Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Planning software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

SU-F-J-98: Improvement and Evaluation Of Deformation Image Registration On Parotid Glands During Radiation Therapy for Nasopharyngeal Cancer

Purpose: To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions. Two kinds of contours for parotid glands on daily MVCTs were obtained by populating these contours from planning CTs to the daily CTs via rigid-body registration with or without the rotation shifts using the in-house tools and the Adaptive plan software (Adaptive Plan, TomoTherapy), and were edited manually if necessary. The diffeomorphic Demons algorithm developed in the in-house tool was used to propagate the parotid structures from the daily CTs to planning CTs. The differences of the mapped parotid contours in two methods were evaluated using Dice similarity index (DSI). Two-tailed t-test analysis was carried out to compare the DSI changes during the course of RT. Results: For 10 patient plans, the accuracy of deformation image registration (DIR) with the rotation shift was obviously better than those without the rotation shift. The Dice scores of the ipsi- and contra-lateral parotids for with and without the rotation shifts were found to be correlated with each other [0.904±0.031 vs 0.919±0.030 (p<0.001); 0.900±0.031 vs 0.910±0.032 (p<0.001)]. The Dice scores for the parotids have shown the reduction with the changes of parotid volumes during RT. The DSI values between the first and last fraction were 0.932±0.020 vs 0.899±0.030 in 10 patient plans. Conclusion: DIR was successfully improved using the strategic innovation for ART. And the decrease of DIR accuracy has also been found during the delivery of fractionated radiotherapy. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225).

60 APPLIED LIFE SCIENCES↗

SU-F-J-145: MRI-Guided Interventional Boost Radiotherapy for Rectal Cancer: Investigating the Feasibility of Adapting the Anatomy

Purpose: The recent development of an MRI-linac allows adaptation of treatments to the anatomy of the moment. This anatomy, in turn, could be altered into a more favorable situation for radiotherapy purposes. The purpose of this study is to investigate the potential dosimetric benefits of manipulating rectal anatomy in MRI-guided interventional external-beam radiotherapy for rectal cancer. Methods: For this retrospective analysis, four patients (1M/3F) diagnosed with rectal cancer were included. These underwent MR-imaging using sonography transmission gel as endorectal contrast at time of diagnosis and standard, non-contrast, MR-imaging prior to radiotherapy planning. In the contrast scan, the rectum is inflated by the inserted contrast gel, thereby potentially increasing the distance between tumor and the organs-at-risk (OAR). Both anatomies were delineated and 7- beam IMRT-plans were calculated for both situations (RT-standard and RT-inflated), using in-house developed treatment planning software. Each plan was aimed to deliver 15Gy to the planning target volume (PTV; tumor+3mm margin) with a D99>95% and Dmax<120% of the planned dose. The D2cc dose to the OAR were then compared for both situations. Results: At equal (or better) target coverage, we found a mean reduction in D2cc of 4.1Gy/237% [range 2.6Gy–6.3Gy/70%–621%] for the bladder and of 2.0Gy/145% [range −0.7Gy–7.9Gy/−73%–442%] for the small-bowel, for the RT-inflated compared to the RT-standard plans. For the three female patients, a reduction in D2cc of 5.2Gy/191% [range 3.2Gy–9.2Gy/44%–475%] for the gynecological organs was found. We found all D2cc doses to be better for the RT-inflated plans, except for one patient for whom the bladder D2cc dose was slightly increased. Conclusion: Reduction of OAR dose by manipulation of anatomy is feasible. Inflation of the rectum results in more distance between OAR and PTV. This leads to a substantial reduction in dose to OAR at equal or better target coverage.

