Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proton detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nuclear Microprobe using Elastic Recoil Detection (ERD) for Hydrogen Profiling in High Temperature Protonic Conductors

The interaction between hydrogen and various high temperature protonic conductors (HTPC) has not been clearly understood due to poor densification and unreacted secondary phases. the melt-processing technique is used in producing fully dense simple SrCe(0.9)Y (0.10) O(3-delta) and complex Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskites that can not be achieved by solid-state sintering. the possibilities of ion beam analysis have been investigated to quantify hydrogen distribution in HTPC perovskites subjected to water heat treatment. Nuclear microprobe technique is based on the interactions of a focused ion beam of MeV light ions (H-1, H-2, He-3, He-4,.) with the sample to be analyzed to determine local elemental concentrations at the cubic micrometer scale, the elastic recoil detection analysis technique (ERDA) has been carried out using He-4(+) microbeams and detecting the resulting recoil protons. Mappings of longitudinal sections of water treated SrCeO3 and Sr(Ca(1/3)Nb(2/3))O3 perovskites have been achieved, the water treatment strongly alters the surface of simple SrCe(0.9)Y(0.10)O(3-delta) perovskite. From Rutherford Back Scattering measurements (RBS), both Ce depletion and surface re-deposition is evidenced. the ERDA investigations on water treated Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskite did not exhibit any spatial difference for the hydrogen incorporation from the surface to the centre. the amount of hydrogen incorporation for Sr3Ca(1+x)Nb(2+x)O(9-delta) was low and required further development of two less conventional techniques, ERDA in forward geometry and forward elastic diffusion H-1(p,p) H-1 with coincidence detection.

Berger, Pascal↗

Modeling the Transport Processes of a Pair of Solar Energetic Particle Events Observed by Parker Solar Probe near Perihelion

We present model calculations of the transport processes of solar energetic particles in the corona and interplanetary medium for two events detected by Parker Solar Probe near its second perihelion on 2019 April 2 and April 4. In the 2019 April 2 event, the <100 keV proton differential intensity measured by the ISOIS EPI-Lo instrument increased by more than a factor of 10 above the pre-event intensity, whereas the ~1 MeV proton differential intensity detected by the EPI-Hi instrument did not show any intensity enhancement. In the 2019 April 4 event, the ~1 MeV proton intensity showed an increase of more than a factor of 100 above the pre-event intensity, but the <100 keV proton intensity enhancement was rather low and gradual. The observational fact that only the 2019 April 4 event displayed a high-energy intensity enhancement indicates that the associated acceleration process in the second event was more energetic than the first event. However, the gradual and low enhancement of the low-energy proton intensity in the second event is at odds with the scenario. In this paper, we investigate the injection and transport processes of protons in the corona and interplanetary magnetic fields with numerical model simulations. Our model calculations suggest that the gradual and low rise of the low-energy protons in the April 4 event was probably due to the different diffusion conditions in these two events and the fact that the spacecraft was moving away from the source region during these two events.

Solar energetic particles↗

Solar flare nuclear gamma-rays and interplanetary proton events

Gamma-ray line (GRL) and solar energetic proton (SEP) events observed from February 1980 through January 1985 are compared in order to substantiate and better characterize the lack of correlation between GRL fluences and SEP event peak fluxes. The scatter plot of SEP event peak flux vs. GRL fluence is presented, and the ratio of 'solar' to 'interplanetary', about 10 MeV protons, is presented. It is shown that, while even large SEP events can originate in flares lacking detectable GRL emission, the converse case of flares with a significant GRL line fluence by lacking protons in space is rare. The ratio R of the number of about 10 MeV protons that produce GRL emission at the flare site to the number of about 10 MeV protons detected in space can vary from event to event by four orders of magnitude. There is a clear tendency for impulsive flares to have larger values of R than long-duration flares, where the flare time scale is given by the e-folding decay time of the associated soft X-ray emission.

Cliver, E. W.↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

A 200-MeV pi(+) induced nucleon removal from 24Mg

Nuclear gamma rays in coincidence with outgoing pions and/or protons following single nucleon removal from Mg24 by 200 MeV pi(+) were detected with Ge(Li) detectors. Differential cross sections are reported for gamma rays from the first excited mirror states of Na23 to Mg23 in coincidence with positive pions and/or protons detected in particle telescopes at 30, 60, 90, 120 and 150 deg; angle integrated absolute cross sections and cross section ratios sigma (Mg23/sigma (Na23) are calculated. These results are compared with the predictions of the one step quasifree (OSQF), the intranuclear cascade (INC), and the nucleon charge exchange (NCX) reaction models. The OSQF and the INC calculations generally agree with the experimental results, while the NCX calculations are in disagreement.

