Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Novel Multiagent Resource Sharing Algorithm for Control of Advanced Energy Systems

This paper implements a novel resource sharing control strategy on a fuel cell–gas turbine hybrid power system at the National Energy Technology Laboratory’s Hybrid Performance Facility (Hyper). In a fuel cell–gas turbine hybrid power system, the simultaneous interaction of the gas turbine and the fuel cell creates a tightly coupled environment characterized by conflicting dynamics. In this paper, a model-free control approach is applied to solve the tightly coupled control problem posed by this challenging environment. Specifically, this control problem is presented as a resource sharing problem that can be solved using a resource sharing algorithm that is defined based on the distribution construction concept. This algorithm creates computational agents and solves the problem through the distribution and redistribution of shared resources defined as blocks. Furthermore, two agents were created; the first agent (agent 1) controls the gas turbine speed by adjusting the electric load, and the second agent (agent 2) controls the cathode mass flow through the fuel cell using the cold-air bypass valve. A parametric study was performed over the course of 15 experimental tests for both agents 1 and 2 through an evaluation of the responses based on setpoint changes. The algorithm was shown to have behavior comparable to a previously implemented multi-input multioutput state-space controller, which was designed through a model-based control approach. The resource sharing algorithm was able to find stable performance during run-time operations without any prior system knowledge identification on the power plant and without creating models used in traditional control strategies.

25 ENERGY STORAGE↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Robust Adaptive Control for Large-scale Inverter-based Resources with Partial and Complete Loss of Inverters

This article proposes an approach to address the current and the aggregated active power control challenge for large-scale inverter-based resources subjected to partially or completely loss of inverters and grid voltage variations. To address this problem, a distributed active power mechanism is proposed which generates desired inverters current. Then an adaptive mechanism distributes the voltage control input automatically between inverters in response to the partial or complete loss of inverters. An L2-gain-based controller is designed for each inverter to track the desired current and rejects the grid voltage disturbance. Here, simulation results show a significant robust tracking for collective active power and current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Double-null power-sharing dynamics in MAST-U

Maintaining an effective double-null (DN) configuration is expected to be challenging in reactor-scale tokamak devices. As divertor power-sharing is closely linked to the magnetic topology, even minor variations can lead to fast power-sharing fluctuations which exacerbate the already daunting exhaust challenge. While the static aspects of DN power-sharing have been extensively studied across various devices, this paper presents the first detailed investigation of its dynamic behaviour. We employ dedicated H-mode experiments in MAST-U, in Super-X divertor configuration, featuring perturbation frequencies up to 200 Hz. Our results clearly show no significant dynamic damping of the power-sharing within this frequency range: the divertor responds equally to both fast and slow perturbations. Moreover, the dynamic response also aligns with quasi-static results from slow ramps, implying that static power-sharing models remain valid even for fast fluctuations. Occasionally, some deviations from the otherwise mainly linear behaviour are observed, alongside notable scatter and asymmetries between upwards and downwards trajectories. These observations are likely linked to changes in core conditions, though the underlying mechanisms remain unclear and require further study.

divertor↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Identification of high performance and component technology for space electrical power systems for use beyond the year 2000

Addressed are some of the space electrical power system technologies that should be developed for the U.S. space program to remain competitive in the 21st century. A brief historical overview of some U.S. manned/unmanned spacecraft power systems is discussed to establish the fact that electrical systems are and will continue to become more sophisticated as the power levels appoach those on the ground. Adaptive/Expert power systems that can function in an extraterrestrial environment will be required to take an appropriate action during electrical faults so that the impact is minimal. Manhours can be reduced significantly by relinquishing tedious routine system component maintenance to the adaptive/expert system. By cataloging component signatures over time this system can set a flag for a premature component failure and thus possibly avoid a major fault. High frequency operation is important if the electrical power system mass is to be cut significantly. High power semiconductor or vacuum switching components will be required to meet future power demands. System mass tradeoffs have been investigated in terms of operating at high temperature, efficiency, voltage regulation, and system reliability. High temperature semiconductors will be required. Silicon carbide materials will operate at a temperature around 1000 K and the diamond material up to 1300 K. The driver for elevated temperature operation is that radiator mass is reduced significantly because of inverse temperature to the fourth power.

