Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RSI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Reusable Surface Insulation (RSI) Material Samples

Test specimen data sheets are presented for 48 high temperature and 40 low temperature reusable surface insulation tiles. Tabular data show dimensions, density, coating weight, and final tile weight. Codes indicate basic material, surface coating, and hydrophobic treatment.

Banas, R. P.↗

Adhesives for bonding RSI tile to Gr/Pi structure for advanced space transportation systems

An adhesive was developed having improved high-temperature capability while retaining the ideal processing characteristics of RTV silicones. After evaluating several possibilities, mixtures of RTV with glass resins were selected as most promising. While results are not conclusive, tests of the final mixture evaluated, designated RA59, indicated capability of performing as a tile bonding agent to temperatures approaching 370C (700F) during repeated cycling.

Smith, K. E.↗

Integration of a Radiosensitivity Molecular Signature Into the Assessment of Local Recurrence Risk in Breast Cancer

Purpose: Recently, we developed radiosensitivity (RSI), a clinically validated molecular signature that estimates tumor radiosensitivity. In the present study, we tested whether integrating RSI with the molecular subtype refines the classification of local recurrence (LR) risk in breast cancer. Methods and Materials: RSI and molecular subtype were evaluated in 343 patients treated with breast-conserving therapy that included whole-breast radiation therapy with or without a tumor bed boost (dose range 45-72 Gy). The follow-up period for patients without recurrence was 10 years. The clinical endpoint was LR-free survival. Results: Although RSI did not uniformly predict for LR across the entire cohort, combining RSI and the molecular subtype identified a subpopulation with an increased risk of LR: triple negative (TN) and radioresistant (reference TN-radioresistant, hazard ratio [HR] 0.37, 95% confidence interval [CI] 0.15-0.92, P=.02). TN patients who were RSI-sensitive/intermediate had LR rates similar to those of luminal (LUM) patients (HR 0.86, 95% CI 0.47-1.57, P=.63). On multivariate analysis, combined RSI and molecular subtype (P=.004) and age (P=.001) were the most significant predictors of LR. In contrast, integrating RSI into the LUM subtype did not identify additional risk groups. We hypothesized that radiation dose escalation was affecting radioresistance in the LUM subtype and serving as a confounder. An increased radiation dose decreased LR only in the luminal-resistant (LUM-R) subset (HR 0.23, 95% CI 0.05-0.98, P=.03). On multivariate analysis, the radiation dose was an independent variable only in the LUMA/B-RR subset (HR 0.025, 95% CI 0.001-0.946, P=.046), along with age (P=.008), T stage (P=.004), and chemotherapy (P=.008). Conclusions: The combined molecular subtype–RSI identified a novel molecular subpopulation (TN and radioresistant) with an increased risk of LR after breast-conserving therapy. We propose that the combination of RSI and molecular subtype could be useful in guiding radiation therapy–based decisions in breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-615: Comparison of Plan Quality for Linac-Based Stereotactic Radiosurgery (SRS) Using Single- and Multi-Isocenter Techniques

