Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROTATING ENVIRONMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rotating cooloing flows

We describe the evolution of the hot interstellar medium in a large, slowly rotating elliptical galaxy. Although the rotation assumed is a small fraction of the circular velocity, in accordance with recent observations, it is sufficient to have a profound influence on the X-ray emission and cooling geometry of the interstellar gas. The hot gas cools into a disk that extends out to approximately 10 kpc. The cool, dusty disks observed in the majority of elliptical galaxies may arise naturally from internal cooling rather than from mergers with gas-rich companions. As a result of angular momentum conservation in the cooling flow, the soft X-ray isophotes are quite noticeably flatter than those of the stellar image. The gas temperature is higer along the rotation axis. The rotational velocity of the gas several kiloparcsecs above the central disk far exceeds the local stellar rotation and approaches the local circular velocity as it flows toward the galactic core. The detailed appearance of the X-ray image and velocity field of the X-ray gas provide information about the global rotational properties of giant ellipticals at radii too distant for optical observations. The overall pattern of rotation in these galaxies retains information about the origin of ellipticals, particularly of their merging history. In ellipticals having radio jets, if the jets are aligned with the rotation axis of the inner cooling flow, rotation within the jet could be sustained by the rotating environment. Since most large ellipticals have modest rotation, the X-ray observations at low spatial resolution, when interpreted with spherical theoretical models, give the impression that hot gas undergoes localized cooling to very low temperatures many kiloparcsecs from the galactic core. We suggest that such apparent cooling can result in a natural way as gas cools onto a rotating disk.

Kley, Wilhelm↗

Balance in a rotating artificial gravity environment

When subjects stand at the center of a fully enclosed room that is rotating at constant velocity, their natural postural sway generates Coriolis forces that destabilize their center of mass and head. We quantitatively assessed how exposure to constant velocity rotation at 10 rpm affected postural control. Twelve subjects stood in a heel-to-toe stance in the rotating room. Each test session involved three phases: (1) pre-rotation, (2) per-rotation, and (3) post-rotation. In each phase, subjects were tested in both eyes open and eyes closed conditions. Four measures were used to characterize center of mass movement and head movement: mean sway amplitude, total power, mean power frequency, and frequency of maximum power. Each measure was computed for anterior-posterior and medial-lateral sway. Both anterior-posterior and medial-lateral head and center of mass sway during rotation had significantly greater mean sway amplitude and total power compared with pre- and post-rotation values. Mean power frequency and frequency of maximum power were little affected. Eyes open conditions were significantly more stable in all test phases than eyes-closed, but vision did not completely suppress the effects of rotation. The greatest effect of rotation was in the eyes-closed condition with mean sway amplitude and total power increasing more than twofold. Inverted pendulum sway was maintained in all phases of both test conditions. No aftereffects of rotation were present after the four 25-s exposures each subject received. We expect that with longer exposure periods and with active generation of body sway subjects would both adapt to rotation and exhibit post-rotary aftereffects.

NASA Discipline Neuroscience↗

Sensorimotor aspects of high-speed artificial gravity: I. Sensory conflict in vestibular adaptation

Short-radius centrifugation offers a promising and affordable countermeasure to the adverse effects of prolonged weightlessness. However, head movements made in a fast rotating environment elicit Coriolis effects, which seriously compromise sensory and motor processes. We found that participants can adapt to these Coriolis effects when exposed intermittently to high rotation rates and, at the same time, can maintain their perceptual-motor coordination in stationary environments. In this paper, we explore the role of inter-sensory conflict in this adaptation process. Different measures (vertical nystagmus, illusory body tilt, motion sickness) react differently to visual-vestibular conflict and adapt differently. In particular, proprioceptive-vestibular conflict sufficed to adapt subjective parameters and the time constant of nystagmus decay, while retinal slip was required for VOR gain adaptation. A simple correlation between the strength of intersensory conflict and the efficacy of adaptation fails to explain the data. Implications of these findings, which differ from existing data for low rotation rates, are discussed.

Non-NASA Center↗

Artificial gravity as a countermeasure in long-duration space flight

Long-duration exposure to weightlessness results in bone demineralization, muscle atrophy, cardiovascular deconditioning, altered sensory-motor control, and central nervous system reorganizations. Exercise countermeasures and body loading methods so far employed have failed to prevent these changes. A human mission to Mars might last 2 or 3 years and without effective countermeasures could result in dangerous levels of bone and muscle loss. Artificial gravity generated by rotation of an entire space vehicle or of an inner chamber could be used to prevent structural changes. Some of the physical characteristics of rotating environments are outlined along with their implications for human performance. Artificial gravity is the centripetal force generated in a rotating vehicle and is proportional to the product of the square of angular velocity and the radius of rotation. Thus, for a particular g-level, there is a tradeoff between velocity of rotation and radius. Increased radius is vastly more expensive to achieve than velocity, so it is important to know the highest rotation rates to which humans can adapt. Early studies suggested that 3 rpm might be the upper limit because movement control and orientation were disrupted at higher velocities and motion sickness and chronic fatigue were persistent problems. Recent studies, however, are showing that, if the terminal velocity is achieved over a series of gradual steps and many body movements are made at each dwell velocity, then full adaptation of head, arm, and leg movements is possible. Rotation rates as high as 7.5-10 rpm are likely feasible. An important feature of the new studies is that they provide compelling evidence that equilibrium point theories of movement control are inadequate. The central principles of equilibrium point theories lead to the equifinality prediction, which is violated by movements made in rotating reference frames. Copyright 2000 Wiley-Liss, Inc.