Maisel, James E.↗

Cardiovascular Deconditioning in Humans: Alteration in Cardiovascular Regulation and Function During Simulated Microgravity

Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In this project we apply a powerful, new method - cardiovascular system identification (CSI) - for the study of the effects of space flight on the cardiovascular system so that effective countermeasures can be developed. CSI involves the mathematical analysis of second-to-second fluctuations in non-invasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV - respiratory activity) in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of all the physiologic mechanisms coupling these signals, CSI provides a model of the closed-loop cardiovascular regulatory state in an individual subject. The model includes quantitative descriptions of the heart rate baroreflex, autonomic function, as well as other important physiologic mechanisms. We are in the process of incorporating beat-to-beat fluctuations of stroke volume into the CSI technique in order to quantify additional physiologic mechanisms such as those involved in control of peripheral vascular resistance and alterations in cardiac contractility. We apply CSI in conjunction with the two general protocols of the Human Studies Core project. The first protocol involves ground-based, human head down tilt bed rest to simulate microgravity and acute stressors - upright tilt, standing and bicycle exercise - to provide orthostatic and exercise challenges. The second protocol is intended to be the same as the first but with the addition of sleep deprivation to determine whether this contributes to cardiovascular alterations. In these studies, we focus on the basic physiologic mechanisms responsible for the alterations in cardiovascular regulation and function during the simulated microgravity in order to formulate hypotheses regarding what countermeasures are likely to be most effective. Compared to our original proposal, the protocol we are using has been slightly modified to lengthen the bed rest period to 16 days and streamline the data collection. These modifications provide us data on a longer bed rest period and have enabled us to increase our subject throughput. Based on review of our preliminary data we have decided to test a countermeasure which is applied the very end of the bed rest period. We will use the same bed rest protocol to test this countermeasure. We anticipate completing the baseline data collection in our first protocol plus testing of the countermeasure in an additional eight subjects, at which time we plan to initiate the second protocol which includes sleep deprivation. In future studies, we plan to apply CSI to test other potential countermeasures in conjunction with the same bed rest, sleep deprivation and acute stressor models. We also anticipate applying CSI for studying astronauts before and after space flight and ultimately, during space flight. The application of CSI is providing information relevant to the development and evaluation of effective countermeasures allowing humans to adapt appropriately upon re-exposure to a gravity field, and to live and work for longer periods of time in microgravity.

Cohen, Richard↗

Instrumentation for Non-Invasive Assessment of Cardiovascular Regulation

It is critically important to be able to assess alterations in cardiovascular regulation during and after space flight. We propose to develop an instrument for the non-invasive assessment of such alterations that can be used on the ground and potentially during space flight. This instrumentation would be used by the Cardiovascular Alterations Team at multiple sites for the study of the effects of space flight on the cardiovascular system and the evaluation of countermeasures. In particular, the Cardiovascular Alterations Team will use this instrumentation in conjunction with ground-based human bed-rest studies and during application of acute stresses e.g., tilt, lower body negative pressure, and exercise. In future studies, the Cardiovascular Alterations Team anticipates using this instrumentation to study astronauts before and after space flight and ultimately, during space flight. The instrumentation may also be used by the Bone Demineralization/Calcium Metabolism Team, the Neurovestibular Team and the Human Performance Factors, Sleep and Chronobiology Team to measure changes in autonomic nervous function. The instrumentation will be based on a powerful new technology - cardiovascular system identification (CSI) - which has been developed in our laboratory. CSI provides a non-invasive approach for the study of alterations in cardiovascular regulation. This approach involves the analysis of second-to-second fluctuations in physiologic signals such as heart rate and non-invasively measured arterial blood pressure in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of multiple physiologic mechanisms, CSI provides a closed-loop model of the cardiovascular regulatory state in an individual subject.

