Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plastic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The response of a scintillation counter below an emulsion chamber to heavy nucleus interactions in the chamber

In 1982 a hybrid electronic counter-emulsion chamber experiment was flown on a balloon to study heavy nucleus interactions in the 20 to approximately 100 GeV/AMU energy range. A gas Cerenkov counter, two solid Cerenkov counters, and a proportional counter hodoscope gave the primary energy, the primary charge and the trajectory of the particles, respectively. Using the trajectory information cosmic ray nuclei of Z 10 were found reliably and efficiently, and interaction characteristics of the Fe group nuclei were measured in the chamber. A plastic scintillator below the emulsion chamber responded to showers resulting from interactions in the chamber and to noninteracting nuclei. Data on the response of the counter have been compared with simulations of hadronic-electromagnetic cascades to derive the average neutral energy fraction released by the heavy interactions, and to predict the performance of this kind of counter at higher energies. For the interacting events of highest produced particles multiplicity comparison between various simulations and the shower counter signal have been made.

Burnett, T. H.↗

An experiment to study the nuclear component of primary cosmic rays

An apparatus has been designed and is being fabricated to study the charge composition, fluxes, and energy spectra of light nuclei in the energy region from 1 GeV to 100 GeV. The apparatus essentially consists of an array of a large number of particle detectors operated in coincidence and serving as a charged particle telescope. A mosaic silicon semiconductor detector, a plastic scintillation counter and a lucite Cerenkov detector are used to measure the charges of the incident nuclei. Two one-inch thick CsI detectors are used to study low energy particles. An ionization spectrometer is utilized to measure primary energies in the 1 to 100 GeV energy interval. A gas Cerenkov counter is being designed to distinguish between electrons and protons. It is planned to calibrate the apparatus at an accelerator using particles of known energy.

Paul, J. M.↗

Measurement of the nuclear electromagnetic cascade development in glass at energies above 200 GeV

The longitudinal development of nuclear-electromagnetic cascades with energies greater than 200 GeV was measured in a low-Z (glass) absorber. This was done in the course of operating an ionization spectrometer at mountain altitude in an experiment to study the properties of gamma rays emitted from individual interactions at energies around 10,000 GeV. The ionization produced by a cascade is sampled by 20 sheets of plastic scintillator spaced uniformly in depth every 2.2 radiation lengths. Adjacent pairs of scintillators are viewed by photomultipliers which measure the mean ionization produced by an individual cascade in 10 layers each 1.1 interaction length (4.4 radiation lengths) thick. The longitudinal development of the cascades was measured for about 250 cascades having energies ranging from 200 GeV to 2500 GeV. The observations are compared with the predictions of calculations made for this specific spectrometer using a three-dimensional Monte Carlo model of the nuclear-electromagnetic cascade.

Gillespie, C. R.↗

Comparison of the energy response of an ionization spectrometer for pions and protons

An ionization spectrometer consisting of a sandwich of iron absorbers and plastic scintillation counters was used to measure the energy of pions and protons in the interval 10 to 1000 GeV. For the limited energy interval of 10 to 40 GeV, pions and protons were identified by an air cerenkov counter. Interactions in carbon were studied in a multiplate cloud chamber placed between the cerenkov counter and the spectrometer. Knowledge of these interactions were used in conjunction with a Monte Carlo simulation of the cascade process to study differences in the response of the spectrometer to pions and protons.

Jones, W. V.↗

Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗

The interaction lengths of energetic pions and protons in iron

The interaction lengths of pions and protons in iron have been measured using an ionization spectrometer composed of alternating layers of iron and plastic scintillator. These measurements cover an energy range from 9.3 to 18 GeV. The interaction lengths were determined by accurate statistical analyses of the experimental data using the maximum likelihood method. The dependence of the interaction length on the parameters used to define an interaction was studied, and the results reported employ parameters chosen to minimize the percentage uncertainty in the interaction length. The mean interaction length of pions was found to be approximately 20% greater than that of protons.

