Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Portal protein functions akin to a DNA-sensor that couples genome-packaging to icosahedral capsid maturation

Tailed bacteriophages and herpesviruses assemble infectious particles via an empty precursor capsid (or ‘procapsid’) built by multiple copies of coat and scaffolding protein and by one dodecameric portal protein. Genome packaging triggers rearrangement of the coat protein and release of scaffolding protein, resulting in dramatic procapsid lattice expansion. Here, we provide structural evidence that the portal protein of the bacteriophage P22 exists in two distinct dodecameric conformations: an asymmetric assembly in the procapsid (PC-portal) that is competent for high affinity binding to the large terminase packaging protein, and a symmetric ring in the mature virion (MV-portal) that has negligible affinity for the packaging motor. Modelling studies indicate the structure of PC-portal is incompatible with DNA coaxially spooled around the portal vertex, suggesting that newly packaged DNA triggers the switch from PC- to MV-conformation. Thus, we propose the signal for termination of ‘Headful Packaging’ is a DNA-dependent symmetrization of portal protein.

59 BASIC BIOLOGICAL SCIENCES↗

A two-dimensional matrix correction for off-axis portal dose prediction errors

Purpose: This study presents a follow-up to a modified calibration procedure for portal dosimetry published by Bailey et al. ['An effective correction algorithm for off-axis portal dosimetry errors,' Med. Phys. 36, 4089-4094 (2009)]. A commercial portal dose prediction system exhibits disagreement of up to 15% (calibrated units) between measured and predicted images as off-axis distance increases. The previous modified calibration procedure accounts for these off-axis effects in most regions of the detecting surface, but is limited by the simplistic assumption of radial symmetry. Methods: We find that a two-dimensional (2D) matrix correction, applied to each calibrated image, accounts for off-axis prediction errors in all regions of the detecting surface, including those still problematic after the radial correction is performed. The correction matrix is calculated by quantitative comparison of predicted and measured images that span the entire detecting surface. The correction matrix was verified for dose-linearity, and its effectiveness was verified on a number of test fields. The 2D correction was employed to retrospectively examine 22 off-axis, asymmetric electronic-compensation breast fields, five intensity-modulated brain fields (moderate-high modulation) manipulated for far off-axis delivery, and 29 intensity-modulated clinical fields of varying complexity in the central portion of the detecting surface. Results: Employing the matrix correction to the off-axis test fields and clinical fields, predicted vs measured portal dose agreement improves by up to 15%, producing up to 10% better agreement than the radial correction in some areas of the detecting surface. Gamma evaluation analyses (3 mm, 3% global, 10% dose threshold) of predicted vs measured portal dose images demonstrate pass rate improvement of up to 75% with the matrix correction, producing pass rates that are up to 30% higher than those resulting from the radial correction technique alone. As in the 1D correction case, the 2D algorithm leaves the portal dosimetry process virtually unchanged in the central portion of the detector, and thus these correction algorithms are not needed for centrally located fields of moderate size (at least, in the case of 6 MV beam energy).Conclusion: The 2D correction improves the portal dosimetry results for those fields for which the 1D correction proves insufficient, especially in the inplane, off-axis regions of the detector. This 2D correction neglects the relatively smaller discrepancies that may be caused by backscatter from nonuniform machine components downstream from the detecting layer.

60 APPLIED LIFE SCIENCES↗

SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

BSD Portals for LINUX 2.0

Portals, an experimental feature of 4.4BSD, extend the file system name space by exporting certain open () requests to a user-space daemon. A portal daemon is mounted into the file name space as if it were a standard file system. When the kernel resolves a pathname and encounters a portal mount point, the remainder of the path is passed to the portal daemon. Depending on the portal "pathname" and the daemon's configuration, some type of open (2) is performed. The resulting file descriptor is passed back to the kernel which eventually returns it to the user, to whom it appears that a "normal" open has occurred. A proxy portalfs file system is responsible for kernel interaction with the daemon. The overall effect is that the portal daemon performs an open (2) on behalf of the kernel, possibly hiding substantial complexity from the calling process. One particularly useful application is implementing a connection service that allows simple scripts to open network sockets. This paper describes the implementation of portals for LINUX 2.0.

