Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECOVERY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An end-to-end workflow for executing a classically bootstrapped variational quantum algorithm on an academic quantum computer

Academic quantum computing platforms often face unique challenges in executing quantum workloads due to fragmented software environments and limited engineering support. Unlike commercial ecosystems, academic devices typically evolve without full-stack integration in mind, making it difficult to run complex applications—such as variational quantum algorithms (VQA)—reliably and efficiently. Issues such as incompatible software layers and lack of automated job management significantly increase the overhead of theory-experiment collaboration. To address these challenges, we develop a modular, end-to-end workflow that decouples application-layer code from low-level hardware control, automates circuit submission and result collection, and supports fine-grained circuit-level job scheduling and recovery. The architecture employs a dual-end application programming interface (API) design, enabling robust operation across unstable or resource-constrained hardware backends. For practical use, the framework is lightweight and user-friendly, allowing rapid prototyping of full-stack workflows using basic Python tools. We validate this workflow on a high-fidelity trapped-ion quantum computer by demonstrating a variational quantum eigensolver (VQE) experiment with a classically bootstrapped ansatz initialization technique. The system successfully executed over 60,000 circuits across multiple molecular test cases with minimal human intervention, highlighting the framework’s effectiveness in enabling reproducible, resilient quantum experimentation in academic settings.

Clifford↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗

Spatio-Kinetic Electronic Heterogeneity in MoS 2 Revealed by Ultrafast Electron Microscopy: Implications for Optoelectronics

There is broad interest in layered, two-dimensional (2D) semiconductors owing to their high optical absorption and ability to heterogeneously integrate with various substrates. In such layered semiconductors, mesoscopic imperfections, such as surface step edges, may affect charge carrier kinetics and device performance, but studying their effects on carrier transport with sufficient spatial and temporal resolution is a challenge. Using scanning ultrafast electron microscopy, we image the near-surface charge carrier kinetics with μm/ps spatiotemporal resolution in single-crystal MoS 2 samples with surface steps tens of nanometers in height. We find an approximately 3-fold increase in surface trap density near such surface steps compared to the uniform, flat surface regions. Despite the difference in trap state density, filling of the traps occurs over the same time scale (∼100 ps), but carrier recovery is much slower near the step compared to the uniform regions of the material. Furthermore, these results provide an approach to measure ultrafast dynamics and determine the required uniformity of layered materials depending on the speed limit constraints for specific applications.

SEM↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Radiation Accidents and Malicious Events – Scenarios and Scope of the Work of ICRP Task Group 120

The International Commission on Radiological Protection (ICRP) Task Group 120 (TG120) is developing ICRP recommendations for radiological protection for a wide range of radiation accidents and malicious events, complementing those given in ICRP Publication 146 (2020) for large nuclear accidents. The scope includes accidents involving criticalities, operating faults, and fires and explosions in nuclear facilities, inadvertent damage to sealed radiation sources, as well as malicious events, such as sabotage of nuclear facilities or materials, use of radiological dispersal devices, the contamination of food and drinking water supplies, and the deployment of nuclear weapons. A template has been designed to collate relevant information on a wide range of case studies and hypothetical malicious scenarios to ensure that the recommendations developed are broadly applicable and comprehensive. For all scenarios, a graded approach to protection is being taken, accepting that specific guidance may be required for some distinctive aspects, for example, protection during times of armed conflict. This paper provides an overview of the scenarios and scope of the work of TG120, including some of the radiological and non-radiological impacts of radiation emergencies, along the response and recovery timeline.

ICRP↗

Thermomagnetic generators for ultra-low-grade marine thermal energy harvesting

Low-grade thermal gradients in marine environments represent an underexploited energy source for autonomous sensing and monitoring. Converting such small temperature differences into usable electrical power remains a key challenge for ocean-deployed systems. We present a deployable thermomagnetic generator thoroughly characterized for marine-relevant energy harvesting. The device powers an internet-connected sensor and harvests ultra-low temperature differences akin to those at the ocean surface. It draws heat from water and rejects it to ambient air, operating optimally at a temperature difference (ΔT) of ~7.5 °C. Laboratory prototypes generated up to 6.7 mW at ΔT ~ 10 °C with gentle airflow (~1 m s -1 ). A separate controlled wave-tank demonstration validated stable operation and sensor powering under marine-like boundary conditions. Given its voltage and power margins, the generator could sustain multiple sensor nodes. Scalability and material assessments identify modular deployment and non-rare-earth alternatives as pathways toward practical marine energy harvesting and low-grade waste-heat recovery.

