Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A PC based time domain reflectometer for space station cable fault isolation

Significant problems are faced by astronauts on orbit in the Space Station when trying to locate electrical faults in multi-segment avionics and communication cables. These problems necessitate the development of an automated portable device that will detect and locate cable faults using the pulse-echo technique known as Time Domain Reflectometry. A breadboard time domain reflectometer (TDR) circuit board was designed and developed at the NASA-JSC. The TDR board works in conjunction with a GRiD lap-top computer to automate the fault detection and isolation process. A software program was written to automatically display the nature and location of any possible faults. The breadboard system can isolate open circuit and short circuit faults within two feet in a typical space station cable configuration. Follow-on efforts planned for 1994 will produce a compact, portable prototype Space Station TDR capable of automated switching in multi-conductor cables for high fidelity evaluation. This device has many possible commercial applications, including commercial and military aircraft avionics, cable TV, telephone, communication, information and computer network systems. This paper describes the principle of time domain reflectometry and the methodology for on-orbit avionics utility distribution system repair, utilizing the newly developed device called the Space Station Time Domain Reflectometer (SSTDR).

Pham, Michael↗

Portable Infrared Reflectometer Designed and Manufactured for Evaluating Emittance in the Laboratory or in the Field

The optical properties of materials play a key role in spacecraft thermal control. In space, radiant heat transfer is the only mode of heat transfer that can reject heat from a spacecraft. One of the key properties for defining radiant heat transfer is emittance, a measure of how efficiently a surface can reject heat in comparison to a perfect black body emitter. Heat rejection occurs in the infrared region of the spectrum, nominally in the range of 2 to 25 mm. To calculate emittance, one obtains the reflectance over this spectral range, calculates spectral absorptance by difference, and then uses Kirchhoff s Law and the Stefan-Boltzmann equation to calculate emittance. A new portable infrared reflectometer, the SOC 400t, was designed and manufactured to evaluate the emittance of surfaces and coatings in the laboratory or in the field. It was developed by Surface Optics Corporation under a contract with the NASA Glenn Research Center at Lewis Field to replace the Center s aging Gier-Dunkle DB-100 infrared reflectometer. The specifications for the new instrument include a wavelength range of 2 to 25 mm; reflectance repeatability of +/-1 percent; self-calibrating, near-normal spectral reflectance measurements; a full scan measurement time of 3.5 min, a sample size of 1.27 cm (0.5 in.); a spectral resolution selectable from 4, 8, 16, or 32/cm; and optical property characterization utilizing an automatic integration to calculate total emittance in a selectable temperature range.

Jaworske, Donald A.↗

Optimization studies of the ITER low field side reflectometer

Microwave reflectometry will be used on ITER to measure the electron density profile, density fluctuations due to MHD/turbulence, ELM density transients, and as a L-H transition monitor. The ITER low field side (LFS) reflectometer system will measure both core and edge quantities using multiple antenna arrays spanning frequency ranges of 15-155 GHz for the O-mode system and 55-220 GHz for the X-mode system. Optimization studies using the GENRAY ray-tracing code have been done for edge and core measurements. The reflectometer launchers will utilize the HE11 mode launched from circular corrugated waveguide. The launched beams are assumed to be Gaussian with a beam waist diameter of 0.643 times the waveguide diameter. Optimum launcher size and placement are investigated by computing the antenna coupling between launchers, assuming the launched and received beams have a Gaussian beam pattern.

47 OTHER INSTRUMENTATION↗

Time-of-Flight Bragg Scattering from Aligned Stacks of Lipid Bilayers using the Liquids Reflectometer at the Spallation Neutron Source

Time-of-flight (TOF) neutron diffraction experiments on aligned stacks of lipid bilayers using the horizontal Liquids Reflectometer at the Spallation Neutron Source are reported. Specific details are given regarding the instrumental setup, data collection and reduction, phase determination of the structure factors, and reconstruction of the one-dimensional neutron scattering length density (NSLD) profile. The validity of using TOF measurements to determine the one-dimensional NSLD profile is demonstrated by reproducing the results of two well known lipid bilayer structures. The method is then applied to show how an antimicrobial peptide affects membranes with and without cholesterol.