McNab, A. David↗

Next Gen One Portal Usability Evaluation

Each exercise device on the International Space Station (ISS) has a unique, customized software system interface with unique layouts / hierarchy, and operational principles that require significant crew training. Furthermore, the software programs are not adaptable and provide no real-time feedback or motivation to enhance the exercise experience and/or prevent injuries. Additionally, the graphical user interfaces (GUI) of these systems present information through multiple layers resulting in difficulty navigating to the desired screens and functions. These limitations of current exercise device GUI's lead to increased crew time spent on initiating, loading, performing exercises, logging data and exiting the system. To address these limitations a Next Generation One Portal (NextGen One Portal) Crew Countermeasure System (CMS) was developed, which utilizes the latest industry guidelines in GUI designs to provide an intuitive ease of use approach (i.e., 80% of the functionality gained within 5-10 minutes of initial use without/limited formal training required). This is accomplished by providing a consistent interface using common software to reduce crew training, increase efficiency & user satisfaction while also reducing development & maintenance costs. Results from the usability evaluations showed the NextGen One Portal UI having greater efficiency, learnability, memorability, usability and overall user experience than the current Advanced Resistive Exercise Device (ARED) UI used by astronauts on ISS. Specifically, the design of the One-Portal UI as an app interface similar to those found on the Apple and Google's App Store, assisted many of the participants in grasping the concepts of the interface with minimum training. Although the NextGen One-Portal UI was shown to be an overall better interface, observations by the test facilitators noted specific exercise tasks appeared to have a significant impact on the NextGen One-Portal UI efficiency. Future updates to the NextGen One Portal UI will address these inefficiencies.

Cross, E. V., III↗

The SNS/HFIR Web Portal System – How Can it Help Me?

Abstract. In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 5TB of experiment and user data, approximately 660K files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Lastly, portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The SNS/HFIR Web Portal System for SANS

In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 7TB of experiment and user data, approximately 1,000,000 files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

data↗

Percutaneous Transsplenic Access to the Portal Vein for Management of Vascular Complication in Patients with Chronic Liver Disease

Purpose: To evaluate the safety and feasibility of percutaneous transsplenic access to the portal vein for management of vascular complication in patients with chronic liver diseases. Methods: Between Sept 2009 and April 2011, percutaneous transsplenic access to the portal vein was attempted in nine patients with chronic liver disease. Splenic vein puncture was performed under ultrasonographic guidance with a Chiba needle, followed by introduction of a 4 to 9F sheath. Four patients with hematemesis or hematochezia underwent variceal embolization. Another two patients underwent portosystemic shunt embolization in order to improve portal venous blood flow. Portal vein recanalization was attempted in three patients with a transplanted liver. The percutaneous transsplenic access site was closed using coils and glue. Results: Percutaneous transsplenic splenic vein catheterization was performed successfully in all patients. Gastric or jejunal varix embolization with glue and lipiodol mixture was performed successfully in four patients. In two patients with a massive portosystemic shunt, embolization of the shunting vessel with a vascular plug, microcoils, glue, and lipiodol mixture was achieved successfully. Portal vein recanalization was attempted in three patients with a transplanted liver; however, only one patient was treated successfully. Complete closure of the percutaneous transsplenic tract was achieved using coils and glue without bleeding complication in all patients. Conclusion: Percutaneous transsplenic access to the portal vein can be an alternative route for portography and further endovascular management in patients for whom conventional approaches are difficult or impossible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Disastrous Portal Vein Embolization Turned into a Successful Intervention

Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which could aid in individualizing therapy, particularly for patients at risk for liver injury after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The BioMart community portal: an innovative alternative to large, centralized data repositories

The BioMart Community Portal (www.biomart.org) is a community-driven effort to provide a unified interface to biomedical databases that are distributed worldwide. The portal provides access to numerous database projects supported by 30 scientific organizations. It includes over 800 different biological datasets spanning genomics, proteomics, model organisms, cancer data, ontology information and more. All resources available through the portal are independently administered and funded by their host organizations. The BioMart data federation technology provides a unified interface to all the available data. The latest version of the portal comes with many new databases that have been created by our ever-growing community. It also comes with better support and extensibility for data analysis and visualization tools. A new addition to our toolbox, the enrichment analysis tool is now accessible through graphical and web service interface. The BioMart community portal averages over one million requests per day. Building on this level of service and the wealth of information that has become available, the BioMart Community Portal has introduced a new, more scalable and cheaper alternative to the large data stores maintained by specialized organizations.

