Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plutonium Simulants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

How to Safely Build 100-plus Kilograms of Weapons-Grade Plutonium

The goal of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project was to reduce compensating errors by utilizing machine learning to both help determine which reactions contain compensating errors as well as optimizing an experiment which can be used to maximally reduce these errors. Compensating errors can adversely impact the predictive power of application simulations, and therefore it’s useful to further constrain nuclear data and reduce these errors. The EUCLID project included building two configurations at the National Criticality Experiments Research Center (NCERC). These two configurations had very different geometries (one was cube-like and one was slab-like). Previous works focus on selection of the target experiment(s), radiation transport capabilities developed in the project, the experiment optimization, and the performance of the experiments. This work will focus only on the safety aspects of performing this experiment, which utilized over 100 kg of weapons-grade plutonium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Measurement Uncertainties in the Jupiter High-240 Experiment

The Jupiter High-240 experiment performed in May of 2019 was previously discussed as a variant of the original Jupiter experiment incorporating plutonium metal alloy fuel plates with higher 240Pu content and lead plates, using both a reference configuration and a second configuration where eight lead plates were replaced with aluminum to simulate voiding. Measurements were recorded for experiment period, the “pressure” of the Comet ram upon closure for each near-critical measurement, and temperature. The experiment reactor period is the time it would take to increase the neutron population by a factor of e. For this experiment, the copper reflectors and upper third of the fuel sits upon a support structure with the lower fuel arrays raised up into the center of the reflectors using a ram (see Fig. 1). The recorded logbook temperature for each measurement corresponds to a resistance temperature detector (RTD) located at the top center of the upper fuel array. This paper summarizes the evaluated uncertainties for the Jupiter High 240 experiment as contributed via the recorded measurements and nuclear data and their assessed impact upon the computation of system reactivity and eigenvalue.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plutonium Production Reactor Progression Problems: Magnox Neutronics Benchmarks

The goal of this document is to provide a set of comprehensive benchmarking neutronics problems for gas-cooled, graphite-moderated reactors. The problems are designed to be representative problems that increase in complexity to test performance of various codes. For the simulation of the benchmarking problems, the Shift Monte Carlo code and MPACT deterministic code are chosen because of their state-of-the-art capabilities, which are optimized for various reactor designs. Because these codes have been developed primarily for light water reactor applications, their application to graphite-moderated, gas-cooled reactors has not been extensively explored. This report attempts to evaluate benchmarks for a Magnox-style reactor, one that is graphite-moderated and gas-cooled. Parameters that are calculated and presented in this benchmark include the eigenvalue, peaking factors, and isotope concentrations. Results show good agreement between Shift and MPACT, and demonstrate the capability of MPACT to model graphite-moderated systems well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Plutonium Retention by Crystalline Silicotitanate under Hyperalkaline Conditions Relevant to Tank-Side Cesium-Removal at the Hanford Site

Crystalline silicotitanate (CST) is used in Hanford’s Tank-Side Cesium-Removal (TSCR) process to selectively remove Cs-137 from highly caustic, nitrate-rich tank supernatants. Recent testing with actual waste samples suggests that CST can also retain measurable plutonium (Pu), which could affect radiological classification and disposal pathways for spent CST. To quantify this behavior, Pu partitioning to CST was studied under Hanford-relevant conditions using batch-contact experiments in a representative simulant (2 M NaNO3, 0.7 M NaOH). Isotherm data were measured and distribution ratios calculated, with Cs+ uptake used as benchmark. Under low-carbonate conditions, Pu was retained strongly by CST in systems initially contacted with either PuO2 nanoparticles (Pu(IV)) or aqueous Pu(VI), with distribution ratios of ~2,200–3,700 mL/g, generally exceeding those for Cs+ (~400–1,000 mL/g). Increasing carbonate concentration strongly reduced PuO2 nanoparticle retention; at [Na2CO3] = 1 M, distribution ratios decreased by up to one order of magnitude to roughly 100–300 mL/g. Electron microscopy suggests that Pu retention involves a combination of mechanisms such as PuO2 NP aggregation induced by CST leachate components, and association with CST bead surfaces.

