Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Platform Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nonlinear Motion Cueing Algorithm: Filtering at Pilot Station and Development of the Nonlinear Optimal Filters for Pitch and Roll

Telban and Cardullo have developed and successfully implemented the non-linear optimal motion cueing algorithm at the Visual Motion Simulator (VMS) at the NASA Langley Research Center in 2005. The latest version of the non-linear algorithm performed filtering of motion cues in all degrees-of-freedom except for pitch and roll. This manuscript describes the development and implementation of the non-linear optimal motion cueing algorithm for the pitch and roll degrees of freedom. Presented results indicate improved cues in the specified channels as compared to the original design. To further advance motion cueing in general, this manuscript describes modifications to the existing algorithm, which allow for filtering at the location of the pilot's head as opposed to the centroid of the motion platform. The rational for such modification to the cueing algorithms is that the location of the pilot's vestibular system must be taken into account as opposed to the off-set of the centroid of the cockpit relative to the center of rotation alone. Results provided in this report suggest improved performance of the motion cueing algorithm.

Zaychik, Kirill B.↗

Preliminary investigation of motion requirements for the simulation of helicopter hover tasks

Data from a preliminary experiment are presented which attempted to define a helicopter hover task that would allow the detection of objectively-measured differences in fixed base/moving base simulator performance. The addition of heave, pitch, and roll movement of a ship at sea to the hover task, by means of an adaption of a simulator g-seat, potentially fulfills the desired definition. The feasibility of g-seat substitution for platform motion can be investigated utilizing this task.

Parrish, R. V.↗

Machine Vision for Relative Spacecraft Navigation During Approach to Docking

This paper describes a machine vision system for relative spacecraft navigation during the terminal phase of approach to docking that: 1) matches high contrast image features of the target vehicle, as seen by a camera that is bore-sighted to the docking adapter on the chase vehicle, to the corresponding features in a 3d model of the docking adapter on the target vehicle and 2) is robust to on-orbit lighting. An implementation is provided for the case of the Space Shuttle Orbiter docking to the International Space Station (ISS) with quantitative test results using a full scale, medium fidelity mock-up of the ISS docking adapter mounted on a 6-DOF motion platform at the NASA Marshall Spaceflight Center Flight Robotics Laboratory and qualitative test results using recorded video from the Orbiter Docking System Camera (ODSC) during multiple orbiter to ISS docking missions. The Natural Feature Image Registration (NFIR) system consists of two modules: 1) Tracking which tracks the target object from image to image and estimates the position and orientation (pose) of the docking camera relative to the target object and 2) Acquisition which recognizes the target object if it is in the docking camera Field-of-View and provides an approximate pose that is used to initialize tracking. Detected image edges are matched to the 3d model edges whose predicted location, based on the pose estimate and its first time derivative from the previous frame, is closest to the detected edge1 . Mismatches are eliminated using a rigid motion constraint. The remaining 2d image to 3d model matches are used to make a least squares estimate of the change in relative pose from the previous image to the current image. The changes in position and in attitude are used as data for two Kalman filters whose outputs are smoothed estimate of position and velocity plus attitude and attitude rate that are then used to predict the location of the 3d model features in the next image.