Purpose: To compare the plan quality of linear accelerator (linac)-based stereotactic radiosurgery (SRS) using single-isocenter volumetric arc therapy (SI-VMAT), restricted single-isocenter dynamic-arc (RSI-DARC), and multi-isocenter DARC (MI-DARC) techniques. Methods: Fifteen SRS cases were randomly selected and re-planned using the SI-VMAT (Pinnacle), RSI-DARC (iPlanNet) and MI-DARC (iPlanNet). The number of planning target volumes (PTVs) for each plan ranged from 1 to 6. For SI-VMAT, a single isocenter and 3-4 VMAT beams are used for all PTVs, while for MI-DARC, each PTV has its own isocetner with 3 DARC beams. RSI-DARC uses one isocnter with 3-6 DARC beams to irradiate all PTVs within 2.5-cm radius. Both SI-DARC and RSI-DARC plans were optimized manually. The prescription dose was 20 Gy to each PTV. The maximal dose was 25 Gy for RSI-DARC and MI-DARC, but could not be controlled for SI-VMAT due to the nature of VMAT planning. Plan quality indexes including PTV coverage, mean dose of PTV (PTVmean) and tissue (Tmean), V12Gy, conformity index (CI), and V10Gy/VPTV were calculated and compared. Results: Full PTV coverage was achieved for all three techniques. Using the MI-DARC plans as the gold standard, the PTVmean of the SI-VMAT plans was 12.5%±8.3% (mean±standard deviation) higher, in comparison to 0.7%±1.4% for the RSI-DARC plans. Similar trend was observed for other indexes including V12Gy (39.4%±27.3% vs. 9.3%±7.8%), Tmean (35.0%±26.8% vs. 2.8%±3.4%), and V10Gy/VPTV (42.2%±31.5% vs. 9.9%±8.2%). CI is comparable (6.2%±14.2% vs. 6.3%±7.2%). Assuming the treatment time is proportional to the number of isocenters, the reduction of the treatment time in comparison to MI-DARC was 70% for SI-VMAT and 42% for RSI-DARC. Conclusion: Although the SI-VMAT can save a considerable amount of treatment time, the plan indexes also significantly deviates from the gold standard, MI-DARC. RSI-DARC, on the other hand, provides a good compromise between the treatment time and plan quality.

60 APPLIED LIFE SCIENCES↗

Thermal performance of a mechanically attached ablator tile for on-orbit repair of shuttle TPS

The reusable surface insulation (RSI) material used in the shuttle thermal protection system is susceptible to damage. If any RSI tiles are damaged or lost during ascent, they must be repaired or replaced prior to entry. One approach to replacing a damaged or missing RSI tile consists of mechanically attaching a tile of ablation material in the place of the RSI tile. The thermal performance of this type of repair tile was evaluated in a simulated entry heating environment. The test specimen consisted of the ablator repair tile mechanically fastened to the strain isolation pad and surrounded by RSI tiles. The evaluation of the thermal performance was based on temperature response, surface integrity, and predicted flight performance. When the ablator tile protruded 1/8 inch above the surrounding RSI tiles, the forward facing steps caused significant inflow of hot gas down the ablator RSI joints and this inflow caused greatly increased back surface temperatures.

Thompkins, S. S.↗

A Gene Expression Model of Intrinsic Tumor Radiosensitivity: Prediction of Response and Prognosis After Chemoradiation

Purpose: Development of a radiosensitivity predictive assay is a central goal of radiation oncology. We reasoned a gene expression model could be developed to predict intrinsic radiosensitivity and treatment response in patients. Methods and Materials: Radiosensitivity (determined by survival fraction at 2 Gy) was modeled as a function of gene expression, tissue of origin, ras status (mut/wt), and p53 status (mut/wt) in 48 human cancer cell lines. Ten genes were identified and used to build a rank-based linear regression algorithm to predict an intrinsic radiosensitivity index (RSI, high index = radioresistance). This model was applied to three independent cohorts treated with concurrent chemoradiation: head-and-neck cancer (HNC, n = 92); rectal cancer (n = 14); and esophageal cancer (n = 12). Results: Predicted RSI was significantly different in responders (R) vs. nonresponders (NR) in the rectal (RSI R vs. NR 0.32 vs. 0.46, p = 0.03), esophageal (RSI R vs. NR 0.37 vs. 0.50, p = 0.05) and combined rectal/esophageal (RSI R vs. NR 0.34 vs. 0.48, p = 0.001511) cohorts. Using a threshold RSI of 0.46, the model has a sensitivity of 80%, specificity of 82%, and positive predictive value of 86%. Finally, we evaluated the model as a prognostic marker in HNC. There was an improved 2-year locoregional control (LRC) in the predicted radiosensitive group (2-year LRC 86% vs. 61%, p = 0.05). Conclusions: We validate a robust multigene expression model of intrinsic tumor radiosensitivity in three independent cohorts totaling 118 patients. To our knowledge, this is the first time that a systems biology-based radiosensitivity model is validated in multiple independent clinical datasets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfacial fracture of Space-Shuttle thermal-protection system

