Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESISTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Time-adjusted variable resistor

Timing mechanism was developed effecting extremely precisioned highly resistant fixed resistor. Switches shunt all or portion of resistor; effective resistance is varied over time interval by adjusting switch closure rate.

Heyser, R. C.↗

Vamistor resistor investigation

Results are presented of the failure investigation conducted on resistors produced by the Vamistor Divison, Wagner Electric Corporation. This failure investigation included; failure analyses, chemical and metallurgical analyses, failure mechanism studies, seal leak analyses, and nondestructive stress tests. The data, information, conclusions, and recommendation can be helpful in assessing current usage of these resistors.

Source record↗

Three-terminal shielded resistors for fast electrometers

The design of electrometer feedback resistors for use at frequencies up to the kilohertz range is discussed. It is shown experimentally that the addition of capacitive coupling between the electrometer output and the center of the feedback resistor, combined with suitable shielding, gives substantially better performance at high frequencies than is obtainable with more conventional designs.

Kendall, B. R. F.↗

Factors affecting laser-trim stability of thick film resistors

Various factors affecting precision of trim and resistor stability were considered. The influence of machine operating parameters on resistor performance was examined and quantified through statistically designed experiments for a Q switched YAG laser system. Laser kerf quality was studied by scanning electron microscopy and related to kerf isolation resistance measurements. A relatively simple production oriented, quality control test is proposed for rapid determination of kerf electrical stability. In addition, the effect of cut design and extent of trim on precision and stability were discussed.

Cote, R. E.↗

Improved switch-resistor packaging

Packaging approach makes resistors more accessible and easily identified with specific switches. Failures are repaired more quickly because of improved accessibility. Typical board includes one resistor that acts as circuit breaker, and others are positioned so that their values can be easily measured when switch is operated. Approach saves weight by using less wire and saves valuable panel space.

Redmerski, R. E.↗

Characterization of feedback resistors for cryogenic applications

Results are presented on the testing of feedback resistors selected for use in the transimpedance amplifiers (TIAs) in the Diffuse Infrared Background Experiment (DIRBE) to be flown on the NASA's Cosmic Background Explorer satellite planned for a launch in 1989. The resistors without encapsulation were found to be reliable as cryogenic circuit elements. Their resistance is sufficiently high (so that their Johnson noise does not dominate amplifier noise at the signal frequency), and they are sufficiently linear; no correction need to be made for signals up to 1.5 V, the 100,000 signal-to-noise level for the DIRBE, which covers most of the signals expected to be seen on the sky.

Lakew, B.↗

Electrostatic Discharge (ESD) Failures in Thin Film Resistors

Field failures of nichrome thin film resistors have been investigated recently for several pieces of space flight hardware. These failures have involved resistance shifts ranging from a few percent to complete open circuits. Failure analysis and duplication of these failures have revealed that the failures were caused by electrostatic discharge. The failure characteristics and the circuit conditions necessary for failure have been studied for several types of thin film resistors including nichrome and tantalum nitride resistive elements. The effects of latent damage and resistive pattern design will also be discussed.

Hull, Scott M.↗

Effects of Hydrogen on Tantalum Nitride Resistors

This document is a presentation about the investigation of drift reported in static frequency output from the analog circuit of a Multichannel Microwave Integrated circuit hybrid microelectronic filter module for space flight application. Electron Dispersion X-Ray Detector )EDAX) Analysis of the 35k ohm thin film Tantalum Nitride Chip resistors identified Palladium in the film. A catalytic reaction of Palladium and hydrogen produces mono atomic hydrogen. When the filter module cavities were filled with a 4 % hydrogen 96 % Nitrogen gas mixture at 25C and monitored the electrical performance for 24 hours. Some channels drifted in a similar pattern as the channel being investigated. Palladium was found on the resistors. The corrective actions taken are reviewed, which resulted in a stable circuit.

Weiler, James↗

Effects of Hydrogen on Tantalum Nitride Resistors

In this paper we report on observations of degradation of thin film Tantalum Nitride chip resistors in a hermetically sealed hybrid. The observations have been attributed to the reaction of residual Palladium with desorbed Hydrogen on the surface of the resistor film. Hydrogen gas has been observed to desorb from various sources within the sealed hybrid as a result of temperature elevation. The hydrogen gas has been reported to undergo a reaction with elements such as Platinum and Palladium causing device degradation in Gallium Arsenide Field Effect Transistors. The experimental procedures and data relating to this observation along with a discussion of available risk mitigation techniques will be presented.

