Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polyethylene Moderator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Data Testing of Polyethylene Thermal Scattering Law with New Thermal Epithermal eXperiments (TEX) Plutonium Baseline Benchmark, PU-MET-MIXED-002

Five plutonium baseline experiments completed in September of 2018 from the Thermal Epithermal eXperiments (TEX) program have been accepted by the International Criticality Safety Benchmark Evaluation Project as PU-MET-MIXED-002 and will be included in the 2020 version of the handbook. The experiments were made up of stacked layers of plutonium Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene (PE, chemical formula C2H4) to varying degrees to create configurations with five different neutron spectra, including one fast configuration, one thermal configuration, and three mixed configurations. Calculations of the benchmark show overprediction of k eff when using the most recent release of the Evaluated Nuclear Data File Version B (ENDF/B) library release (VIII.0) cross sections, particularly when compared to the previous ENDF/B-VII.1 results. One potential source of overprediction was hypothesized to be the new Molecular Dynamics (MD) generated PE Thermal Scattering Law (TSL). The overprediction was shown via calculation to not be caused by the new ENDF/B-VIII.0 thermal scattering law, and in fact the overprediction was mitigated by the new PE TSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Validation of Thermal Scattering Evaluations

In order to test the performance of new neutron thermal scattering law (TSL) evaluations it is desirable to have experimental data that is highly sensitive to the TSL and provides high fidelity information on the energy dependent performance of TSL evaluations. Three relevant experiments are discussed including: accurate thermal total cross section measurements, thermal neutron die-away experiments, and neutron leakage experiments. The experimental setups and results are reviewed, and examples provided for some moderators including polyethylene, Plexiglas, and YHx. For the experiments preformed thus far, there is generally good agreement between the measured total cross section and simulations using current TSL evaluations, however in certain energy ranges differences were observed. Similarly, neutron die-away and leakage measurements for samples at room temperature are in good agreement with data computed from TSLs, however leakage measurements for polyethylene at 29K show discrepancies with TSL evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TEX-Cl: Integral Experiment Execution of Thermal/Epithermal eXperiments using Highly Enriched Uranium with Polyethylene and Chloride Absorbers

This report documents the experimental configurations and measurements performed for IER-499, TEX with chlorine (TEX-Cl). TEX-Cl is a variant of the TEX-HEU campaign and utilizes highly enriched uranium fuel, high-density polyethylene (HDPE) moderators and reflectors, and interstitial NaCl salt absorbers. These experiments probe the chlorine (from the sodium chloride) absorption cross section in the thermal and intermediate neutron energy regimes, with a small portion in the fast neutron energy regime. Three configurations were selected by maximizing the sensitivity in k eff to the needs of Y-12 for their electrorefining operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uranium plasma emission at gas-core reaction conditions

The results of uranium plasma emission produced by two methods are reported. For the first method a ruby laser was focused on the surface of a pure U-238 sample to create a plasma plume with a peak plasma density of about 10 to the 20th power/cu cm and a temperature of about 38,600 K. The absolute intensity of the emitted radiation, covering the range from 300 to 7000 A was measured. For the second method, the uranium plasma was produced in a 20 kilovolt, 25 kilojoule plasma-focus device. The 2.5 MeV neutrons from the D-D reaction in the plasma focus are moderated by polyethylene and induce fissions in the U-235. Spectra of both uranium plasmas were obtained over the range from 30 to 9000 A. Because of the low fission yield the energy input due to fissions is very small compared to the total energy in the plasma.