Neumann, J.↗

Importance of 3-D S{sub N} depletion in non-proliferation using BSOLVE

We present a single Pressurized Water Reactor (PWR) 3-D fuel rod design for depletion analysis using BSOLVE, our newly developed Runge-Kutta-Fehlberg based depletion code. BSOLVE is coupled with the deterministic 3-D S{sub N} particle transport code, PENTRAN, applied here with a 4-neutron energy group comparison to Continuous Energy (C/E) SERPENT2 Monte Carlo results. Differences are expected, as PENTRAN+BSOLVE retains full (multi-group) energy information for reactions, nuclide specific fission contributions, and energy dependent fission yields, using the latest available ENDF-BVIII data, important to retain accurate burned fuel inventories; SERPENT2 collapses burnup reactions to a single energy value. For depletion times up to ∼ 700 days and typical PWR power densities, relative differences between multigroup 3-D S{sub N} with full energy data and Monte Carlo one group burnup for trans-uranium nuclide concentrations and fission products are up to ∼20%. System eigenvalues are consistent, but with differences early and late in the cycle attributed to multigroup vs. C/E Monte Carlo cross sections. This work highlights the importance of low variance transport driven burnup for non-proliferation concerns, since plutonium quality varies significantly along axial lengths, and is more challenging to converge using Monte Carlo; details of depletion steps with spatial/zone dependent plutonium quality are provided. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks

Confidently designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear applications. This type of analysis relies on matching new nuclear applications with existing benchmark experiments. The Whisper-1.1 software package included in MCNP6.2 ®1 contains more than 1,100 International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks. These benchmarks however rarely match new nuclear applications. The number of benchmarks available to match a given set of materials or geometric configurations varies significantly. Furthermore, recently performed benchmark experiments may not have had enough time to be properly documented and published. Benchmarks are vital for determining the accuracy of nuclear data and can assist nuclear physics and evaluators in improving nuclear data libraries. Exhaustively exploring the parameter space using simulations with software such as MCNP is too computationally expensive. In this work, Gaussian process optimization was implemented to reduce the number of simulations needed for optimization over multiple parameters. This optimization scheme was designed to selectively generate new benchmarks with high sensitivity-based similarity metrics to user-defined nuclear applications. Two benchmark models of spherically nested shells containing plutonium, uranium, tantalum, and water were used in the optimization to match an application containing plutonium plates, stacked in a tantalum reflector, surrounded by water.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature sensitivity of the equilibrium neutronics and accident analysis of the HTR-10

Pebble-Bed High-Temperature Gas-cooled Reactors (PB-HTGR) are moderated by the graphite in the fuel pebbles and the graphite reflector surrounding the pebble-bed. Because graphite is by far the most abundant material in PB-HTGRs and the primary moderator, accurate modeling of the graphite material, including density, impurities, and temperatures, is crucial for accurate computational modeling and simulation of these reactors. While main characteristics of the graphite components are often known, the local temperature is less well known and often averaged over all components. Here, this work studies the impact of considering accurate temperature profiles in the graphite material on the generation of a small PB-HTGR model at the state of equilibrium operation and on short-term accident progression. The fuel compositions for the PB-HTGR were determined using a jump-in equilibrium modeling method, the Axial Radial Zone Equilibrium Modeling (AR-ZEM) method. In contrast to previous work, the AR-ZEM method was used considering thermal-hydraulic feedback from the MELCOR code to determine temperatures of the fuel pebbles and the surrounding graphite reflector. The consideration of an axial and radial temperature profile in the core and reflector, as opposed to uniform material temperatures, had an impact of almost 1,300 pcm on the equilibrium core eigenvalue and caused significant differences in the discharged plutonium fuel inventory with up to 4.9% and 11.0% for Pu-239 and Pu-242, respectively. To assess the impact on short-term accident progression, two Anticipated Transient Without SCRAM (ATWS) events, a Pressurized Loss of Forced Coolant (PLOFC) and a Control Rod Withdrawal (CRW) with loss of flow, were simulated with MELCOR. The use of temperature profiles in the equilibrium core models did not reveal a significant impact on the temperature, power, or reactivity responses during the transients. In conclusion, a need for consideration of accurate temperature profiles, in particular for the graphite reflector, was found for the generation of equilibrium PB-HTGRs core models using jump-in methods, but detailed temperature profiles may not be necessary when performing conservative transient analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary verification of the MCNP perturbation and fixed-source tally sensitivity tools

