Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REAGENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Method and apparatus for eliminating luminol interference material

A method and apparatus for removing porphyrins from a fluid sample which are unrelated to the number of bacteria present in the sample and prior to combining the sample with luminol reagent to produce a light reaction is disclosed. The method involves a pre-incubation of the sample with a dilute concentration of hydrogen peroxide which inactivates the interfering soluble porphyrins. Further, by delaying taking a light measurement for a predetermined time period after combining the hydrogen peroxide-treated water sample with a luminol reagent, the luminescence produced by the reaction of the luminol reagent with ions present in the solution, being short lived, will have died out so that only porphyrins within the bacteria which have been released by rupturing the cells with the sodium hydroxide in the luminol reagent, will be measured. The measurement thus obtained can then be related to the concentration of live and dead bacteria in the fluid sample.

Jeffers, E. L.↗

Colorimetric Solid Phase Extraction (CSPE): Using Color to Monitor Spacecraft Water Quality

In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the presence of high levels of iodine in water can cause taste and odor issues that result in decreased water consumption by the crew. There are also concerns about potential impacts on thyroid function following exposure to high levels of iodine. With silver, there is a risk of developing argyria, an irreversible blue-gray discoloration of the skin, associated with long term consumption of water containing high concentrations of silver. The need to ensure that safe, effective levels of biocide are maintained in the potable water systems on the ISS provides a perfect platform for evaluating the suitability of CSPE technology for in-flight water quality monitoring. This paper provides an overview of CSPE technology and details on the silver and iodine methods used in the CWQMK. It also reports results obtained during in-flight analyses performed with the CWQMK and briefly discusses other potential applications for CSPE technology in both the spacecraft and terrestrial environments.

Gazda, Daniel B.↗

Renal function and water balance

Routine urinalyses, including microscopic examination, were performed periodically. Protein, sugar, and pH were determined using Hema-Combistix reagent strips manufactured by the Ames Company. When the presence of albumin was suspected from a doubtful reaction of the reagent strip, the sulfasalicylic acid turbidity test for protein was also done. Likewise, to rule out a false positive reaction for glucose, the presence or absence of the latter was also determined using Clinitest Reagent Tablets (Ames). Specific gravity was determined using an urinometer, and acetate with Acetest Tablets (Ames Company). Serum and urinary creatinine clearance were determined once every three days. Methods used in all of the above tests were taken from standard Navy laboratory manuals published by the U. S. Naval Medical School, National Naval Medical Center, Bethesda, Md.

CREATININE↗

Development of a method for the determination of iodine in spacecraft potable water

A one-reagent indicator solution has been prepared for the analysis of iodine concentrations in the range of 0.5 to 12 mg/1 of I2 for use on the potable water proposed for the Skylab project. The indicator solution was formulated to contain the minimum concentrations of reagents for optimum analytical performance. Performance tests indicated that the reagent is stable for at least six months and is reliable for the determination of I2 under a variety of conditions of I(-) concentrations and sample temperatures. Visual estimations as low as 0.5 mg/1 were obtained without difficulty and the stability of the developed color allows visual determinations from 0.5 to 12 mg/1 of I2 with a relatively small error.

Whittle, G. P.↗

Tagging insulin in microgravity

Knowing the exact subcellular sites of action of insulin in the body has the potential to give basic science investigators a basis from which a cause and cure for this disease can be approached. The goal of this project is to create a test reagent that can be used to visualize these subcellular sites. The unique microgravity environment of the Shuttle will allow the creation of a reagent that has the possibility of elucidating the subcellular sites of action of insulin. Several techniques have been used in an attempt to isolate the sites of action of items such as insulin. One of these is autoradiography in which the test item is obtained from animals fed radioactive materials. What is clearly needed is to visualize individual insulin molecules at their sites of action. The insulin tagging process to be used on G-399 involves the conjugation of insulin molecules with ferritin molecules to create a reagent that will be used back on Earth in an attempt to elucidate the sites of action of insulin.

Dobeck, Michael↗

Fatigue damage study in aluminum-2024 T3 alloys

The grain structure of aluminum 2024, a commonly used commercial alloy is investigated, and these findings are correlated with the fatigue property of the material. Samples of aluminum 2024 were polished and etched in different reagents. Optical micrographs (at 500X) of samples etched in Keller's reagent revealed grain boundaries as well as some particles present in the microstructure. Normal x-ray scans of samples etched for different intervals of time in Keller's reagent indicate no significant variations in diffraction peak positions; however, the width of the rocking curve increased with the time of etching. These results are consistent with the direct dependence of the width of the rocking curve on the range of grain orientation. Etching removes the preferred orientation layer of the sample produced by polishing; thereby, causing the width to increase.