Chien, Chiun-Hong↗

Visual Acuity Using Head-fixed Displays During Passive Self and Surround Motion

The ability to read head-fixed displays on various motion platforms requires the suppression of vestibulo-ocular reflexes. This study examined dynamic visual acuity while viewing a head-fixed display during different self and surround rotation conditions. Twelve healthy subjects were asked to report the orientation of Landolt C optotypes presented on a micro-display fixed to a rotating chair at 50 cm distance. Acuity thresholds were determined by the lowest size at which the subjects correctly identified 3 of 5 optotype orientations at peak velocity. Visual acuity was compared across four different conditions, each tested at 0.05 and 0.4 Hz (peak amplitude of 57 deg/s). The four conditions included: subject rotated in semi-darkness (i.e., limited to background illumination of the display), subject stationary while visual scene rotated, subject rotated around a stationary visual background, and both subject and visual scene rotated together. Visual acuity performance was greatest when the subject rotated around a stationary visual background; i.e., when both vestibular and visual inputs provided concordant information about the motion. Visual acuity performance was most reduced when the subject and visual scene rotated together; i.e., when the visual scene provided discordant information about the motion. Ranges of 4-5 logMAR step sizes across the conditions indicated the acuity task was sufficient to discriminate visual performance levels. The background visual scene can influence the ability to read head-fixed displays during passive motion disturbances. Dynamic visual acuity using head-fixed displays can provide an operationally relevant screening tool for visual performance during exposure to novel acceleration environments.

Wood, Scott J.↗

Coherent Doppler Laser Radar: Technology Development and Applications

NASA's Marshall Space Flight Center has been investigating, developing, and applying coherent Doppler laser radar technology for over 30 years. These efforts have included the first wind measurement in 1967, the first airborne flights in 1972, the first airborne wind field mapping in 1981, and the first measurement of hurricane eyewall winds in 1998. A parallel effort at MSFC since 1982 has been the study, modeling and technology development for a space-based global wind measurement system. These endeavors to date have resulted in compact, robust, eyesafe lidars at 2 micron wavelength based on solid-state laser technology; in a factor of 6 volume reduction in near diffraction limited, space-qualifiable telescopes; in sophisticated airborne scanners with full platform motion subtraction; in local oscillator lasers capable of rapid tuning of 25 GHz for removal of relative laser radar to target velocities over a 25 km/s range; in performance prediction theory and simulations that have been validated experimentally; and in extensive field campaign experience. We have also begun efforts to dramatically improve the fundamental photon efficiency of the laser radar, to demonstrate advanced lower mass laser radar telescopes and scanners; to develop laser and laser radar system alignment maintenance technologies; and to greatly improve the electrical efficiency, cooling technique, and robustness of the pulsed laser. This coherent Doppler laser radar technology is suitable for high resolution, high accuracy wind mapping; for aerosol and cloud measurement; for Differential Absorption Lidar (DIAL) measurements of atmospheric and trace gases; for hard target range and velocity measurement; and for hard target vibration spectra measurement. It is also suitable for a number of aircraft operations applications such as clear air turbulence (CAT) detection; dangerous wind shear (microburst) detection; airspeed, angle of attack, and sideslip measurement; and fuel savings through headwind minimization. In addition to the airborne and space platforms, a coherent Doppler laser radar system in an unmanned aerial vehicle (UAV) could provide battlefield weather and target identification.

Kavaya, Michael J.↗

Design and simulation of closed-loop ground alignment of inertial platforms with sway motion

This paper is concerned with the application of optimal estimation and control concepts to the ground alignment of inertial platforms subjected to random sway motion. A seventh-order Kalman filter has been designed for estimating the platform misalignments and sway motion. Using the linear quadratic optimal regulator techniques, feedback controller gains have been designed to drive the initial misalignments to a small value. A reconfiguration of the filter controller scheme has been proposed and verified by Monte Carlo simulation for improving the speed of alignment without changing the alignment accuracy.

Vathsal, S.↗

IR-dust observations of Comet Tempel 2 with CRAF VIMS

Measurement strategies are now being planned for using the Visual and Infrared Mapping Spectrometer (VIMS) to observe the asteroid Hestia, and the nucleus, and the gas and dust in the coma of comet P/Tempel 2 as part of the Comet Rendezvous Asteroid Flyby (CRAF) mission. The spectral range of VIMS will cover wavelengths from 0.35 to 5.2 micrometers, with a spectral resolution of 11 nm from 0.35 to 2.4 micrometers and of 22 nm from 2.4 to 5.2 micrometers. The instantaneous field of view (IFOV) provided by the foreoptics is 0.5 milliradians, and the current design of the instrument provides for a scanning secondary mirror which will scan a swath of length 72 IFOVs. The CRAF high resolution scan platform motion will permit slewing VIMS in a direction perpendicular to the swath. This enables the building of a two dimensional image in any or all wavelength channels. Important measurements of the dust coma will include the onset of early coma activity, the mapping of gas and dust jets and correlations with active nucleus areas, observations of the dust coma from various scattering phase angles, coverage of the low wavelength portion of the thermal radiation, and the 3.4 micrometer hydrocarbon emission. A description of the VIMS instrument is presented.