Stable crack growth and fracture at the interface of undensified LI-900 reusable surface insulation (RSI) tile and the Nomex strain isolation pad (SIP) of the Space-Shuttle thermal-protection system (TPS) were modeled by double-edged notch-tension specimens. These specimens were loaded under uniaxial tension or 50-Hz cyclic loading and the resultant stable crack growth leading to eventual fracture was monitored by a videocamera. These tests showed that successive local tear-outs due to local tensile overload in the RSI tile resulted in the interfacial fracture where the crack-tip opening angle, CTOA, of the SIP was related to initiation and intermittent stable crack propagation. Fractures in similar static and dynamic test specimens using densified LI-900 RSI tiles occurred in the undensified regions of the RSI tiles. These failures were consistent with the above failure mechanism based on the local tensile strength of the undensified LI-900 RSI tile. The intermittent stable crack growth of undensified LI-900 RSI tile was reproduced by a deterministic, two-dimensional finite-element model with SIP of variable elastic moduli.

Komine, A.↗

Differences Between Colon Cancer Primaries and Metastases Using a Molecular Assay for Tumor Radiation Sensitivity Suggest Implications for Potential Oligometastatic SBRT Patient Selection

Purpose: We previously developed a multigene expression model of tumor radiation sensitivity index (RSI) with clinical validation in multiple independent cohorts (breast, rectal, esophageal, and head and neck patients). The purpose of this study was to assess differences between RSI scores in primary colon cancer and metastases. Methods and Materials: Patients were identified from our institutional review board–approved prospective observational protocol. A total of 704 metastatic and 1362 primary lesions were obtained from a de-identified metadata pool. RSI was calculated using the previously published rank-based algorithm. An independent cohort of 29 lung or liver colon metastases treated with 60 Gy in 5 fractions stereotactic body radiation therapy (SBRT) was used for validation. Results: The most common sites of metastases included liver (n=374; 53%), lung (n=116; 17%), and lymph nodes (n=40; 6%). Sixty percent of metastatic tumors, compared with 54% of primaries, were in the RSI radiation-resistant peak, suggesting metastatic tumors may be slightly more radiation resistant than primaries (P=.01). In contrast, when we analyzed metastases based on anatomical site, we uncovered large differences in RSI. The median RSIs for metastases in descending order of radiation resistance were ovary (0.48), abdomen (0.47), liver (0.43), brain (0.42), lung (0.32), and lymph nodes (0.31) (P<.0001). These findings were confirmed when the analysis was restricted to lesions from the same patient (n=139). In our independent cohort of treated lung and liver metastases, lung metastases had an improved local control rate compared to that in patients with liver metastases (2-year local control rate of 100% vs 73.0%, respectively; P=.026). Conclusions: Assessment of radiation sensitivity between primary and metastatic tissues of colon cancer histology revealed significant differences based on anatomical location of metastases. These initial results warrant validation in a larger clinical cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refurbishment cost study of the thermal protection system of a space shuttle vehicle. Phase 2: Supplement

The labor costs and techniques associated with the maintenance of a bonded-on ablator thermal protection system (TPS) concept, suitable for Space Shuttle application are examined. The baseline approach to TPS attachment involves bonding reusable surface insulation (RSI) and/or ablators to the structural skin of the vehicle. The RSI and/or ablators in the form of either flat or contoured panels can be bonded to the skin of the primary structure directly or by way of an intermediate silicone foam rubber pad. The use of foam rubber pads permits the use of buckling skins and protruding heat rivets on the primary structure, minimizing structural weight and fabrication costs. In the case of the RSI, the foam rubber pad serves as a required strain isolator. For purpose of comparison, test data were obtained for an installation with and without the use of a strain isolator. The refurbishment aspects of a bonded-on RSI concept (without a strain isolator) were examined experimentally along with several externally removable panel concepts employing both ablator and RSI TPS. The various concepts are compared.