16 TIDAL AND WAVE POWER↗

Intrinsic property of defective β-Ga 2 O 3 to self-heal under ionizing irradiation

Damage evolution and phase stability in defective β-Ga 2 O 3 and an irradiation-converted γ-Ga 2 O 3 layer have been studied under ionizing irradiation at 300 K. By exploring athermal nonequilibrium processes in β-Ga 2 O 3 , we succeed in identifying a self-healing mechanism that enables recovery pre-existing damage, characterized by a recovery cross-section of ~0.17 nm 2 . Remarkably, this study further demonstrates that the crystallinity of the irradiation-converted γ-Ga 2 O 3 layer improves under ionizing irradiation. More importantly, X-ray diffraction analysis reveals that the highly-strained 𝛾 -phase transforms into a highly-crystalline structure without film disintegration, contrasting to that reported for isochronal annealing at 1000 K. The inelastic thermal spike calculations provide insights into the important effects of energy transfer to electrons in reordering the local atomic arrangement of both defective β- Ga 2 O 3 and 𝛾-Ga 2 O 3 . This behavior suggests a pathway for low-temperature crystallization, offering a promising strategy for fabricating ultrahigh-speed non-volatile memory devices.

36 MATERIALS SCIENCE↗

Recovery of Oxpure 612C-50 Coconut Carbon Particles Using Bump Arrays

Cyanide is used to leach gold from crushed ore (solid matrix) into a gold cyanide solution. The gold is extracted from the cyanide solution by adsorption onto activated carbon. The gold extraction process occurs when the activated coconut carbon is placed into tanks that contain the gold cyanide solution either in a batch process or into a continuous flow circuit. The coconut carbon is then removed from the solution for gold recovery. The use of the mesofluidic separation system (a deterministic lateral displacement system) can significantly reduce costs and waste generated from the process of removing the coconut carbon from the solution. In the coconut carbon recovery process used at many gold mines in Nevada, the gold is attached to carbon particles that are still in the cyanide liquor. The mesofluidic system can rapidly remove the gold bearing carbon particles from the cyanide liquor quickly and with no operating costs. The benefits include: • Reduce operational costs related to filtration and hydro-cyclones • Reduced acid usage for the elution gold stripping phase as only 25% of the fluids will follow the carbon particles to the final express lane when two mesofluidic systems are used in series This alternative particle removal techniques would be advantageous. A promising technique for removing larger particles from slurries is mesofluidic separation, similar to deterministic lateral displacement arrays or “bump” arrays [1] but operates at much larger flow rates. As described by Pease, et al. [2], “Bump arrays in deterministic lateral displacement devices separate large particles from small particles using arrays of staggered posts. Large particles, defined as those with radii larger than the distance between the edge of a post and the stagnation streamline from the next downstream post, must bump toward one side of the device, whereas particles smaller than this distance slalom from entrance to exit without net lateral displacement.” Unlike filters or sieves, the posts in the arrays that cause separation do not block or occlude particle flow but work because particles go around the posts. Unlike hydrocyclones separation, separation is not driven by particle density, because gravitational forces are unimportant to mesofluidic separation. Burns, et al., and Pease, et al., have shown that particles may be separated from complex suspensions, under turbulent flow conditions, and at industrially important flow rates [3-5]. They have also recently shown that mesofluidic devices may be arranged in series to increase separation performance [6]. In this paper, we evaluate the mesofluidic system for the separation of commercial OxPure GR 612 Charred Coconut shell particles as a proof of principle test for the rapid separation using the 1500 micron cut mesofluidic separator. We first describe the experimental system and conditions. We then present the experimental results. [1] Huang, L.R., E.C. Cox, R.H. Austin, J.C. Sturm. 2004. Continuous particle separation through deterministic lateral displacement. Science, 304, 987–990. https://doi.org/10.1126/science.1094567. [2] Pease L.F., J.A. Bamberger, C.A. Burns, and M.J. Minette. 2021. Large Particle Separation from Non-Newtonian Slurries using Bump Arrays. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-65904, V003T08A023. New York, New York: ASME. doi:10.1115/FEDSM2021-65904 [3] Burns C.A., T.G. Veldman, J. Serkowski, R.C. Daniel, X.-Y. Yu, M.J. Minette, L.F. Pease. 2021. Mesofluidic separation versus dead-end filtration. Separation and Purification Technology, 254, 117256. https://doi.org/10.1016/j.seppur.2020.117256. [4] Pease L.F., J.E. Serkowski, T.G. Veldman, J. Williams, X.-Y. Yu, M.J. Minette, J.A. Bamberger, C.A. Burns. 2021. Can Bump Arrays Separate Particles from Turbulent Flows?. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-67696, V003T08A024. New York, New York: ASME. doi:10.11

