Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Photon blockade in a Tavis-Cummings system

We observe blockade of microwave photons in a Tavis-Cummings system comprising a superconducting cavity and up to 𝑁 =3 transmon qubits. The effect is characterized with photon-number-resolving spectroscopy using an additional dispersively coupled transmon “witness” qubit to directly probe the cavity’s photon-number distribution. We first observe polariton formation with splitting proportional to $\sqrt{𝑁}$, confirming the Tavis-Cummings coupling, and subsequently obtain sub-Poissonian cavity photon statistics when the cavity is driven at polariton frequencies.

Marinelli, Brian [University of California, Berkel↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Maximum Energy of Particles Accelerated in Gamma-Ray Burst Afterglow Shocks

Particle acceleration in relativistic collisionless shocks remains an open problem in high-energy astrophysics. Particle-in-cell (PIC) simulations predict that electron acceleration in weakly magnetized shocks proceeds via small-angle scattering, leading to a maximum electron energy significantly below the Bohm limit. This upper bound on electron energy manifests observationally as a characteristic synchrotron cutoff, providing a direct probe of the underlying acceleration physics. Gamma-ray burst (GRB) afterglows offer an exceptional laboratory for testing these predictions. Here, we model the spectral evolution of GRB afterglows during the relativistic deceleration phase, incorporating PIC-motivated acceleration prescriptions and self-consistently computing synchrotron and synchrotron self-Compton emission. We find that low-energy bursts in low-density environments, typical of short GRBs, exhibit a pronounced synchrotron cutoff in the GeV band within minutes to hours after the trigger. Applying our framework to GRB 190114C and GRB 130427A, we find that current observations are insufficient to discriminate between PIC-motivated acceleration and the Bohm limit, primarily due to poor photon statistics in the Fermi-Large Area Telescope band. Nevertheless, future MeV–TeV afterglow observations can break model degeneracies and place substantially tighter constraints on the mechanisms responsible for particle acceleration in relativistic shocks. To this end, we simulate a fiducial nearby short GRB as a promising probe of the cutoff location, for which the two acceleration scenarios are cleanly distinguishable and the detection of such an event in the near future remains feasible.

Wu, Zhao-Feng [Purdue University, West Lafayette, ↗

Real-time correction of atmospherically degraded telescope images through image sharpening

We present a new technique for the correction of atmospheric distortion in telescope images. Most of this distortion arises from a random phase variation of the incoming light across the telescope aperture. This variation limits the resolving power of even large telescopes to about one arc second. If the sharpness of the images is defined in a suitable way, this sharpness is maximized only when the phase distortion of the incoming light is zero. We present computer simulations of a simple feedback system in which active optical elements, set to maximize the sharpness, correct most of the atmospheric distortion. Photon statistics set the limiting magnitude of the object for which a practical feedback system can work. Details in a sixth magnitude object smaller than 0.1 sec of arc should be resolvable. The system can be conveniently employed within existing telescopes.

Muller, R. A.↗

Astronomical monochromatic imaging as applied to the Io sodium cloud

Four types of instruments for recording monochromatic astronomical images are compared: filters; slitless spectrographs; multislit spectrographs; and interferometers. Each of these instruments has been used on the sodium emission cloud of Io, with varying degrees of success. Multislit spectrographs and interferometers encode the signal, and it can be extracted with a noise level close to that for photon statistics. This is not normally the case for filters and slitless spectrographs. On balance, it is found that a Mach-Zehnder interferometer provides the best system for imaging faint monochromatic signals on a brighter continuum background.

Murcray, F. J.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm-diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

OSO 8 observational limits to the acoustic coronal heating mechanism

An improved analysis of time-resolved line profiles of the C IV resonance line at 1548 A has been used to test the acoustic wave hypothesis of solar coronal heating. It is shown that the observed motions and brightness fluctuations are consistent with the existence of acoustic waves. Specific account is taken of the effect of photon statistics on the observed velocities, and a test is devised to determine whether the motions represent propagating or evanescent waves. It is found that on the average about as much energy is carried upward as downward such that the net acoustic flux density is statistically consistent with zero. The statistical uncertainty in this null result is three orders of magnitue lower than the flux level needed to heat the corona.

Bruner, E. C., Jr.↗

Optical studies of X-ray sources with the MASCOT - A charge-coupled device /CCD/-based astronomical instrument

The performance levels achieved by the MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes) on the 1.3-m telescope at the McGraw-Hill observatory in March 1981 are discussed along with preliminary data obtained in searches for optical counterparts to four 'empty-field' X-ray sources. In the W band (4000-7000 A), the MASCOT achieved a sky-limited sensitivity of +24.4 mag per sq arcsec in an 1800 s integration. The ability to flatten pictures to a level consistent with (sky + source) photon statistics and readout noise was demonstrated. For the four sources observed, an optical counterpart was established for one source (1413+13) based on positional coincidence (better than 1.8 arcsec), four possible candidates were detected in the error box of another source (1009?35) and upper sensitivity limits were established for optical counterparts in the error boxes for the other two sources (0920+39 and 0931-11).

