Coordinating Multiple Sources for Service Restoration to Enhance Resilience of Distribution Systems

When a major outage occurs on a distribution system due to extreme events, microgrids, distributed generators, storage devices, and other local resources can be used to restore critical loads and enhance resiliency. This paper proposes a decision-making method to determine the optimal restoration strategy coordinating multiple sources to serve critical loads after a major outage. The critical load restoration problem is formulated as a mixed -integer semidefinite program. The objective is maximizing the number of loads restored, weighted by their priority. The unbalanced three-phase power flow constraint and operational constraints are considered. An iterative algorithm is proposed to deal with integer variables and can attain the global optimum of the critical load restoration problem by solving a few semidefinite programs under mild conditions. The effectiveness of the proposed models and algorithm is validated by numerical simulation with the modified IEEE 13-node test feeder and the modified IEEE123-node test feeder under a large number of scenarios. The results indicate that the optimal restoration strategy can be determined efficiently in most scenarios

Wang, Ying↗

Dynamic Contingency Analysis Tool

The Dynamic Contingency Analysis Tool (DCAT) is an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will help find mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. The current prototype DCAT implementation has been developed as a Python code that accesses the simulation functions of the Siemens PSS/E planning tool (PSS/E). It has the following features: It uses a hybrid dynamic and steady-state approach to simulating the cascading outage sequences that includes fast dynamic and slower steady-state events. It integrates dynamic models with protection scheme models for generation, transmission, and load. It models special protection systems (SPSs)/remedial action schemes (RASs) and automatic and manual corrective actions. Overall, the DCAT attempts to bridge multiple gaps in cascading-outage analysis in a single, unique prototype tool capable of automatically simulating and analyzing cascading sequences in real systems using multiprocessor computers. While the DCAT has been implemented using PSS/E in Phase I of the study, other commercial software packages with similar capabilities can be used within the DCAT framework.

Source record↗

High Fidelity, “Faster than Real-Time” Simulator for Predicting Power System Dynamic Behavior - Final Technical Report

The “High Fidelity, Faster than Real­Time Simulator for Predicting Power System Dynamic Behavior” was designed and developed by Illinois Institute of Technology with critical contributions from Electrocon International, Argonne National Laboratory, Alstom Grid and McCoy Energy. Also essential to the project were our two utility partners: Commonwealth Edison and AltaLink. The project was a success due to several major breakthroughs in the area of large­scale power system dynamics simulation, including (1) a validated faster than real­ time simulation of both stable and unstable transient dynamics in a large­scale positive sequence transmission grid model, (2) a three­phase unbalanced simulation platform for modeling new grid devices, such as independently controlled single­phase static var compensators (SVCs), (3) the world’s first high fidelity three­phase unbalanced dynamics and protection simulator based on Electrocon’s CAPE program, and (4) a first­of­its­ kind implementation of a single­phase induction motor model with stall capability. The simulator results will aid power grid operators in their true time of need, when there is a significant risk of cascading outages. The simulator will accelerate performance and enhance accuracy of dynamics simulations, enabling operators to maintain reliability and steer clear of blackouts. In the long­term, the simulator will form the backbone of the newly conceived hybrid real­time protection and control architecture that will coordinate local controls, wide­area measurements, wide­area controls and advanced real­time prediction capabilities. The nation’s citizens will benefit in several ways, including (1) less down time from power outages due to the faster­than­real­time simulator’s predictive capability, (2) higher levels of reliability due to the detailed dynamics plus protection simulation capability, and (3) more resiliency due to the three­ phase unbalanced simulator’s ability to model three­phase and single­ phase networks and devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of GPS Data Collected on the Greenland Ice Sheet

For several years, GPS observations have been made year round at the Swiss Camp, Greenland. The GPS data are recorded for 12 hours every 10-15 days; data are stored in memory and downloaded during the annual field season. Traditional GPS analysis techniques, where the receiver is assumed not to move within a 24 hour period, is not appropriate at the Swiss Camp, where horizontal velocities are on the order of 30 cm/day. Comparison of analysis strategies for these GPS data indicate that a random walk parameterization, with a constraint of 1-2 x 10(exp -7) km/sqrt(sec) minimizes noise due to satellite outages without corrupting the estimated ice velocity. Low elevation angle observations should be included in the analysis in order to increase the number of satellites viewed at each data epoch. Carrier phase ambiguity resolution is important for improving the accuracy of receiver coordinates.