60 APPLIED LIFE SCIENCES↗

Flashline Mars Arctic Research Station (FMARS) 2009 Expedition Crew Perspectives

The Flashline Mars Arctic Research Station (FMARS), located on the rim of the Haughton Crater on Devon Island in the Canadian Arctic, is a simulated Mars habitat that provides operational constraints similar to those which will be faced by future human explorers on Mars. In July 2009, a six-member crew inhabited the isolated habitation module and conducted the twelfth FMARS mission. The crew members conducted frequent EVA operations wearing mock space suits to conduct field experiments under realistic Mars-like conditions. Their scientific campaign spanned a wide range of disciplines and included many firsts for Mars analog research. Among these are the first use of a Class IV medical laser during a Mars simulation, helping to relieve crew stress injuries during the mission. Also employed for the first time in a Mars simulation at FMARS, a UAV (Unmanned Aerial Vehicle) was used by the space-suited explorers, aiding them in their search for mineral resources. Sites identified by the UAV were then visited by geologists who conducted physical geologic sampling. For the first time, explorers in spacesuits deployed passive seismic equipment to monitor earthquake activity and characterize the planet's interior. They also conducted the first geophysical electromagnetic survey as analog Mars pioneers to search for water and characterize geological features under the surface. The crew collected hydrated minerals and attempted to produce drinkable water from the rocks. A variety of equipment was field tested as well, including new cameras that automatically geotag photos, data-recording GPS units, a tele-presence rover (operated from Florida), as well as MIT-developed mission planning software. As plans develop to return to the Moon and go on to Mars, analog facilities like FMARS can provide significant benefit to NASA and other organizations as they prepare for robust human space exploration. The authors will present preliminary results from these studies as well as their perspectives on topics including human factors, logistics, EVA operations, and the use of social media throughout the mission.

Cusack, Stacy↗

Advanced communications technology satellite high burst rate link evaluation terminal power control and rain fade software test plan, version 1.0

The Power Control and Rain Fade Software was developed at the NASA Lewis Research Center to support the Advanced Communications Technology Satellite High Burst Rate Link Evaluation Terminal (ACTS HBR-LET). The HBR-LET is an experimenters terminal to communicate with the ACTS for various experiments by government, university, and industry agencies. The Power Control and Rain Fade Software is one segment of the Control and Performance Monitor (C&PM) Software system of the HBR-LET. The Power Control and Rain Fade Software automatically controls the LET uplink power to compensate for signal fades. Besides power augmentation, the C&PM Software system is also responsible for instrument control during HBR-LET experiments, control of the Intermediate Frequency Switch Matrix on board the ACTS to yield a desired path through the spacecraft payload, and data display. The Power Control and Rain Fade Software User's Guide, Version 1.0 outlines the commands and procedures to install and operate the Power Control and Rain Fade Software. The Power Control and Rain Fade Software Maintenance Manual, Version 1.0 is a programmer's guide to the Power Control and Rain Fade Software. This manual details the current implementation of the software from a technical perspective. Included is an overview of the Power Control and Rain Fade Software, computer algorithms, format representations, and computer hardware configuration. The Power Control and Rain Fade Test Plan provides a step-by-step procedure to verify the operation of the software using a predetermined signal fade event. The Test Plan also provides a means to demonstrate the capability of the software.

Reinhart, Richard C.↗

VERAIO Software Management Plan

VERAIO is a set of utility codes used to provide a common set of input and outputs to the Virtual Environment for Reactor Applications (VERA). VERA is a collection of several different computer codes that all have a common input and output. This prevents the need to manage input and output from each individual code, allowing for ease of use and reducing errors associated with code operability. The VERAIO utilities include VERAIn, VERAView, and VERARun. Each of these utilities is described below. VERAIn is an input processor that reads an ASCII input file generated by users, parses the file, performs some error checking, and writes an XML file to be read by other VERA codes. The main purpose of VERAIn is to provide a common input to all of the VERA codes so users only need to learn one input. VERAIn is written in Perl and uses YAML configuration files to provide flexibility. VERAView is a graphical user interface (GUI) that reads a VERA HDF output file and allows users to visualize results. VERAView is written in Python. VERARun is a script that drives the VERA execution in a high performance computing (HPC) environment. Work performed at the code level supports the Quality Assurance Program Plan (QAPP) (VERA-QA-001), and VERA Software Quality Assurance Plan (VERA-QA-002).

