Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Guide to Case Studies of Grid Enhancing Technologies

This document has been developed as a resource for the electric power industry to rapidly understand the scale and history with which certain new technologies have been installed on or otherwise simulated to impact the transmission system. This document is attempting to address the findings of the 2022 U.S. Department of Energy (DOE) Report "Grid Enhancing Technologies: A Case Study on Ratepayer Impact", which identified the need for workforce development and training materials to transition new technologies from a state of “pilots” and “case studies” to “business-as-usual.” The authors go beyond typical survey-style literature reviews in that the key details and notes about each project are identified. Still, as will become evident, there is a need for more work to be done to increase the industry’s public knowledge on important topics related to the implementation of grid enhancing technology on the transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TOGETs Overview

The Transmission Optimization with Grid Enhancing Technologies (TOGETs) project will guide future research to fill in gaps on publicly available knowledge of Grid Enhancing Technologies (GETs) and conduct a full scale, multi-faceted field exercise. Ultimately the project aims to test, verify and validate deployed GETs in a transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

Options for Meeting Data Center Demand in Virginia: Focus on GETs and Reconductoring [Slides]

Data center demand growth in Virginia will need to met with many options - GETs and/or reconductoring have the potential to be part of the solution suite in the short-term and medium-term. Almost all GETs and reconductoring technologies have more favorable economics than transmission wires investments considering relatively low levels of existing wide-scale deployment. Deployment of GETs and/or reconductoring is not a one size fits all - requires detailed analysis. The complementary nature of GETs and/or reconductoring impacts have the potential to be synergistic (more congestion relief, more transfer capability, more cost savings - when implemented together).

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Colorado Residential Resiliency and Managed Charging

Validate and model impacts of electric vehicle (EV) home charging on service transformers; analyze diverse grid locations and configurations to determine 'risk factors'; finalize/deliver new design tools and typical EV load curves; improve/issue new construction standards for transformers, secondaries, and services. To ensure residential charging equity, smart charge management strategies will be studied and analyzed with the goal of creating affordable demand charges for customers.

33 ADVANCED PROPULSION SYSTEMS↗

Force Measurement Improvements to the National Transonic Facility Sidewall Model Support System

The National Transonic Facility is a transonic pressurized cryogenic facility. The development of the high Reynolds number semi-span capability has advanced over the years to include transonic active flow control and powered testing using the sidewall model support system. While this system can be used in total temperatures down to -250Â F for conventional unpowered configurations, it is limited to temperatures above -60Â F when used with powered models that require the use of the high-pressure air delivery system. Thermal instabilities and non-repeatable mechanical arrangements revealed several data quality shortfalls by the force and moment measurement system. Recent modifications to the balance cavity recirculation system have improved the temperature stability of the balance and metric model-to-balance hardware. Changes to the mechanical assembly of the high-pressure air delivery system, particularly hardware that interfaces directly with the model and balance, have improved the repeatability of the force and moment measurement system. Drag comparisons with the high-pressure air system removed will also be presented in this paper.

Goodliff, Scott L.↗

Conceptual Integration Studies of Localized Active Flow Control on the Wing of a Commercial Aircraft

A study of conceptual integration and performance of localized active flow control technology onto wings of short-to-medium-range project passenger airplanes is summarized. Using predicted aerodynamic performance improvement opportunities on a computational fluid dynamics reference aircraft, this paper presents the estimated performance opportunities for conceptual implementation of studied wing localized active flow control technology for low-speed (takeoff and landing) application on a Project Research Aircraft configuration. Using conceptual active flow control systems and structural integration weight penalties for studied concepts, potential relevant net performance benefits can be obtained with reliable active flow control in takeoff and landing. The conceptual integration study identifies potential localized wing active flow control application opportunities for high-lift conditions using energy sources available on modern aircraft. Material benefits are estimated for takeoff and landing configurations for selected localized wing active flow control applications. The study concluded that substantial low-speed Maximum Lift and Lift/Drag related performance improvements may be possible with localized wing high-lift active flow control systems powered by auxiliary power unit, engine bleed, or electrical compressors - with due consideration of integration and weight impacts as well as availability requirements of such systems.

drag reduction↗

High Efficiency 2-Bladed Utility Wind Turbine Enhanced by CoFlow Jet Active Flow Control

