Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Permeability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Changes in mast cells and in permeability of mesenteric microvessels under the effect of immobilization and electrostimulation

It was shown that a reduction in the amount of mast cells in the mesentery and an increase in their degranulation was accompanied by an increase in vascular permeability of rat mesentery. It is supposed that immobilization and electrostimulation causing degranulation of mast cells prompted histamine and serotonin release from them, thus increasing the permeability of the venular portion of the microvascular bed. Prophylactic use of esculamin preparation with P-vitaminic activity decreased mast cell degranulation, which apparently prolonged the release of histamine and serotonin from them and normalized vascular permeability.

Gorizontova, M. P.↗

Vapor-liquid phase separator permeability results

Continued studies are described in the area of vapor-liquid phase separator work with emphasis on permeabilities of porous sintered plugs (stainless steel, nominal pore size 2 micrometer). The temperature dependence of the permeability has been evaluated in classical fluid using He-4 gas at atmospheric pressure and in He-2 on the basis of a modified, thermosmotic permeability of the normal fluid.

Yuan, S. W. K.↗

Effect of water on hydrogen permeability

Doping of hydrogen with CO and CO2 was developed to reduce hydrogen permeation in Stirling engines by forming a low permeability oxide coating on the inner surface of the heater head tubes. Although doping worked well, under certain circumstances the protective oxide could be chemically reduced by the hydrogen in the engine. Some oxygen is required in the hydrogen to prevent reduction. Eventually, all the oxygen in the hydrogen gas - whatever its source - shows up as water. This is the result of hydrogen reducing the CO, CO2, or the protective inner surface oxides. This water can condense in the engine system under the right conditions. If the concentration of water vapor is reduced to a low enough level, the hydrogen can chemically reduce the oxide coating, resulting in an increase in permeability. This work was done to define the minimum water content required to avoid this reduction in the oxide coating. The results of this testing show that a minimum of approximately 750 ppm water is required to prevent an increase in permeability of CG-27, a high temperature metal alloy selected for Stirling engine heater tubes.

Hulligan, David↗

A complex permittivity and permeability measurement system for elevated temperatures

The three goals of this research include: (1) to fully develop a method to measure the permittivity and permeability of special materials as a function of frequency in the range of 2.6 to 18 GHz, and of temperature in the range of 25 to 1100 C; (2) to assist LeRC in setting up an in-house system for the measurement of high-temperature permittivity and permeability; and (3) to measure the complex permittivity and permeability of special materials as a function of frequency and temperature to demonstrate the capability of the method. The method chosen for characterizing the materials relies on perturbation of a resonant cavity with a small volume of sample material. Different field configurations in the cavity can be used to separate electric and magnetic effects. The cavity consists of a section of rectangular waveguide terminated at each end of a vertical slot iris. In the center of one wall is a small hole through which the sample is introduced.

Friederich, Paul↗

A complex permittivity and permeability measurement system for elevated temperatures

The three goals of this research include: (1) to fully develop a method to measure the permittivity and permeability of special materials as a function of frequency in the range of 2.6 to 18 GHz, and of temperatures in the range of 25 to 1100 C; (2) to assist LeRC in setting up an in-house system for the measurement of high-temperature permittivity and permeability; and (3) to measure the complex permittivity and permeability of special materials as a function of frequency and temperature to demonstrate the capability of the method. The method chosen for characterizing the materials relies on perturbation of a resonant cavity with a small volume of sample material. Different field configurations in the cavity can be used to separate electric and magnetic effects. The cavity consists of a section of rectangular waveguide terminated at each end of a vertical slot iris. The center of one wall is a small hole through which the sample is introduced.

