At least 55 records · Page 3

The coronal electron density distribution determined from dual-frequency ranging measurements during the 1991 solar conjunction of the Ulysses spacecraft

Dual-frequency ranging and Doppler measurements were conducted in support of the Ulysses Solar Corona Experiment (SCE) at and around the spacecraft's first solar conjunction in 1991 August. The differential group delay time between range codes on the two downlink carrier signals at the wavelengths 13.1 and 3.6 cm, a direct measure of the total electron content between spacecraft and ground station, was used to derive the electron density distribution in the solar corona. Linear power-law representations of the coronal electron density were derived for the range of solar distances from 4 solar radii to 40 solar radii on both sides of the Sun. The corona was found to be very nearly symmetric; the radial falloff exponent being 2.54 +/- 0.05 for occultation ingress (east solar limb) and 2.42 +/- 0.05 for egress (west limb), respectively. The departure of these exponents from the inverse equare relation implies that significant solar wind acceleration is occurring within the radial range of the observations. The electron density level was found to be considerably lower than that observed during the 1988 December solar occultation of Voyager 2. Although the smoothed sunspot number R(sub z) (a standard indicator of solar activity) was almost the same in 1988 December and 1991 August, the mean electron density at 20 solar radii was found to be 1.7 +/- 0.1 x 10(exp 3)/cu cm during the Ulysses conjunction, a decline by almost a factor of 4 from the value obtained during the Voyager conjunction.

Bird, M. K.↗

High dynamic range measurement of spectral responsivity and linearity of a radiation thermometer using a super-continuum laser and LEDs

To realize the temperature scale above the freezing point of silver according to the definition of ITS-90, the dynamic range of the spectral responsivity is one of the most important factors which limit its uncertainty. When the residual spectral response at both side bands of a spectral band is not negligible, a significant uncertainty can be caused by a low dynamic range of the spectral responsivity measurement. In general, incandescent lamps are used to measure the spectral responsivity and the linearity. The dynamic range of the spectral responsivity measurement is often limited by a trade-off with the desired spectral resolution, which is less than 6 decades. Nonlinearity is another limiting fact of uncertainties of the temperature scale. Tungsten lamps have disadvantage in the nonlinearity measurements in terms of adjustability of radiance level and spectral selectivity. We report spectral responsivity measurements of which the measurable dynamic range is enhanced 50 times after replacing a QTH lamp with a super continuum laser. We also present a spectrally selected linearity measurement over a wide dynamic range using high-brightness light emitting diode arrays to observe a slight saturation of linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise orbit determination of high-earth elliptical orbiters using differenced Doppler and range measurements

Recent advances in Deep Space Network station calibration methods have led to renewed interest in the use of differenced Doppler and range data types for interplanetary navigation. Described here is an orbit determination error analysis of the performance of these differenced data types when used with conventional two-way Doppler for precise navigation of High-Earth Orbiters. Three highly elliptical Earth orbits are investigated, with apogee heights on the order of 20,000 km, 70,000 km, and 156,000 km. Results indicate that the most significant navigational accuracy improvements, relative to the performance obtained from two way Doppler alone, are achieved for the lowest altitude orbit by using differenced Doppler measurements with two way Doppler (assuming that spacecraft onboard downlink antennas have no ground footprint limitation in the near-apogee regime). In the case of the two higher altitude orbits, accuracy improvements over Doppler-only performance, although less dramatic, are also achieved when differenced range measurements are combined with two-way Doppler.