Combi, Michael R.↗

HERMIES-3: A step toward autonomous mobility, manipulation, and perception

HERMIES-III is an autonomous robot comprised of a seven degree-of-freedom (DOF) manipulator designed for human scale tasks, a laser range finder, a sonar array, an omni-directional wheel-driven chassis, multiple cameras, and a dual computer system containing a 16-node hypercube expandable to 128 nodes. The current experimental program involves performance of human-scale tasks (e.g., valve manipulation, use of tools), integration of a dexterous manipulator and platform motion in geometrically complex environments, and effective use of multiple cooperating robots (HERMIES-IIB and HERMIES-III). The environment in which the robots operate has been designed to include multiple valves, pipes, meters, obstacles on the floor, valves occluded from view, and multiple paths of differing navigation complexity. The ongoing research program supports the development of autonomous capability for HERMIES-IIB and III to perform complex navigation and manipulation under time constraints, while dealing with imprecise sensory information.

Weisbin, C. R.↗

Piloted Simulation Investigation of a Supersonic Transport Configuration (LaRC.4)

This report contains a description of the test facilities and software utilized during a joint NASA/aerospace industry study of improved control laws and desired inceptor characteristics for a candidate supersonic transport air-craft design. Details concerning the characteristics of the simulation cockpit, image generator and display systems, and motion platform are described. Depictions of the various display formats are included. The test schedule, session log, and flight cards describing the maneuvers performed is included. A brief summary of high-lights of the study is given. Modifications made to the industry-provided simulation model are described. This report is intended to serve as a reference document for industry researchers.

Jackson, E. Bruce↗

Improving Scientific Capabilities in Space in the 21st Century: The NASA New Millennium Program

NASA's New Millennium Program (NMP) has been chartered to identify and validate in space emerging, revolutionary technologies that will enable less costly, more capable future science missions. The program utilizes a unique blend of science guidance and industry partnering to ferret out technology solutions to enable science capabilities in space which are presently technically infeasible, or unaffordable. Those technologies which present an unacceptably high risk to future science missions (whether small PI-led or operational) are bundled into technology validation missions. These missions seek to validate the technologies in a manner consistent with their future uses, thus reducing the associated risk to the first user, and obtaining meaningful science data as well. The Space Readiness Coherent Lidar Experiment (SPARCLE) was approved as the second NMP Earth Observing mission (EO2) in October 1997, and assigned to Marshall Space Flight Center for implementation. Leading up to mission confirmation, NMP sponsored a community workshop in March 1996 to draft Level-1 requirements for a doppler wind lidar mission, as well as other space-based lidar missions (such as DIAL). Subsequently, a study group was formed and met twice to make recommendations on how to perform a comparison of coherent and direct detection wind lidars in space. These recommendations have guided the science validation plan for the SPARCLE mission, and will ensure that future users will be able to confidently assess the risk profile of future doppler wind missions utilizing EO2 technologies. The primary risks to be retired are: (1) Maintenance of optical alignments through launch and operations on orbit, and (2) Successful velocity estimation compensation for the Doppler shift due to the platform motion, and due to the earth's rotation. This includes the need to account for all sources of error associated with pointing control and knowledge. The validation objectives are: (1) Demonstrate measurement of tropospheric winds from space using a scanning coherent Doppler lidar technique that scales to meet future research (e.g. ESSP) and operational (e.g. NPOESS) mission requirements. Specifically, produce and validate LOS wind data with single shot accuracy of 1-2 m/s in regions of high signal-to-noise ratio (SNR), and low atmospheric wind turbulence and wind shear, (2) Collect the atmospheric and instrument performance data in various scanning modes necessary to validate and improve instrument performance models that will enable the definition of future missions with greater confidence. Such data include aerosol backscatter data over much of the globe, and high SNR data such as that from surface returns, and (3) Produce a set of raw instrument data with which advanced signal processing techniques can be developed. This objective will permit future missions to better understand how to extract wind information from low backscatter regions of the atmosphere.