Crannell, H.↗

Differential energy spectra of low energy (less than 8.5 MeV per nucleon) heavy cosmic rays during solar quiet times

Explorer 47 satellite observations of carbon, oxygen, and heavier nuclei differential energy spectra below 8.5 MeV/nucleon are presented for solar quiet time periods. A dE/dx vs E method for particle identification and energy determination was used. The instrumentation telescope included an isobutane proportional counter, a surface barrier Si detector, and a cylindrical plastic scintillator anticoincidence shield. The observations were performed outside the bow-shock and in the ecliptic plane. Results show an anisotropy of about 25% at 22 degrees west of the sun with a C/O ratio of 0.5 supporting a solar origin. The low energy portions of the C and O spectra have steep negative slopes, and the corresponding power law is given. Peculiarities in the O spectrum are discussed.

Hovestadt, D.↗

Observations of the ratio of low-energy cosmic-ray positrons and electrons during solar quiet times

Simultaneous observations of the quiet-time interplanetary positron and electron spectra between 0.16 and 1.6 MeV are reported. The measurements were made in selected time intervals between October 1, 1972 and February 1, 1973 with the Caltech Electron/Isotope Spectrometer on the IMP-7 satellite. The detector system consists of a stack of 11 silicon surface-barrier detectors surrounded by a plastic scintillator anti-coincidence cup. The method of e+ identification and possible background effects are discussed and upper limits to the 0.16 to 1.6 MeV quiet-time positron flux are reported. During this period positrons amounted to less than 20% of the total 0.16 to 1.6 MeV electron flux.

Hurford, G. J.↗

Observations of low energy gamma-ray bursts with SAS-2

The present paper reports on the low-energy gamma-ray bursts observed by the plastic scintillator anticoincidence dome of the Small Astronomy Satellite-2 (SAS-2) gamma-ray telescope. SAS-2 detected two events observed by other satellites and discovered one which was subsequently confirmed by other satellite observations. Two events seen by other satellites were not detected by SAS-2, probably due to earth occultation. The event detection threshold for SAS-2 was almost two orders of magnitude lower than that of the Vela satellites.

Oegelman, H.↗

A balloon-borne ionization spectrometer with very large aperture for the detection of high energy cosmic rays

A balloon experiment which was used to determine the chemical composition of very high-energy cosmic rays up to and beyond 100 GeV/nucleon is described. The detector had a geometric factor of 1 sq m sr and a total weight on the balloon of 2100 kg. The apparatus consisted of an ionization spectrometer, spark chambers, and plastic scintillation and Cherenkov counters. It was calibrated at CERN up to 24 GeV/c protons and at DESY up to 7 GeV/c electrons. In October 1972 it was flown successfully on a stratospheric balloon.

Atallah, K.↗

Narrow spikes in the selective precipitation of relativistic electrons in mid-latitudes

Relativistic electron precipitation spikes were observed in the quasi-trapped population at midlatitudes by an array of electron detectors aboard the low-altitude polar-orbiting satellite 1972-076B. The fluxes of electrons of energies not less than 4 MeV may undergo pronounced enhancements, while the intensities of electrons in the few hundred keV range may not be significantly affected. Energy spectra and pitch angle distributions were measured over the energy range 160 keV to 2.4 MeV with a combination of three spectrometers. Fluxes of energetic electrons (greater than 4 MeV) were measured with high sensitivity in each of two large plastic scintillator anticoincidence counters surrounding a germanium spectrometer.

Imhof, W. L.↗

Some methods in high energy cosmic ray measurement

Problems concerning ion chamber and emulsion detection techniques for high energy cosmic ray measurement are investigated. The calculation of the average energy actually deposited in an ion chamber by an ultra-high energy particle of large mass and charge is examined. A calculational scheme already applied successfully to particles of charge 1 is extended. Also, the calibration of a plate of plastic scintillator for measurement of the position of a cosmic ray shower passing through it is discussed. The method of calibration is to inject pulses of flight at known positions on the plate and record the responses of photomultiplier tubes at the corner of the plate.

Shand, J. B., Jr.↗

The high energy cosmic ray detector for Spacelab II

A large cosmic ray detector to be flown on Spacelab II is presently under construction at the University of Chicago. The instrument, with a geometric factor of 5 sq m-ster, is designed to measure the elemental composition and the energy spectra of individual cosmic ray nuclei (Li to Fe) from 50 GeV/nucleon to several TeV/nucleon. Plastic scintillators are used for charge determination, and gas Cerenkov and transition radiation detectors for energy measurements. The instrument and its functions are described, and several test results that are important for an optimum design are discussed.

Lamport, J. E.↗