Friederich, Paul↗

Atrial natriuretic factor increases vascular permeability

An increase in central blood volume in microgravity may result in increased plasma levels of atrial natriuretic factor (ANF). In this study, it was determined whether ANF increases capillary permeability to plasma protein. Conscious, bilaterally nephrectomized male rats were infused with either saline, ANF + saline, or hexamethonium + saline over 2 h following bolus injections of (I-125)-albumin and (C-14)-dextran of similar molecular size. Blood pressure was monitored, and serial determinations of hematocrits were made. Animals infused with 1.0 microg/kg per min ANF had significantly higher hematocrits than animals infused with saline vehicle. Infusion of ANF increased the extravasation of (I-125)-albumin, but not (C-14)-dextran from the intravascular compartment. ANF also induced a depressor response in rats, but the change in blood pressure did not account for changes in capillary permeability to albumin; similar depressor responses induced by hexamethonium were not accompanied by increased extravasation of albumin from the intravascular compartment. ANF may decrease plasma volume by increasing permeability to albumin, and this effect of ANF may account for some of the signs and symptoms of space motion sickness.

Lockette, Warren↗

Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

Upchurch, Billy T.↗

Porosity and Permeability of Chondritic Materials

We have investigated the porosity of a large number of chondritic interplanetary dust particles and meteorites by three techniques: standard liquid/gas flow techniques, a new, non-invasive ultrasonic technique, and image processing of backscattered images . The latter technique is obviously best suited to sub-kg sized samples. We have also measured the gas and liquid permeabilities of some chondrites by two techniques: standard liquid/gas flow techniques, and a new, non-destructive pressure release technique. We find that chondritic IDP's have a somewhat bimodal porosity distribution. Peaks are present at 0 and 4% porosity; a tail then extends to 53%. These values suggest IDP bulk densities of 1.1 to 3.3 g/cc. Type 1-3 chondrite matrix porosities range up to 30%, with a peak at 2%. The bulk porosities for type 1-3 chondrites have the same approximate range as exhibited by matrix, indicating that other components of the bulk meteorites (including chondrules and aggregates) have the same average porosity as matrix. These results reveal that the porosity of primitive materials at scales ranging from nanogram to kilogram are similar, implying similar accretion dynamics operated through 12 orders of size magnitude. Permeabilities of the investigated chondrites vary by several orders of magnitude, and there appears to be no simple dependence of permeability with degree of aqueous alteration, or chondrite type.

Zolensky, Michael E.↗

Hydrogen Permeability of a Polymer Based Composite Tank Material Under Tetra-Axial Strain

In order to increase the performance of future expendable and reusable launch vehicles and reduce per-pound payload launch costs, weight reductions have been sought in vehicle components. Historically, the cryogenic propellant tanks for launch vehicles have been constructed from metal. These are some of the largest structural components in the vehicle and contribute significantly to the vehicles total dry weight. A successful replacement material will be conformable, have a high strength to weight ratio, and have a low gas-permeability to the cryogens being stored, i.e., oxygen and hydrogen. Polymer-based composites are likely candidates to fill this role. Polymer and polymer-based composites in general are known to have acceptable gas permeation properties in their as-cured state.1 The use of polymer-based composites for this application has been proposed for some time.2 Some successes have been reported with oxygen3, but other than the DC-XA experience, those with hydrogen have been limited. The primary reason for this has been the small molecular diameter of hydrogen, the lower temperatures of the liquid, and that the composite materials examined to date have all been susceptible to microcrack formation in response to the thermal-mechanical cycles experienced in the use-environment. There have been numerous accounts of composite materials with reported acceptable resistance to the formation of microcracks when exposed to various mechanical and/or thermal cycles. However, virtually all of these studies have employed uniaxial loads and there has been no discussion or empirical evidence pertaining to how these loads relate to the biaxial state of stress in the material in its use environment. Furthermore, many of these studies have suffered from a lack of instrument sensitivity in detecting hydrogen permeability, no standards, insufficient documentation of test conditions, testing of cycled materials in their unload state, and/or false assumptions about the nature of the microcracks in the material. This paper documents the results of hydrogen permeability testing on a Bismaleimide (BMI) based graphite fiber composite material under a variety of tetra-axial strain states.

