Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pu isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fission fragment decay simulations with the CGMF code

The CGMF code implements the Hauser-Feshbach statistical nuclear reaction model to follow the de-excitation of fission fragments by successive emissions of prompt neutrons and γ rays. The Monte Carlo technique is used to facilitate the analysis of complex distributions and correlations among the prompt fission observables. Starting from initial configurations for the fission fragments in mass, charge, kinetic energy, excitation energy, spin, and parity, Y(A,Z,KE,U,J,π), CGMF samples neutron and γ-ray probability distributions at each stage of the decay process, conserving energy, spin and parity. Nuclear structure and reaction input data from the RIPL3 library are used to describe fission fragment properties and decay probabilities. Characteristics of prompt fission neutrons, prompt fission γ rays, and independent fission yields can be studied consistently. Correlations in energy, angle and multiplicity among the emitted neutrons and γ rays can be easily analyzed as a function of the emitting fragments. Finally, in its current version, CGMF is limited to certain spontaneous fission reactions on Pu and Cf isotopes, as well as neutron-induced fission reactions up to 20 MeV on U, Np, and Pu isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Collaborative Research: Natural Organic Matter and Microbial Controls on Mobilization/Immobilization of I and Pu in Soils and Waters Affected by Radionuclide Releases in USA and Japan

In this project, the relationship between natural organic matter (NOM) and two radioactive elements that are relevant to nuclear waste disposal were studied: Plutonium (Pu) and Iodine. The human and environmental risks associated with Pu stem mainly from the very long half-lives of several of its isotopes ( 238 Pu, 88 yr; 239 Pu, 24,100 yr; 240 Pu, 6560 yr) and its radiotoxicity. Understanding Pu biogeochemical behavior in both near-field (>10-11M) and far-field scales (<10-11M) is imperative to the development of approaches for reprocessing Pu, remediation of Pu contamination and accurate assessment of risks posed by disposal practices for Pu-bearing wastes. The environmental mobility of Pu can be affected by redox potential, pH, adsorption, precipitation, complexation, colloid formation, and microbial activity, of which the first characteristic has the most profound influence. Numerous studies have shown high affinity of Pu towards NOM, as well as to mineral phases. NOM is ubiquitous in the environment, e.g., both fulvic and humic acids are able to reduce Pu(V,VI) to Pu(IV) and the redox potential of NOM is positively related to the abundance of phenolic/acidic OH groups. NOM can either facilitate or limit actinide migration, depending on specific biogeochemical conditions including pH, mineral and organic matter characteristics, etc. The other radionuclide of interest is radioiodine ( 129 I). 129I is a major by-product of nuclear fission and of serious concern to the Department of Energy (DOE) as it is among the top risk drivers at existing and potential radiowaste-contaminated sites. The risk of 129 I stems largely from its high bioconcentration factor (90% of the body’s iodine is accumulated in the thyroid), a high inventory at source terms, a very long-half life (16M years), and rapid mobility in the subsurface environment. As a consequence, 129 I has the lowest drinking water standard (1 pCi/L) among all radionuclides in the Federal Register. With a novel and sensitive gas chromatography-mass spectrometry (GC-MS) method developed in our lab, it is possible to quickly