Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Polyvinylidene fluoride”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Technological development of cylindrical and flat shaped high energy density capacitors

Cylindrical wound metallized film capacitors rated 2 micron F 500 VDC that had an energy density greater than 0.3 J/g, and flat flexible metallized film capacitors rated at 2 micron F 500 VDC that had an energy density greater than 0.1 J/g were developed. Polysulfone, polycarbonate, and polyvinylidene fluoride (PVF2) were investigated as dielectrics for the cylindrical units. PVF2 in 6.0 micron m thickness was employed in the final components of both types. Capacitance and dissipation factor measurements were made over the range 25 C to 100 C, and 10 Hz to 10 kHz. No pre-life-test burning was performed, and six of ten cylindrical units survived a 2500 hour AC plus DC lift test. Three of the four failures were infant mortality. All but two of the flat components survived 400 hours. Finished energy densities were 0.104 J/g at 500 V and 0.200 J/g at 700 V, the energy density being limited by the availability of thin PVF2 films.

Zelik, J. A.

Two-week studies of survivors from exposures to pyrolysis gases

Swiss Webster male mice which had survived near-lethal concentrations of pyrolysis gases from a variety of polymeric materials were killed two weeks after exposure, and the lungs, heart, liver, kidney, and spleen were examined. Microscopic examination revealed no significant effects on the liver, kidney, and spleen, while the effect on lungs could not be determined because of the high level of pathology in both experimental and control animals. The polymeric materials which were pyrolyzed were polyethylene, ABS, polycarbonate, polyaryl sulfone, polyether sulfone, polyphenylene sulfide, modified polyphenylene oxide, chlorinated polyvinyl chloride, polyvinylidene fluoride, and fluorene polycarbonate. It is suggested that tissue specimens should be examined 24 or 48 hr after exposure rather than 2 wks after exposure, since the 2 wk period permits healing to occur.

Bucci, T. J.

Radiation response and electrical properties of polymer energy storage capacitors: PVF2, Polysulfone, and Mylar

Efforts were made to develop a polymer film capacitor that is tolerant to radiation. The capacitors are to be utilized in a high voltage pulse discharge application. Radiation response data at high dose/dose rate levels are presented for polyvinylidene fluoride (PVF2), polysulfone, and Mylar. The results show that PVF2 is the most radiation tolerant while Mylar is the least tolerant. The data also show that the radiation response is quite dependent on operating electric stress.

Edwards, L. R.

Pyroelectric materials as electronic pulse detectors of ultraheavy nuclei

The design and testing of ultraheavy-nucleus pulse detectors based on pyroelectric materials are reported, extending the preliminary findings of Tuzzolino (1983) and Simpson and Tuzzolino (1983). Uranium-ion beams of about 240 MeV/u are detected by a 39.5-micron-thick Si detector, degraded to about 175 MeV/u by Al absorbers, and then strike 700-micron-thick polyvinylidene fluoride or 1000-micron-thick LiTaO3 pyroelectric samples. Both detector systems are connected to a coincidence circuit via charge-sensitive preamplifiers, shaping amplifiers with 30-microsec effective time constants, and electronic discriminators. Sample spectra are shown, and the pulse heights measured are found to agree with theoretical calculations to within a factor of about 2. The response of the pyroelectric materials is found to be unaffected by exposure to about 10 Mrad of 2-7-MeV/u heavy ion radiation. With further study and improvement of the detection sensitivity, devices of this type could be applied to large-area space measurements of low ultraheavy-ion fluxes.

Simpson, J. A.

Detection of acoustic emission from composite laminates using PVF2 transducers

Polyvinylidene fluoride (PVF2), a semicrystalline polymer exhibiting piezoelectricity, is presently used as a sensing transducer in acoustic emission (AE) monitoring of several different composite laminate materials in order to obtain both quasi-static and fatigue loading results. AE signals obtained from PVF2 transducers are compared with those obtained by standard AE sensors. It is noted that PVF2 transducers may, through the application of spectral signal analysis, be able to distinguish between two distinct failure modes which have been observed in two composite laminates of the same material, but employing different lamina stacking sequences.

Stiffler, R.

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.

Effects of Radiation on Capacitor Dielectrics

Data gathered on key design parameters. Report discusses study of electrical and mechanical properties of irradiated polymer dielectric materials. Data compiled for use by designers of high-energy-density capacitors that operate in presence of ionizing radiation. Study focused on polycarbonates, polyetheretherketones, polymethylpentenes, polyimides (including polyetherimide), polyolefins, polysulfones (including polyethersulfone and polyphenylsulfone), and polyvinylidene fluorides.

Bouquet, F. L.