Joyce, D.↗

The 200 MeV Pi+ induced single-nucleon removal from 24Mg

Nuclear gamma-rays in coincidence with outgoing pions or protons following single nucleon removal from Mg-24 by 200 MeV pions (+) were detected with Ge(Li) detectors. Differential cross sections are reported for gamma-rays from the first excited mirror states of Na-23 and Mg-23 in coincidence with positive pions or protons detected in particle telescopes at 30, 60, 90, 120, and 150 deg; angle-integrated absolute cross sections and cross section ratios are calculated. These results are compared with the predictions of a Pauli-blocked plane-wave impulse approximation (PWIA) and the intranuclear cascade (INC) and nucleon charge exchange (NCX) reaction models. The PWIA and the INC calculations generally agree with the angular dependence of the experimental results but not the absolute magnitude. The NCX calculation does not reproduce the observed cross section charge ratios.

Joyce, Donald↗

Heavy ion measurement on LDEF

A stack of CR-39 and Kodak CN track detectors was exposed on the NASA satellite LDEF and recovered after almost six years in space. The quick look analysis yielded heavy ion tracks on a background of low energy secondaries from proton interaction. The detected heavy ions show a steep energy spectrum which indicates a radiation belt origin.

Beaujean, R.↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density--weighted, and T2-weighted synthetic brain MR imaging

OBJECTIVE: The objective of our study was to determine the effects of MR sequence (fluid-attenuated inversion-recovery [FLAIR], proton density--weighted, and T2-weighted) and of lesion location on sensitivity and specificity of lesion detection. MATERIALS AND METHODS: We generated FLAIR, proton density-weighted, and T2-weighted brain images with 3-mm lesions using published parameters for acute multiple sclerosis plaques. Each image contained from zero to five lesions that were distributed among cortical-subcortical, periventricular, and deep white matter regions; on either side; and anterior or posterior in position. We presented images of 540 lesions, distributed among 2592 image regions, to six neuroradiologists. We constructed a contingency table for image regions with lesions and another for image regions without lesions (normal). Each table included the following: the reviewer's number (1--6); the MR sequence; the side, position, and region of the lesion; and the reviewer's response (lesion present or absent [normal]). We performed chi-square and log-linear analyses. RESULTS: The FLAIR sequence yielded the highest true-positive rates (p < 0.001) and the highest true-negative rates (p < 0.001). Regions also differed in reviewers' true-positive rates (p < 0.001) and true-negative rates (p = 0.002). The true-positive rate model generated by log-linear analysis contained an additional sequence-location interaction. The true-negative rate model generated by log-linear analysis confirmed these associations, but no higher order interactions were added. CONCLUSION: We developed software with which we can generate brain images of a wide range of pulse sequences and that allows us to specify the location, size, shape, and intrinsic characteristics of simulated lesions. We found that the use of FLAIR sequences increases detection accuracy for cortical-subcortical and periventricular lesions over that associated with proton density- and T2-weighted sequences.

NASA Discipline Neuroscience↗

Fission foil detector calibrations with high energy protons

Fission foil detectors (FFD's) are passive devices composed of heavy metal foils in contact with muscovite mica films. The heavy metal nuclei have significant cross sections for fission when irradiated with neutrons and protons. Each isotope is characterized by threshold energies for the fission reactions and particular energy-dependent cross sections. In the FFD's, fission fragments produced by the reactions are emitted from the foils and create latent particle tracks in the adjacent mica films. When the films are processed surface tracks are formed which can be optically counted. The track densities are indications of the fluences and spectra of neutrons and/or protons. In the past, detection efficiencies have been calculated using the low energy neutron calibrated dosimeters and published fission cross sections for neutrons and protons. The problem is that the addition of a large kinetic energy to the (n,nucleus) or (p,nucleus) reaction could increase the energies and ranges of emitted fission fragments and increase the detector sensitivity as compared with lower energy neutron calibrations. High energy calibrations are the only method of resolving the uncertainties in detector efficiencies. At high energies, either proton or neutron calibrations are sufficient since the cross section data show that the proton and neutron fission cross sections are approximately equal. High energy proton beams have been utilized (1.8 and 4.9 GeV, 80 and 140 MeV) for measuring the tracks of fission fragments emitted backward and forward.