Ferguson, Milton W.↗

Absorbent Pads for Containment, neutralization, and clean-up of environmental spills containing chemically-reactive agents

A pad for cleaning up liquid spills is described which contains a porous surface covering, and an absorbent interior containing chemically reactive reagents for neutralizing noxious chemicals within the spilled liquid. The porous surface and the absorbent component would normally consist of chemically resistant materials allowing tentative spill to pass. The absorbent interior which contains the neutralizing reagents can but is not required to be chemically resilient and conducts the liquid chemically reactive reagents where the dangerous and undesirable chemicals within the chemical spill are then neutralized as well as removed from the premises.

Davis, Dennis D.↗

Enhancing Adhesion: Relative Merits of Different Approaches

Adhesive performance is improved mainly by manipulation of the bimaterials interface zone, which is only a few molecules thick. There are three approaches to enhancement of interfacial adhesion at the molecular level. They are 1) changing the nonchemically bonded interactions across the interface from weak ones to strong ones, 2) making the true interfacial area much larger than the simple geometric area, and 3) inducing chemical bonding between the two materials forming the interface. Our goal this summer was to question some of the built-in assumptions contained within these approaches and to determine the most promising approach, both theoretically and practically, for enhancing adhesion in NASA structures. Our computations revealed that all three of these approaches have, in theory, the potential to enhance molecular adhesion approximately ten-fold. Experiments, however, revealed that this excellent level of enhancement is not likely to be reached in practice. Each approach was found to be severely limited by practical problems. In addition, some of the built-in assumptions associated with these approaches were found to be insufficient or inadequate. The first approach, changing the nonchemically bonded interactions from weak to strong, Is an example of one containing inadequate assumptions. The extensive literature on intermolecular interactions, based on solution studies, shows that certain functional group pairs interact much more strongly than others. It has always been assumed that these data can be reliably extended to systems where only one member of the pair is in solution and the other Is contained in a solid surface. Our experiments this summer demonstrated that solution data do not adequately predict the strength of functional group interaction at the solid-liquid interface. Furthermore, the strong solvents needed to dissolve the monomers or polymers to which the functional groups of interest are attached compete successfully with the solid surface for the functional group. As a result, functional groups in solution cannot pair with the complementary groups in the solid surface, and the expected enhancement of nonchemically bonded interactions is not realized. The second approach, increasing the true interfacial area, is an example of one containing inadequate assumptions and suffering from numerous practical problems. First, practitioners have assumed that material removal, such as bead blasting or etching, increases true surface area (and therefore interfacial area) in a meaningful way. Our geometric analysis demonstrated that removal methods increase area by a factor of two at most. To increase interfacial area by an order of magnitude or more. a thin layer of high porosity must be added to the substrate surface prior to application of the adhesive phase. Consistent with this finding, we attempted to create a thin layer of rigid, highly porous glass on the surface of our smooth glass substrate by means of sol-gel technology. We were unable to surmount a wide variety of practical problems and obtained only collapsed, nonporous layers. Thus this approach, appealing in principle, would require long term development and is not promising in the near term. The third approach, inducing chemical bonding at the interface, is an example of one having neither inadequate assumptions nor insurmountable practical problems. When silicate glass is the substrate, there are only a few chemical reactions that can be successfully conducted to create these chemical bonds, and these reactions usually involve silicon-containing reagents. We compared the silazane reagents to the silane reagents and found through experiment that the silazanes react with the glass surface much more readily, and under milder conditions, than the silanes. The functional groups attached to the glass surface by silazane reactions were not able to be removed by solvent extraction, elevated temperature exposure, or mechanical action. This clearly indicates that the formation of chemical bonds at the interface is the most effective approach for enhancing molecular adhesion.

Penn, L. S.↗

Absorbent pads for Containment, Neutralization, and Clean-Up of Environmental Spills Containing Chemically-Reactive Agents

A pad for cleaning up liquid spills is described which contains a porous surface covering, and an absorbent interior containing chemically reactive reagents for neutralizing noxious chemicals within the spilled liquid. The porous surface and the absorbent component would normally consist of chemically resistant materials allowing tentative spill to pass. The absorbent interior which contains the neutralizing reagents can but is not required to be chemically resilient and conducts the liquid chemical spill towards the absorbent interior containing the chemically reactive reagents where the dangerous and undesirable chemicals within the chemical spill are then neutralized as well as removed from the premises.