Estefan, J. A.↗

Precise orbit determination of high-earth elliptical orbiters using differenced Doppler and ranging measurements

Recent advances in Deep Space Network station calibration methods have led to renewed interest in the use of differenced Doppler and range data types for interplanetary navigation. Described here is an orbit determination error analysis of the performance of these differenced data types when used with conventional two-way Doppler for precise navigation of High-Earth Orbiters. Three highly elliptical earth orbits are investigated, with apogee heights on the order of 20,000 km, 70,000 km, and 156,000 km. Results indicate that the most significant navigational accuracy improvements, relative to the performance obtained from two way Doppler alone, are achieved for the lowest altitude orbit by using differenced Doppler measurements with two way Doppler (assuming that spacecraft onboard downlink antennas have no ground footprint limitation in the near-apogee regime). In the case of the two higher altitude orbit accuracy improvements over Doppler-only performance, although less dramatic, are also achieved when differenced range measurements are combined with two-way Doppler.

Estefan, Jeff A.↗

Measuring Range Anxiety: the Substitution-Emergency-Detour (SED) Method

Range anxiety has been widely recognized as a critical barrier for battery electric vehicles (BEV), but its measurement method is lacking. Such a knowledge gap makes it difficult to analyse the competiveness of and the demand for BEVs. This study develops the Substitution-Emergency-Detour (SED) method to measure the range anxiety cost, and conducts sensitivity analysis of range anxiety cost with respect to nine factors. It is found that the most effective ways to reduce range anxiety are reducing driving intensity, increasing the vehicle range, extending the vehicle range with better charging infrastructure. Better household vehicle flexibility and less range uncertainty can also significantly reduce range anxiety. The SED method and the numerical results are expected to contribute to better understanding of the range anxiety barrier and the BEV demand.

33 ADVANCED PROPULSION SYSTEMS↗

Precise orbit determination of high-earth elliptical orbiters using differenced Doppler and ranging measurements

Recent advances in NASA's Deep Space Network station calibration methods have led to renewed interest in the use of differenced radiometric data types for interplanetary navigation, particularly differenced Doppler and range. An orbit determination error analysis which compares the performance of these differenced data types when used in concert with conventional two-way Doppler for precise navigation of high-earth orbiters is described. Three highly elliptical orbits are investigated, with apogee heights on the order of 20,000 km, 70,000 km, and 156,000 km. The analysis assumes that each orbiter's downlink antenna has no ground footprint limitation in the near apogee regime. Results indicate that the most significant navigational accuracy improvements are seen for the lowest-altitude orbit by using differenced Doppler measurements in conjunction with two-way Doppler. The results for the two higher-altitude orbits, although less dramatic, suggest that accuracy improvements can also be achieved when differenced range measurements are combined with two-way Doppler.

Estefan, Jeff A.↗

Measurement of the refractive index dispersion of As{sub 2}Se{sub 3} bulk glass and thin films prior to and after laser irradiation and annealing using prism coupling in the near- and mid-infrared spectral range

The prism coupling technique has been utilized to measure the refractive index in the near- and mid-IR spectral region of chalcogenide glasses in bulk and thin film form. A commercial system (Metricon model 2010) has been modified with additional laser sources, detectors, and a new GaP prism to allow the measurement of refractive index dispersion over the 1.5-10.6 {mu}m range. The instrumental error was found to be {+-}0.001 refractive index units across the entire wavelength region examined. Measurements on thermally evaporated AMTIR2 thin films confirmed that (i) the film deposition process provides thin films with reduced index compared to that of the bulk glass used as a target, (ii) annealing of the films increases the refractive index of the film to the level of the bulk glass used as a target to create it, and (iii) it is possible to locally increase the refractive index of the chalcogenide glass using laser exposure at 632.8 nm.

36 MATERIALS SCIENCE↗

Laser range measurements using non-Gaussian pulse shapes

Many optical ranging systems currently use laser pulses of approximately Gaussian shape with widths of a few nanoseconds or less. The present paper shows that a substantial improvement in accuracy can be obtained for a given pulse length by means of laser ranging systems using conventional length (long) pulses with a sharp leading edge pulse distribution. The accuracy in such a case will improve roughly linearly with the signal strength. Order statistics is used to estimate the round-trip level travel time from the arrival time of the earliest photoelectron.