Weiler, James↗

Indium Tin Oxide Resistor-Based Nitric Oxide Microsensors

A sensitive resistor-based NO microsensor, with a wide detection range and a low detection limit, has been developed. Semiconductor microfabrication techniques were used to create a sensor that has a simple, robust structure with a sensing area of 1.10 ~ 0.99 mm. A Pt interdigitated structure was used for the electrodes to maximize the sensor signal output. N-type semiconductor indium tin oxide (ITO) thin film was sputter-deposited as a sensing material on the electrode surface, and between the electrode fingers. Alumina substrate (250 m in thickness) was sequentially used for sensor fabrication. The resulting sensor was tested by applying a voltage across the two electrodes and measuring the resulting current. The sensor was tested at different concentrations of NO-containing gas at a range of temperatures. Preliminary results showed that the sensor had a relatively high sensitivity to NO at 450 C and 1 V. NO concentrations from ppm to ppb ranges were detected with the low limit of near 159 ppb. Lower NO concentrations are being tested. Two sensing mechanisms were involved in the NO gas detection at ppm level: adsorption and oxidation reactions, whereas at ppb level of NO, only one sensing mechanism of adsorption was involved. The NO microsensor has the advantages of high sensitivity, small size, simple batch fabrication, high sensor yield, low cost, and low power consumption due to its microsize. The resistor-based thin-film sensor is meant for detection of low concentrations of NO gas, mainly in the ppb or lower range, and is being developed concurrently with other sensor technology for multispecies detection. This development demonstrates that ITO is a sensitive sensing material for NO detection. It also provides crucial information for future selection of nanostructured and nanosized NO sensing materials, which are expected to be more sensitive and to consume less power.

Xu, Jennifer C.↗

For current viewing resistor loads

The invention comprises a terminal unit for a flat cable comprising a BNC-PCB connector having a pin for electrically contacting one or more conducting elements of a flat cable, and a current viewing resistor having an opening through which the pin extends and having a resistor face that abuts a connector face of the BNC-PCB connector, wherein the device is a terminal unit for the flat cable.

47 OTHER INSTRUMENTATION↗

Imaginary resistor based Parity-Time symmetry electronics dimers

An approach of fabricating Parity-Time symmetry electronic dimers circuits is demonstrated using an imaginary resistor Z whose impedance is frequency independent. Remarkably, the dynamic rate equations of the coupled oscillators so-called ZRC dimers, uniquely consist of first order partial differential equations which result in a 2 ×2 effective Hamiltonians commuting with the joint Parity-Time (PT) operator. The method helps in describing two groups of PT symmetry electronics. The first group has an eigenspectrum that displays a single spontaneous PT transition or a thresholdless (THL) PT transition. The second group is a PT transitionless normal mode spectrum with essentially negative values of capacitors. The dynamics indicate that the system exhibits high frequencies propagation when operation is done before the thresholdless point is reached. The transitionless regime indicates an equilibrium point in the coupling for which the system turns to be conservative regardless the gain/loss values, and beyond which the gain/loss remarkably decays/amplifies wave. In addition, we observe a value of gain/loss above which there is a limitation of signal amplification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trigonometrical sums connected with the chiral Potts model, Verlinde dimension formula, two-dimensional resistor network, and number theory

We have recently developed methods for obtaining exact two-point resistance of the complete graph minus N edges. We use these methods to obtain closed formulas of certain trigonometrical sums that arise in connection with one-dimensional lattice, in proving Scott’s conjecture on permanent of Cauchy matrix, and in the perturbative chiral Potts model. The generalized trigonometrical sums of the chiral Potts model are shown to satisfy recursion formulas that are transparent and direct, and differ from those of Gervois and Mehta. By making a change of variables in these recursion formulas, the dimension of the space of conformal blocks of SU(2) and SO(3) WZW models may be computed recursively. Our methods are then extended to compute the corner-to-corner resistance, and the Kirchhoff index of the first non-trivial two-dimensional resistor network, 2×N. Finally, we obtain new closed formulas for variant of trigonometrical sums, some of which appear in connection with number theory. -- Highlights: • Alternative derivation of certain trigonometrical sums of the chiral Potts model are given. • Generalization of these trigonometrical sums satisfy recursion formulas. • The dimension of the space of conformal blocks may be computed from these recursions. • Exact corner-to-corner resistance, the Kirchhoff index of 2×N are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A two-dimensional resistor network model for transition-edge sensors with normal metal features

Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one dimension, but until now, there have been no predictive models of the influence of two-dimensional (2-D) normal metal features on the TES transition shape. Here, we approach this problem by treating the TES as a 2-D network of resistors, the values of which are based on the two-fluid model. We introduce a study of the behavior of devices with different 2-D geometric features. Our 2-D network model is capable of predicting how typical TES geometry parameters, such as number of bars, bar spacing, and overall dimensions, influence device behavior and thus is a powerful tool to guide the engineering of new TES devices.

2-D resistors network↗

SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by the Industrial R&D program of MOTIE/KEIT. [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-09: Feasibility Study for Thermoplastic Mask Set Up Monitoring Using Force Sensing Resistor (FSR) Sensor

Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with a head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