Davis, Dennis D.↗

Recycle of Inorganic Nutrients for Hydroponic Crop Production Following Incineration of Inedible Biomass

Recovery of resources from waste streams is essential for future implementation and reliance on a regenerative life support system. The major waste streams of concern are from human activities and plant wastes. Carbon, water and inorganics are the primary desired raw materials of interest. The goal of resource recovery is maintenance of product quality to insure support of reliable and predictable levels of life support function performance by the crop plant component. Further, these systems must be maintained over extended periods of time, requiring maintenance of nutrient solutions to avoid toxicity and deficiencies. Today, reagent grade nutrients are used to make nutrient solutions for hydroponic culture and these solutions are frequently changed during the life cycle or sometimes managed for only one crop life cycle. The focus of this study was to determine the suitability of the ash product following incineration of inedible biomass as a source of inorganic nutrients for hydroponic crop production. Inedible wheat biomass was incinerated and ash quality characterized. The incinerator ash was dissolved in adequate nitric acid to establish a consistent nitrogen concentration in all nutrient solution treatments. Four experimental nutrient treatments were included: control, ash only, ash supplemented to match control, and ash only quality formulated with reagent grade chemicals. When nutrient solutions are formulated using only ash following-incineration of inedible biomass, a balance in solution is established representing elemental retention following incineration and nutrient proportions present in the original biomass. The resulting solution is not identical to the control. This imbalance resulted in suppression of crop growth. When the ash is supplemented with nutrients to establish the same balance as in the control, growth is identical to the control. The ash appears to carry no phytotoxic materials. Growth in solution formulated with reagent grade chemicals but matching the quality of the ash only treatment resulted in growth similar to that of the ash only treatment. The ash product resulting from incineration of inedible biomass appears to be a suitable form for recycle of inorganic nutrients to crop production.

Bubenheim, David L.↗

Application of Colorimetric Solid Phase Extraction (C-SPE) to Monitoring Nickel(II) and Lead(II) in Spacecraft Water Supplies

Archived water samples collected on the International Space Station (ISS) and returned to Earth for analysis have, in a few instances, contained trace levels of heavy metals. Building on our previous advances using Colorimetric Solid Phase Extraction (C-SPE) as a biocide monitoring technique, we are devising methods for the low level monitoring of nickel(II), lead(II) and other heavy metals. C-SPE is a sorption-spectrophotometric platform based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent that are then quantified on the surface of the membrane using a diffuse reflectance spectrophotometer. Along these lines, we have determined nickel(II) via complexation with dimethylglyoxime (DMG) and begun to examine the analysis of lead(II) by its reaction with 2,5- dimercapto-1,3,4-thiadiazole (DMTD) and 4-(2- pyridylazo)-resorcinol (PAR). These developments are also extending a new variant of C-SPE in which immobilized reagents are being incorporated into this methodology in order to optimize sample reaction conditions and to introduce the colorimetric reagent. This paper describes the status of our development of these two new methods.