mesofluidic separation, slurry, bump array↗

Low thermal budget dopant activation in shallow junctions of implanted Si via Tunable plasma enhanced annealing

Low thermal budget (LTB) annealing has become increasingly critical for shallow junctions as semiconductor devices are scaled down. Plasma Enhanced Annealing (PEA) has emerged as a promising LTB annealing process, however its mechanisms remain unclear. In this study, arsenic and boron implanted silicon wafers were subjected to helium or argon ion bombardment generated by annealing plasmas under controlled ion energies and doses in a home-built annealing reactor. The structural and electrical changes were characterized by four-point probe measurements, secondary ion mass spectrometry, Raman spectroscopy and spectroscopic ellipsometry. A pronounced reduction in sheet resistance, accompanied by a decrease in the damage layer thickness demonstrates the surface selective annealing capability of PEA process. Comparative studies using He and Ar plasmas and related ion bombardment reveal a dependence of activation efficacy on both ion species and the dopant implantation profile. Furthermore, a multi-step annealing mechanism is proposed, consisting of an initial (low dose) structural recovery stage followed by the generation of “extended” defects and concluded at large doses by an enhanced dopant activation. The proposed annealing kinetics are thought to be controlled by ion flux, dose and energy. Finally, these results highlight PEA as an effective, surface-selective, LTB approach for shallow-dopant activation and near surface annealing, and provide mechanistic insights into PEA processes.

dopant activation↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Encapsulation Enhances the Quantum Coherence of a Solid‐State Molecular Spin Qubit

Spins within molecules benefit from the atomistic control of synthetic chemistry for the realization of qubits. One advantage is that the quantum superpositions of the spin states encoding the qubit can be coherently manipulated using electromagnetic radiation. The main challenge is the fragility of these superpositions when qubits are to partake of solid-state devices. We address this issue with a supramolecular approach for protecting molecular spin qubits against decoherence. The molecular qubit [Cr(ox)3]3- has been encapsulated inside the diamagnetic triple-stranded helicate [Zn2L3]4+ (L is a bis-pyrazolylpyridine ligand). The quantum coherence of the protected qubit is then analyzed with pulsed EPR spectroscopy and compared with the unprotected qubit, both in solution and in the solid state. Crucially, the spin-spin relaxation in the solid state has been examined within diamagnetic crystal lattices of the isostructural ([Al(ox)3]@[Zn2L3])+ or [Al(ox)3]3- assemblies, respectively, doped with the Cr3+ qubit in two different (<10%) concentrations. The study unveils a surprising increase of the phase memory time of the qubit upon encapsulation only in the solid. Spin-lattice relaxation times also exhibit a significant enhancement, as established from inversion recovery pulse sequences and from slow relaxation of the magnetization of the protected qubit, not featured by the free qubit.