Cohen, Richard J.↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Granger Causality for prediction in Dynamic Mode Decomposition: Application to power systems

Here, the dynamic mode decomposition (DMD) technique extracts the dominant modes characterizing the innate dynamical behavior of the system within the measurement data. For appropriate identification of dominant modes from the measurement data, the DMD algorithm necessitates ensuring the quality of the input measurement data sequences. On that account, for validating the usability of the dataset for the DMD algorithm, the paper proposed two conditions: Persistence of excitation (PE) and the Granger Causality Test (GCT). The virtual data sequences are designed with the hankel matrix representation such that the dimensions of the subspace spanning the essential system modes are increased with the addition of new state variables. The PE condition provides the lower bound for the trajectory length, and the GCT provides the order of the model. Satisfying the PE condition enables estimating an approximate linear model, but the predictability with the identified model is only assured with the temporal causation among data searched with GCT. The proposed methodology is validated with the application for coherency identification (CI) in a multi-machine power system (MMPS), an essential phenomenon in transient stability analysis. The significance of PE condition and GCT is demonstrated through various case studies implemented on 22 bus six generator system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA image-based geological expert system development project for hyperspectral image analysis

The NASA image-based geological expert system was applied to analyze remotely sensed hyperspectral image data. The major objective is for geologists to identify the earth surface mineral properties directly from the airborne and spaceborne imaging spectrometer data. With certain constraints, it is shown that the system can identify correctly different classes of mineral. It has the built-in learning paradigm to enhance the confidence factor of mineral identification. A very powerful natural language system was incorporated as the user-friendly front end, and the concurrent processing efficiency of the frame-based knowledge representation in the hypercube microsupercomputer simulation was tested.

Chiou, W. C., Sr.↗

Advanced Semi-Supervised Learning with Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Semi-Supervised Learning With Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Frequency Dynamics Modeling, State Estimation, and Control using Neural Ordinary Differential Equations (NODEs) and Soft Actor-Critic (SAC) Machine Learning Approaches

With the global energy transition of the electric power system, grid control, supervision, and protection is becoming more challenging. With the increasing integration of renewable energy sources (RES), the system dynamics are changing, causing traditional power system dynamic modeling with swing equation-based modeling approaches to fail. Additionally, the converter-dominated power grid is decreasing the system inertia, making the power system more fragile to the frequency swings. This paper first investigates and compares the application of a model-based Kalman filter state estimation approach with (i) a model-free machine learning approach --- neural ordinary differential equations (NODEs) --- and (ii) a data-driven system identification (SysId) approach to model and infer critical state values of the power system frequency dynamics. Then a model predictive control (MPC) framework is compared to a model-free Soft Actor-Critic (SAC) reinforcement learning (RL) control algorithm in providing efficient fast frequency response (FFR) to the power system frequency dynamics. The approaches are compared in terms of their performance goals as well as their per-timestep computational efficiency. Furthermore, the comparative study for state estimation shows that for the model-free requirement, both NODEs and SysId can provide accurate state estimates; however, with increasing model complexity, NODEs can be a better choice for model identification. Similarly, the results from the FFR comparative study show that the SAC RL-based FFR, once trained, outperforms MPC with better control signals and faster computation time, making the SAC RL-based FFR better option for providing FFR to the power system.

97 MATHEMATICS AND COMPUTING↗

Adaptive Online Model Update Algorithm for Predictive Control in Networked Systems

In this article, we introduce an adaptive on-line model update algorithm designed for predictive control applications in networked systems, particularly focusing on power distribution systems. Unlike traditional methods that depend on historical data for offline model identification, our approach utilizes real-time data for continuous model updates. This method integrates seamlessly with existing online control and optimization algorithms and provides timely updates in response to real-time changes. This methodology offers significant advantages, including a reduction in the communication network bandwidth requirements by minimizing the data exchanged at each iteration and enabling the model to adapt after disturbances. Furthermore, our algorithm is tailored for non-linear convex models, enhancing its applicability to practical scenarios. The efficacy of the proposed method is validated through a numerical study, demonstrating improved control performance using a synthetic IEEE test case.

data-driven model predictive control↗