At least 55 records · Page 3

Optimizing long-term monitoring of radiation air-dose rates after the Fukushima Daiichi Nuclear Power Plant

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (FDNPP) have been steadily decreasing over the past eight years since the release of radioactive elements in March 2011. Currently, the radiation monitoring program is expected to transition to long-term monitoring after most of the remediation activities are completed. The main long-term monitoring objectives are to (1) confirm the continuing reduction of contaminant and hazard levels, (2) provide assurance for the public, (3) accumulate the basic datasets for scientific knowledge and future preparation, and (4) detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the monitoring locations of radiation air dose-rate monitoring. Our approach consists of three steps in order to determine monitoring locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations that cover the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air-dose rates across the domain. Therefore, for the second step, we use a Gaussian mixture model to identify the representative locations among multiple environmental variables, such as elevation and land-cover types. For the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air-dose rates across the domain. Employing an integrated dose-rate map derived from Bayesian geostatistical methods as a reference map, we distribute the monitoring locations in such a way as to capture the heterogeneity of the reference map. Our results have shown that this approach allows us to select monitoring locations in a systematic manner such that the heterogeneity of air dose rates is captured by the minimal number of monitoring locations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of synoptic scale moisture and wind field analyses using the Nimbus 4 THIR 6.7 micron observations

The Nimbus 4 temperature-humidity infrared radiometer (THIR) monitors radiation in the 6.5 to 7.2 micron water vapor absorption with a 23 kilometer spatial resolution at the sub-satellite point. Radiation monitored in this spectral region results primarily from emission in the 250 to 500 millibar region of the upper troposphere. The THIR 6.7 micron observations are readily available in photofacsimile imagery form which shows very distinctive patterns associated with spatial variations in atmospheric water vapor. These radiometric observations were combined in several instances with moisture values measured in the upper troposphere by the standard radiosonde network. In each instance, the result is a much more consistent analysis showing increased spatial detail that agrees with the radiometric observations and does not compromise the conventional data. The improved moisture analyses show relatively dry and moist tongues that are very difficult or impossible to infer from the conventional data alone. The patterns in the moisture fields can be tracked over 12 and 24 hour periods. In addition, by keeping in mind the advective properties of the moisture field, success was achieved in improving streamline analyses at the 400 mb level over data sparse regions on a global scale.

Steranko, J.↗

Application of Nimbus 4 THIR 6.7-micron observations to regional and global moisture and wind field analyses.

The Nimbus 4 temperature-humidity infrared radiometer (THIR) monitors radiation in the 6.5 to 7.2-micron water vapor absorption region with a 23-km spatial resolution at the subsatellite point. Radiation monitored in this spectral region results primarily from emission in the 250 to 500-mb region of the upper troposphere. The THIR 6.7-micron observations are readily available in photofacsimile imagery form which shows very distinctive patterns associated with spatial variations in atmospheric water vapor. These radiometric observations have been combined in several instances with moisture values measured in the upper troposphere by the standard radiosonde network. In each instance, the result is a much more consistent analysis showing increased spatial detail that agrees with the radiometric observations and does not compromise the conventional data. The improved moisture analyses show relatively dry and moist tongues that are very difficult or impossible to infer from the conventional data alone.

Steranka, J.↗

Life Sciences and Space Research 25 (2) Radiation Biology: Topical Meeting of the COSPAR Interdisciplinary Scientific Commission F of the COSPAR 29th Plenary Meeting, Washington, DC, Aug. 28-Sep. 5, 1992

Papers presented on long-term exposure to ionizing radiation, obtained from the Long Duration Exposure Facility, included radiation monitoring, radiation effects, and dosimetry. Mechanisms of biological systems, especially cells, under ionizing radiation and relative biological effectiveness were compared. The role of HZE particles as agents of mutation were reported from plant, animal, and in vitro models. Data on known and predicted effects of cosmic rays and other solar radiation on biological systems included differences related to Linear Energy Transfer and heavy ion particles.

Horneck, G.↗

Humanoid Flight Metabolic Simulator Project

NASA's Evolvable Mars Campaign (EMC) has identified several areas of technology that will require significant improvements in terms of performance, capacity, and efficiency, in order to make a manned mission to Mars possible. These include crew vehicle Environmental Control and Life Support System (ECLSS), EVA suit Portable Life Support System (PLSS) and Information Systems, autonomous environmental monitoring, radiation exposure monitoring and protection, and vehicle thermal control systems (TCS). (MADMACS) in a Suit can be configured to simulate human metabolism, consuming crew resources (oxygen) in the process. In addition to providing support for testing Life Support on unmanned flights, MADMACS will also support testing of suit thermal controls, and monitor radiation exposure, body zone temperatures, moisture, and loads.

Ross, Stuart↗

Minimum Detectable Quantity Calculation for Radiation Portal Monitors

The minimum detectable quantity of a radiation portal monitor is the smallest amount of radioactive material that can be detected passing through the monitor (with a specified detection probability). The minimum detectable quantity is a function of many factors, including isotope, velocity, distance between pillars, height of portal and vehicle, source distribution and position, background radiation, background suppression, detector volume and positions, detector efficiency, decision metrics and algorithms, the presence of NORM (naturally occurring radioactive material), and alarm thresholds. Experimentally testing a radiation portal monitor to failure for all combinations of these factors is extremely time-consuming and often cost prohibitive. This document outlines a straightforward method for quickly estimating the minimum detectable quantity for moving sources over a large variety of conditions with a minimal number of static measurements. The document also describes a proof of concept software application that the International Atomic Energy Agency has designed based on the described method that can be used by Member States to estimate a monitor’s minimum detectable quantity.

Blessinger, Christopher S.↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

A radiation belt monitor for the High Energy Transient Experiment Satellite

A Radiation Belt Monitor (RBM) sensitive to protons and electrons with energy approximately greater than 0.5 MeV has been designed for the High Energy Transient Experiment (HETE) satellite in order to: first, control the on-off configuration of the experiments (i.e. those susceptible to proton damage); and second, to indicate the presence of proton and/or electron events that could masquerade as legitimate high energy photon events. One of the two RBM channels has an enhanced sensitivity to electrons. Each channel of the RBM, based on a PIN silicon diode, requires a typical power of 6 milliwatts. Tests have been performed with protons with energies from approximately 0.1 to 2.5 MeV (generated by a Cockcroft-Walton linear accelerator via the d(d,p)t reaction), and with electrons with energies up to 1 MeV (from a 1.0 microcurie Bi-207 source).

Lo, D. H.↗