Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

New prospects for PV powered water desalination plants: case studies in Saudi Arabia: New prospects for PV powered water desalination plants

Increased water demand and increased drought episodes in the Middle East and other regions necessitate an expansion in desalination projects and create a great market opportunity for photovoltaics (PV). PV-powered desalination has previously been regarded as not being a cost-competitive solution when compared with conventionally powered desalination; however, the decline in PV costs over the last few years has changed this outlook. Here, this article presents up-to-date performance and cost analysis of reverse osmosis (RO) desalination powered with PV connected to the Saudi Arabian grid. Reference cases include relatively small (i.e., producing 6550 m 3 water per day) and large (i.e., 190 000 m 3 /day) desalination plants using seawater at a salinity of 40 000 ppm. We used data from a King Abdullah University for Science and Technology presentation and Hybrid Optimization Model for Electric Renewables 2.81 Energy Modeling Software (HOMER Energy LLC) in tandem with Desalination Economic Evaluation Program 4.0 (International Atomic Energy Agency) desalination software to analyze the techno-economic feasibility of these plants. The first phase of our work entailed a comparison between dual-axis high concentration PV (CPV) equipped with triple junction III/V solar cells and CdTe PV-powered RO systems. The estimated levelized cost of electricity from CPV is 0.16/kWh dollars, whereas that from CdTe PV is $0.10/kWh dollars and 0.09/kWh dollars for fixed-tilt and one-axis tracking systems, respectively. These costs are higher than the price of diesel-based grid electricity in the region because diesel fuel is heavily subsidized in Saudi Arabia.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation of PV Variability as a Function of PV Generation and Plant Size

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear-and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute time-scale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

irradiance↗

Novel Methods to Determine Feeder Locational PV Hosting Capacity and PV Impact Signatures

Often PV hosting capacity analysis is performed for a limited number of distribution feeders. For medium - voltage distribution feeders, previous results generally analyze less than 20 feeders, and then the results are extrapolated out to similar types of feeders. Previous hosting capacity research has often focused on determining a single value for the hosting capacity for the entire feeder, whereas this research expands previous hosting capacity work to investigate all the regions of the feeder that may allow many different hosting capacity values wit h an idea called locational hosting capacity (LHC)to determine the largest PV size that can be interconnected at different locations (buses) on the study feeders. This report discusses novel methods for analyzing PV interconnections with advanced simulati on methods. The focus is feeder and location - specific impacts of PV that determine the locational PV hosting capacity. Feeder PV impact signature are used to more precisely determine the local maximum hosting capacity of individual areas of the feeder. T he feeder signature provides improved interconnection screening with certain zones that show the risk of impact to the distribution feeder from PV interconnections.

30 DIRECT ENERGY CONVERSION↗

PV Stormwater Management Research and Testing (PV-SMaRT) (Final Technical Report)

The objective of the Photovoltaic Stormwater Management Research and Testing (PV-SMaRT) project was to develop and disseminate research-based, solar-specific resources for estimating stormwater runoff at ground-mounted PV facilities and detail stormwater management and water quality best practices. The intended use of stormwater management and water quality best practices and stormwater runoff estimation resources is to reduce balance of system soft costs associated with stormwater infrastructure requirements and improve water quality through research-tested best practices. Currently, stormwater regulations and guidelines vary by jurisdiction and can lead to regulatory uncertainty and increased compliance costs for managing stormwater runoff at solar sites. To address these concerns, the NREL team and its partners (University of Minnesota, Great Plains Institute, and Fresh Energy) established and engaged an advisory Water Quality Task Force (WQTF); conducted field research on stormwater infiltration and runoff at five ground-mounted PV sites; validated a 3-D hydrologic model to predict water runoff and generate stormwater runoff coefficients for a range of site conditions and PV designs; developed a stormwater management and water quality best practices document; and engaged with local jurisdictions and other stakeholders to disseminate best practices, stormwater runoff coefficients, and other tools. Key outputs of this project were a PV-SMaRT Runoff Calculator developed by University of Minnesota, a webinar detailing project outcomes and how to use the PV-SMaRT runoff calculator, and a document on Best Practices for regulators and developers regarding stormwater runoff at PV sites.

14 SOLAR ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Power Hardware-in-the-Loop Evaluation of PV Inverter Grid Support on Hawaiian Electric Feeders

As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods, which combine the fidelity of hardware tests with the flexibility of computer simulation. This paper summarizes a study wherein two Hawaiian Electric feeder models were converted to real-time models using an OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters based on characterization test data. The integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factor and volt-watt control settings on voltage regulation of the selected feeders using physical inverters. Selected results are presented in this paper, and complete results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance and Techno-Economic Evaluation of a Three-Phase, 50-kW SiC-Based PV Inverter

The technical capabilities and benefits of silicon carbide (SiC) compared to silicon (Si) based power electronics converters as well as the premium associated with using SiC instead of Si are well understood. This work proves that the benefits provided by SiC, such as increased efficiency, would result in a lower levelized cost of energy (LCOE) compared to both commercially available, state-of-the-art inverters and the benchmark commercial system cost calculated for the U.S. Department of Energy Solar Energy Technologies Office's SunShot program. The LCOE is calculated to be same as the commercial benchmark despite the installed system cost being 8% more than the benchmark. The LCOE calculation is based on both experiential values obtained from testing the SiC photovoltaic (PV) inverter and on the bottoms-up modeled volume cost for the same 50-kW SiC-based inverter. The PV system used for the LCOE model is also explained, and the system cost breakout is presented in this paper. Furthermore, multiple scenarios with variations in the PV system are presented to show their effect on the system LCOE.

14 SOLAR ENERGY↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months. Index Terms - photovoltaic module, floating PV systems, string, array, temperature, mismatch, utility scale.

ENGINEERING,SOLAR ENERGY↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. This paper proposes a holistic impulse-based MOV lifetime estimation framework. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Determining Series Resistance for Equivalent Circuit Models of a PV Module

Literature describes various methods for determining a series resistance for a photovoltaic device from measured IV curves. We investigate use of these techniques to estimate the series resistance parameter for a single diode equivalent circuit model. With simulated IV curves we demonstrate that the series resistance values obtained by these techniques differ systematically from the known series resistance parameter values used to generate the curves, indicating that these methods are not suitable for determining the series resistance parameter for the single diode model equation. Furthermore, we present an alternative method to determine the series resistance parameter jointly with the other parameters for the single diode model equation, and demonstrate the accuracy and reliability of this technique in the presence of measurement errors.

42 ENGINEERING↗