Haas, D. W.↗

Improvement in Simulation of Eurasian Winter Climate Variability with a Realistic Arctic Sea Ice Condition in an Atmospheric GCM

The present study investigates how much a realistic Arctic sea ice condition can contribute to improve simulation of the winter climate variation over the Eurasia region. Model experiments are set up using different sea ice boundary conditions over the past 24 years (i.e., 1988-2011). One is an atmospheric model inter-comparison (AMIP) type of run forced with observed sea-surface temperature (SST), sea ice, and greenhouse gases (referred to as Exp RSI), and the other is the same as Exp RSI except for the sea ice forcing, which is a repeating climatological annual cycle (referred to as Exp CSI). Results show that Exp RSI produces the observed dominant pattern of Eurasian winter temperatures and their interannual variation better than Exp CSI (correlation difference up to approx. 0.3). Exp RSI captures the observed strong relationship between the sea ice concentration near the Barents and Kara seas and the temperature anomaly across Eurasia, including northeastern Asia, which is not well captured in Exp CSI. Lagged atmospheric responses to sea ice retreat are examined using observations to understand atmospheric processes for the Eurasian cooling response including the Arctic temperature increase, sea-level pressure increase, upper-level jet weakening and cold air outbreak toward the mid-latitude. The reproducibility of these lagged responses by Exp RSI is also evaluated.

sea-ice↗

Investigation of Reactive Silver Ink Formula for Reduced Silver Consumption in Silicon Heterojunction Metallization

Silver is the most expensive non-silicon component in photovoltaic cells. This is particularly salient for silicon heterojunction (SHJ) cells, which rely on large quantities of low-temperature silver pastes (LT-SP). SHJ cells would benefit greatly from an industrially scalable metallization process that simultaneously offers low silver consumption, low finger resistivities (<20 μΩ·cm), and low processing temperatures. Printed reactive silver inks (RSI) are an innovative candidate to this end. Furthermore, this work furthers the research on RSI metallization by investigating the impact of ink formula on properties pertinent to SHJ cells, including electrical properties, line width, ink splatter, silver consumption, cell performance, and adhesion. We introduce a scalable, high-throughput flexible needle contact printing approach for metallization that solves many of the issues associated with drop-on-demand printing. The printed silver fingers are characterized using electrical measurements and top-down and cross-sectional microscopy. The best performing ink, consisting of silver acetate, ethylamine, and formic acid, achieved silver fingers with total resistivities of 3.1 μΩ·cm and contact resistivities of 3.2 mΩ·cm 2 when printed at 61 °C. This ink metallized a full-sized 156 mm × 156 mm SHJ cell. This is the first reported data for RSI metallization of a full-sized SHJ cell and shows how an optimized RSI can achieve similar performances to LT-SP while consuming 80–90% less silver.

14 SOLAR ENERGY↗

Radiosensitivity Differences Between Liver Metastases Based on Primary Histology Suggest Implications for Clinical Outcomes After Stereotactic Body Radiation Therapy

Purpose/Objectives: Evidence from the management of oligometastases with stereotactic body radiation therapy (SBRT) reveals differences in outcomes based on primary histology. We have previously identified a multigene expression index for tumor radiosensitivity (RSI) with validation in multiple independent cohorts. In this study, we assessed RSI in liver metastases and assessed our clinical outcomes after SBRT based on primary histology. Methods and Materials: Patients were identified from our prospective, observational protocol. The previously tested RSI 10 gene assay was run on samples and calculated using the published algorithm. An independent cohort of 33 patients with 38 liver metastases treated with SBRT was used for clinical correlation. Results: A total of 372 unique metastatic liver lesions were identified for inclusion from our prospective, institutional metadata pool. The most common primary histologies for liver metastases were colorectal adenocarcinoma (n=314, 84.4%), breast adenocarcinoma (n=12, 3.2%), and pancreas neuroendocrine (n=11, 3%). There were significant differences in RSI of liver metastases based on histology. The median RSIs for liver metastases in descending order of radioresistance were gastrointestinal stromal tumor (0.57), melanoma (0.53), colorectal neuroendocrine (0.46), pancreas neuroendocrine (0.44), colorectal adenocarcinoma (0.43), breast adenocarcinoma (0.35), lung adenocarcinoma (0.31), pancreas adenocarcinoma (0.27), anal squamous cell cancer (0.22), and small intestine neuroendocrine (0.21) (P<.0001). The 12-month and 24-month Kaplan-Meier rates of local control (LC) for colorectal lesions from the independent clinical cohort were 79% and 59%, compared with 100% for noncolorectal lesions (P=.019), respectively. Conclusions: In this analysis, we found significant differences based on primary histology. This study suggests that primary histology may be an important factor to consider in SBRT radiation dose selection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvement of reusable surface insulation material