Williams, M. D.↗

Investigating the AGN-201M research reactor's unique dominance ratio

The AGN-201M reactor is a small, thermal spectrum reactor located at the University of New Mexico (UNM). It is moderated by polyethylene, reflected by graphite, with fuel comprised of uranium microspheres embedded in polyethylene plates that are separated by an aluminum baffle. The dominance ratio of a multiplying system is the ratio of the first higher-mode eigenvalue to the fundamental, k{sub 1}/k{sub 0}. It is a key parameter in characterizing the rate of convergence, analyzing system stability, and determining how tightly coupled the system's neutron fission is. The purpose of this paper is to investigate the system's unusually low dominance ratio of 0.632. This investigation varied the reactor's physical parameters, such as the fuel geometry, fuel density, and reflector thickness, and examined their impact on the reactor's dominance ratio. Additionally, this study examined neutronically similar systems in hopes of identifying common causes for systems with low dominance ratios. The reason why the dominance ratio of the reactor is small compared to larger thermal reactors was determined to be because of its significantly smaller geometry and the composition of the fuel plates. The reflector's effect on the dominance ratio is small in comparison to the other factors, but was found to have a non-zero effect. Furthermore, the AGN-201M was found to have a significantly lower dominance ratio than systems in which it shares a very high (c{sub k} >95%) degree of neutronic similarity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Case for and Against a Gadolinium Bias in SCALE: Round 2

The “Opening Arguments” for and against a gadolinium bias in SCALE were presented at the American Nuclear Society Annual Meeting in Philadelphia, Pennsylvania, in June, 2018. Some critical experiments included in the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data (VALID) indicate a significant bias as a function of gadolinium concentration. Other experiments indicate that no significant bias exists. The work presented here develops a larger suite of gadolinium-bearing benchmark models to further examine code, data, and benchmark performance. The new benchmark models have been reviewed for accuracy, but documentation and review for addition to the VALID library have not been completed. The problematic benchmarks included in VALID are HEU-SOL-THERM-014 and -016. These are two evaluations from a series of experiments from the Institute for Physics and Power Engineering (IPPE), Russia, documented in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The entire set of evaluations also includes HEU-SOL-THERM-015, -017, -018, -019, and -025. Each evaluation contains a different uranium concentration, and different configurations within each evaluation include different gadolinium concentrations. These 7 evaluations contain a total of 52 configurations and form the largest subset of experiments considered, and they allow for a more complete assessment of the performance of these benchmarks than has historically been possible using just the HEU-SOL-THERM-014 and -016 results. Additional solution experiments are considered, including MIX-SOL-THERM-006 and -007 and PU-SOL-THERM-034. MIX-SOL-THERM-007 is in the VALID library, whereas MIX-SOL-THERM-006 and PU-SOL-THERM-034 are not. The results for MIX-SOL THERM-007 have not shown a gadolinium trend. These mixed- and plutonium-fueled solutions include 28 configurations. Some experiments including solid fuel and solid gadolinium are also included. These experiments include highly enriched uranium (HEU) foils moderated with polyethylene in HEU-MET-THERM-010, -016, and -034, and low enriched uranium (LEU) pin arrays with gadolinia absorber rods in LEU-COMP THERM-036 and -043. A total 32 cases with solid fuel are included. The IPPE solution benchmarks show a fairly high degree of variability, but no clear trend as a function of gadolinium concentration can be observed. The mixed- and plutonium-fueled solutions show less variability than the HEU solutions and also no trend relative to gadolinium concentration. The solid-fueled experiments also show no trend as a function of gadolinium content. The entire set of benchmarks shows no clear trend on gadolinium content or the energy of the average neutron lethargy causing fission.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal cross section measurements at the RPI LINAC [Abstract]

Recently, a cold moderator was designed and developed for use at the RPI LINAC. This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0006 – 20 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0007 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0006 – 3 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integral Experiment Final Design for Thermal/Epithermal eXperiments (TEX) using Highly Enriched Uranium with Polyethylene at Low Temperature (IER-479 CED-2 Report)