Swain, Abinash↗

Fundamental advantages of multijunction thermoradiative cells

Thermoradiative (TR) cells convert heat to work through emission of thermal radiation. Multijunction thermoradiative cells have received little research interest due to the apparent overlap with energy harvesting limits. Through detailed balance formalism, the present study models both single- and multi-diode TR devices, establishing their performance limits and identifying key factors that influence efficiency. For single-junction TR cells, we derive a relationship for the optimal bandgap and show that higher emitter temperatures increase efficiency. When the receiver is at absolute zero temperature, multijunction TR cells have little advantage over the single-junction cell in terms of the maximum output power density. However, for higher receiver temperatures, the multijunction configuration demonstrates significant improvements in both power and efficiency through the optimization of the chemical potential and bandgap of each diode in the complete ensemble. A 500 K emitter and 300 K receiver TR system can achieve a 21.25% increase in efficiency and a 10% improvement in the power density with multijunction architecture compared to a single junction through chemical potential optimization. These findings suggest that multijunction TR cells offer a promising approach to advancing low-grade heat recovery technologies for efficient heat-to-work conversion.

30 DIRECT ENERGY CONVERSION↗

Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources.

Title: Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources. Abstract: The Mobile Hot Cell (MHC), currently under development by Idaho National Laboratory (INL) for the Off-Site Source Recovery Project (OSRP), is designed to help international partners meet the unique challenges of end-of-life radioactive material management. The MHC will provide a critical resource for countries that require assistance securing and disposing of Disused Sealed Radioactive Sources (DSRS) and orphaned sources in challenging environments, allowing these sources to be secured against misuse and nefarious activities. The MHC is a rapidly deployable system for conditioning and preparing end-of-life radioactive sources for transportation or storage. It is designed to handle sources of up to 1,000 Ci Co-60 equivalent while maintaining full radiological and biological containment. It will be deployable within 48 hours of an alert, making it ideal for emergency situations. The MHC features an operational suite for control, support racks for electronics, pneumatics, and welding systems, and a modular robust steel structure providing radiological shielding and internal robotic support. This design allows configurations for multiple device types to be conditioned and the ability to safely manage routine issues such as leaking or damaged sources. The MHC has been designed with the transportation challenges of rapid deployment to difficult environments in mind. The system weighs approximately 150,000 pounds, with individual systems breaking down into pieces not exceeding 20,000 pounds. Components are to be transportable on standard 20ft ISO containers, with shielding shells on 20ft flat racks. It is estimated that a total of eight containers and flat racks will be required. The use of 20ft containers, as opposed to 40ft containers, minimizes the impact on less developed road infrastructures, enabling the MHC to be positioned in constrained environments such as hospital parking lots. The system’s modularity also allows for deployment using smaller equipment, such as a 10-ton boom truck or forklift, which is crucial given the potential logistical challenges in different countries. This transportation strategy, evaluated in collaboration with Utah State University, ensures the MHC can be deployed via ground, rail, sea, or air, addressing the primary concern of international transport logistics.

99 - GENERAL AND MISCELLANEOUS↗

Protein Adhesion on Semi-Fluorinated Polystyrene Surfaces in Static and Dynamic Measurements

Reducing protein adhesion is a critical strategy in fouling-resistant material innovation, with broad applications spanning biomedical and healthcare devices, biosensors, industrial and environmental systems, and other important technological domains. Here, in this study, we elucidated protein adhesion behavior on polystyrene-based thin films by neutron reflectometry (NR) and quartz crystal microbalance with dissipation (QCM-D), using both lysozyme and bovine serum albumin (BSA) as model proteins. To this end, semifluorinated polystyrene thin films with gradient wettability and surface energy were fabricated through dry processing using plasma oxidation and gas-phase deposition. Although it is believed that a fully fluorinated alkyl chain offers extremely low surface energy, thus rejecting foulants, and has been used in many fouling-resistant surface designs, enhanced protein–surface interactions were observed consistently in NR and QCM-D results, due to the combined effects of surface morphology and chemistry. On the contrary, depositing shorter fluorinated silane onto a hydrophilic PS surface contributed to a more homogeneous nanoscale fluorine coating, resulting in less initial protein adsorption and improved surface recovery. Comparative analysis of proteins with different sizes on the nanopatterned semifluorinated surface revealed the influence of molecular characteristics on surface interactions. Lysozyme, being smaller and more compact, showed faster adsorption kinetics and higher surface coverage but largely reversible binding, whereas BSA, with its larger and more flexible structure, formed broader and more stable interfacial layers. This study fills the gap in understanding protein adhesion within the range of hydrophobicity (water contact angle ∼90°), as current strategies often associate with extreme hydrophilic and superhydrophobic surfaces due to hydration or low-surface-energy rejection mechanisms, respectively. It also provides in-depth insights into current combinatorial fouling-resistant surface design.

