98 %.ConclusionsThe dose to the hands can be significantly reduced with the appropriate use of a shield, ET, and tight collimation. The use of a shield is paramount to reduce dose to the eyes/thyroid. It is important for interventionalists to adhere to radiation protective practice considering the potential deterministic effects during a lifelong career.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations for NSLS-II Synchrotron Radiation Protection When Operating Damping Wigglers at Low Machine Energy

The NSLS-II storage ring vacuum chamber, including frontends (FE) and beamlines (BL), is protected from possible damage from synchrotron radiation (SR) emitted from insertion devices (IDs) by a dedicated active interlock system (AIS). The system monitors electron beam position and angle and triggers a beam dump if the beam orbit is outside of the active interlock envelope (AIE). The AIE was calculated under the assumptions of 3 GeV beam energy and ID gaps set to their minimum operating values (i.e. “fully closed”). Recently it was proposed to perform machine studies that would ramp the stored beam energy significantly below the nominal operational value of 3 GeV. These studies may potentially include the use of NSLS-II damping wigglers (DWs) for electron beam emittance reduction and control. These DWs have the minimum operating gap of g min =15 mm with the corresponding peak magnetic field B 0 =1.8 T. During regular machine operations or studies at 3 GeV, DWs are usually held at this minimum gap (thus maximum field), or, alternatively, they are fully opened to the gap of 150 mm, which corresponds to a negligible residual magnetic field. However, any intermediate values of wiggler gap can be easily set through the control system with micron level precision, so wiggler fields in the range of 0< B < B 0 can be precisely set and maintained. For the low energy studies two likely modes of DW operation must be considered: 1) the maximum allowable wiggler filed is proportional to the storage ring energy, B ( E )= B 0 E /E 0 ; and 2) the maximum allowable wiggler field (and thus the minimum allowable gap) is energy independent and is equal to its nominal 3 GeV value of 1.8 T (i.e. wiggler gap is fixed at 15 mm). The aim of this technical note is to consider the synchrotron radiation protection (SRP) implications of DW use during low energy machine studies, when DWs are operated in either of these two modes. For consistency with earlier SRP documents we will quote all the powers and power densities at the nominal NSLS-II design beam current of 500 mA, even though the low energy studies will be done at significantly lower beam currents, hence the SR power will be proportionally smaller.

36 MATERIALS SCIENCE↗

National Council on Radiation Protection (NCRP) 2024 annual meeting: advanced and small modular nuclear power reactors

On 25–26 March 2023, the U.S. National Council on Radiation Protection and Measurements (NCRP) held its 2024 annual meeting in Bethesda, Maryland, USA. The NCRP dates from 1929, and this meeting celebrated the 60th anniversary of receiving a U.S. Congressional Charter. For this annual meeting the NCRP felt it was essential to provide a briefing about advanced and small modular nuclear reactors (SMRs). The Journal of Radiological Protection is delighted to publish the following synopsis of material presented at the U.S. NCRP meeting. This synopsis is divided into five sections. The first section provides an overview of the whole meeting together with summaries of two context setting overview papers. The following four sessions of this synopsis are specific to advanced and small modular nuclear power reactors. The meeting also included keynote presentations by three of NCRP annual award recipients. The meeting topical areas were Technology Overview and Critical Issues. The individual papers laid the groundwork to understanding reactor technologies, terminology, and the fundamental concepts and processes for electrical generation. The perspectives of the U.S. Environmental Protection Agency and states, through the Conference of Radiation Control Program Directors were provided. The papers included a discussion of diverse topics including potential emergency preparedness considerations, radiological survey requirements, an evaluation of the future of nuclear power, the economics of reactors (both large and small), and the critical issues identified by the recent National Academies of Sciences’ study on advanced reactors. Here, the summary papers were developed to briefly document the major points and concepts presented during the oral papers presented at the 2024 NCRP Annual Meeting. The meeting heralded the dawn of a new era for commercial nuclear power.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection Aspects of the SPES Project at LNL

The SPES (Selective Production of Exotic Species) project will be built at the National Laboratories in Legnaro (Italy) of the National Institute of Nuclear Physics (INFN). Its goal will be the development of radioactive ion beams and the consequent re-acceleration with the existing linac to perform forefront research in nuclear physics. Radiation protection aspects are being considered at every stage of the project, e.g. civil construction planning, control system design and special technological plants. These aspects have been studied with the Monte Carlo transport code FLUKA and are presented in this paper.