Diaz, Neil C.↗

Multiplexed Colorimetric Solid-Phase Extraction

Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

Gazda, Daniel B.↗

Ordered Nanostructures Made Using Chaperonin Polypeptides

A recently invented method of fabricating periodic or otherwise ordered nanostructures involves the use of chaperonin polypeptides. The method is intended to serve as a potentially superior and less expensive alternative to conventional lithographic methods for use in the patterning steps of the fabrication of diverse objects characterized by features of the order of nanometers. Typical examples of such objects include arrays of quantum dots that would serve as the functional building blocks of future advanced electronic and photonic devices. A chaperonin is a double-ring protein structure having a molecular weight of about 60 plus or minus 5 kilodaltons. In nature, chaperonins are ubiquitous, essential, subcellular structures. Each natural chaperonin molecule comprises 14, 16, or 18 protein subunits, arranged as two stacked rings approximately 16 to 18 nm tall by approximately 15 to 17 nm wide, the exact dimensions depending on the biological species in which it originates. The natural role of chaperonins is unknown, but they are believed to aid in the correct folding of other proteins, by enclosing unfolded proteins and preventing nonspecific aggregation during assembly. What makes chaperonins useful for the purpose of the present method is that under the proper conditions, chaperonin rings assemble themselves into higher-order structures. This method exploits such higher-order structures to define nanoscale devices. The higher-order structures are tailored partly by choice of chemical and physical conditions for assembly and partly by using chaperonins that have been mutated. The mutations are made by established biochemical techniques. The assembly of chaperonin polypeptides into such structures as rings, tubes, filaments, and sheets (two-dimensional crystals) can be regulated chemically. Rings, tubes, and filaments of some chaperonin polypeptides can, for example, function as nano vessels if they are able to absorb, retain, protect, and release gases or chemical reagents, including reagents of medical or pharmaceutical interest. Chemical reagents can be bound in, or released from, such structures under suitable controlled conditions. In an example of a contemplated application, a two-dimensional crystal of chaperonin polypeptides would be formed on a surface of an inorganic substrate and used to form a planar array of nanoparticles or quantum dots. Through genetic engineering of the organisms used to manufacture the chaperonins, specific sites on the chaperonin molecules and, thus, on the two-dimensional crystals can be chemically modified to react in a specific manner so as to favor the deposition of the material of the desired nanoparticles or quantum dots. A mutation that introduces a cysteine residue at the desired sites on a chaperonin of Sulfolobus shibatae was used to form planar arrays of gold nanoparticles (see figure).

Trent, Jonathan↗

Development of self extinguishing Durette and/or Nomex fabric

A treatment was developed for Nomex or Durette fabric which renders it self-extinguishing in a 70% oxygen, 30% nitrogen atmosphere at 5 psia. The treatment does not degrade the physical and textile properties of the fabric excessively and does not outgas or have an objectional odor. The treatment is permanent and does not lose its fire protecting qualities after laundering. The treatment utilizes a mixture of formaldehyde, phosphorous acid, and tri-methyl phosphate in methanol. The cloth to be treated is held in a boiling solution of the above reagents for 24 hours, removed, air dried, and then heated to 120 C in a circulating air oven for 90 minutes. The treatment turns Nomex a pale yellow but does not have an appreciable effect on drape or hand. One inch wide strips of treated cloth failed in tension at 192 lbs, while untreated controls broke at 215 lbs. To remove any excess reagents, the cloth is processed in a home laundry through one wash and dry cycle without the use of any detergents. The thermal shrinkage of the treated material is 23% compared to a control of 40% for unwashed Stern Nomex HT 90-40.

Source record↗

An investigation of the preparation of high molecular weight perfluorocarbon polyethers

High molecular weight perfluorocarbon polyether gums were obtained by photolysis of perfluorodienes and discyl fluorides containing a perfluorocarbon polyether backbond. The materials obtained are represented by chemical formulas. A method was developed whereby reactive acyl fluoride and trifluorovinyl end groups are converted into inert structures. In order to investigate the possible preparation of difunctional molecules which may be useful in polymer synthesis, the reactions of hexafluoropropene oxide (HFPO) with Grignard and organolithium reagents have been studied. Reactions of various nucleophilic reagents with HFPO were also investigated.

Watts, R. O.↗

Water system virus detection

A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

Fraser, A. S.↗

Development of a chemiluminescent and bioluminescent system for the detection of bacteria in wastewater effluent

Automated chemiluminescent and bioluminescent sensors were developed for continuous monitoring of microbial levels in wastewater effluent. Development of the chemiluminescent system included optimization of reagent concentrations as well as two new techniques which will allow for increased sensitivity and specificity. The optimal reagent concentrations are 0.0025 M luminol and 0.0125 M sodium perborate in 0.75N sodium hydroxide before addition of sample. The methods developed to increase specificity include (1) extraction of porphyrins from bacteria collected in a filter using 0.1N NaOH - 50 percent Ethanol, and (2) use of the specific reaction rate characteristics for the different luminol catalysts. Since reaction times are different for each catalyst, the reaction can be made specific for bacteria by measuring only the light emission from the particular reaction time zone specific for bacteria. Developments of the bioluminescent firefly luciferase system were in the area of flow system design.

Thomas, R. R.↗

Automated single-slide staining device

An automatic single-slide Gram staining device is described. A timer-actuated solenoid controls the dispensing of gentian violet, Gram iodine solution, decolorizer, and 1% aqueous safranin in proper sequence and for the time required for optimum staining. The amount of stain or reagent delivered is controlled by means of stopcocks below each solenoid. Used stains and reagents can be flushed automatically or manually. Smears Gram stained automatically are equal in quality to those prepared manually. The time to complete one Gram cycle is 4.80 min.

Wilkins, J. R.↗