Larson, K.↗

Sequential Service Restoration for Unbalanced Distribution Systems and Microgrids

The resilience and reliability of modern power systems are threatened by increasingly severe weather events and cyber-physical security events. An effective restoration methodology is desired to optimally integrate emerging smart grid technologies and pave the way for developing self-healing smart grids. In this paper, a sequential service restoration (SSR) framework is proposed to generate restoration solutions for distribution systems and microgrids in the event of large-scale power outages. The restoration solution contains a sequence of control actions that properly coordinate switches, distributed generators, and switchable loads to form multiple isolated microgrids. The SSR can be applied for three-phase unbalanced distribution systems and microgrids and can adapt to various operation conditions. Mathematical models are introduced for three-phase unbalanced power flow, voltage regulators, transformers, and loads. Furthermore, the SSR problem is formulated as a mixed-integer linear programming model, and its effectiveness is evaluated via the modified IEEE 123 node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytic Spacecraft Attitude and Rate Estimation Performance During Attitude Sensor Outages

Analytic expressions for spacecraft attitude and rate estimation performance of an attitude estimation filter in terms of sensor specifications are useful tools for spacecraft design. Farrenkopf (1978) famously found analytic expressions for steady-state pre-update and post-update attitude and gyro bias estimate error variances for an attitude estimation filter for a single-axis spacecraft with a Rate Output Gyro (ROG). Markley and Reynolds (2000) extended the analysis for a Rate-Integrating Gyro (RIG) with angle white noise. These expressions allow for the rapid evaluation of system performance during preliminary mission design phases. One contribution of this paper is the analytic calculation of the steady-state pre-update and post-update angular rate estimate uncertainty for both the ROG and RIG cases. The primary contribution of this paper is the extension of the results for both the ROG and the RIG cases to the situation of an attitude sensor outage. This situation arises frequently in practice; for example when a star sensor’s field of view is occluded, when a star sensor’s readings are unreliable during a thruster burn that vibrates the spacecraft, or during star sensor outages due to radiation upsets. Analytic expressions for the attitude estimate uncertainty, gyro bias estimate uncertainty, and angular rate estimate uncertainty are given in terms of the attitude sensor outage interval, the star tracker measurement noise, and gyro noise parameters. Validity of the analytic results is demonstrated via Monte Carlo simulation.

Galante, Joseph M.↗

Analytic Spacecraft Attitude and Rate Estimation Performance During Attitude Sensor Outages

Analytic expressions for spacecraft attitude and rate estimation performance of an attitude estimation filter in terms of sensor specifications are useful tools for spacecraft design. Farrenkopf (1978) famously found analytic expressions for steady-state pre-update and post-update attitude and gyro bias estimate error variances for an attitude estimation filter for a single-axis spacecraft with a Rate Output Gyro (ROG). Markley and Reynolds (2000) extended the analysis for a Rate-Integrating Gyro (RIG) with angle white noise. These expressions allow for the rapid evaluation of system performance during preliminary mission design phases. One contribution of this paper is the analytic calculation of the steady-state pre-update and post-update angular rate estimate uncertainty for both the ROG and RIG cases. The primary contribution of this paper is the extension of the results for both the ROG and the RIG cases to the situation of an attitude sensor outage. This situation arises frequently in practice; for example when a star sensor’s field of view is occluded, when a star sensor’s readings are unreliable during a thruster burn that vibrates the spacecraft, or during star sensor outages due to radiation upsets. Analytic expressions for the attitude estimate uncertainty, gyro bias estimate uncertainty, and angular rate estimate uncertainty are given in terms of the attitude sensor outage interval, the star tracker measurement noise, and gyro noise parameters. Validity of the analytic results is demonstrated via Monte Carlo simulation.

