Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plasma detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Activation of the CaR-CSE/H2S pathway confers cardioprotection against ischemia-reperfusion injury

Ischemia-reperfusion (I/R) injury is a multifactorial process triggered when an organ is subjected to transiently reduced blood supply. The result is a cascade of pathological complications and organ damage due to the production of reactive oxygen species following reperfusion. The present study aims to evaluate the role of activated calcium-sensing receptor (CaR)-cystathionine γ-lyase (CSE)/hydrogen sulfide (H2S) pathway in I/R injury. Firstly, an I/R rat model with CSE knockout was constructed. Transthoracic echocardiography, TTC and HE staining were performed to determine the cardiac function of rats following I/R Injury, followed by TUNEL staining observation on apoptosis. Besides, with the attempt to better elucidate how CaR-CSE/H2S affects I/R, in-vitro culture of human coronary artery endothelial cells (HCAECs) was conducted with gadolinium chloride (GdCl3, a CaR agonist), H{sub 2}O{sub 2}, siRNA against CSE (siCSE), or W7 (a CaM inhibitor). The interaction between CSE and CaM was subsequently detected. Plasma oxidative stress indexes, H2S and CSE, and apoptosis-related proteins were all analyzed following cell apoptosis. We found that H2S elevation led to the improvement whereas CSE knockdown decreased cardiac function in rats with I/R injury. Moreover, oxidative stress injury in I/R rats with CSE knockout was aggravated, while the increased expression of H2S and CSE in the aortic tissues resulted in alleviated the oxidative stress injury. Moreover, increased H2S and CSE levels were found to inhibit cell apoptotic ability in the aortic tissues after I/R injury, thus attenuating oxidative stress injury, accompanied by inhibited expression of apoptosis-related proteins. In HCAECs following oxidative stress treatment, siCSE and CaM inhibitor were observed to reverse the protection of CaR agonist. Coimmunoprecipitation assay revealed the interaction between CSE and CaM. Taken together, all above-mentioned data provides evidence that activation of the CaR-CSE/H2S pathway may confer a potent protective effect in cardiac I/R injury.

60 APPLIED LIFE SCIENCES↗

Voyager at Uranus: 1986

The voyager 2 spacecraft begins its initial observations of Uranus November 4, 1985, and makes its final observation February 25, 1996. The data from the infrared interfermometer spectrometer, photopolarimeters, plasma wave, plasma detecter, and ultraviolet spectrometer will be processed to add a large block of infermation to the small amount already known. The trajectory of Voyager 2 is also discussed.

Source record↗

The Spacelab 2 mission - An overview

A summary is presented of the results of experiments on the Spacelab 2 mission, which was flown on the Shuttle Orbiter between July 29 and August 6, 1985. The background and flight of the mission and the payload configuration are examined. The experiments include the Ejectable Plasma Diagnostics Package, Vehicle Charging and Potential Experiment, and plasma detection experiments. Life science experiments include studies of the effects of spaceflight on the growth of plant tissues and perturbations of bone and calcium homeostasis in flight crew members. Solar studies include the Solar UV Spectral Irradiance Monitor, the Coronal Helium Abundance Spacelab Experiment, the High Resolution Telescope and Spectrograph, the Solar Magnetic and Velocity Field Measurement System, and the Solar Optical Universal Polarimeter. Additional experiments include observations with a small He-cooler IR telescope, Hard X-ray imaging of galaxy clusters and extended X-ray sources, the composition and energy spectra of cosmic ray nuclei, and the properties of superfluid He in zero gravity.

Urban, Eugene W.↗

The orbital debris detector consortium: Suppliers of instruments for in-situ measurements of small-particles in the space environment

Industry and university participants have joined together to form the IMPA:Ct consortium (In-situ Monitors of the Particulate Ambient: Circumterrestrial) which offers a broad range of flight qualified instruments for monitoring the small particle (0.1 micron to 10 cm) environment in space. Instruments are available in 12 months or less at costs ranging from 0.5 to 1.5 million dollars (US) for the total program. Detector technologies represented by these groups are: impact-induced capacitor-discharge (MOS, metal-oxide-silicon), cratering or penetration of electroactive thin film (polyvinylidene fluoride (PVDF)), impact-plasma detection, acoustic detection, CCD tracking of optical scatter of sunlight, and photodiode detection of optical scatter of laser light. The operational characteristics, general spacecraft interface and resource requirements (mass/power/telemetry), cost and delivery schedules, and points of contact for seven different instruments are presented.

