Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quantum dot lightning detection and warning system and method

A quantum dot (QD) lightning detection and warning (LDW) system and method. This LDW system and method find broader applicability to spark and other transient optical event detection as well. The QDs are operable for receiving ultraviolet (UV), infrared (IR), visible, x-ray, and/or gamma ray radiation emanating from lightning or the like and generating visible radiation that may be detected and utilized to generate topological event information, such that property, human life, and the like may be safeguarded.

Bahritdinov, Farhod↗

Resolution of 100 photons and quantum generation of unbiased random numbers

Macroscopic quantum phenomena, such as observed in superfluids and superconductors, have led to promising technological advancements and some of the most important tests of fundamental physics. At present, quantum detection of light is mostly relegated to the microscale, where avalanche photodiodes are very sensitive to distinguishing single-photon events from vacuum but cannot differentiate between larger photon-number events. Beyond this, the ability to perform measurements to resolve photon numbers is highly desirable for a variety of quantum information applications including computation, sensing, and cryptography. True photon-number resolving detectors do exist, but they are currently limited to the ability to resolve on the order of 10 photons, which is too small for certain proposals. In this work, we extend photon measurement into the mesoscopic regime by implementing a detection scheme based on multiplexing highly quantum-efficient transition-edge sensors to accurately resolve photon numbers between zero and 100. Further, we then demonstrate the use of our system by implementing a quantum random number generator with no inherent bias. This method is based on sampling a coherent state in the photon-number basis and is robust against environmental noise, phase and amplitude fluctuations in the laser, loss and detector inefficiency as well as eavesdropping. Beyond true random number generation, our detection scheme serves as a means to implement quantum measurement and engineering techniques valuable for photonic quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum signatures in nonlinear gravitational waves

The effective quantum field theory description of gravity, despite its non-renormalizability, allows for predictions beyond classical general relativity. As we enter the age of gravitational wave astronomy, an important and timely question is whether measurable quantum predictions that depart from classical gravity, analogous to quantum optics effects which cannot be explained by classical electrodynamics, can be found. In this work, we investigate quantum signatures in gravitational waves using tools from quantum optics. Squeezed-coherent gravitational waves, which can exhibit sub-Poissonian graviton statistics, can enhance or suppress the signal measured by an interferometer, a characteristic effect of quantum squeezing. Moreover, we show that Gaussian gravitational wave quantum states can be reconstructed from measurements over an ensemble of optical fields interacting with a single copy of the gravitational wave, thus opening the possibility of detecting quantum features of gravity beyond classical general relativity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superlattice Long-Wavelength Infrared Sensors

Superlattice of LaN and Si detects at wavelengths up to 12 micrometers. If LaN grown epitaxially on silicon, sensitivity of silicon-based photodetectors extended farther into infrared wavelength region with high quantum detection efficiency by use of LaN/Si superlattices. In principle, by appropriate choice of thicknesses of layers, effective band-gap energy of superlattice structure set to any desired value between band gaps of two materials.

Fathauer, Robert W.↗

Quantitative analysis of autoradiographic image intensification using Thiourea-S35

Photographic images enhanced by the method of Thiourea-S35 autoradiography are evaluated in terms of signal-to-noise ratio, detective quantum efficiency (DQE), and Wiener spectrum analysis using digitized images. It is determined that the original signal-to-noise ratio is not degraded by the intensification process which allows an increase in the practical working DQE as a function of density. These results apply at all spatial frequencies that were tested. The advantage given by autoradiography is the ability to produce usable images from emulsions originally exposed to the low densities corresponding to maximum DQE and movement of faint image densities above the level of the threshold for detection.

Askins, B. S.↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Optical Bound States in the Continuum Enabled by Magnetic Resonances Coupled to a Mirror

Dielectric metasurfaces made of high refractive index and low optical loss materials have emerged as promising platforms to achieve high-quality factor modes enabling strong light–matter interaction. Bound states in the continuum have shown potential to demonstrate narrow spectral resonances but often require asymmetric geometry and typically feature strong polarization dependence, complicating fabrication and limiting practical applications. Here, we introduce a novel approach for designing high-quality bound states in the continuum using magnetic dipole resonances coupled to a mirror. The resulting metasurface has simple geometric parameters requiring no broken symmetry. To demonstrate the unique features of our photonic platform we show a record-breaking third harmonic generation efficiency from the metasurface benefiting from the strongly enhanced electric field at high-quality resonances. Our approach mitigates the shortcomings of previous platforms with simple geometry enabling facile and large-area fabrication of metasurfaces paving the way for applications in optical sensing, detection, quantum photonics, and nonlinear devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Supernova Axions Convert to Gamma Rays in Magnetic Fields of Progenitor Stars

It has long been established that axions could have been produced within the nascent proto-neutron star formed following the type II supernova SN1987A, escaped the star due to their weak interactions, and then converted to gamma rays in the Galactic magnetic fields; the nonobservation of a gamma-ray flash coincident with the neutrino burst leads to strong constraints on the axion-photon coupling for axion masses m a ≲10 –10 eV. In this Letter, we use SN1987A to constrain higher mass axions, all the way to m a ~10 –3 eV, by accounting for axion production from the Primakoff process, nucleon bremsstrahlung, and pion conversion along with axion-photon conversion on the still-intact magnetic fields of the progenitor star. Moreover, we show that gamma-ray observations of the next Galactic supernova, leveraging the magnetic fields of the progenitor star, could detect quantum chromodynamics axions for masses above roughly 50 μ⁢eV, depending on the supernova. We propose a new full-sky gamma-ray satellite constellation that we call the GALactic AXion Instrument for Supernova (GALAXIS) to search for such future signals along with related signals from extragalactic neutron star mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Quantum Machine Learning to High Energy Physics Analysis at LHC using IBM Quantum Computer Simulators and IBM Quantum Computer Hardware