The goal of IER-479 is to design uranium critical experiments that can be used to validate low temperature cross sections and criticality safety analyses over multiple neutron energy regimes. Currently, there are no benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook at temperatures lower than room temperature (International Criticality Safety Benchmark Evaluation Project Handbook, 2019). However, there are many needs for validation of criticality safety analysis at lower temperatures, including meeting transportation requirements and operations conducted outside or in unheated facilities. Additionally, NCSP has funded North Carolina State (NCSU) to generate new thermal scattering laws, including at lower temperatures, and the lack of integral benchmarks impedes data testing of these new cross sections. To address these needs, this report will present a critical experiment design covering various fission energy regimes with a goal temperature of -40°C (-40°F), which is based on the lower bound of expected non-cryogenic operational temperatures. The goal of the U.S. Nuclear Criticality Safety Program’s (NCSP) Thermal/Epithermal eXperiments (TEX) is to design and conduct new critical experiments to address high priority nuclear data needs from the nuclear criticality safety and nuclear data communities. The TEX program includes two series of baseline experimental configurations, one based on plutonium fuel (plutonium-aluminum Zero Power Physics Reactor (ZPPR) plates) and the other based on uranium fuel (highly enriched uranium (HEU) plates), that are moderated with varying thickness of polyethylene to create assemblies which span the thermal, intermediate, and fast fission energy regimes. The configurations are designed to be easily modified (for example, to add diluent materials of interest) to allow for efficient generation of additional benchmark configurations and allow for added nuclear data testing utility when comparing modified configurations to baseline configurations. The goal of IER-479 is to use the TEX-HEU concept (stack of HEU plates and polyethylene moderators) to design a critical experiment that can be used to validate low temperature cross sections and criticality safety analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Cross Section Measurements At The RPI LINAC

Recently, a cold moderator was designed and developed for use at the Rensselaer Polytechnic Institute Linear Accelerator (RPI LINAC). This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by up to a factor of 8 by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Furthermore, following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0005 – 1 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0005 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0005 – 1 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of sub-thermal neutron flux through cold polyethylene

Total thermal neutron cross section measurements serve as the primary means of validation for thermal neutron scattering kernels, an important quantity for neutron transport calculations. In an effort to improve the quality of thermal neutron scattering kernels, researchers at Rensselaer Polytechnic Institute (RPI) designed and constructed a polyethylene based cold moderation system to enhance neutron flux below 10 meV when coupled with the Enhanced Thermal Target (ETT) at the RPI Gaerttner LINAC. The final design yielded an increase in sub-thermal neutron flux (below 10 meV) by a factor of 4.5 for a moderator temperature of 37.5 K relative to the ETT alone. A further increase to a factor of 6 is expected after a minor geometry modification and decrease in polyethylene temperature to 25 K. This novel capability will be used to conduct total thermal neutron cross section measurements from 0.0005–10 eV for different materials including moderator materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integral Experiment Execution of Thermal or Epithermal eXperiments using Plutonium with Polyethylene and Iron, IER 519, TEX-Hanford (-Iron), CED-3b

This report documents the execution of experiments and measurements for IER 519, Thermal/Epithermal eXperiments (TEX) for Hanford applications, using plutonium Zero Power Physics Reactor (ZPPR) plates moderated by interstitial polyethylene and iron (Fe) absorber plates. Initial hand stack, mass, and dimensional measurements were performed in July 2025. The experiments were completed over three weeks from December 2025 to January 2026 at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Sites (NNSS). All photos and critical data were provided by NCERC and experimenters in LANL’s NEN-2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Production of fissioning uranium plasma to approximate gas-core reactor conditions

The intense burst of neutrons from the d-d reaction in a plasma-focus apparatus is exploited to produce a fissioning uranium plasma. The plasma-focus apparatus consists of a pair of coaxial electrodes and is energized by a 25 kJ capacitor bank. A 15-g rod of 93% enriched U-235 is placed in the end of the center electrode where an intense electron beam impinges during the plasma-focus formation. The resulting uranium plasma is heated to about 5 eV. Fission reactions are induced in the uranium plasma by neutrons from the d-d reaction which were moderated by the polyethylene walls. The fission yield is determined by evaluating the gamma peaks of I-134, Cs-138, and other fission products, and it is found that more than 1,000,000 fissions are induced in the uranium for each focus formation, with at least 1% of these occurring in the uranium plasma.