Raymond, Carol A.↗

Replicating HAVE PIO on the NASA Ames VMS

This presentation discuss ground-based simulation, and flight-tests study (HAVE PIO). The purpose of this study is to determine if the amount of platform motion affects ability to replicate in-flight results.

Schroeder, Jeffery↗

Dynamic posture analysis of Spacelab-1 crew members

Dynamic posture testing was conducted on the science crew of the Spacelab-1 mission on a single axis linear motion platform. Tests took place in pre- and post-flight sessions lasting approximately 20 min each. The pre-flight tests were widely spaced over the several months prior to the mission while the post-flight tests were conducted over the first, second, fourth, and sixth days after landing. Two of the crew members were also tested on the day of landing. Consistent with previous postural testing conducted on flight crews, these crew members were able to complete simple postural tasks to an acceptable level even in the first few hours after landing. Our tests were designed to induce dynamic postural responses using a variety of stimuli and from these responses, evaluate subtle changes in the postural control system which had occurred over the duration of the flight. Periodic sampling post-flight allowed us to observe the time course of readaptation to terrestrial life. Our observations of hip and shoulder position, when subjected to careful analysis, indicated modification of the postural response from pre- to post-flight and that demonstrable adjustments in the dynamic control of their postural systems were taking place in the first few days after flight. For transient stimuli where the platform on which they were asked to stand quickly moved a few centimeters fore or aft then stopped, ballistic or open loop 'programs' would closely characterize the response. During these responses the desired target position was not always achieved and of equal importance not always properly corrected some 15 seconds after the platform ceased to move. The persistent observation was that the subjects had a much stronger dependence on visual stabilization post-flight than pre-flight. This was best illustrated by a slow or only partial recovery to an upward posture after a transient base-of-support movement with eyes open. Postural responses to persistent wideband pseudorandom base-of-support translation were modeled as time invarient linear systems arrived at by Kalman adaptive filter techniques. Derived model parameters such as damping factor and fundamental frequency of the closed loop system showed significant modification between pre- and post-flight. This phenomenon is best characterized by movement of the poles toward increasing stability. While pre-flight data tended to show shoulders and hips moving in phase with each other, post-flight data showed a more disjoint behavior.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Wavenumber Domain Focusing of Squinted SAR Data with a Curved Orbit Geometry

Synthetic Aperture Radar systems provide raw data that need focusing to achieve full-resolution imaging. Current SAR applications, including interferometry, require accurate, phase-preserving, and precisely co-registered coherent images over large ground swaths with the highest achievable resolution. In addition to these challenges, stripmap SAR data may be acquired with an off-broadside (squinted) geometry, either by design or through platform motion. The precise batch focusing of these large aperture and wide bandwidth data sets is known to require a 2D frequency processing approach. The standard wave domain focusing algorithm, however, is only exact for data acquired on a rectilinear trajectory. We investigate a generalization of the standard omega-k focusing formulation that allows curved data acquisition tracks. The new formulation can be used in conjunction with a known extension for conical, squinted imaging grids. The approximations necessary to allow the generalized geometry are analyzed to determine the range of applicability of the proposed algorithm. The theory is validated using data simulated with parameters similar to the UAVSAR L-band SAR system.

curved orbit geometry↗

Development of an Integrated Countermeasure Device for Long Duration Space Flight and Exploration Missions