A study of the applicability of nucleation theory to quasi-thermodynamic transitions of second and higher Ehrenfest-order, supplement 3

The work includes an investigation of the applicability of the nucleation theory to second and higher order thermodynamic transitions in the Ehrenfest sense, and a number of significant conclusions relevant to first order transitions, as well. The underlying theoretical method consisted of expanding the Gibbs' free energy in a Maclarin or Taylor series and then using fundamental thermodynamic determinable quantities, and interpreting the results. Work was performed on the existence and interpretation of an interfacial energy between phases in a second order transition in addition to an investigation of the solid-liquid interfacial energy for various polymers. Extensive considerations were devoted to various aspects of a particular polymer, polyvinylidene fluoride (PVDF or PVF2), including an experimetal investigation of the effects of an applied electric field on the morphology of melt crystallization and on the nucleation and growth of polarized domains.

Barker, R. E., Jr.

Trajectory-capture cell instrumentation for measurement of dust particle mass, velocity and trajectory, and particle capture

The development of the polyvinylidene fluoride (PVDF) dust detector for space missions--such as the Halley Comet Missions where the impact velocity was very high as well as for missions where the impact velocity is low was extended to include: (1) the capability for impact position determination - i.e., x,y coordinate of impact; and (2) the capability for particle velocity determination using two thin PVDF sensors spaced a given distance apart - i.e., by time-of-flight. These developments have led to space flight instrumentation for recovery-type missions, which will measure the masses (sizes), fluxes and trajectories of incoming dust particles and will capture the dust material in a form suitable for later Earth-based laboratory measurements. These laboratory measurements would determine the elemental, isotopic and mineralogical properties of the captured dust and relate these to possible sources of the dust material (i.e., comets, asteroids), using the trajectory information. The instrumentation described here has the unique advantages of providing both orbital characteristics and physical and chemical properties--as well as possible origin--of incoming dust.

Simpson, J. A.

Acoustically based fetal heart rate monitor

The acoustically based fetal heart rate monitor permits an expectant mother to perform the fetal Non-Stress Test in her home. The potential market would include the one million U.S. pregnancies per year requiring this type of prenatal surveillance. The monitor uses polyvinylidene fluoride (PVF2) piezoelectric polymer film for the acoustic sensors, which are mounted in a seven-element array on a cummerbund. Evaluation of the sensor ouput signals utilizes a digital signal processor, which performs a linear prediction routine in real time. Clinical tests reveal that the acoustically based monitor provides Non-Stress Test records which are comparable to those obtained with a commercial ultrasonic transducer.

Baker, Donald A.

Instrumentation for near-Earth measurement of orbital debris and cosmic dust particles

Dust instrumentation based on polyvinylidene fluoride (PVDF) dust sensor arrays is described which will measure the masses, fluxes, velocities, and trajectories of orbital debris particles and natural micrometeoroids. Orbital debris particles are distinguished from natural particles (cosmic dust) by means of the velocity/trajectory information. The instrumentation will measure particle trajectory with a mean error of approximately 7 degrees (for isotropic flux) and is designed for measurements over the particle diameter range of approximately 2 to 200 micro-m. For future missions having Earth-return capabilities, arrays of capture cell devices positioned behind the PVDF trajectory system would provide for Earth-based chemical and isotopic analysis of captured dust.

Tuzzolino, Anthony J.

Microgravity isolation mounts based upon Piezoelectric film

The topics are presented in viewgraph form and include the following: a polyvinylidene fluoride (PVDF) actuator; a semi-active soft mount; a 3-axis experiment; low frequency disturbance attenuation; the control problem; and a 6-axis laboratory prototype.

Vonflotow, Andreas

Control of sound radiation with active/adaptive structures

Recent research is discussed in the area of active structural acoustic control with active/adaptive structures. Progress in the areas of structural acoustics, actuators, sensors, and control approaches is presented. Considerable effort has been given to the interaction of these areas with each other due to the coupled nature of the problem. A discussion is presented on actuators bonded to or embedded in the structure itself. The actuators discussed are piezoceramic actuators and shape memory alloy actuators. The sensors discussed are optical fiber sensors, Nitinol fiber sensors, piezoceramics, and polyvinylidene fluoride sensors. The active control techniques considered are state feedback control techniques and least mean square adaptive algorithms. Results presented show that significant progress has been made towards controlling structurally radiated noise by active/adaptive means applied directly to the structure.

Fuller, C. R.