Review Literature↗

Adaptation in a rotating artificial gravity environment

The centripetal force generated by a rotating space vehicle is a potential source of artificial gravity. Minimizing the cost of such a vehicle dictates using the smallest radius and highest rotation rate possible, but head movements made at high rotation rates generate disorienting, nauseogenic cross-coupled semicircular canal stimulation. Early studies suggested 3 or 4 rpm as the highest rate at which humans could adapt to this vestibular stimulus. These studies neglected the concomitant Coriolis force actions on the head/neck system. We assessed non-vestibular Coriolis effects by measuring arm and leg movements made in the center of a rotating room turning at 10 rpm and found that movement endpoints and trajectories are initially deviated; however, subjects readily adapt with 10-20 additional movements, even without seeing their errors. Equilibrium point theories of motor control errantly predict that Coriolis forces will not cause movement endpoint errors so that subjects will not have to adapt their reaching movements during rotation. Adaptation of movement trajectory acquired during Coriolis force perturbations of one arm transfers to the unexposed arm but there is no intermanual transfer of endpoint adaptation indicating that neuromotor representations of movement endpoint and trajectory are separable and can adapt independently, also contradictory to equilibrium point theories. Touching a surface at the end of reaching movements is required for complete endpoint adaptation in darkness but trajectory adapts completely with or without terminal contact. We have also made the first kinematic measurements of unconstrained head movements during rotation, these movements show rapid adaptation to Coriolis force perturbations. Our results point to methods for achieving full compensation for rotation up to 10 rpm. Copyright 1998 Published by Elsevier Science B.V.

Non-NASA Center↗

Design of experimental studies of human performance under influences of simulated artificial gravity

A ground based research program is now being undertaken to provide data concerning the effects of a rotating environment on man's ability to adequately perform gross and fine psychomotor tasks. Emphasis is being placed on establishing the levels of artificial gravity and rates and radii of rotation required in future space systems for preservation of crew performance and comfort. An experimental study utilizing a rotational facility to investigate crew mobility, cargo transfer and handling, and fine motor coordination at radii up to 24 meters and at rotational rates up to 5 rpm is reported.

Piland, W. M.↗

Gravitoinertial force background level affects adaptation to coriolis force perturbations of reaching movements

We evaluated the combined effects on reaching movements of the transient, movement-dependent Coriolis forces and the static centrifugal forces generated in a rotating environment. Specifically, we assessed the effects of comparable Coriolis force perturbations in different static force backgrounds. Two groups of subjects made reaching movements toward a just-extinguished visual target before rotation began, during 10 rpm counterclockwise rotation, and after rotation ceased. One group was seated on the axis of rotation, the other 2.23 m away. The resultant of gravity and centrifugal force on the hand was 1.0 g for the on-center group during 10 rpm rotation, and 1.031 g for the off-center group because of the 0.25 g centrifugal force present. For both groups, rightward Coriolis forces, approximately 0.2 g peak, were generated during voluntary arm movements. The endpoints and paths of the initial per-rotation movements were deviated rightward for both groups by comparable amounts. Within 10 subsequent reaches, the on-center group regained baseline accuracy and straight-line paths; however, even after 40 movements the off-center group had not resumed baseline endpoint accuracy. Mirror-image aftereffects occurred when rotation stopped. These findings demonstrate that manual control is disrupted by transient Coriolis force perturbations and that adaptation can occur even in the absence of visual feedback. An increase, even a small one, in background force level above normal gravity does not affect the size of the reaching errors induced by Coriolis forces nor does it affect the rate of reacquiring straight reaching paths; however, it does hinder restoration of reaching accuracy.

NASA Discipline Neuroscience↗

Orientation and movement in unusual force environments

A manned space mission to Mars might take as long as 1 year each way. Consequently, artificial gravity is being considered as a way of preventing the debilitating effects of long-duration exposure to microgravity on the human body. The present article discusses some of the problems associated with adapting to the rotation levels that might be used to generate artificial gravity. It also describes how exposure to background-force levels greater or less than the 1-G force of Earth gravity affects orientation and movement control. The primary emphasis of the article is that human movement and orientation control are dynamically adapted to the 1-G force background of Earth and that accommodation to altered force levels or to rotating environments requires a wide range of adaptive changes.