Integral benchmark experiments are vital in the adjustment and validation of the nuclear data that govern predictive simulations across the nuclear community. The nuclear data sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®) transport code are currently limited; however, expanding sensitivity capabilities will allow benchmark experiments to be designed to resolve compensating errors and adjust nuclear data where previously prohibitively difficult. This paper provides details of a preliminary verification for the use of (i.) the recently revised perturbation and (ii.) developmental fixed-source sensitivity tools within MCNP to calculate sensitivities of tallied responses (such as current integrated over a surface, F1, and flux averaged over a cell, F4) to nuclear data in fixed-source simulations. Energy-binned and energy-integrated sensitivities calculated with these tools are compared against sensitivities calculated using a central-difference approximation. Here, the verification is completed for four configurations of a benchmarked system using a 4.5-kg plutonium sphere surrounded by varying amounts of copper and/or polyethylene. The results show that sensitivities calculated with the perturbation and fixed-source sensitivity tools agree with the central-difference-based approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha Analysis of Thermal/Epithermal eXperiments Optimized for Polyethylene Thermal Neutron Scattering

Accurate nuclear data is the foundation for predictive simulations and design of new experimental in the nuclear community. The criticality safety community has particular interest in benchmarking assemblies with thermal neutron data. To address such needs the Nuclear Criticality Safety Program (NCSP) funded the Thermal/Epithermal eXperiments (TEX) campaigns that were to be completed between Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL). Specifically, analysis of plutonium with a thermal neutron spectrum expands on previous work to help validate thermal scattering law data, which can have larger impacts in thermal applications. The first of these experiments were successfully conducted in 2018, but this paper will focus on the 2021 measurement focused on investigating the the thermal scattering law (TSL) for polyethylene. These experiments were successfully conducted at the National Criticality Experiments Research Center (NCERC) using the Planet vertical lift critical assembly machine. Polethylene plates were layered with trays of Zero Power Physics Reactor (ZPPR) 24 plates in a 12" by 12" square. The ZPPR plates were 2" by 3" by 0.125" bearing weapons grade plutonium. The polyethylene moderator was either 2" or 1.6875" thick. This work builds on the Rossi-alpha calculations done by McKenzie et al. for the same detector-assembly system and will only focus on the Rossi-alpha neutron noise method. This work will aim to further validate the results of the experiment through a novel neutron noise python package. Following similar methodology to the previous analysis, analysis of TEX evaluated the prompt neutron decay constant at delayed critical, $α_{DC}$ using Rossi-alpha for different polyethylene moderator thicknesses. These results will help improve understanding of TSL in critical experiments. Alpha (α), is the prompt neutron decay constant of the measured system and allows for the evaluation of a systems propensity to sustain fission chains via prompt neutrons. The single value description of the assemblies allow for comparison between experiments regardless of composition, geometry, and reflectors/moderators. Rossi-alpha measurements were performed on the polyethylene moderated TEX experiments to estimate $α_{DC}$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nondestructive and destructive assay for forensics characterization of weapons-grade plutonium produced in LEU irradiated in a thermal neutron spectrum