43 PARTICLE ACCELERATORS↗

2013 Caliban and Prospero experiments for the study of the behavior of radiation protection instrumentations in case of a criticality accident - 14346

Experiments using the CALIBAN and PROSPERO reactors were performed in 2013 in the framework of a collaboration between IRSN and CEA. The objective was to provide data about the possibility to use information given by radiation protection instrumentations (RPI) in the case of a criticality accident. In that purpose, the behavior of RPI was studied for various kinetics of the reactors which simulated different starts of a criticality accident. The article presents the safety issues associated with these experiments, i.e. the possible use of information given by the RPI for the emergency response of a criticality accident (detection of the accident, triage of the personnel, follow-up of the accident and reentry). Then, one paragraph is dedicated to the presentation of the tested material. In addition, the CALIBAN and PROSPERO reactors are briefly described, followed by the performed experiments. The RPI are neither designed nor dedicated to be used in case of a criticality accident. However, the preliminary conclusion of the experiments performed in 2013 is that the tested RPI have a correct behavior for slow kinetic experiments performed with the PROSPERO reactor, but might give less reliable and accurate information for pulse experiments performed with the CALIBAN reactor. In the last case, they can nevertheless provide information that can be helpful for the emergency response and the limitation of the consequences of the criticality accident. However, if the RPI are included in the emergency response of a criticality accident (detection, triage, follow-up, reentry), emergency procedures should be adapted. Other experiments might be performed in order to confirm results and to extend the number of tested materials, in particular portable survey meters or contamination area monitors. (authors)

42 ENGINEERING↗

Active Scraper and Beam Dump for NSLS-ll Radiation Protection

The NSLS-II with its high stored beam energy operation and top-off injection, makes the radiation protection a critical issue. The radiation shield wall of the tunnel is being designed to be adequate for a 5% loss of the top-off injection current at one point in the ring. However, the injection region is shielded for 100% injection losses. This weaker shielding around the ring is a critical concern should the beam develop high current instabilities, that would cause the beam to dump or develop a very short lifetime. In order to overcome these instabilities, studies and operations in the high current conditions that might drive these instabilities would be required. If the radiation shielding would not allow this operation at these currents, should the entire beam be lost at an arbitrary point around the lattice, then the ability to study and correct these instabilities may not be allowed or at least not without greatly restriction the users access to the experimental floor.

36 MATERIALS SCIENCE↗

Reflections on the impact of advances in the assessment of genetic risks of exposure to ionizing radiation on international radiation protection recommendations between the mid-1950s and the present

Efforts at protecting people against the harmful effects of radiation had their beginnings in the early 1900s with the intent of protecting individuals in medicine and associated professions. Such efforts remain vital for all of us more than 100 years later as part of our 'learning to live with ionizing radiation.' The field of radiation protection has evolved slowly over time with advances in knowledge on hereditary (i.e., genetic) and carcinogenic effects of radiation continually improving our ability to make informed judgments about how best to balance risks against benefits of radiation exposure. This paper examines just one aspect of these efforts, namely, how advances in knowledge of genetic effects of radiation have impacted on the recommendations of the International Commission on Radiological Protection (ICRP). The focus is on the period from the mid-1950s (when genetic risk estimates were first made) to 2007. This article offers a detailed historical analysis and personal perspective, and concludes with a synopsis of key developments in radiation protection.

59 BASIC BIOLOGICAL SCIENCES↗

Commissioning of the synchrotron radiation protection system and beamlines frontends at NSLS-II

The first eight insertion devices (IDs) at the NSLS-II were commissioned during the fall run of 2014. In this paper we discuss commissioning of the synchrotron radiation protection (SRP) system and beamline frontends (FE) for the respective IDs. We describe the diagnostics utilized if FE commissioning and a procedure that was used for the alignment of the photon beam from insertion devices in the beamline frontends. Then we discuss the current status of the SRP system and operation of the commissioned frontends.

43 PARTICLE ACCELERATORS↗

Operational Radiation Protection in Synchrotron Light and Free Electron Laser Facilities

The 3rd generation synchrotron radiation (SR) facilities are storage ring based facilities with many insertion devices and photon beamlines, and have low injection beam power (< few tens of watts), but extremely high stored beam power ({approx} 1 GW). The 4th generation x-ray free electron laser (FEL) facilities are based on an electron Linac with a long undulator and have high injection beam power (a few kW). Due to its electron and photon beam characteristics and modes of operation, storage ring and photon beamlines have unique safety aspects, which are the main subjects of this paper. The shielding design limits, operational modes, and beam losses are first reviewed. Shielding analysis (source terms and methodologies) and interlocked safety systems for storage ring and photon beamlines (including SR and gas bremsstrahlung) are described. Specific safety issues for storage ring top-off injection operation and FEL facilities are discussed. The operational safety program, e.g., operation authorization, commissioning, training, and radiation measurements, for SR facilities is also presented.