Galante, Joseph M.↗

Design of High Temperature Ultrasonic Linear Arrays for Under-Sodium Viewing

This paper summarizes the design process for high temperature ultrasonic phased array transducers for imaging in liquid sodium at temperatures up to 260C. The project is funded by the USDOE Generation IV Reactor Program and includes collaboration with the Japanese Atomic Energy Agency. The transducer system is being designed to be able to provide images inside a sodium cooled fast reactor, to support operation and maintenance activities including potentially location of looseor damaged parts during service outages. The prototype transducer array is being designed for 8 to 16, 3MHz rectangular lead niobate (K-81) or bismuth titanate (K-15) piezoelectric elements spaced at λ/2 (wavelength in sodium). A nickel or nickel alloy faceplate serves as the sodium wetting surface. Scan angle of the focused ultrasonic beam is ±30 degrees. Imaging spatial resolution is ≤ 1mm. The array is designed to be operated using a commercial phased array control system and it is planned that array testing will be performed in room temperature water, hot oil (260C), and molten sodium (260C).

liquid metal fast reactor↗

Statistical analysis of cascading failures in power grids

We introduce a new microscopic model of cascading failures in transmission power grids. This model accounts for automatic response of the grid to load fluctuations that take place on the scale of minutes, when optimum power flow adjustments and load shedding controls are unavailable. We describe extreme events, caused by load fluctuations, which cause cascading failures of loads, generators and lines. Our model is quasi-static in the causal, discrete time and sequential resolution of individual failures. The model, in its simplest realization based on the Directed Current description of the power flow problem, is tested on three standard IEEE systems consisting of 30, 39 and 118 buses. Our statistical analysis suggests a straightforward classification of cascading and islanding phases in terms of the ratios between average number of removed loads, generators and links. The analysis also demonstrates sensitivity to variations in line capacities. Future research challenges in modeling and control of cascading outages over real-world power networks are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-cost wireless voltage & current grid monitoring

This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

14 SOLAR ENERGY↗

A Novel Zr-1Nb Alloy and a New Look at Hydriding

A novel Zr-1Nb has begun development based on a working model that takes into account the hydrogen permeabilities for zirconium and niobium metals. The beta-Nb secondary phase particles (SPPs) in Zr-1Nb are believed to promote more rapid hydrogen dynamics in the alloy in comparison to other zirconium alloys. Furthermore, some hydrogen release is expected at the lower temperatures corresponding to outages when the partial pressure of H2 in the coolant is less. These characteristics lessen the negative synergism between corrosion and hydriding that is otherwise observed in cladding alloys without niobium. In accord with the working model, development of nanoscale precursors was initiated to enhance the performance of existing Zr-1Nb alloys. Their characteristics and properties can be compared to oxide-dispersion strengthened alloys, and material additions have been proposed to zirconium-based LWR cladding to guard further against hydriding and to fix the size of the SPPs for microstructure stability enhancements. A preparative route is being investigated that does not require mechanical alloying, and 10 nanometer molybdenum particles have been prepared which are part of the nanoscale precursors. If successful, the approach has implications for long term dry storage of used fuel and for new routes to nanoferritic and ODS alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Adaptive-Importance-Sampling-Enhanced Bayesian Approach for Topology Estimation in an Unbalanced Power Distribution System

The reliable operation of a power distribution system relies on a good prior knowledge of its topology and its system state. Although crucial, due to the lack of direct monitoring devices on the switch statuses, the topology information is often unavailable or outdated for the distribution system operators for real-time applications. Apart from the limited observability of the power distribution system, other challenges are the nonlinearity of the model, the complicated, unbalanced structure of the distribution system, and the scale of the system. To overcome the above challenges, we, in this paper, propose a Bayesian-inference framework that allows us to simultaneously estimate the topology and the state of a three-phase, unbalanced power distribution system. Specifically, by using the very limited number of measurements available that are associated with the forecast load data, we efficiently recover the full Bayesian posterior distributions of the system topology under both normal and outage operation conditions. This is performed through an adaptive importance sampling procedure that greatly alleviates the computational burden of the traditional Monte-Carlo (MC)-sampling-based approach while maintaining a good estimation accuracy. The simulations conducted on the IEEE 123-bus test system and an unbalanced 1282-bus system reveal the excellent performances of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bonneville, Power Administration Timing System

