Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

Mosaic wedge-and-strip arrays for large format microchannel plate detectors

The authors present a novel method for joining wedge-and-strip patterns on single anodes in a mosaic array. With only a modest increase in complexity over three-conductor anodes currently in use, the ultimate detector position resolution can be significantly improved, and large-format microchannel plate detectors with pore-size-limited resolution are made possible. The problem of the transition from one anode to the next has been solved with a novel linear encoding scheme, which exhibits essentially distortionless behavior at boundaries parallel to the conducting elements and only slight distortion at the orthogonal boundaries. The ultimate resolution for two anode designs, one designed for large-format imaging and the other for high-resolution spectroscopy, is also predicted.

Martin, Christopher↗

Digital optical spark chambers

The authors constructed and tested a prototype digital readout system for optical spark chambers using a linear, solid-state charge-coupled-device detector array. Position resolution of 0.013 mm (sigma) over a 25-cm field of view has been demonstrated. It is concluded that this technique should permit the construction of economical, lightweight and low-power trajectory hodoscopes for use in cosmic-ray instrumentation on balloons and in spacecraft.

Evenson, Paul↗

High pressure gas scintillation drift chambers with wave-shifter fiber readout. II

Results from a prototype high-pressure xenon gas scintillation drift chamber using a novel wave-shifter fiber readout scheme are presented. The primary scintillation light yield was measured to be one photon per 76 + or - 12 eV deposited energy. Initial results on the chamber are presented for two-interaction separation (less than 4 mm in the drift direction and about 7 mm orthogonal to the drift); for position resolution (less than 400 microns rms in the plane orthogonal to the drift direction); and for energy resolution (less than 6 percent FWHM at 122 keV).

Parsons, A.↗

Hybrid gas scintillation proportional counter/phoswich detector for hard X-ray astronomy

A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.

Grindlay, Jonathan E.↗

Superconducting rebalance acceleration and rate sensor

The goal of this program is the development of a high precision multisensor based on a high T(sub c) superconducting proof mass. The design of a prototype is currently underway. Key technical issues appear resolvable. High temperature superconductors have complicated, hysteretic flux dynamics but the forces on them can be linearly controlled for small displacements. Current data suggests that the forces on the superconductors decay over a short time frame and then stabilize, though very long term data is not available. The hysteretic force characteristics are substantial for large scale excursions, but do not appear to be an issue for the very small displacements required in this device. Sufficient forces can be exerted for non-contact suspension of a centimeter sized proof mass in a vacuum sealed nitrogen jacket cryostat. High frequency capacitive sensing using stripline technology will yield adequate position resolution for 0.1 micro-g measurements at 100 Hz. Overall, a reasonable cost, but very high accuracy, system is feasible with this technology.

Torti, R.↗

Automated Track Recognition and Event Reconstruction in Nuclear Emulsion

The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.

Deines-Jones, P.↗

Recovery of motion parameters from distortions in scanned images

Scanned images, such as those produced by the scanning-laser ophthalmoscope (SLO), show distortions when there is target motion. This is because pixels corresponding to different image regions are acquired sequentially, and so, in essence, are slices of different snapshots. While these distortions create problems for image registration algorithms, they are potentially useful for recovering target motion parameters at temporal frequencies above the frame rate. Stetter, Sendtner and Timberlake measured large distortions in SLO images to recover the time course of rapid horizontal saccadic eye movements. Here, this work is extended with the goal of automatically recovering small eye movements in two dimensions. Eye position during the frame interval is modeled using a low dimensional parametric description, which in turn is used to generate predicted distortions of a reference template. The input image is then registered to the distorted template using normalized cross correlation. The motion parameters are then varied, and the correlation recomputed, to find the motion which maximizes the peak value of the correlation. The location and value of the correlation maximum are determined with sub-pixel precision using biquadratic interpolation, yielding eye position resolution better than 1 arc minute. This method of motion parameter estimation is tested using actual SLO images as well as simulated images. Motion parameter estimation might also be applied to individual video lines in order to reduce pipeline delays for a near real-time system.

Mulligan, Jeffrey B.↗

Mars Communication Protocols

Over the next decade, international plans and commitments are underway to develop an infrastructure at Mars to support future exploration of the red planet. The purpose of this infrastructure is to provide reliable global communication and navigation coverage for on-approach, landed, roving, and in-flight assets at Mars. The claim is that this infrastructure will: 1) eliminate the need of these assets to carry Direct to Earth (DTE) communications equipment, 2) significantly increase data return and connectivity, 3) enable small mission exploration of Mars without DTE equipment, 4) provide precision navigation i.e., 10 to 100m position resolution, 5) supply timing reference accurate to 10ms. This paper in particular focuses on two CCSDS recommendations for that infrastructure: CCSDS Proximity-1 Space Link Protocol and CCSDS File Delivery Protocol (CFDP). A key aspect of Mars exploration will be the ability of future missions to interoperate. These protocols establish a framework for interoperability by providing standard communication, navigation, and timing services. In addition, these services include strategies to recover gracefully from communication interruptions and interference while ensuring backward compatibility with previous missions from previous phases of exploration.