Musculoskeletal, cardiovascular, and sensorimotor deconditioning have been observed consistently in astronauts and cosmonauts following long-duration spaceflight. Studies in bed rest, a spaceflight analog, have shown that high intensity resistive or aerobic exercise attenuates or prevents musculoskeletal and cardiovascular deconditioning, respectively, but complete protection has not been achieved during spaceflight. Exercise countermeasure hardware used during earlier International Space Station (ISS) missions included a cycle ergometer, a treadmill, and the interim resistive exercise device (iRED). Effectiveness of the countermeasures may have been diminished by limited loading characteristics of the iRED as well as speed restrictions and subject harness discomfort during treadmill exercise. The Advanced Resistive Exercise Device (ARED) and the second generation treadmill were designed to address many of the limitations of their predecessors, and anecdotal reports from ISS crews suggest that their conditioning is better preserved since the new hardware was delivered in 2009. However, several countermeasure devices to protect different physiologic systems will not be practical during exploration missions when the available volume and mass will be severely restricted. The combined countermeasure device (CCD) integrates a suite of hardware into one device intended to prevent spaceflight-induced musculoskeletal, cardiovascular, and sensorimotor deconditioning. The CCD includes pneumatic loading devices with attached cables for resistive exercise, a cycle for aerobic exercise, and a 6 degree of freedom motion platform for balance training. In a proof of concept test, ambulatory untrained subjects increased muscle strength (58%) as well as aerobic capacity (26%) after 12-weeks of exercise training with the CCD (without balance training), improvements comparable to those observed with traditional exercise training. These preliminary results suggest that this CCD can concurrently improve musculoskeletal and cardiovascular conditioning in ambulatory subjects, but further work is required to validate its use as countermeasure to spaceflight-induced deconditioning.

Lee, S. M. C.↗

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.↗

6DOF Testing of the SLS Inertial Navigation Unit

The Navigation System on the NASA Space Launch System (SLS) Block 1 vehicle performs initial alignment of the Inertial Navigation System (INS) navigation frame through gyrocompass alignment (GCA). Because the navigation architecture for the SLS Block 1 vehicle is a purely inertial system, the accuracy of the achieved orbit relative to mission requirements is very sensitive to initial alignment accuracy. The assessment of this sensitivity and many others via simulation is a part of the SLS Model-Based Design and Model-Based Requirements approach. As a part of the aforementioned, 6DOF Monte Carlo simulation is used in large part to develop and demonstrate verification of program requirements. To facilitate this and the GN&C flight software design process, an SLS-Program-controlled Design Math Model (DMM) of the SLS INS was developed by the SLS Navigation Team. The SLS INS model implements all of the key functions of the hardware-namely, GCA, inertial navigation, and FDIR (Fault Detection, Isolation, and Recovery)-in support of SLS GN&C design requirements verification. Despite the strong sensitivity to initial alignment, GCA accuracy requirements were not verified by test due to program cost and schedule constraints. Instead, the system relies upon assessments performed using the SLS INS model. In order to verify SLS program requirements by analysis, the SLS INS model is verified and validated against flight hardware. In lieu of direct testing of GCA accuracy in support of requirement verification, the SLS Navigation Team proposed and conducted an engineering test to, among other things, validate the GCA performance and overall behavior of the SLS INS model through comparison with test data. This paper will detail dynamic hardware testing of the SLS INS, conducted by the SLS Navigation Team at Marshall Space Flight Center's 6DOF Table Facility, in support of GCA performance characterization and INS model validation. A 6-DOF motion platform was used to produce 6DOF pad twist and sway dynamics while a simulated SLS flight computer communicated with the INS. Tests conducted include an evaluation of GCA algorithm robustness to increasingly dynamic pad environments, an examination of GCA algorithm stability and accuracy over long durations, and a long-duration static test to gather enough data for Allan Variance analysis. Test setup, execution, and data analysis will be discussed, including analysis performed in support of SLS INS model validation.