Our group pioneers the use of Quantum Machine Learning (QML) on High Energy Physics analysis at LHC. We have successfully employed several QML classification algorithms in the ttH (Higgs production in association with a top quark pair) and Higgs to two muons (Higgs coupling to second generation fermions), two recent LHC flagship physics analysis, on gate-model quantum computer simulators and hardware. The simulation studies have been performed with the IBM Quantum Framework, Google Tensorflow Quantum Framework, and Amazon Braket Framework, and we have achieved good classification performance that is similar to the performances of the classical machine learning methods currently used in LHC physics analyses, classical SVM, classical BDT, and classical deep neural network for example. We have also performed our studies using IBM superconducting quantum computer hardware and the performance is promising and is approaching the performance from IBM quantum simulators. Moreover, we extend our studies to other QML areas such as quantum anomaly detection and quantum generative adversarial, and some preliminary results have been obtained. Also, we have overcome the challenges of intensive computing resources in the cases of large qubits (25 qubits or more) and large numbers of events using NVIDIA cuQuantum with NERSC Perlmutter HPC. Our studies give an example that Quantum Machine Learning performs as well as its classical counterpart for realistic High Energy Physics analysis datasets. Furthermore, our result on noisy quantum hardware provides important validation for the result on noiseless quantum simulators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

Television photometry - The Mariner 9 experience

Television photometry is compared to conventional techniques. Reduced data from Mariner 9 cameras should, under optimum conditions, have been accurate to a few percent. However, a combination of unstable camera properties and various unfortunate circumstances produced serious nonlinearities and other systematic errors. The means of estimating these errors are described in detail; they lean heavily on the fortuitous presence of a few specks of dust on the faceplate of one vidicon. Crude corrections will probably improve the photometric quality for the two most-used filter positions of the A camera. It would be very difficult to improve the photometry further. In view of their low photometric accuracy and detective quantum efficiency vidicons do not seem likely to replace conventional photography, except for special applications.

Young, A. T.↗

Evaluation of a large format image tube camera for the shuttle sortie mission

A large format image tube camera of a type under consideration for use on the Space Shuttle Sortie Missions is evaluated. The evaluation covers the following subjects: (1) resolving power of the system (2) geometrical characteristics of the system (distortion etc.) (3) shear characteristics of the fiber optic coupling (4) background effects in the tube (5) uniformity of response of the tube (as a function of wavelength) (6) detective quantum efficiency of the system (7) astronomical applications of the system. It must be noted that many of these characteristics are quantitatively unique to the particular tube under discussion and serve primarily to suggest what is possible with this type of tube.

Tifft, W. C.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗

Bandwidth limitations on noiseless optical channel capacity

The channel capacity of an optical communications link utilizing direct photon detection can be substantially larger than the heterodyne detection quantum limit. In the limit of a noiseless channel the capacity per received photon can even be infinite. In most communications systems the real constraint is to deliver a certain throughput capacity measured in nats/second. The current investigation has the objective to show that due to physical limitations on the minimum time resolution which can be achieved, and for any given throughput capacity in nats/second, there exists an optimum PPM word size which maximizes the 'power efficiency capacity' expressed in nats/photon. Such an optimization will allow the system-designer to minimize the amount of power needed to achieve the desired throughput without violating his bandwidth constraint.

Butman, S. A.↗

The development and applications of charge-coupled devices for space astronomy

The developments in charge-coupled device technology over the past decade are reviewed, with emphasis on the relevance of these developments to astronomical applications. The characteristics and limitations of current commercial devices are described, and the future requirements on CCDs for space astronomy are summarized for the X-ray and near UV, optical, and infrared wavelength ranges. Emphasis is placed on the commonality of technological development which is called for, including the issues of quantum detection efficiency (photon entrance and depletion depth), charge transfer efficiency, modulation transfer function, output noise level, and array size. The system requirements on focal plane instrumentation for space astronomy are summarized, and shown to have much in common for the different wavelength bands. These requirements are discussed in terms of CCD mosaicing, cryogenic cooling, and electronics. The overlap in CCD developments in the defense, astronomical and commercial arenas is summarized.

Griffiths, R. E.↗

Performance and materials aspects of Ge:Be photoconductors

Ge:Be photoconductors were developed for low photon background applications in the 30 to 50 MM wavelength region. These detectors provide higher responsivity and lower noise equivalent power (NEP) than the Ge:Ga detectors currently operating in this wavelength range. Beryllium doped single crystals were grown by the Czochralski method from a carbon susceptor under a vacuum of approx. one million torr. An optimum detective quantum efficiency of 46% at a background flux of 1.5 x 10 to the 8th power photons/second (7 x 10 to the 13th power W) was reported. Ge:Be detector performance is strongly influenced by the absolute concentrations and the concentration ratio of residual shallow donors and shallow acceptors.

Haegel, N. M.↗