97 MATHEMATICS AND COMPUTING↗

MPACT Software Management Plan (V.4.3)

The MPACT code solves a discretized form of the Boltzmann transport equation on a wide variety of geometries and is distributed with a multigroup neutron cross section library. MPACT provides an advanced geometrically resolved neutral-particle transport capability to solve the flux distribution throughout the entire problem geometry, and it can model the isotopic depletion, decay, and activation of materials. The flux solution in MPACT is provided using a 2D/1D synthesis method within the framework of the 3D coarse mesh finite difference (CMFD) method for which axial and radial correction factors are obtained from 2D method of characteristics (MOC) and 1D nodal expansion method (NEM), PN, or SN. Other key characteristics of the MPACT code include the subgroup method and the embedded self-shielding method (ESSM) for resonance treatment, depletion capability based on the ORIGEN exponential matrix method, and a simplified thermal-hydraulics method for temperature/fluid feedback. The sole purpose of the simplified feedback model is to provide a mechanism for testing during code development and to provide a limited capability for educational applications. Work performed at the code level supports the VERA-QA-001, quality assurance program plan (QAPP) and VERA-QA-002, VERA Software Quality Assurance Plan.

97 MATHEMATICS AND COMPUTING↗

Software Quality Assurance Plan: Argonne Reactor Code Software

The Argonne Reactor Code (ARC) software package consists of 13 primary and many secondary pieces of software that are connected through interface files. The ARC software suite supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Users' Guide to Vinci: Personal Computer Software for Planning Image-based Measurements in Wind Tunnels

Vinci is software that can be used to plan image-based measurements in wind tunnels. It allows the user to plan the placement of cameras and the choice of lenses well in advance of a test, thereby reducing the set-up time and cost when tunnel occupancy begins. It can also be used post-test to display data (pressure-sensitive paint, particle image velocimetry, model deformation) in context with the test article. Vinci is self-contained and runs on personal computers under Windows operating systems. No other software is required. Test articles are represented by CFD-like surface grids that may be read from an external file or created within the program as a combination of simple geometric shapes. The user controls the position and orientation of the test article through a Graphical User Interface (GUI) and may add many additional objects, including tunnel walls and windows, a wide variety of simple geometric shapes, mirrors, lamps, and laser sheets. The application computes simulated images from up to 40 cameras. Images are based on pinhole projection. Each camera is defined by the sensor size and the focal length of the lens. All camera parameters, including position and point angles, are controlled through the GUI. Simulated images are displayed in a window of the GUI and may be saved as bitmaps.

Users’ Guide, Image Planning, Wind Tunnels, Softwa↗

VERAIO Software Management Plan

VERAIO is a set of utility codes used to provide a common set of inputs and outputs to the Virtual Environment for Reactor Applications (VERA). VERA is a collection of several different computer codes that all have a common input and output. This prevents the need to manage input and output from each individual code, allowing for ease of use and reducing errors associated with code operability. The VERAIO utilities include VERAIn, VERAView, and VERARun. Each of these utilities is described below. VERAIn is an input processor that reads an ASCII input file generated by users, parses the file, performs some error checking, and writes an XML file to be read by other VERA codes. The main purpose of VERAIn is to provide a common input to all of the VERA codes, so users only need to learn one input. VERAIn is written in Perl and uses YAML configuration files to provide flexibility. VERAView is a graphical user interface (GUI) that reads a VERA hierarchical data format (HDF) output file and allows users to visualize results. VERAView is written in Python. VERARun is a script that drives the VERA execution in a high performance computing (HPC) environment. Work performed at the code level supports the quality assurance program plan (QAPP) (VERA-QA-001) and the VERA Software Quality Assurance Plan (VERA-QA-002).