The aerodynamic performance and power output of a high efficiency Co-Flow Jet (CFJ) 2-bladed Wind Turbine is studied in this paper. CFJ is a Zero-Net-Mass-Flux (ZNMF) active flow control method that dramatically increases airfoil lift coefficient and suppresses flow separation at a low energy expenditure. The 3D Reynolds Averaged Navier-Stokes (RANS) equations with one-equation Spalart-Allmaras (SA) turbulence model are solved to simulate the 3D flows of the wind turbines. The CFJ-Wind Turbine in this paper is modified from the NREL 3-bladed 3.4 MW reference wind turbine with the same RPM, blade length, distribution of chord, twist, and bending. The CFJ 2-bladed wind turbine utilizes the CFJ-NACA 64 series airfoils at most of the blade span from 31.88\% to the tip. The CFJ injection and suction slots are implemented along the full blade span to enhance the effectiveness and power output. The study shows that the 2-bladed CFJ turbine significantly increases power output compared with the 3-bladed baseline turbine at all wind speeds by 15.8\% at the wind speed of 9.8 m/s and by 25.9\% at 4 m/s respectively. The efficiency enhancement is substantially more at the low wind speed than at high wind speed. This would be very beneficial to increase the annual power output or capacity factor as wind turbines work at the speeds lower than the rated speed for most of the time. The results show that the flow field around the blade surface presents a significant enhanced suction peak near the blade leading edge, which results in a very high tangential force and thus increased wind turbine net power coefficient. Consistent with the previous study for the small NREL Phase VI research wind turbine, this paper demonstrates that CFJ 2-bladed wind turbine is an effective technology to extract more power from the wind at all speeds. This study is just an initial effort to demonstrate the advantage of the CFJ blade with no design optimization. It is believed that there is more potential to further enhance the efficiency improvement.

active flow control↗

Feasibility of Self Powered Actuation for Flow, Separation and Vibration Control

A gas turbine engine is anywhere from 40-50% efficient. A large amount of energy is wasted as heat. Some of this heat is recoverable through the use of energy harvesting and can be used for powering on-board systems or for storing energy in batteries to replace auxiliary power units (APUs). As hybrid electric aircraft become more common, the use of energy harvesting will see increasingly more benefit and become commonplace in gas turbine engines. For electric aircraft with motors, TEGs would be beneficial for reclaiming waste heat from electric motors. The primary focus of this work was to evaluate the feasibility of harvesting energy from the hot section of a gas turbine engine (for a single aisle Boeing 737 thrust class) using thermoelectric generators (TEGs). The resulting heat could be used to power on-board actuation mechanisms such as plasma actuators and piezoelectric actuators. The work is a result of a two year NASA Center Innovation Fund from 2009 to 2011. The trade-off between thermoelectric harvesting and blade surface temperature were studied to ensure that blade durability is not adversely impacted by embedding a low thermal conductivity TEG. Calculations show that.5-10 Watts can be harvested per blade depending on flow conditions and on the thermoelectric material chosen. BiTe and SiGe were used for this analysis and future thermoelectric generators or multiferroic alloys could considerably improve power output.

bottoming cycle↗

Bidirectional control system for energy flow in solar powered flywheel

An energy storage system for a spacecraft is provided which employs a solar powered flywheel arrangement including a motor/generator which, in different operating modes, drives the flywheel and is driven thereby. A control circuit, including a threshold comparator, senses the output of a solar energy converter, and when a threshold voltage is exceeded thereby indicating the availability of solar power for the spacecraft loads, activates a speed control loop including the motor/generator so as to accelerate the flywheel to a constant speed and thereby store mechanical energy, while also supplying energy from the solar converter to the loads. Under circumstances where solar energy is not available and thus the threshold voltage is not exceeded, the control circuit deactivates the speed control loop and activates a voltage control loop that provides for operation of the motor as a generator so that mechanical energy from the flywheel is converted into electrical energy for supply to the spacecraft loads.

Nola, Frank J.↗

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗

Feasibility of Self Powered Actuation for Flow, Separation and Vibration Control

Gas turbine engines are anywhere from 40-50% efficient with a large amount of waste heat production. The primary focus of this work was to evaluate the feasibility of harvesting energy from sections of an imaginary but representative gas turbine engine that has large thermal gradients using thermoelectric generators (TEGs) and using the harvested energy locally for flow control using either plasma actuators or piezoelectric actuators. This work is a summary of a two- year NASA Center Innovation Fund Project from 2010 to 2012. The trade-off between thermoelectric harvesting and turbine blade surface temperature was studied to ensure that blade durability is not adversely impacted by embedding a low thermal conductivity TEG. Calculations show that at least 2-3 Watts can be harvested per blade depending on flow conditions and on the thermoelectric material chosen while maintaining metal temperatures below critical limits. BiTe and SiGe were considered as TEG materials although higher ZT materials are now in development. A circuit to convert the DC power output of the TEG to AC input for plasma actuation was fabricated and tested. Several novel plasma actuator configurations were also tested.

Thermoelectric↗

Range of control of cardiovascular variables by the hypothalamus

New methodologies were utilized to study the influence of the hypothalamus on the cardiovascular system. The regulation of myocardial activity was investigated in monkeys with hypothalamic lesions that eliminate cardiovascular responses. Observations showed that a specific part of the hypothalamus regulates changes in myocardial contractility that accompanies emotion. Studies of the hypothalamus control of renal blood flow showed the powerful potential control of this organ over renal circulation.

Smith, O. A.↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Portable I/V-Curve Tester

Electronic load circuit for displaying current/voltage characteristic curves of power sources uses low-cost low-power CMOS operational amplifiers to control load current flowing through power MOSFET Q2 and main load transistor Q3. Thermal cutoff device turns off transistor Q3 in case of overload. To maximize battery life, battery is connected via "push-to-read" momentary-contact pushbutton switch.

Cole, S. W.↗