Kazz, G. J.↗

The Seyfert-Starburst Connection in X-rays: The Data - 1

We analyze X-ray spectra and images of a sample of Seyfert 2 galaxies that unambiguously contain starbursts, based on their optical and UV characteristics. Although all sample members contain active galactic nuclei (AGNs), supermassive black holes or other related processes at the galactic centers alone cannot account for the total X-ray emission in all instances. Eleven of the 12 observed galaxies are significantly resolved with the ROSAT High Resolution Imager, while six of the eight sources observed with the lower resolution Position Sensitive Proportional Counter also appear extended on larger scales. The X-ray emission is extended on physical scales of 10 kpc and greater, which we attribute to starburst-driven outflows and supernova heating of the interstellar medium. Spectrally, a physically motivated composite model of the X-ray emission that includes a heavily absorbed (N(sub H) greater than 10(exp 23)/sq cm) nuclear component (the AGN), power-law-like scattered AGN flux, and a thermal starburst describes this sample well. Half the sample exhibit iron K(alpha) lines, which are typical of AGNs.

Levenson, N. A.↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Piezoelectric Rotary Tube Motor

A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

Fisher, Charles D.↗

ISS-Lobster: A Proposed Wide-Field X-Ray Telescope on the International Space Station

The Lobster wide-field imaging telescope combines simultaneous high FOV, high sensitivity and good position resolution. These characteristics can open the field of X-Ray time domain astronomy, which will study many interesting transient sources, including tidal disruptions of stars, supernova shock breakouts, and high redshift gamma-ray bursts. Also important will be its use for the X-ray follow-up of gravitational wave detections. I will describe our present effort to propose the Lobster concept for deployment on the International Space Station through a NASA Mission of Opportunity this fall.

Camp, Jordan↗

Repurposing the James Webb Space Telescope’s center of curvature optical bench hexapod for future mirror calibration testing at NASA Marshall’s x-ray & cryogenic facility

The James Webb Space Telescope’s (JWST) center of curvature optical bench (CoCOB) hexapod was repurposed to enhance NASA Marshall Space Flight Center’s X-Ray & Cryogenic Facility (XRCF) optical metrology capabilities. This upgrade unlocked higher test article load capacity and extended the allowable ranges of motion of the CoCOB hexapod. The hexapod was also coupled to a new long-stroke, linear motion axis to form a 7 degrees of freedom system and allow for high precision testing of larger diameter test articles. A 9 degrees of freedom motion system, consisting of a three-axis linear mount in an X-Y-Z configuration and a commercially available hexapod, was also designed to allow high resolution positioning of the focal plane instrumentation over a large range of motion. A modern control architecture and graphical user interface was developed for the CoCOB hexapod and additional motion stages to permit streamlined commanding and operation. This paper discusses the justification for re-using the CoCOB hexapod by highlighting its unique precision motion control capabilities in a high vacuum and optically clean environment. The design, key component selection, and environmental compatibility for each of the additional motion stages is presented along with testing results for achieved range, repeatability, and minimum step size performance for all motion axes. Finally, a summary of the motion control system architecture and its flexibility to address tomorrow’s optical metrology needs are presented.

hexapod↗

A high resolution study in time, position, intensity, and frequency of a radio event on 14 January 1971

High resolution position and spectrum measurements were made of a complex solar radio activity on January 14, 1971, from 1120 to 1130 UT. Positions were measured with 169 MHz Nancay E-W Radioheliograph, while dynamic spectra and polarization were observed with the 60-channel radiospectrograph of Nera. The radio event consisted of two closely similar groups of type 3 bursts and type 2-like details, and a stationary type 4 continuum, including some very clear pulsating structures. The general aspect of this activity is presented.

Caroubalos, C.↗

On the accuracy of CO line positions for high resolution IR stellar spectroscopy

The paper demonstrates the high accuracy of line positions derived from improved sets of Dunham coefficients for the four more abundant isotopic species of carbon monoxide - (C-12)(O-16), (C-13)(O-16), (C-12)(O-18), and (C-12)(O-17) - which are present in the sun and in cool stellar atmospheres. These new spectroscopic constants make it possible to predict very accurate positions of CO lines at any J-values, especially at very high rotational excitation (up to J around 135). Earlier proposed identifications of CO lines at large J-values are checked, and some incorrect identifications in sunspot spectra are found. The present accurate line positions are also compared with predictions from other available sets of molecular constants. It is concluded that the present improved sets of molecular constants are the most appropriate to all problems of high-resolution stellar and solar spectroscopy at any J- and v-values, particularly for synthetic spectra of cool stars.

Sauval, A. J.↗

Ambiguity resolution for satellite Doppler positioning systems

A test for ambiguity resolution was derived which was the most powerful in the sense that it maximized the probability of a correct decision. When systematic error sources were properly included in the least squares reduction process to yield an optimal solution, the test reduced to choosing the solution which provided the smaller valuation of the least squares loss function. When systematic error sources were ignored in the least squares reduction, the most powerful test was a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudo-inverse of a reduced rank square matrix. A formula is presented for computing the power of the most powerful test. A numerical example is included in which the power of the test is computed for a situation which may occur during an actual satellite aided search and rescue mission.

Argentiero, P. D.↗