Ghigo, F. D.↗

Measurement range of phase retrieval in optical surface and wavefront metrology

Phase retrieval employs very simple data collection hardware and iterative algorithms to determine the phase of an optical field. We have derived limitations on phase retrieval, as applied to optical surface and wavefront metrology, in terms of the speed of beam (i.e., f-number or numerical aperture) and amount of aberration using arguments based on sampling theory and geometrical optics. These limitations suggest methodologies for expanding these ranges by increasing the complexity of the measurement arrangement, the phase-retrieval algorithm, or both. We have simulated one of these methods where a surface is measured at unusual conjugates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geophysical interpretation of satellite laser ranging measurements of crustal movement in California

As determined by satellite laser ranging the rate of contraction of a 900 kilometer baseline between sites located near Quincy in northern California and San Diego in southern California is about 61 to 65 mm/yr with a formal uncertainty of about 10 mm/yr. The measured changes in baseline length are a manifestation of the relative motion between the North America and Pacific tectonic plates. This long baseline result is compared to measurements made by more conventional means on shorter baselines. Additional information based on seismicity, geology, and theoretical modelling is also analyzed. Deformation lying within a few tens of kilometers about the major faults in southern California accounts for most, but not all of the observed motion. Further motion is attributable to a broader scale deformation in southern California. Data suggesting crustal movements north of the Garlock fault, in and near the southern Sierra Nevada and local motion at an observatory are also critically reviewed. The best estimates of overall motion indicated by ground observations lie between 40 and 60 mm/yr. This lies within one or two standard deviations of that deduced by satellite ranging but the possibility of some unresolved deficit cannot be dismissed. The long time scale RM2 plate tectonic model of Minster and Jordan predicts a contraction between 47 and 53 mm/yr depending on the extension rate of the Basin and Range. Thus the ground based observations, satellite laser ranging (SLR) results, and RM2 rates differ at about the 10 mm/yr level and are consistent with one another within the data and model uncertainties.

Cohen, S. C.↗

Application of the Two-Step Filter to Process Ranging Measurements for Relative Navigation in an Elliptical Orbit

This estimator breaks a nonlinear estimation problem into a set of over determined 'first step' states which are linear in the observations and 'second step' states which are ultimately the states of interest. Linear estimation methods are applied to filter the observations and produce the optimal first step state estimate. The 'second step' states are obtained through iterative nonlinear parameter estimation considering the first step states as observations. It has been shown that this process exactly minimizes the least squares cost function for static problems and provides a better solution than the iterated extended Kalman filter (EKF) for dynamic problems. The two step filter is applied in this paper to process range and range rate measurements between the two spacecraft. Details of the application of the two step estimator to this problem will be given, highlighting the use of a test for ill-conditioned covariance estimates that can result from the first order covariance propagation. A comparison will be made between the performance of the two step filter and the IEKF.

Garrison, James L.↗

Receiver performance of laser ranging measurements between the Lunar Observer and a subsatellite for lunar gravity studies

The optimal receiver for a direct detection laser ranging system for slow Doppler frequency shift measurement is shown to consist of a phase tracking loop which can be implemented approximately as a phase lock loop with a 2nd or 3rd order loop filter. The laser transmitter consists of an AlGaAs laser diode at a wavelength of about 800 nm and is intensity modulated by a sinewave. The receiver performance is shown to be limited mainly by the preamplifier thermal noise when a silicon avalanche photodiode is used. A high speed microchannel plate photomultiplier tube is shown to outperform a silicon APD despite its relatively low quantum efficiency at wavelengths near 800 nm. The maximum range between the Lunar Observer and the subsatellite for lunar gravity studies is shown to be about 620 km when using a state-of-the-art silicon APD and about 1000 km when using a microchannel plate photomultiplier tube in order to achieve a relative velocity measurement accuracy of 1 millimeter per second. Other parameters such as the receiver time base jitter and drift also limit performance and have to be considered in the design of an actual system.