The results are presented of a program to improve the reusable surface insulation (RSI) system through the improvement of the LI-1500 material properties and the simplification of the RSI system. The improvements made include: 2500 F-capability RSI systems, water-impervious surface coatings, establishment of a high-emittance coating constituent, development of a secondary water-reduction system, and achievement of a lower density (9 pcf) RSI material.

Source record↗

Opacified silica reusable surface insulation /RSI/ for thermal protection of the Space Shuttle Orbiter

A reusable surface insulation (RSI) material adopted for use on limited areas of the Orbiter's heat shield is described. The RSI is a rigid sintered fibrous silica material containing about 3% by weight of 1200-grit silicon carbide powder. RSI manufacture is described; strength characteristics and thermal conductivity of the final product can be tailored by controlling the isotropy, and the density, coefficient of thermal expansion, and specific heat are reported. Data establishing that opacification of RSI with silicon carbide lowers the thermal conductivity are presented.

Goldstein, H. E.↗

Comparison of Orbiter STS-2 development flight instrumentation data with thermal math model predictions

Thermal performance verification of Reusable Surface Insulation (RSI) has been accomplished by comparisons of STS-2 Orbiter Flight Test (OFT) data with Thermal Math Model (TMM) predictions. The OFT data was obtained from Development Flight Instrumentation RSI plug and gap thermocouples. Quartertile RSI TMMs were developed using measured flight data for surface temperature and pressure environments. Reference surface heating rates, derived from surface temperature data, were multiplied by gap heating ratios to obtain tile sidewall heating rates. This TMM analysis resulted in good agreement of predicted temperatures with flight data for thermocouples located in the RSI, Strain Isolation Pad, filler bar and structure.

Norman, I.↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Worldwide benchmarking of cost-effective radiometers for direct and diffuse irradiance

Solar energy projects can benefit from direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) measurements during all project phases. Several commercial measurement systems for DNI and DHI are available. Sun trackers with pyranometers and pyrheliometers can provide highly accurate measurements but are often impractical in solar energy applications. For less expensive and more robust sensors, it is often unclear which accuracy can be expected under a project site's specific atmospheric conditions. We address this challenge through our dedicated experimental comparison of relevant sensor systems (rotating shadowband irradiometer [short RSI], Delta-T SPN1, EKO MS-90, PyranoCam, Sunto CaptPro, Kipp & Zonen CSD3) at up to six sites worldwide. The RSI systems (rRMSD 3 to 8.6%, DNI; 4.8 to 7.6%, DHI) and PyranoCam (rRMSD 2.6 to 5.2%, DNI; 4.4 to 5.8%, DHI) exhibit similar error metrics and are the most accurate systems in the test. Delta-T SPN1 and EKO MS-90 (rRMSD 6.8 to 15%, DNI; 10.6 to 20.1%, DHI) but especially Kipp & Zonen CSD3 and Sunto CaptPro show significant deviations (rRMSD 17.7 to 20%, DNI; 33 to 58%, DHI). We evaluate the influence of relevant atmospheric parameters on the sensors' accuracies by a rather unique measurement setup. MS-90's DNI errors depend on DNI itself, with overestimations for low reference DNI. The deviations of SPN1's DHI and DNI measurements increase sharply in situations with high circumsolar irradiance. Also CaptPro and CSD3's increased measurement errors are related to circumsolar irradiance. For RSI and PyranoCam, only moderate influences on the measurements are identified, indicating a general applicability of these instruments.

14 SOLAR ENERGY↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