Geohagan, Kevin↗

6DOF Testing of the SLS Inertial Navigation Unit

The Navigation System on the NASA Space Launch System (SLS) Block 1 vehicle performs initial alignment of the Inertial Navigation System (INS) navigation frame through gyrocompass alignment (GCA). In lieu of direct testing of GCA accuracy in support of requirement verification, the SLS Navigation Team proposed and conducted an engineering test to, among other things, validate the GCA performance and overall behavior of the SLS INS model through comparison with test data. This paper will detail dynamic hardware testing of the SLS INS, conducted by the SLS Navigation Team at Marshall Space Flight Center's 6DOF Table Facility, in support of GCA performance characterization and INS model validation. A 6-DOF motion platform was used to produce 6DOF pad twist and sway dynamics while a simulated SLS flight computer communicated with the INS. Tests conducted include an evaluation of GCA algorithm robustness to increasingly dynamic pad environments, an examination of GCA algorithm stability and accuracy over long durations, and a long-duration static test to gather enough data for Allan Variance analysis. Test setup, execution, and data analysis will be discussed, including analysis performed in support of SLS INS model validation.

Geohagan, Kevin W.↗

Assessments of Physiology and Cognition in Hybrid-Reality Environments (APACHE) – A VR “Sandbox” for Planetary Spacewalk Research

NASA is planning to return to the Moon in the mid-2020s as a steppingstone to Mars missions in the 2030s. Spacewalks, or extravehicular activities (EVAs), performed on the Moon and Mars will differ in a variety of ways from those that have been performed in decades past. NASA has identified multiple risks to human health and performance associated with a crewed mission to Mars, especially those associated with exploration EVAs which are expected to be a primary mission activity. Crew may be expected to conduct up to 24 hours of EVA per person per week, where the likelihood of injury and/or mental mistakes are increased compared to ground-based training or current microgravity EVAs and the consequences of which can be catastrophic. Current test environments for exploration EVA research and technology development are large, costly facilities that are limited in their availability or capabilities. Spacesuit testing in a reduced gravity environment such as NASA’s Neutral Buoyancy Laboratory, while a good representation of the crew’s physical workload during exploration EVAs, typically has small datasets and is difficult to integrate physiological sensors or other types of crew performance measures. Meanwhile, scientific field-based testing such as NASA’s Desert Research and Technology Studies offers an operationally relevant environment for exploration EVAs, particularly for cognitive workload, but is also limited by small datasets, lack of a pressurized spacesuit, and obtrusive measures. The limitations of current analogs for exploration EVAs identify a need for a new test environment that can approximate both the physical and cognitive demands associated with exploration EVAs to enable rapid, controlled, and repeatable evaluations of human health and performance risks of exploration missions. In response, the Human Physiology, Performance, Protection, and Operations Laboratory (H-3PO) at NASA Johnson Space Center has developed a hybrid reality exploration EVA analog named the Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE)[ to address these limitations using a combination of virtual, physical, and hybrid reality techniques. The APACHE facility resides at NASA Johnson Space Center and serves as a large “sandbox” for EVA research and simulation. At its center is a roughly 15x20ft space surrounded by a 14” tall sandbox partially filled with lunar regolith simulant to emulate the physical feeling of walking on a planetary surface and to allow for simulated geology operations. Nearby, a curved passive treadmill (Skillmill Connect, Technogym, Fairfield, NJ) and an omnidirectional treadmill (Infinadeck, Infinadeck, Rocklin, CA) are included to enable exploration of these large virtual environments while also imposing the physical demands, representative timelines, and cognitive burdens required to navigate and traverse these distances during exploration EVA. A 6DOF motion platform is used to simulate rover operations and supports various human performance evaluations and associated risks. Lastly, APACHE can support two extravehicular (EV) crewmembers working in tandem. A computer workstation is located nearby and also supports an intravehicular (IV) crewmember as part of a full mission simulation. The IV crewmember has direct video and audio communication with the EV crew in VR to provide operational and procedural support.

Human Performance↗