Davidson, Frederic M.↗

Ultra-sensitive transducer advances micro-measurement range

An ultrasensitive piezoelectric transducer, that converts minute mechanical forces into electrical impulses, measures the impact of micrometeoroids against space vehicles. It has uniform sensitivity over the entire target area and a high degree of stability.

Rogallo, V. L.↗

Trial of a slant visual range measuring device

Each year, fog at airports renders some landing operations either difficult or impossible. The visibility that a pilot of a landing aircraft can expect is in that case the most important information. It could happen that the visibility versus the altitude is constantly decreasing or increasing. However, it is not possible to distinguish this with the existing sensors at an airport. If the visibility is decreasing with the altitude, one has the worst case - ground fog. The standard visibility sensor, the transmissometer, determines only the horizontal visual range, which will be underestimated in comparison with the real visibility a pilot has on his landing approach. Described here is a new technique to measure the slant visual range, making use of a slant scanning device - an eye-safe laser radar. A comparison with commercial visibility sensors shows that it is possible to measure visibilities with the slant looking laser radar in the range from 50 meters up to 2000 meters and even distinguish inhomogenities like ground fog.

Streicher, J.↗

Variation of fractional electron density fluctuations inside 40 R(sub 0) observed by Ulysses ranging measurements

The first measurements of fractional electron density fluctuations delta-n(sub e)/n(sub e), where delta-n(sub e) is rms electron density fluctuation and n(sub e) is the mean electron density, have been carried out inside 40 R(sub 0) using 1991 Ulysses dual-frequency S- and X-band (13 and 3.6 cm) ranging (time delay) measurements. In the frequency band of approximately 6 x 10(exp -5) - 8 x 10(exp -4) Hz (periods of 20 min to 5 hr), delta-n(sub e)/n(sub e) varies from a high near 20% in the slow wind close to the neutral line to a low of 1% in the fast wind far from the neutral line. For spatial wavenumber K approximately = 1.4 x 10(exp -6)/km (period of 5 hr at 250 km/s), delta-n(sub e)/n(sub e) is essentially independent of heliocentric distance over 0.03-1.0 AU in the slow wind; it is a factor of 30 lower in the fast wind than in the slow wind inside 0.1 AU, but exhibits dramatic growth with heliocentric distance inside 0.3 AU. This latter result reinforces current views of the evolution of MHD turbulence and the association of Alfven waves with high speed streams based on in situ fields and particles measurements beyond 0.3 AU. That regions of enhanced density fluctuations near or above the neutral line coincide with regions of enhanced density confirms previous conclusions that they are the interplanetary manifestation of the heliospheric current sheet and extensions of coronal streamers. While the regions of enhanced density fluctuations lie within those of enhanced density, they have boundaries that are distinctly more abrupt, suggesting the separation of plasma of different nature and origin.

Woo, Richard↗

Ballistic Range Measurements of Stagnation-Point Heat Transfer in Air and in Carbon Dioxide at Velocities up to 18,000 Feet Per Second

A new technique for measuring heat-transfer rates on free-flight models in a ballistic range is described in this report. The accuracy of the heat-transfer rates measured in this way is shown to be comparable with the accuracy obtained in shock-tube measurements. The specific results of the present experiments consist of measurements of the stagnation-point heat-transfer rates experienced by a spherical-nosed model during flight through air and through carbon dioxide at velocities up to 18,000 feet per second. For flight through air these measured heat-transfer rates agree well with both the theoretically predicted rates and the rates measured in shock tubes. the heat-transfer rates agree well with the rates measured in a shock tube. Two methods of estimating the stagnation-point heat-transfer rates in carbon dioxide are compared with the experimental measurements. At each velocity the measured stagnation-point heat-transfer rate in carbon dioxide is about the same as the measured heat-transfer rate in air.

Yee, Layton↗