Benton, E. V.↗

Multispacecraft observations of the east-west asymmetry of solar energetic storm particle events

Energetic proton observations have been obtained by instruments aboard the IMP-7 and -8 spacecraft and Voyager-1 and -2 deep space probes, in order to study the generation of solar flare Energetic Storm Particle Events (ESP) events at widely separated locations on the same shock front which are presumably characterized, on average, by different IMF shock front configurations for solar flare sites. Energetic proton observations indicate that substantial differences in the ESP proton intensity enhancements are detected at these energies for locations on the shock front with wide heliolongitude separations. The present results indicate that acceleration of ESP protons to more than 500 keV takes place at the quasi-perpendicular shock front domain, consistent with the 'shock drift' acceleration mechanism.

Sarris, E. T.↗

Cross sections relevant to gamma ray astronomy

Gamma-ray production cross sections were measured for protons and alpha particles incident on targets consisting of nuclei of high cosmic abundance: C-12, N-14, O-16, Ne-20, Mg-24, Si-28 and Fe-56. Solid or gaseous targets were bombarded by monoenergetic beams of protons and alpha particles, and gamma rays were detected by two Ge(Li) detectors. The proton energy for each target was varied from threshold to about 24 MeV (lab); for alphas the range was from threshold to about 27 MeV. For most transitions, it was possible to measure the total cross section by placing the detectors at 30.5 deg and 109.9 deg where the fourth-order Legendre polynomial is zero. For the case of the 16O (E sub gamma = 6.13 MeV, multipolarity E3) cross sections, yields were measured at four angles. Absolute cross sections were obtained by integrating the beam current and by measuring target thicknesses and detector efficiencies. The Ge(Li) detector resolution was a few keV (although the peak widths were greater, due to Doppler broadening).

Dyer, P.↗

MARIE Dose and Flux Measurements in Mars Orbit

We present results from the Martian Radiation Environment Experiment (MARIE), aboard the 2001 Mars Odyssey spacecraft in orbit around Mars. MARIE operated successfully from March 2002 through October 2003. At the time of this writing, the instrument is off due to a loss of communications during an extremely intense Solar Particle Event. Efforts to revive MARIE are planned for Spring 2004, when Odyssey's role as a communications relay for the MER rovers is completed. During the period of successful operation, MARIE returned the first detailed energetic charged particle data from Mars. Due to limitations of the instrument, normalizing MARIE data to flux or dose is not straightforward - several large corrections are needed. Thus normalized results (like dose or flux) have large uncertainties and/or significant model-dependence. The problems in normalization are mainly due to inefficiency in detecting high-energy protons (signal-to-noise problems force the trigger threshold to be higher than optimal), to the excessively high gains employed in the signal processing electronics (many ions deposit energy sufficient to saturate the electronics, and dE/dx information is lost), and to artifacts associated with the two trigger detectors (incomplete registration of dE/dx). Despite these problems, MARIE is efficient for detecting helium ions with kinetic energies above about 30 MeV/nucleon, and for detecting high-energy ions (energies above about 400 MeV/nucleon) with charges from 5 to 10. Fluxes of these heavier ions can be compared to fluxes obtained from the ACE/CRIS instrument, providing at least one area of direct comparison between data obtained at Earth and at Mars; this analysis will be presented as a work in progress. We will also present dose-rate data, with a detailed explanation of the many sources of uncertainty in normalization. The results for both flux and dose will be compared to predictions of the HZETRN model of the GCR.

Zeitlin, C.↗

Cubic Calorimeter for High-Energy Electrons in Ultra-Long Ballooning

The concept and optimization study of a balloon-borne instrument to study high-energy (from 100 GeV to 5 TeV) cosmic ray electrons will be presented. This energy range of electrons is very interesting for the study of cosmic ray propagation and the search for the nearby sources of high-energy electrons. The instrument is based on a cubic design that allows the detection from all sides. Proton rejection is provided by stringent track analysis, which allows defining when an electron shower is exhausted while the hadron shower continues development. The collecting power of a nominal balloon-borne instrument using this concept will be over 2 square meters sr. This will provide approximately 3,000 electron events above 500 GeV for 3-month long ULDB flight. This instrument will also be capable of detecting sharp features in the high energy gamma-ray spectrum such as gamma-ray lines originating from the dark matter annihilation.

Moiseev, Alexander A.↗