Parabolic Flight↗

Artificial gravity: head movements during short-radius centrifugation

Short-radius centrifugation is a potential countermeasure to long-term weightlessness. Unfortunately, head movements in a rotating environment induce serious discomfort, non-compensatory vestibulo-ocular reflexes, and subjective illusions of body tilt. In two experiments we investigated the effects of pitch and yaw head movements in participants placed supine on a rotating bed with their head at the center of rotation, feet at the rim. The vast majority of participants experienced motion sickness, inappropriate vertical nystagmus and illusory tilt and roll as predicted by a semicircular canal model. However, a small but significant number of the 28 participants experienced tilt in the predicted plane but in the opposite direction. Heart rate was elevated following one-second duration head turns. Significant adaptation occurred following a series of head turns in the light. Vertical nystagmus, motion sickness and illusory tilt all decreased with adaptation. Consequences for artificial gravity produced by short-radius centrifuges as a countermeasure are discussed. Grant numbers: NCC 9-58. c 2001. Elsevier Science Ltd. All rights reserved.

Non-NASA Center↗

Artificial gravity - A countermeasure for zero gravity

Current knowledge on artificial gravity is presented with emphasis placed on the unique characteristics of such an environment and their effects on crew performance and vehicle habitability. A parametric optimization of the vehicle size and operation is performed. The following set of 'optimum' parameter values is obtained: a cost of 15.8 billion dollars, a radius of 80 feet, a rotation rate of 4.8 rpm, and a g-value of 0.62. Consideration is also given to the problems of adaptation, retention of adaptation, and simultaneous adaptation to both nonrotating and rotating environments.

Nicogossian, A. E.↗

Dynamic testing of thin-walled composite box beams in a vacuum chamber

Vibration characteristics of thin-walled composite box beams are measured in a rotating environment in a 10-ft diameter vacuum chamber. Symmetric and antisymmetric layup beams are fabricated out of graphite/epoxy prepreg material using an autoclave molding technique. These are excited using piezoelectric ceramic elements and responses are measured using strain gages and accelerometers. First three natural modes are identified using spectrum analyzer over a range of rotational speeds up to 1000 rpm. Measured frequencies and mode shapes (displacement as well as strain) are correlated satisfactorily with calculated finite element results.

Chandra, Ramesh↗

Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Clinical Trial↗

Congenitally blind individuals rapidly adapt to coriolis force perturbations of their reaching movements

Reaching movements made to visual targets in a rotating room are initially deviated in path and endpoint in the direction of transient Coriolis forces generated by the motion of the arm relative to the rotating environment. With additional reaches, movements become progressively straighter and more accurate. Such adaptation can occur even in the absence of visual feedback about movement progression or terminus. Here we examined whether congenitally blind and sighted subjects without visual feedback would demonstrate adaptation to Coriolis forces when they pointed to a haptically specified target location. Subjects were tested pre-, per-, and postrotation at 10 rpm counterclockwise. Reaching to straight ahead targets prerotation, both groups exhibited slightly curved paths. Per-rotation, both groups showed large initial deviations of movement path and curvature but within 12 reaches on average had returned to prerotation curvature levels and endpoints. Postrotation, both groups showed mirror image patterns of curvature and endpoint to the per-rotation pattern. The groups did not differ significantly on any of the performance measures. These results provide compelling evidence that motor adaptation to Coriolis perturbations can be achieved on the basis of proprioceptive, somatosensory, and motor information in the complete absence of visual experience.

NASA Discipline Neuroscience↗

Expansion of Microbial Monitoring Capabilities on the International Space Station (ISS)

Microbial monitoring is one of the tools that the National Aeronautics and Space Administration (NASA) uses on the International Space Station (ISS) to help maintain crew health and safety. In combination with regular housekeeping and disinfection when needed, microbial monitoring provides important information to the crew about the quality of the environment. Rotation of astronauts, equipment, and cargo on the ISS can affect the microbial load in the air, surfaces, and water. The current ISS microbial monitoring methods are focused on culture-based enumeration during flight and require a significant amount of crew time as well as long incubation periods of up to 5 days there by proliferating potential pathogens. In addition, the samples require return to Earth for complete identification of the microorganisms cultivated. Although the current approach assess the quality of the ISS environment, molecular technology offers faster turn-around of information particularly beneficial in an off-nominal situation. In 2011, subject matter experts from industry and academia recommended implementation of molecular-based technologies such as quantitative real-time polymerase chain reaction (qPCR) for evaluation to replace current, culture-based technologies. The RAZOR EX (BioFire Defense, Inc, Salt Lake City, UT) a ruggedized, compact, COTS (commercial off the shelf) qPCR instrument was tested, evaluated and selected in the 2 X 2015 JSC rapid flight hardware demonstration initiative as part of the Water Monitoring Suite. RAZOR EX was launched to ISS on SpaceX-9 in July 2016 to evaluate the precision and accuracy of the hardware by testing various concentrations of DNA in microgravity compared to ground controls. Flight testing was completed between September 2016 and March 2017. Data presented will detail the hardware performance of flight testing results compared to ground controls. Future goals include additional operational ground-based testing and assay development to determine if this technology can meet spaceflight microbial monitoring requirements.

Khodadad, Christina L.↗