and simultaneously determine the distribution of 129 I and stable 127 I forms in environments, as low as 2 pCi/L for 129 I. This method was subsequently validated using accelerator mass spectroscopy, AMS. IO 3 - and organo-I were determined as major species in the groundwater of SRS and the Hanford Site, contrary to thermodynamic predictions that I- should be the dominant species at these sites. Mobility of 129 I was also demonstrated to depend greatly on the I species and its concentration, sediment pH, and redox state, with times to achieve equilibrium taking up to 12 weeks. Along the groundwater pathway in the F-Area of SRS, 129 I- supplied from the seepage basins was transformed to 129 IO 3 - and organo- 129 I with increasing iodine sediment sorption, causing the lower total 127 I and 129 I concentrations along the gradient transect of the waste plume. By contrast, groundwater 129 I concentrations in the wetlands (as high as 1617.3 pCi/L) were greatly elevated with respect to the source term (159.3 pCi/L). While the NOM promoted the uptake of 129 I to the wetland sediment, it also promoted the formation of soluble organic fraction. A small fraction of NOM that is bound to iodine can behave as a mobile organo-I source. Iodide was enzymatically incorporated into NOM, whereas both iodide and iodate were abiotically bound to NOM, under certain conditions. Iodate removal from the mobile aqueous phase can also occur through incorporation into carbonate (e.g., at the Hanford Site, USA). Thus immobilization and re-mobilization of iodine species were influenced by pH, Eh and the presence of NOM and metal oxides, which adds to the complexity of site remediation action. A ground-breaking result was to elucidate the products (i.e. organo-iodine moieties formed via enzymatic and non-enzymatic processes) at the molecular level by nuclear magnetic resonance (NMR) and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). We found that iodine-NOM interactions may be influenced by NOM hydrophobic aliphatic moieties. From the perspective of ESI-FTICRMS, organo-iodine formulas were ascribed to the groups of unsaturated hydrocarbons, lignins and proteins. Iodate is likely abiotically reduced to reactive iodine species by lignin- and tannin-like compounds or carboxylic-rich alicyclic molecules (CRAM). We also investigated microbial mechanisms in iodine incorporation into NOM. We established that soil bacteria isolated from F-Area of SRS did not accumulate significant amounts of I- (0.2-2%). Intracellular uptake of I- decreases with increasing pH when pH ranged from 4 to 6. In contrast, 44 out of 84 strains isolated from the F-Area of SRS can transform I- to IO 3 - and organo-iodine. In some cases, oxidation was facilitated in the presence of H 2 O 2 . Microbes can also excrete organic acids that enhance I- oxidation by lowering the ambient pH and reacting with H 2 O 2 to form peroxy carboxylic acids. At lower pH values (≤5), H 2 O 2 hydrolysis was the driving force for iodide-oxidation; whereas, at pH ≥ 6, spontaneous decomposition of peroxy carboxylic acids, originating from H 2 O 2 and organic acids were the primary cause of iodide oxidation. Lastly, it was determined that microbial processes involved in Mn (II) are capable of directly oxidizing I- via enzymatic catalysis (i.e., multicopper oxidases), or indirectly through the formation of reactive oxygen species (ROS) and/or biogenic manganese oxides. ROS-mediated oxidation of I- was found to predominate at pH >5, whereas the enzymatic and Mn oxide pathways were more active at pH < 5. Together, this project has resulted in 9 publications in high-impact journals, and the training of 1 Ph.D and 4 undergraduate students.