Active vibration damping using smart material

We consider the modeling and active damping of an elastic beam using distributed actuators and sensors. The piezoelectric ceramic material (PZT) is used to build the actuator. The sensor is made of the piezoelectric polymer polyvinylidene fluoride (PVDF). These materials are glued on both sides of the beam. For the simple clamped beam, the closed loop controller has been shown to be able to extract energy from the beam. The shape of the actuator and its influence on the closed loop system performance are discussed. It is shown that it is possible to suppress the selected mode by choosing the appropriate actuator layout. It is also shown that by properly installing the sensor and determining the sensor shape we can further extract and manipulate the sensor signal for our control need.

Baras, John S.

Penetration of multiple thin films in micrometeorite capture cells

As part of a continuing effort to develop cosmic dust detectors/collectors for use in space, we performed a series of hypervelocity impact experiments on combined sensor/capture-cell assemblies using 10-200-micron-diameter glass projectiles and olivine crystals at velocities of 0.9-14.4 km/s. The design objective of the space-flight instrument is to measure the trajectories of individual particles with sufficient accuracy to permit identification of their parent bodies and to capture enough impactor material to allow chemical and isotopic analyses of samples returned to Earth. Three different multiple-film small-particle capture cell designs (0.1-100-micron-thick Al foils with approx. 10, 100, and 1800 micron spacing) were evaluated for their ability to capture impactor fragments and residue. Their performances were compared to two other types of capture cells, foil covered Ge crystals, and 0.50 and 0.120 g/cu cm aerogels. All capture cells were tested behind multifilm (1.4-6.0-micron-thick) polyvinylidene fluoride (PVDF) velocity/trajectory sensor devices. Several tests were also done without the PVDF sensors for comparison. The results of this study were reported by Simon in a comprehensive report in which the morphology of impacts and impactor residues in various types of capture cells after passage through two PVDF sensor films is discussed. Impactor fragments in selected capture cells from impacts at velocities up to 6.4 km/s were identified using scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS).

Simon, Charles G.

PVDF flux/mass/velocity/trajectory systems and their applications in space

The current status of the University of Chicago Polyvinylidene Fluoride (PVDF) flux/mass/velocity/trajectory instrumentation is summarized. The particle response and thermal stability characteristics of pure PVDF and PVDF copolymer sensors are described, as well as the characteristics of specially constructed two-dimensional position-sensing PVDF sensors. The performance of high-flux systems and of velocity/trajectory systems using these sensors is discussed, and the objectives and designs of a PVDF velocity/trajectory dust instrument for launch on the Advanced Research and Global Observation Satellite (ARGOS) in 1995 and of a high-flux dust instrument for launch on the Cassini spacecraft to Saturn in 1997 are summarized.

Tuzzolino, Anthony J.

The orbital debris detector consortium: Suppliers of instruments for in-situ measurements of small-particles in the space environment

Industry and university participants have joined together to form the IMPA:Ct consortium (In-situ Monitors of the Particulate Ambient: Circumterrestrial) which offers a broad range of flight qualified instruments for monitoring the small particle (0.1 micron to 10 cm) environment in space. Instruments are available in 12 months or less at costs ranging from 0.5 to 1.5 million dollars (US) for the total program. Detector technologies represented by these groups are: impact-induced capacitor-discharge (MOS, metal-oxide-silicon), cratering or penetration of electroactive thin film (polyvinylidene fluoride (PVDF)), impact-plasma detection, acoustic detection, CCD tracking of optical scatter of sunlight, and photodiode detection of optical scatter of laser light. The operational characteristics, general spacecraft interface and resource requirements (mass/power/telemetry), cost and delivery schedules, and points of contact for seven different instruments are presented.

Simon, C. G.

Ferroelectric Liquid Crystals In Aerodynamic Testing

The process of simultaneous optical visualization and quantitative measurement of aerodynamic boundary layer parameters requires new concepts, materials and utilization methods. Measurement of shear stress in terms of the transmitted or the reflected light intensity from an aligned ferroelectric liquid crystal (FLC) thin (approx. 1 micron) film deposited on a glass substrate has been the first step in this direction. In this paper, recent progress in utilization of FLC thin films for skin friction measurement and for studying the state of the boundary layer in a wind tunnel environment is reviewed. The switching characteristics of FLCs have been used to measure pressure from the newly devised system of partially exposed polymer dispersed ferroelectric liquid crystals (PEPDFLCs). In this configuration, a PEPDFLC thin film (approx. 10-25 microns) is sandwiched between two transparent conducting electrodes, one a rigid surface and the other a flexible sheet such as polyvinylidene fluoride or mylar. The switching characteristics of the film are a function of the pressure applied to the flexible transparent electrode and a predetermined bias voltage across the two electrodes. The results, considering the dielectrics of composite media, are discussed.

Parmar, Devendra S.