59 BASIC BIOLOGICAL SCIENCES↗

A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter

Purpose: The aim of this study was to develop a computerized method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Three types of graticules were included in this study: Megavoltage (MV) mechanical graticule, MV electronic portal imaging device digital graticule, and kilovoltage (kV) on-board imaging digital graticule. Methods: A metal ball bearing (BB) was imaged with MV and kV x-ray beams in a procedure similar to a Winston-Lutz test. The radiation fields, graticules, and BB were localized in eight portal images using Hough transform-based computer algorithms. The center of the BB served as a static reference point in the 3D space so that the distances between the graticule centers and the radiation field centers were calculated. The radiation isocenter was determined from the radiation field centers at different gantry angles. Results: Misalignments of MV and kV portal imaging graticules varied with the gantry or x-ray source angle as a result of mechanical imperfections of the linear accelerator and its imaging system. While the three graticules in this study were aligned to the radiation field centers and the radiation isocenter within 2.0 mm, misalignments of 1.5-2.0 mm were found at certain gantry angles. These misalignments were highly reproducible with the gantry rotation. Conclusions: A simple method was developed to quantify the alignments of portal image graticules directly against the radiation field centers or the radiation isocenter. The advantage of this method is that it does not require the BB to be placed exactly at the radiation isocenter through a precalibrated surrogating device such as room lasers or light field crosshairs. The present method is useful for radiation therapy modalities that require high-precision portal imaging such as image-guided stereotactic radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Level-set segmentation of pulmonary nodules in megavolt electronic portal images using a CT prior

Purpose: Pulmonary nodules present unique problems during radiation treatment due to nodule position uncertainty that is caused by respiration. The radiation field has to be enlarged to account for nodule motion during treatment. The purpose of this work is to provide a method of locating a pulmonary nodule in a megavolt portal image that can be used to reduce the internal target volume (ITV) during radiation therapy. A reduction in the ITV would result in a decrease in radiation toxicity to healthy tissue. Methods: Eight patients with nonsmall cell lung cancer were used in this study. CT scans that include the pulmonary nodule were captured with a GE Healthcare LightSpeed RT 16 scanner. Megavolt portal images were acquired with a Varian Trilogy unit equipped with an AS1000 electronic portal imaging device. The nodule localization method uses grayscale morphological filtering and level-set segmentation with a prior. The treatment-time portion of the algorithm is implemented on a graphical processing unit. Results: The method was retrospectively tested on eight cases that include a total of 151 megavolt portal image frames. The method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases. The treatment phase portion of the method has a subsecond execution time that makes it suitable for near-real-time nodule localization. Conclusions: A method was developed to localize a pulmonary nodule in a megavolt portal image. The method uses the characteristics of the nodule in a prior CT scan to enhance the nodule in the portal image and to identify the nodule region by level-set segmentation. In a retrospective study, the method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases studied.