Time is an integral part of the Bonneville Power Administration's (BPA) operational systems. Generation and power transfers are planned in advance. Utilities coordinate with each other by making these adjustments on a timed schedule. Price varies with demand, so billing is based on time. Outages for maintenance are scheduled to assure they do not interrupt reliable power delivery. Disturbance records are aligned with recorded timetags for analysis and comparison with related information. Advanced applications like traveling wave fault location and real-time phase measurement require continuous timing with high precision. Most of BPA is served by a Central Time System (CTS) at the Dittmer Control Center near Portland, OR. This system keeps time locally and supplies time to both the control center systems and field locations via a microwave signal. It is kept synchronized to national standard time and coordinated with interconnected utilities. It is the official BPA time. Powwer system control and operation is described, followed by a description of BPA timing systems including CTS, the Fault Location Acquisition Reporter, time dissemination, and phasor measurements. References are provided for further reading.

Martin, Kenneth E.↗

Demonstration of fully coupled simplified extended station black-out accident simulation with RELAP-7

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The RELAP-7 code develop-ment effort started in October of 2011 and by the end of the second development year, a number of physical components with simplified two phase flow capability have been de-veloped to support the simplified boiling water reactor (BWR) extended station blackout (SBO) analyses. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for the safety relief valve (SRV), the reactor core isolation cooling (RCIC) system, and the wet well. Three scenar-ios for the SBO simulations have been considered. Since RELAP-7 is not a severe acci-dent analysis code, the simulation stops when fuel clad temperature reaches damage point. Scenario I represents an extreme station blackout accident without any external cooling and cooling water injection. The system pressure is controlled by automatically releasing steam through SRVs. Scenario II includes the RCIC system but without SRV. The RCIC system is fully coupled with the reactor primary system and all the major components are dynamically simulated. The third scenario includes both the RCIC system and the SRV to provide a more realistic simulation. This paper will describe the major models and dis-cuss the results for the three scenarios. The RELAP-7 simulations for the three simplified SBO scenarios show the importance of dynamically simulating the SRVs, the RCIC sys-tem, and the wet well system to the reactor safety during extended SBO accidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secrecy Analysis of Uplink IM-OFDMA Systems in the Presence of IQ Imbalance

This article introduces the secrecy analysis of the index modulation-based orthogonal frequency division multiple access (IM-OFDMA) schemes by considering the in-phase and quadrature imbalance (IQI) presence at the users' RF front ends. In particular, by assuming the existence of an eavesdropper, the secrecy performance of the considered uplink multiple-access system is investigated through the strictly positive secrecy capacity and secrecy outage probability, and closed-form expressions are derived for both quantities. Moreover, the secrecy performance is conducted regarding IQI compensation based on a preamble-based estimation method. Further, analysis of the impact of the different parameters of IM-OFDMA, IQI, and estimation method is included via analytical and simulation-based results. In conclusion, the results reveal that IM-OFDMA is more reliable in secrecy performance than OFDMA, regardless of whether IQI is present. Also, IQI compensation can lead to a better secrecy performance compared to the case of no IQI.

42 ENGINEERING↗

Thermal infrared array, phase 1. Volume 1: Technical

The recommended design configuration for the focal plane array of a 1,000 element linear pushbroom system consists of 32 modules; the complete configuration is built by butting together two 1024 linear arrays. Each of the linear arrays is formed by edge butting 16 modules together. By staggering the modules of the two rows, the channel outages which occur where the modules are edge butted can be eliminated. Two stages TDI operation is performed by the post processing electronics, which reduces the design complexity of the focal plane. Systems studies show that: (1) a single focal plane design can satisfy both the LEO and SEOS mission configurations; (2) available optical designs can meet mission goals; (3) MTF can be traded with optical complexity in a future study; (4) a chopping mechanism can be devised to modifying modulate radiation to a 4-inch focal plane as well as insert two calibration sources at the required frequencies for chopping and calibration; (5) radiative cooling technology should be suitable for a future sensor in either mission configuration; and (6) cold shielding is not a requirement.

Source record↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.