Lee, J. H.↗

TEX-Hf: Integral Experiment Execution of Thermal/Epithermal eXperiments using Highly Enriched Uranium with Polyethylene and Hafnium (IER-532 CED-3b Report)

This report documents the experimental configurations and measurements for IER-532, Thermal/Epithermal eXperiments (TEX) with highly enriched uranium (HEU) fuel and interstitial hafnium (Hf), moderated and reflected by polyethylene. TEX-Hf is a variation of and based on the TEX-HEU (IER-297) design, with the inclusion of hafnium. These configurations provide integral experiments for validation of hafnium in the thermal, intermediate, and fast neutron energy regimes by maximizing the sensitivity in k eff to the hafnium isotope cross sections. The experiment campaign was completed over seven weeks during the end of FY22 and beginning of FY23 at the National Critical Experiments Research Center at the Nevada National Security Site. The campaign produced seven experimental configurations, four reproducibility measurements, and many additional dimensional measurements that will be of use to the future benchmark evaluation of this experiment and other experiments using the same HEU fuel. Table 1 summarizes the TEX-Hf experimental configurations, including their physical parameters, calculated fission fractions, and estimated excess reactivities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The CWS Experiments – An Experimental Study of the Effects of Chlorine on Thermal Neutron Absorption

The Chlorine Worth Study (CWS) experiments consist of layers of Zero Power Physics Reactor plates moderated by high density polyethylene, polyvinyl chloride, and chlorinated polyvinyl chloride with the goal to produce a thermal critical experiment. A thick high density polyethylene reflector surrounds the experiments. Aluminum fuel trays and frames were used to conduct the intrinsic heat generation of the plutonium plates away from the core and out to the top plate and the platen, both acting as heat sinks. The goal of the CWS experiments was to provide benchmark critical experiments that were sensitive to chlorine and matched the sensitivity of criticality safety applications for aqueous chloride operations at PF-4 at Los Alamos National Laboratory. The specific aqueous chloride PF-4 applications were solutions of 30 g/L plutonium, 300 g/L plutonium, and 600 g/L plutonium. The CWS experiments were designed using prototype methods developed by the ARCHIMEDES and EUCLID projects at Los Alamos National Laboratory. The CWS experiments were performed in December of 2021 at the National Criticality Experiments Research Center at the Nevada Nuclear Security Site on the Planet critical assembly. It is intended that the CWS experiments will be evaluated and submitted to the ICSBEP in the future as criticality safety benchmarks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Cross Section Measurements At The RPI LINAC [Slides]

This presentation gives an overview of thermal cross section measurements at the RPI LINAC. Work discussed includes novel cold moderator capability for use in extending neutron flux down to 0.0005 eV and total thermal neutron cross section measurements performed for polyethylene, polystyrene, Plexiglas (Lucite), and yttrium hydride over the entire thermal region (0.0005 – 1 eV).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid‐Adsorbed Polymer‐Electrolyte Interphases for Stabilizing Metal Anodes in Aqueous Zn and Non‐Aqueous Li Batteries

Abstract Polymers are known to adsorb spontaneously from liquid solutions in contact with high‐energy substrates to form configurationally complex, but robust phases that often exhibit higher durability than might be expected from the individual physical bonds formed with the substrate. Rational control of the physical, chemical, and transport properties of such interphases has emerged as a fundamental opportunity for scientific and technological advances in energy storage technology but requires in‐depth understanding of the conformation states and electrochemical effect of the adsorbed polymers. Here, we analyze the interfacial adsorption of oligomeric polyethylene glycol (PEG) chains of moderate sizes dissolved in protic and aprotic liquid electrolytes and find that there is an optimum polymer molecular weight of approximately 400 Da at which the highest columbic efficiency is achieved for both Zn and Li deposition. These findings point to a simple, versatile approach for extending the lifetime of batteries.

Jin, Shuo↗