60 APPLIED LIFE SCIENCES↗

SU-F-T-272: Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry

Purpose: To evaluate the effectiveness of using the Portal Dosimetry (PD) method for patient specific quality assurance of prostate VMAT plans. Methods: As per institutional protocol all VMAT plans were measured using the Varian Portal Dosimetry (PD) method. A gamma evaluation criterion of 3%-3mm with a minimum area gamma pass rate (gamma <1) of 95% is used clinically for all plans. We retrospectively evaluated the portal dosimetry results for 170 prostate patients treated with VMAT technique. Three sets of criterions were adopted for re-evaluating the measurements; 3%-3mm, 2%-2mm and 1%-1mm. For all criterions two areas, Field+1cm and MLC-CIAO were analysed.To ascertain the effectiveness of the portal dosimetry technique in determining the delivery accuracy of prostate VMAT plans, 10 patients previously measured with portal dosimetry, were randomly selected and their measurements repeated using the ArcCHECK method. The same criterion used in the analysis of PD was used for the ArcCHECK measurements. Results: All patient plans reviewed met the institutional criteria for Area Gamma pass rate. Overall, the gamma pass rate (gamma <1) decreases for 3%-3mm, 2%-2mm and 1%-1mm criterion. For each criterion the pass rate was significantly reduced when the MLC-CIAO was used instead of FIELD+1cm. There was noticeable change in sensitivity for MLC-CIAO with 2%-2mm criteria and much more significant reduction at 1%-1mm. Comparable results were obtained for the ArcCHECK measurements. Although differences were observed between the clockwise verses the counter clockwise plans in both the PD and ArcCHECK measurements, this was not deemed to be statistically significant. Conclusion: This work demonstrates that Portal Dosimetry technique can be effectively used for quality assurance of VMAT plans. Results obtained show similar sensitivity compared to ArcCheck. To reveal certain delivery inaccuracies, the use of a combination of criterions may provide an effective way in improving the overall sensitivity of PD. Funding provided in part by the Prostate Ride for Dad, Kitchener-Waterloo, Canada.

60 APPLIED LIFE SCIENCES↗

Portal Monitoring Considerations for Treaty Verification Applications

Portal monitoring is one method in a suite of options for treaty verification and can assist in verification of treaty accountable items (TAIs). Portal monitor technology spans a wide range of sensors, including radiation detectors, break-beams, or weight sensors. For radiation-detecting portal monitors, they are able to confirm absence / presence of a radiological signature and to track TAI direction of motion. Portal monitoring uses measurements from strategically placed sensors (e.g., radiation detectors) to record the entry or egress of TAIs. The implementation of portal monitoring relies on three key elements: perimeter definition, portal locations, and sensor technology, and can be implemented in either time-bound or continuous operations depending on what is permitted by the Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

JPL Genesis and Rapid Intensification Processes (GRIP) Portal

Satellite observations can play a very important role in airborne field campaigns, since they provide a comprehensive description of the environment that is essential for the experiment design, flight planning, and post-experiment scientific data analysis. In the past, it has been difficult to fully utilize data from multiple NASA satellites due to the large data volume, the complexity of accessing NASA s data in near-real-time (NRT), as well as the lack of software tools to interact with multi-sensor information. The JPL GRIP Portal is a Web portal that serves a comprehensive set of NRT observation data sets from NASA and NOAA satellites describing the atmospheric and oceanic environments related to the genesis and intensification of the tropical storms in the North Atlantic Ocean. Together with the model forecast data from four major global atmospheric models, this portal provides a useful tool for the scientists and forecasters in planning and monitoring the NASA GRIP field campaign during the 2010 Atlantic Ocean hurricane season. This portal uses the Google Earth plug-in to visualize various types of data sets, such as 2D maps, wind vectors, streamlines, 3D data sets presented at series of vertical cross-sections or pointwise vertical profiles, and hurricane best tracks and forecast tracks. Additionally, it allows users to overlap multiple data sets, change the opacity of each image layer, generate animations on the fly with selected data sets, and compare the observation data with the model forecast using two independent calendars. The portal also provides the capability to identify the geographic location of any point of interest. In addition to supporting the airborne mission planning, the NRT data and portal will serve as a very rich source of information during the post-field campaign analysis stage of the airborne experiment. By including a diverse set of satellite observations and model forecasts, it provides a good spatial and temporal context for the high-resolution, but limited in space and time, airborne observations.

Knosp, Brian W.↗

Visualization and Analysis of Data from Small-Body Missions with NASA's Solar System Treks Portals

The portals of NASA's Solar System Trek Project (SSTP) provide web-based suites of interactive visualization and analysis tools enabling mission planners, planetary scientists, students, and the general public to explore planetary surfaces as seen through the eyes of many different instruments aboard a wide range of spacecraft. The portals present a vast collection of mapped data products from past and current missions for a growing number of planetary bodies. As web-based toolsets, the portals do not require users to purchase or install any software beyond current web browsers. They feature a common user interface and are available through a single integrated website at https://trek.nasa.gov. This presentation will highlight 4 portals focusing on small bodies. We will provide an overview of established portals for (1) Ceres and (4) Vesta, and present the early capabilities for new portals being introduced for (162173) Ryugu and (101955) Bennu.

Day, Brian↗