Yuan, Yue [Oak Ridge National Laboratory (ORNL), O↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Testing of Novel Semiconductor Opening Switches Using Magnetic Switching

The performance of semiconductor opening switch (SOS) diodes with different doping profiles is assessed with the primary aim of enhancing or substituting hard-to-find devices. SOS devices are capable of providing long lifetime, gigawatt level pulses in generators with risetimes on the nanosecond scale with pulse widths on the order of 20 ns. An experimental testbed is described which allows for rapid testing of diodes with control of the forward pumping time which is a crucial parameter of SOS diodes. A saturable pulse transformer provides both the initial voltage multiplication and reverse current pulse required to drive SOS diodes. Voltage multiplication ratios of 16:1 were achieved with a modest charging voltage of 800 V and simple circuitry. With current densities of up to 1.4 kA ⋅ cm -2 , the testbed produces 10 kV output pulses into a 56 Ω load with a pulsewidth of 16 ns and delivered power of up to 1.9 MW. These novel devices are compared to legacy SOS diodes originating from Russia, with one of the profiles yielding increased performance. Finally, these profiles are studied in hopes of creating manufacturing demand to augment the availability of these useful devices.

drift step recovery diodes↗

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

The Federal Radiological Monitoring and Assessment Center (FRMAC) is an operational center, available on request by the Department of Homeland Security (DHS) to respond to nuclear and radiological incidents as described in the National Response Framework (NRF). Under the Federal Interagency Operational Plan for Response and Recovery’s Nuclear/Radiological Annex, the U.S. Department of Energy (DOE) has the responsibility to maintain the operational readiness of the FRMAC during the emergency phase of an event. FRMAC is initially established and managed by the Nuclear Emergency Support Team (NEST) and serves as an interagency operations center with representatives from various federal, state, and local radiological response organizations. The purpose of the FRMAC is to assist state, local, tribal, and territorial governments (SLTT) in their mission to protect the health and well-being of their citizens with: • Verified radiation measurements. • Interpretations of radiation distributions based on Environmental Protection Agency (EPA), Food and Drug Administration (FDA), or local Protective Action Guidelines (PAGs). • Characterization of overall radiological conditions. Once a declaration to respond to a radiological emergency has been made, the National Nuclear Security Administration (NNSA) Headquarters will coordinate the response in consultation with the cognizant NNSA Regional Coordinating Office (RCO). Each of the eight RCOs maintain a 24-hour response capability for radiological emergencies that may occur in states served by its region. When a FRMAC is established, it operates under the parameters of the Incident Command System (ICS), as defined in the National Incident Management Systems (NIMS) construct. The Consequence Management Home Team (CMHT) will be activated immediately during normal business hours (Pacific Time Zone), and within two hours otherwise. The Consequence Management Response Team (CMRT) is prepared for deployment within six hours after activation. Along with the assets, FRMAC provides an operational framework for coordinating of all federal off-site radiological monitoring and assessment activities during a response to a radiological emergency to support the coordinating agency and SLTT governments. Potential radiological emergencies that fall within FRMAC vary widely in terms of the area affected, the nature of the contamination, and the scope of the government’s response. Detonation of a nuclear device, accidental release of radiation from a nuclear power plant, and a terrorist threat are just a few of the many possible scenarios FRMAC must be prepared to address. Through all this, supporting the state, local, and tribal organizations in the protection of the public remains the primary goal of the federal response.

54 ENVIRONMENTAL SCIENCES↗