A post-irradiation examination (PIE) of an enriched uranium sample was performed to advance a nuclear forensics methodology, based on intra-elemental nuclide ratios. The PIE was carried out on a few milligrams of low enriched uranium dioxide (LEUO 2 ) sample, irradiated to a burnup of 1 GWd/MTU. The PIE of the LEUO 2 sample provided the concentration of selected plutonium and fission product nuclides ( 239 Pu, 240 Pu, 241 Pu, 91 Y, 95 Zr, 95 Nb, 103 Ru, 133 Cs, 134 Cs, 135 Cs, 137 Cs, 136 Ba, 138 Ba, 140 Ba, 140 La, 141 Ce, 144 Ce, 149 Sm, 150 Sm, 152 Sm, 153 Eu, and 154 Eu). The PIE supported validation of the MCNP (Monte Carlo N-Particle neutronics simulation code) predicted concentration of these nuclides in the irradiated LEUO 2 sample. This study showed that most of the MCNP predicted nuclide concentrations were within 15% and several within 10% compared to the PIE results. Furthermore, gamma and mass spectrometry of nuclides in irradiated LEUO 2 enabled the determination of uranium burnup and time since irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis and thermophysical property determination of NaCl-PuCl3 salts

Currently, a knowledge gap exists in the available data and understanding of thermophysical properties relating to fresh fuel salts, especially those containing plutonium. These data are necessary for designing, constructing, and licensing future commercial molten-salt reactors. Thermophysical properties, such as melting temperature, salt stability, density, and heat capacity were ascertained using NaCl-PuCl3 (36 mol% PuCl3) and a more sodium rich composition containing 25 mol% PuCl3. The NaCl-PuCl3 salt mixture was synthesized for this study and contained 63.4 mol% NaCl, 36.3 mol% PuCl3 and was 99.7% pure. Upon heating, the NaCl–PuCl3 eutectic was stable at temperatures up to 800 °C. The onset of melting occurred at 451 ± 3 °C, and the enthalpy of fusion was determined to be 23.0 ± 1.4 kJ/mol. Heat capacity measurements in the liquid phase ranged from 107.7 to 91.3 J/mol.K, with an average value of 104.6 ± 11.4 J/mol.K between 500 and 650 °C. Three independent trials of the molten NaCl-PuCl3 salt found the density to be ?(T) = 3.8589 – 9.5342·10-4 T(°C). In addition, ab initio molecular dynamic simulations to calculate density and heat capacity values are included.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER-517: Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK)

Nuclear criticality experiments are essential to the validation of nuclear data used in simulation software. The quality of nuclear data becomes paramount as simulation software becomes more relied upon for criticality safety studies and designs of nuclear systems. To improve the quality of nuclear data, experimenters can design critical experiments that are sensitive to isotope reaction pairs in materials of interest. The efforts conducted by the Organisation for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA) Working Party on Nuclear Criticality Safety (WPNCS) Subgroup 8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks (SG8) to categorize benchmarks according to their usefulness for nuclear data validation have been of great importance. Based on the OECD studies benchmark experiments included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook are concisely used by nuclear data evaluators, criticality safety engineers and others to validate nuclear data and simulation results. A lack of benchmarks sensitive to molybdenum in the (ICSBEP), particularly in the intermediate range, was noted by Los Alamos National Laboratory (LANL), the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), and Y-12 National Security Site prompting them to submit a joint integral experiment request to the Nuclear Criticality Safety Program (NCSP) in 2019. The request included both HEU and Plutonium systems in order to validate differential nuclear data focusing on the intermediate energy range but also includes thermal and fast configurations. This document represents the preliminary design work for a series of molybdenum integral experiments known as Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vadose Zone Model for B Plant Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3. Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The scope of this ECF is to document the development and results of the B Plant Area vadose zone model. The B Plant Area model encompasses the region around B Plant (221-B) in the western part of 200 East Area. The plant was used to separate plutonium from irradiated fuel using the bismuth-phosphate process from 1945 to 1956, and for strontium and cesium recovery from 1968 to 1985.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