Simon, C. G.↗

An investigation of mechanisms other than lightning to explain certain wideband plasma wave bursts detected in the Venusian nightside ionosphere

Several related topics are briefly discussed. Reviewed here is work on an investigation of plasma wave phenomena associated with the question of lightning on Venus. The work supported the contention that lightning is at least a candidate explanation for many of the 100 Hz-only Pioneer Venus orbital electric field detector (OEFD) signals. A review of the work on the investigation of mechanisms other than lightning to explain certain wideband plasma wave bursts detected in the Venusian nightside ionosphere is given. A summary is given of our analysis of data from 23 OEFD observing periods as well as a discussion of the properties of specifically multifrequency events. Our opportunity to work on this topic was not sufficient to draw any firm conclusions about the origins of the multifrequency bursts, but we call attention to what we consider to be several candidate sources. Also discussed are case studies to test for evidence of whistler mode propagation from subionospheric sources, results of a search for dispersive effects in the OEFD data, the results for a search for simultaneous 100 Hz and 730 Hz observations at altitudes below 150 km, changes with altitude in dispersive broadening effects in the time signatures of 100 Hz bursts, and a survey of activity at altitudes above 1000 km.

Carpenter, D. L.↗

Simultaneous in situ magnetospheric and ionospheric detection of detached plasmas

On January 19, 1972, in situ measurements by Explorer 45, orbiting in the magnetosphere near the equatorial plane, and ISIS 2, in a circular polar orbit at 1400 km, simultaneously detected patches of enhanced ionization outside the main body of the plasmasphere. The magnetospheric plasma region extended between (geomagnetic latitude) L values 3.4-4.8 and the ionospheric electron density enhancement extended between L values 3.6-4.4. The two plasma features were detected near 22 hours magnetic local time (MLT). Based on a number of observations, it is inferred that the plasma density enhancement persisted for more than 5 hours and extended over at least 2 hours in MLT near L = 5. These results provide experimental evidence that some detached magnetospheric plasma regions are signatures of a flux tube containing enhanced ionization throughout a volume extending from the topside ionosphere out to the equator.

Miller, N. J.↗

Plasma Biomarkers for Detecting Hodgkin's Lymphoma in HIV Patients

The lifespan of AIDS patients has increased as a result of aggressive antiretroviral therapy, and the incidences of the AIDS-defining cancers, Hodgkin's lymphoma and Kaposi sarcoma, are declining, Still, the increased longevity of AIDS patients is now associated with increased incidence of other cancers, including Hodgkin's lymphoma (HL). In order to determine if we could identify biomarkers for the early detection of HL, we undertook an accurate mass and elution time tag proteomics analysis of individual plasma samples from AIDS patients without HL (n=14) and with HL (n=22). This analysis identified 33 proteins, included C-reactive protein and three serum amyloid proteins, that were statistically (p<0.05) altered by at least 1.5-fold between the two groups. At least three of these proteins have previously been reported to be altered in the blood of HL patients. Ingenuity Pathway Analysis software identified 'inflammatory response' and 'cancer' as the top two, biological functions commonly associated with these proteins. The clear association of these proteins with cancer and inflammation suggests that they are truly associated with HL and that they would be useful in the detection of this disease.

59 BASIC BIOLOGICAL SCIENCES↗

Theory of a laser-plasma method for detecting terahertz radiation

A theory is developed for calculating the spectrum and the shape of a terahertz wave packet from the temporal profile of the energy of the second harmonic of the laser field generated during nonlinear interaction of laser and terahertz pulses in an optical-breakdown plasma. The spectral and temporal characteristics of the second-harmonic envelope and a terahertz pulse are shown to coincide only for short laser pulses. For long laser pulses, the second-harmonic spectral line shifts to the red and its temporal profile is determined by the time integral of the electric field of terahertz radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Voyager 2 plasma wave observations at Saturn

The first inbound Voyager 2 crossing of Saturn's bow shock (at 31.7 Saturn radii near local noon) and the last outbound crossing (at 87.4 Saturn radii near local dawn) had similar plasma wave signatures. However, many other aspects of the plasma wave measurements differed considerably during the inbound and outbound passes, suggesting the presence of effects associated with significant north-south or noon-dawn asymmetries, or temporal variations. Within Saturn's magnetosphere, the plasma wave instrument detected electron plasma oscillations, upper hybrid resonance emissions, half-gyrofrequency harmonics, hiss and chorus, narrowband electromagnetic emissions and broadband Saturn radio noise, and noise bursts with characteristics of static. At the ring plane crossing, the plasma wave instrument also detected a large number of intense impulses that were interpreted in terms of ring particle impacts on Voyager 2.