43 PARTICLE ACCELERATORS↗

Options for Providing Radiation Protection Shelter Quality Information to U.S. Local, State and Federal Government Agencies

This report describes available information on protection that can be provided by buildings from exposure to radioactive contamination in the environment, and options for how this information can be provided to government organizations across the United States. This information is potentially useful for planning how to protect the public in the event of an atmospheric release of radioactivity including, for example, from a Radiological Dispersal Device, an Improvised Nuclear Device detonation, or a Nuclear Power Plant accident. During these incidents, knowledge of the radiation protection provided by buildings is critical to predicting and assessing radiation dose to the population, and the associated health risk. These dose assessments inform emergency plans and decisions including, for example, identifying areas in which people should be sheltered in place, and determining when controlled population evacuations should be made.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation on radiation protection aspect and radiological risk at Mukim Belanja repository

Asian Rare Earth (ARE) is a locally incorporated company that operated a mineral processing operation to extract rare earth element. ARE has received much attention from the public since the beginning of their operation until the work of decommissioning and decontamination of the plant. Due to the existence of Naturally Occurring Radioactive Material (NORM) in the residue, the decommissioning and disposal was done by the company in collaboration with the Perak State Government and the Atomic Energy Licensing Board (AELB). The main objective of this study is to review the level of compliance of the existing Radiation Protection Regulations enforced by AELB particularly in the achievement of allowed exposure dose limit. The next objective was to study the impact of the construction of the Mukim Belanja Repository to workers and public. This study was conducted by analyzing documents that were issued and conducting the area monitoring using a Geiger Muller detector (GM) and Sodium Iodide (NaI(Tl)) survey meters. The measurements were made at 5 cm and 1 m from the ground surface at 27 measurement stations. The external doses measured were within the background levels of the surrounding area. The annual effective dose using the highest reading at 5 cm and 1 m from ground surface by GM detector was calculated to be 1.36 mSv/year and 1.21 mSv/year respectively. Whereas the annual effective dose using the highest reading at 5 cm and 1 m from ground surface by using NaI(Tl) detector was calculated to be 3.31 mSv/year and 2.83 mSv/year respectively. The calculated cancer risks from the study showed that the risk is small compared with the risks derived from natural radiation based on global annual radiation dose to humans. This study therefore indicated that the repository is able to constrain the dose exposure from the disposed NORM waste. The study also revealed that the construction of the repository has complied with all the rules and regulations subjected to it. The exposed dose received by the radiation and the public workers during the construction of the repository were below the annual limit i.e. 20 mSv/year and 1mSv/year respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection for the First Korea Heavy-ion Medical Accelerator (KHIMA) Facility - Paper 7

The number of particle therapy facilities is increasing worldwide due to the encouraging results obtained at research facilities such as the Lawrence Berkeley National Laboratory (USA), the Helmholtz Center for Heavy Ion Research GSI (Germany), and the Heavy Ion Medical Accelerator (HIMAC) in Chiba (Japan). The first hospital-based heavy-ion therapy facility is under construction in Busan, Korea, at the Korea Institute of Radiological and Medical Sciences [KIRAMS]. The project was originally designed to develop a compact superconducting cyclotron for hadron therapy able to deliver forefront beams of heavier ions, essentially carbon ions of energy, 430 MeV/u. Radiation protection issues play an important role in every stage of the project such as civil construction planning, control system design, and special technological plants. Monte Carlo transport codes are the best tools to solve these issues and the FLUKA2011 and MCNPX2.7.0 codes are used in this work. Beam loss distributions of cyclotron installations in combination with passive or active beam shaping methods have a particularly high implication on the protection layout of the facility. Methods for shielding and activation calculations are described with an emphasis on carbon ion beams. All the tools and databases require verification. Benchmarking is an instrumental process for verification. An overview of benchmarking efforts will also be given and the need for further benchmarks is discussed. (authors)

43 PARTICLE ACCELERATORS↗

SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm{sup 2} opening, while the remaining length has a 30×30 cm{sup 2} opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm{sup 2} opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

07 ISOTOPE AND RADIATION SOURCES↗