54 ENVIRONMENTAL SCIENCES↗

Pu-238 Production Calculator and Estimation Tool in the Advanced Test Reactor

A MS Excel tool was created to help track Pu-238 production, Np-237 feedstock use, estimate production scenarios, and coordinate planning for shipments at the Idaho National Laboratory (INL) and Advanced Test Reactor (ATR). As-run estimates were used as a basis for beginning and end of life isotopic concentrations. Multiple target types were created to demonstrate a proof of concept while actual results were not yet available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Alpha Decay Chains as Thermal Power Sources: Analysis and Applications for RTGs

Radioactive sources can provide power in remote and environmentally harsh locations such as the arctic or space. The generators powered by such sources are rugged and can withstand extreme temperatures, lack of sunlight, and require no human intervention for multiple years. Radioisotopes are used in thermoelectric generators to provide power at remote sites and deep in space. Isotopes like Pu-238, Cm-244, and Am-241 are used in these generators by NASA for power in space probes and spacecrafts. These power sources deliver a steady supply of energy over extended periods of time. Alpha particles created during decay do not travel far in a material. Their kinetic energy is transferred to heat that we can then convert into energy. Unlike beta and gamma decay, the slower-moving alpha particles stop in the material, making their energy available for use. Energy from these natural decay processes provides a reliable source of power. Spontaneous fission is rare and unreliable, and unlike induced fission processes, alpha decay occurs naturally and does not require external management or ignition. The ideal properties of an isotope for use as a power source depend upon the intended use. For use in an Arctic research base over a period of several years, but less than a decade, an isotope that provides high power output over a shorter lifespan may be the most suitable option. Whereas, for deep space missions where a consistent power source for decades or perhaps more than 100 years is needed that would require a very different isotope. One with a much longer half-life that would provide consistent power throughout that time and survive in that state in for these extended periods of time. These examples represent two extreme sides in terms of time frames. By analyzing the power produced by different radioactive decay processes over time, we can evaluate the suitability of various isotope decay chains for specific uses. Some unstable isotopes undergo a series of radioactive decays, transforming into different isotopes at each step and resulting in a stable isotope. The lists of isotopes in these decay processes are known as decay chains. Some of these chains, illustrated in the figures below, are currently being investigated for use in radioisotope thermoelectric generators (RTGs) designed for a range of operational durations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Survey of Neutron Induced Fission Experimental and Evaluated Data for 233 U, 238 Pu, 240 Pu, and 242 Pu between 100 keV and 20 MeV

We review data and evaluations for neutron-induced fission for the actinides 233 U, 238 Pu, 240 Pu and 242 Pu. These isotopes are part of common nuclear fuel cycles, especially for modern fast reactors. We focus on incident neutrons in the energy range of 100 keV to 20 MeV and compare the experimental data from the literature to the major evaluated libraries ENDF/B-VIII.1, JENDL-5, and JEFF-3.3, as well as to LLNL’s ENDL-2009.5 library. Based on the assessment of the fission cross sections, we provide recommendations on which library to use. Additional assessments covering other reaction channels will be provided separately.

07 ISOTOPE AND RADIATION SOURCES↗

Risk Analysis of Radiological Release from Pu-238 Targets During Manual Handling

Pu-238 Isotope Production Targets are routinely installed in the Advanced Test Reactor (ATR) core, transferred, and stored in the spent fuel canal. These evolutions involve manual handling and manipulation of the targets underwater using long handled tools. The ATR Safety Analysis Report (SAR) postulates a design basis accident which results in damage from manual manipulation of targets, and radiological consequences must be determined for receptors inside the reactor facility, as well as public receptors. This presentation presents the analysis used to determine the radiological consequences due to potential target damage in the ATR canal. The analysis considered radionuclide release fractions, damage ratios for handling evolutions, and entrainment of radionuclides in the canal water.

Advanced Test Reactor↗

The need for speed – Burnup determination of spent nuclear fuel

Here we present the application of a novel analytical approach for high-speed evaluation of burn-up in spent nuclear fuel. This automated online separation–direct analysis method, which simultaneously measures the isotopic compositions and concentrations of Nd, Pu, and U using isotope dilution-inductively coupled plasma mass spectrometry, enables the determination of burnup in as little as 4.5 h per sample with expanded uncertainties as low as 1.2% using as little as 1µg of fuel. We compare the determined burn-up values, sample requirements, and analysis times with an ultra-high precision, in-house developed, methodology which employs multiple analytical techniques to measure the isotopic compositions and concentrations of Nd, Pu, and U yielding burn-up values with expanded uncertainties as low as 0.49% at the 95% confidence level, the lowest reported to date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

C136A and C138A Report of Analysis

In this work the isotopic ratios and weight percentages of 238 Pu, 239 Pu, 240 Pu, 241 Pu and 242 Pu were determined using Isotope Dilution Mass Spectrometry. Two samples of C136A and C138A were sent to the Analytical Research laboratories by the National Nuclear Security Administration Nuclear Reference Material Program. The four samples were dissolved in concentrated hydrochloric acid. From the parent solutions, eight aliquots were taken, diluted, spiked with 244 Pu and submitted to separations. After the samples were separated, they were analyzed using Multicollector Inductively Coupled Plasma Mass Spectrometry. Along with the samples, two C126A Quality Control Samples were analyzed each day. Mass bias standards were also analyzed at the beginning, during and at the end of the analysis. GUM Workbench Pro software Version 2.4.1.406 was used to calculate the isotopic ratios relative to 239 Pu, and total Pu mass and the correlated expanded uncertainties.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