Scarf, F. L.↗

ContourNet: Salient Local Contour Identification for Blob Detection in Fusion Plasma Simulation Data

We present ContourNet, a deep learning approach to identify salient local isocontours as blobs in large-scale 5D gyrokinetic tokamak simulation data. Blobs-regions of high turbulence that run along the edge wall down toward the diverter and can damage the tokamak-are non-well-defined features but have been empirically localized by isocontours in 2D normalized fluctuating density fields. The key of our study is to train ContourNet to follow the empirical rules to detect blobs over the time-varying simulation data. The architecture of ContourNet is a convolutional neural segmentation network: the inputs are the density field and a rasterized isocontour; the output is a set of isocontour encircling blobs. At the training stage, we feed the network with manually identified isocontours and propagated labels. At the inference stage, we extract isocontours from the segmented blob regions. Results show that our approach can achieve both high accuracy and performance, which enables scientists to understand the blob dynamics influencing the confinement of the plasma.

Blob detection↗

Plasma and radiation detection via fiber interferometry

Photonic Doppler velocimetry tracks motion during high-speed, single-event experiments using telecommunication fiber components. The same technology can be applied in situations where there is no actual motion, but rather a change in the optical path length. Migration of plasma into vacuum alters the refractive index near a fiber probe, while intense radiation modifies the refractive index of the fiber itself. Lastly, these changes can diagnose extreme environments in a flexible, time-resolved manner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COMPARISON OF HINODE/XRT AND RHESSI DETECTION OF HOT PLASMA IN THE NON-FLARING SOLAR CORONA

We compare observations of the non-flaring solar corona made simultaneously with Hinode/XRT and RHESSI. The analyzed corona is dominated by a single active region on 2006 November 12. The comparison is made on emission measures. We derive emission measure distributions versus temperature of the entire active region from multifilter XRT data. We check the compatibility with the total emission measure values estimated from the flux measured with RHESSI if the emission comes from isothermal plasma. We find that RHESSI and XRT data analyses consistently point to the presence of a minor emission measure component peaking at log T approx 6.8-6.9. The discrepancy between XRT and RHESSI results is within a factor of a few and indicates an acceptable level of cross-consistency.

79 ASTRONOMY AND ASTROPHYSICS↗

Pioneer 10/11 data analysis of the plasma analyzer experiment

The Pioneer 10 plasma analyzer detected the 10 plasma torus. Evidence was found of corotating ions which appear to be primarily S (++) and O (++) in the Pioneer 10 plasma data as the spacecraft moved inward from 6.9 to 5.4 R sub J. The Pioneer plasma analyzer was effective in obtaining information on the heavy ion populations in the Jovian magnetosphere. Interplanetary solar wind plasma shocks can trap energetic particles (cosmic rays) for weeks and out to distances of 17 AU. Energetic particles (o.5 MeV to 20 MeV) were confined between two plasma shocks from solar flares as the shocks propagated outward in the solar system.

Intriligator, D. S.↗

AC compensation of 3D magnetic diagnostic signals in DIII-D and National Spherical Torus Experiment-Upgrade (NSTX-U) for real-time application

A time domain algorithm has been developed to remove the vacuum pickup generated by both coil current (DC) and induced vessel current (AC) in real time from three dimensional (3D) magnetic diagnostic signals in the National Spherical Torus Experiment-Upgrade (NSTX-U) and DIII-D tokamaks. The possibility of detecting 3D plasma perturbations in real time is essential in modern and future tokamaks to avoid and control MHD instabilities. The presence of vacuum field pickup, due to toroidally asymmetric (3D) coils or to misalignment between sensors and axisymmetric (2D) coils, pollutes the measured plasma 3D field, making the detection of the magnetic field produced by the plasma challenging. Although the DC coupling between coils and sensors can be easily calculated and removed, the AC part is more difficult. Here, an algorithm based on a layered low-pass filter approach for the AC compensation and its application for DIII-D and NSTX-U data is presented, showing that this method reduces the vacuum pickup to the noise level. Comparison of plasma response measurements with and without vacuum compensation shows that accurate mode locking detection and plasma response identification require precise AC and DC compensations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