97 MATHEMATICS AND COMPUTING↗

GCS plan for software aspects of certification

As part of the Guidance and Control Software (GCS) research project being sponsored by NASA to evaluate the failure processes of software, standard industry software development procedures are being employed. To ensure that these procedures are authentic, the guidelines outlined in the Radio Technical Commission for Aeronautics (RTCA/DO-178A document entitled, software considerations in airborne systems and equipment certification, were adopted. A major aspect of these guidelines is proper documentation. As such, this report, the plan for software aspects of certification, was produced in accordance with DO-178A. An overview is given of the GCS research project, including the goals of the project, project organization, and project schedules. It also specifies the plans for all aspects of the project which relate to the certification of the GCS implementations developed under a NASA contract. These plans include decisions made regarding the software specification, accuracy requirements, configuration management, implementation development and verification, and the development of the GCS simulator.

Shagnea, Anita M.↗

A product data network to enable faster, easier, and better planning of building envelopes

The building envelopes contributes significantly to the energy-efficiency of the building. Building performance simulation has made it possible to compare façade technologies regarding energy demand, daylighting, thermal and visual comfort in detail. Planners, such as architects and engineers, need experience to find product data with the right quality and level of detail, and to process the data to fit the calculation and the application. In the available time, planners can compare only a limited number of products, which means that better solutions could go unnoticed. This paper presents a new concept for making product data easily accessible for building façade planning. The concept consists of a network of databases for the efficient exchange and use of optical and calorimetric data of glazing units, shading devices, and combinations of both. The paper presents the research questions, an analysis of the current challenges, six design goals for the product data network and its implementation together with a discussion. Many product data sources can be connected to many planning software applications via the specified application programming interface. When planning software connects to the product data network, the planning of building envelopes can be much faster because planners do not need to spend so much time to search and process product data manually. The planning of building envelopes can also become much easier, especially for planners with limited experience. They do not need to understand all the details about which data fits which calculation if the software company implements this. The planning of building envelopes can become much more reliable when software companies validate their use of the product data network, because the current manual process is prone to errors. The planning of building envelopes can also improve because more products can be compared in the available time, allowing better solutions to be found.

Maurer, Christoph↗

Griffin Software Development Plan

Griffin is a MOOSE-based reactor physics application for advanced reactor multiphysics modeling and simulation. The application is developed in a consistent multiphysics environment with strong software quality assurance. Griffin inherited most of the capabilities of MAMMOTH/Rattlesnake and is adopting the capabilities from PROTEUS that are needed in the code. The toolset includes a variety of deterministic radiation transport solvers for fixed source, k-eigenvalue, ad-joint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. The code contains the cross-section preparation capabilities applicable to fast and thermal reactors, including TRISO-fueled reactors. Core management capabilities include core performance, fuel depletion and shuffling, equilibrium core calculation, pebble-bed reactor run-in and equilibrium core, molten-salt reactor delayed neutron precursor drift, and control rod and drum movement with cusping correction. This software development plan presents the current and future capabilities and features in Griffin for the design and analysis of non-light-water reactor systems in steady-state and transient conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Automating Software Productivity Planning: Lightweight Tools for Upgrading Team Practices

A lightweight iterative workflow, called Productivity and Sustainability Improvement Planning (PSIP) has been developed to assist software teams with employing good software engineering practices. Three PSIP tools automate practice summarization, self-assessment, and progress tracking to enhance team engagement around software process improvement: Reposcanner, RateYourProject (RYP) and Progress Tracking Cards (PTCs) respectively. Reposcanner is a data analysis tool. RYP is an interactive self-assessment tool that provides an easy-to-use entry point to the PSIP process. Once process improvements are identified, PTCs are created by teams to measure outcomes and progression toward their goals. We present an exemplifying case study with a software team where these tools have been put to use, along with a description of the tools, and future plans for further improvements.

Raybourn, Elaine↗

Software-Implementation Plan

Top-down implementation plan provides a methodology for solving problems in or aiding software engineering design.

Jacobson, G.↗

SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

60 APPLIED LIFE SCIENCES↗