Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

Subtropical Eastern North Pacific SST bias in earth system models

Karthik Balaguru (PNNL), Luke Van Roekel (LLNL), L. Ruby Leung (PNNL) and Milena Veneziani (LLNL) Abstract: This study systematically evaluates the warm SST bias in the Subtropical Eastern North Pacific (SENP), a problem plaguing most CMIP6 models, using the Energy Exascale Earth System Model version 1 (E3SM). Compared to the model at its standard resolution (1o atmosphere, 30-60 km ocean), the SST bias improves in several regions at high resolution (0.25o atmosphere, 18-6 km ocean) except in subtropical eastern boundary regions, such as the SENP. A mixed layer heat budget analysis reveals that errors in the surface radiative fluxes and horizontal heat advection are primarily responsible for the bias. Analysis of HighResMIP models indicates that the lack of improvement in the SENP SST bias with resolution is not native to E3SM alone. A larger CMIP6 inter-model correlation of SST bias with biases in surface winds than radiation highlights the important role of large-scale circulation biases in the SENP SST bias in coupled models.

Balaguru, Karthik↗

Low-energy Electron-track Imaging for a Liquid Argon Time-projection-chamber Telescope Concept Using Probabilistic Deep Learning

The GammaTPC is an MeV-scale single-phase liquid argon time-projection-chamber gamma-ray telescope concept with a novel dual-scale pixel-based charge-readout system. It promises to enable a significant improvement in sensitivity to MeV-scale gamma rays over previous telescopes. The novel pixel-based charge readout allows for imaging of the tracks of electrons scattered by Compton interactions of incident gamma rays. The two primary contributors to the accuracy of a Compton telescope in reconstructing an incident gamma-ray’s original direction are its energy and position resolution. In this work, we focus on using deep learning to optimize the reconstruction of the initial position and direction of electrons scattered in Compton interactions, including using probabilistic models to estimate predictive uncertainty. We show that the deep-learning models are able to predict locations of Compton scatters of MeV-scale gamma rays from simulated 500 μm pixel-based data to better than 1 mm rms error and are sensitive to the initial direction of the scattered electron. We compare and contrast different deep-learning uncertainty estimation algorithms for reconstruction applications. Additionally, we show that event-by-event estimates of the uncertainty of the locations of the Compton scatters can be used to select those events that were reconstructed most accurately, leading to improvement in locating the origin of gamma-ray sources on the sky.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An imaging gas scintillation proportional counter for use in X-ray astronomy

An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.

Hailey, C. J.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

The SEASAT Synthetic Aperture Radar - Engineering performance evaluation

Results are presented for a study conducted in order to characterize the quality and consistency of the SEASAT Synthetic Aperture Radar image data set. The study evaluated a large spectrum of parameters, including the resolution, position location accuracy, and the amplitude calibration of the imagery produced from the raw data by processors at several institutions. It is demonstrated that this data set can be used to obtain resolution up to the theoretical limit of 6 m x 21 m, absolute position location to within 200 m, and relative calibration of the image data to within + or - 2 dB.

Held, D. N.↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Images of single X-ray photons from X-ray phosphor screens

Photographs show the efficiency and resolution characteristics of single X-ray photons converted to optical photons in a variety of commercial X-ray phosphor screens. The recording system uses a cooled, two-stage image intensifier system with fiber optics coupling to the phosphor screen. High efficiencies in the energy range 20-100 keV with position resolution of the order 200 microns are readily achievable, although the sensitive area is presently limited. Potential applications include X-ray astronomy, high-speed X-ray diffractometry, and extremely low dose radiography.

Fishman, G. J.↗

New Mission Concept: Investigation of the Galactic Center with the Galactic Center Explorer (GalCenEx)

The European Space Observatory INTEGRAL has been providing excellent results on X-ray and γ–ray astronomy since its launch in 2002. Among the most important results are the spectroscopy and imaging measurements of celestial γ-ray sources, including mapping the 511 keV radiation from the Galactic plane. However, the nature of the 511 keV positron annihilation line around the Galactic Center region is still a mystery. Similarly, the structure and nature of the Galactic Center supermassive black hole and its surroundings, as well as the structure of heavily populated sky regions such as Cygnus and Carina in γ-rays, remain unclear. We present a concept of a potential next-generation γ-ray telescope with the major science objectives: a) solve the mystery of the Galactic Center region 511 keV positron annihilation line by mapping the Galactic Center region with high energy (<1% FWHM) and angular (< 10 arcmin) resolution and with line sensitivity <10-5 ph cm-2 s-1; b) understand the nature of the Galactic Center supermassive black hole environment by creating a high-resolution spectral and intensity map of the surrounding region in 0.1 – 20 MeV γ rays; and c) explore Galactic chemical evolution and sites of explosive element synthesis by conducting high-sensitivity measurements of nuclear lines from Type 1a supernovae and other objects. The instrument is based on a novel high energy and position resolution CdZnTe Imager, coded aperture mask, and heavy-scintillator shield, and can be considered for a NASA Explorer mission.

Moiseev, Alexander↗

Investigation of signal characteristics and charge sharing in AC-LGADs with laser and test beam measurements

AC-LGADs, also referred to as resistive silicon detectors, are a recent development of low-gain avalanche detectors (LGADs), based on a sensor design where the multiplication layer and n + contact are continuous, and only the metal layer is patterned. In AC-LGADs, the signal is capacitively coupled from the continuous, resistive n + layer over a dielectric to the metal electrodes. Therefore, the spatial resolution is not only influenced by the electrode pitch, but also the relative size of the metal electrodes. Signal propagation between the metallized areas and charge sharing between electrodes plays a larger role in these detectors than in conventional silicon sensors read out in DC mode. AC-LGADs from two manufacturers were studied in beam tests and with infrared laser scans. The impact of n + layer resistivity and metal electrode pitch on the charge sharing and achievable position resolution is shown. For strips with 100 μm pitch, a resolution of ¡ 5 μm can be reached. Additionally, the charge sharing between neighboring strips is investigated in more detail, indicating the induction of signal charge and subsequent re-sharing over the n + layer. Furthermore, an approach to identify signal sharing over large distances is presented.

47 OTHER INSTRUMENTATION↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Design and Optimization of Multi-Pixel Transition-Edge Sensors for X-Ray Astronomy Applications

Multi-pixel transition-edge sensors (TESs), commonly referred to as 'hydras', are a type of position sensitive micro-calorimeter that enables very large format arrays to be designed without commensurate increase in the number of readout channels and associated wiring. In the hydra design, a single TES is coupled to discrete absorbers via varied thermal links. The links act as low pass thermal filters that are tuned to give a different characteristic pulse shape for x-ray photons absorbed in each of the hydra sub pixels. In this contribution we report on the experimental results from hydras consisting of up to 20 pixels per TES. We discuss the design trade-offs between energy resolution, position discrimination and number of pixels and investigate future design optimizations specifically targeted at meeting the readout technology considered for Lynx.

Smith, Stephen J.↗

ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