Lipid Bilayers↗

High Data Rate Detector for Neutron Reflectometer

Neutron reflectometers are a class of instruments that employ neutron diffraction for measuring the structure of thin films. The technique provides valuable information over a wide variety of scientific and technological applications including chemical aggregation, polymer and surfactant adsorption, structure of thin film magnetic systems, biological membranes, etc. Such instruments are considered to be one of the most important in the neutron science field. Newer facilities place growing demands on the count rate capability of the specialized neutron detectors required. Proportional Technologies completed the Phase I effort successfully with a fully operational prototype detector built at PTI and tested at the CG1A neutron beam of the High Flux Isotope Reactor (HFIR, Oak Ridge, TN). The prototype incorporated 3 panels of 14 copper-walled cells each (total of 42 cells), each lined with 1.3 μm of 10B4C. The detector was tested for efficiency, spatial resolution, count rate linearity, uniformity, overlap and scatter. Testing revealed stable operation, uniform response across cells, and successful resolution of individual cells. The maximum count rate tested in the 3 panels combined was 590 kHz, limited by a deadtime of about 1 μs in the digital electronics. The local rate measured in a single cell showed no deadtime losses up to 810 cps/mm2, indicating that a rate of 20 Mhz can be supported in the 308-cell detector planned for Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

Measurement of edge density profiles of Large Helical Device plasmas using an ultrashort-pulse reflectometer

We report here on the application of an ultrashort-pulse reflectometer (USPR) to Large Helical Device in National Institute for Fusion Science. An impulse with picosecond pulse width is used as a source in an USPR. Since the bandwidth of a source is inversely related to the pulse width, we can utilize the frequency range of microwave to millimeter-wave by using wide band transmission lines. The density profiles can be reconstructed by collecting time-of-flight signal of each frequency component of an impulse reflected from each cutoff layer. Remote control system using super science information network has been introduced to the present USPR system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of ITER plasma position reflectometer using a two-dimensional full-wave finite-difference time domain code

The EU will supply the plasma position reflectometer for ITER. The system will have channels located at different poloidal positions, some of them obliquely viewing a plasma which has a poloidal density divergence and curvature, both adverse conditions for profile measurements. To understand the impact of such topology in the reconstruction of density profiles a full-wave two-dimensional finite-difference time domain O-mode code with the capability for frequency sweep was used. Simulations show that the reconstructed density profiles still meet the ITER radial accuracy specifications for plasma position (1 cm), except for the highest densities. Other adverse effects such as multireflections induced by the blanket, density fluctuations, and MHD activity were considered and a first understanding on their impact obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-adaptive sampling rate data acquisition in JET's correlation reflectometer

Data acquisition systems with self-adaptive sampling rate capabilities have been proposed as a solution to reduce the shear amount of data collected in every discharge of present fusion devices. This paper discusses the design of such a system for its use in the KG8B correlation reflectometer at JET. The system, which is based on the ITMS platform, continuously adapts the sample rate during the acquisition depending on the signal bandwidth. Data are acquired continuously at the expected maximum sample rate and transferred to a memory buffer in the host processor. Thereafter the rest of the process is based on software. Data are read from the memory buffer in blocks and for each block an intelligent decimation algorithm is applied. The decimation algorithm determines the signal bandwidth for each block in order to choose the optimum sample rate for that block, and from there the decimation factor to be used. Memory buffers are used to adapt the throughput of the three main software modules (data acquisition, processing, and storage) following a typical producer-consumer architecture. The system optimizes the amount of data collected while maintaining the same information. Design issues are discussed and results of performance evaluation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

V-band frequency hopping microwave reflectometer in LHD

In order to measure the internal structure of fluctuation, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, is applied in the Large Helical Device. One of the important issues of density fluctuation measurements using this reflectometer is the study of energetic particle driven magnetohydrodynamics instability. During one plasma discharge, the launching frequency changes from one frequency to another frequency, which this operation is called as frequency hopping, and the cutoff position can be scanned in the wide area. As a hopping source, a synthesizer is used because it has a quite stable and low phase noise. The frequency component of the source output is multiplied to V-band (50-75 GHz) region for plasma measurements in extraordinary mode polarization. Also this system has a heterodyne detection with single side band frequency modulation for sensitive phase and amplitude measurement. We can obtain the radial profile of Alfven eigenmodelike oscillation in a neutral beam injected plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler reflectometer system in the stellarator TJ-II

A Doppler reflectometer system has recently been installed in the stellarator TJ-II. The system is optimized for the Q-band (33-50 GHz) and the high-curvature plasmas produced in TJ-II. The launch angle of the microwave beam can be controlled by a steerable mirror to obtain angles between {+-}20 deg. enabling the measurement of perpendicular wave numbers in the range of 3-15 cm{sup -1}. The available angular range allows for comparisons between positive and negative values and additionally for calibration of the system. Localization and k{sub perpendicular}-estimation is done via the three-dimensional ray/beam-tracing code TRUBA. First measured spectra and radial profiles of the perpendicular velocity of plasma density fluctuations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