Ricker, G. R.↗

Echelle spectroscopy with a charge-coupled device /CCD/

The recent availability of large format CCD's with high quantum efficiency makes it possible to achieve significant advances in high dispersion astronomical spectroscopy. An echelle CCD combination excels or equals other techniques presently available, and offers the advantage of complete spectral coverage of several thousand Angstroms in a single exposure. Attention is given to experiments which were conducted with a CCD camera head and an echelle spectrograph on a 4-meter telescope. It was found possible to achieve a signal-to-noise ratio of 150/1 on a 13th magnitude star at 6000 A in a two-hour exposure at 0.16 A/pixel, limited primarily by photon statistics. For fainter objects, readout noise is the limiting factor in precision. For 20 electron rms readout noise, an S/N = 15/1 at 18th magnitude is expected, all other things being equal.

York, D. G.↗

Time Series Photometry with a CCD Camera

Time series observations of a field in the cluster NGC 4755 with a CCD camera are used to show that differential photometry between stars on the CCD frame is limited in accuracy mostly by photon statistics, over a 5 magnitude range. Scintillation noise appears to be almost entirely suppressed. The maximum accuracy possible is limited by the storage capacity of the CCD to about 0.001 mag.

Walker, A. R.↗

Operational characteristics of Wedge and Strip image readout systems

Application of the Wedge and Strip readout system in microchannel plate detectors for the Extreme Ultraviolet Explorer and FAUST space astronomy programs is discussed. Anode designs with high resolution (greater than 600 x 600 pixels) in imaging and spectroscopy applications have been developed. Extension of these designs to larger formats (100 mm) with higher resolution (3000 x 3000 pixels) are considered. It is shown that the resolution and imaging are highly stable, and that the flat field performance is essentially limited by photon statistics. Very high speed event response has also been achieved with output pulses having durations of less than 10 nanoseconds.

Siegmund, O. H. W.↗

Temperature measurements in hypersonic air flows using laser-induced O2 fluorescence

An investigation is reported of the use of laser-induced fluorescence on oxygen for the measurement of air temperature and its fluctuations owing to turbulence in hypersonic wind tunnel flows. The results show that for temperatures higher than 60 K and densities higher than 0.01 amagat, the uncertainty in the temperature measurement can be less than 2 percent if it is limited by photon-statistical noise. The measurement is unaffected by collisional quenching and, if the laser fluence is kept below 1.5 J/sq cm, it is also unaffected by nonlinear effects which are associated with depletion of the absorbing states.

Laufer, Gabriel↗

A method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations due to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainty in the temperature and density measurements can be less than 2 and 3 percent, respectively, if the signal uncertainties are dominated by photon-statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Single pulse vibrational Raman scattering by a broadband KrF excimer laser in a hydrogen-air flame

Spontaneous vibrational Raman scattering (VRS) is produced by a broadband excimer laser at 248 nm (KrF) in a H2-air flame, and VRS spectra are recorded for lean, stoichiometric, and rich flames. Except at very lean flame conditions, laser-induced fluorescence (LIF) processes interfere with VRS Stokes lines from H2, H2O, and O2. No interference is found for the N2 Stokes and N2 anti-Stokes lines. In a stoichiometric H2/air flame, single-pulse measurements of N2 concentration and temperature (by the VRS Stokes to anti-Stokes ratio) have a relative standard deviation of 7.7 and 10 percent, respectively. These single pulse measurement errors compare well with photon statistics calculations using measured Raman cross sections.

Pitz, Robert W.↗

Method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations owing to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainties in the temperature and density measurements can be less than 2 percent, if the signal uncertainties are dominated by photon statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Imaging other planetary systems from the moon

This paper studies the problem of using a telescope like the HST, only larger and sensitive to a wider range of wavelengths, to image systems of planets like the solar system around other stars. Both reflected starlight and thermal radiation from the planets are treated. The instrumental effects of aperture diffraction, scattering due to the power spectral density of telescope mirror surface errors, and telescope thermal emission are included. The integration time required to achieve a signal-to-noise ratio is computed at 5 for photon-statistical random errors only, which is a necessary but not sufficient criterion for detection at a confidence level of five standard deviations. A cold telescope on the moon with 16m aperture and the optical quality of HST could detect and characterize planets around nearby stars.

Brown, Robert A.↗

Digital image profilers for detecting faint sources which have bright companions, phase 2

A breadboard image profiling system developed for the first phase of this project demonstrated the potential for detecting extremely faint optical sources in the presence of light companions. Experimental data derived from laboratory testing of the device supports the theory that image profilers of this type may approach the theoretical limit imposed by photon statistics. The objective of Phase 2 of this program is the development of a ground-based multichannel image profiling system capable of detecting faint stellar objects slightly displaced from brighter stars. We have finalized the multichannel image profiling system and attempted three field tests.

Morris, Elena↗