Stokes, Eric H.↗

A calcium-permeable cGMP-activated cation conductance in hippocampal neurons

Whole-cell patch clamp recordings detected a previously unidentified cGMP-activated membrane conductance in cultured rat hippocampal neurons. This conductance is nonselectively permeable for cations and is completely but reversibly blocked by external Cd2+. The Ca2+ permeability of the hippocampal cGMP-activated conductance was examined in detail, indicating that the underlying ion channels display a high relative permeability for Ca2+. The results indicate that hippocampal neurons contain a cGMP-activated membrane conductance that has some properties similar to the cyclic nucleotide-gated channels previously shown in sensory receptor cells and retinal neurons. In hippocampal neurons this conductance similarly could mediate membrane depolarization and Ca2+ fluxes in response to intracellular cGMP elevation.

Non-NASA Center↗

Micromechanics, Fracture Mechanics and Gas Permeability of Composite Laminates for Cryogenic Storage Systems

A micromechanics method is developed to investigate microcrack propagation in a liquid hydrogen composite tank at cryogenic temperature. The unit cell is modeled using square and hexagonal shapes depends on fiber and matrix layout from microscopic images of composite laminates. Periodic boundary conditions are applied to the unit cell. The temperature dependent properties are taken into account in the analysis. The laminate properties estimated by the micromechanics method are compared with empirical solutions using constituent properties. The micro stresses in the fiber and matrix phases based on boundary conditions in laminate level are calculated to predict the formation of microcracks in the matrix. The method is applied to an actual liquid hydrogen storage system. The analysis predicts micro stresses in the matrix phase are large enough to cause microcracks in the composite. Stress singularity of a transverse crack normal to a ply-interface is investigated to predict the fracture behavior at cryogenic conditions using analytical and finite element analysis. When a transverse crack touches a ply-interface of a composite layer with same fiber orientation, the stress singularity is equal to 1/2. When the transverse crack propagates to a stiffer layer normal to the ply-direction, the singularity becomes less than 1/2 and vice versa. Finite element analysis is performed to predict the fracture toughness of a laminated beam subjected to fracture loads measured by four-point bending tests at room and cryogenic temperatures. As results, the fracture load at cryogenic temperature is significantly lower than that at room temperature. However, when thermal stresses are taken into consideration, for both cases of room and cryogenic temperatures, the difference of the fracture toughness becomes insignificant. The result indicates fracture toughness is a characteristic property, which is independent to temperature changes. The experimental analysis is performed to investigate the effect of cryogenic cycling on permeability for various composite material systems. Textile composites have lower permeability than laminated composites even with increasing number of cryogenic cycle. Nano-particles dispersed in laminated composites do not show improvement on permeability. The optical inspection is performed to investigate the microcrack propagation and void content in laminated composites and compared the microscopic results before and after cryogenic cycling.

Choi, Sukjoo↗

Oxygen-Permeable, Hydrophobic Membranes of Silanized alpha-Al2O3

Membranes made of silanized alumina have been prepared and tested as prototypes of derivatized ceramic membranes that are both highly permeable to oxygen and hydrophobic. Improved oxygen-permeable, hydrophobic membranes would be attractive for use in several technological disciplines, including supporting high-temperature aqueousphase oxidation in industrial production of chemicals, oxygenation of aqueous streams for bioreactors, and oxygenation of blood during open-heart surgery and in cases of extreme pulmonary dysfunction. In comparison with organic polymeric oxygen-permeable membranes now commercially available, the derivatized ceramic membranes are more chemically robust, are capable of withstanding higher temperatures, and exhibit higher oxygen-diffusion coefficients.

Atwater, James E.↗

Gas Permeable Chemochromic Compositions for Hydrogen Sensing

A (H2) sensor composition includes a gas permeable matrix material intermixed and encapsulating at least one chemochromic pigment. The chemochromic pigment produces a detectable change in color of the overall sensor composition in the presence of H2 gas. The matrix material provides high H2 permeability, which permits fast permeation of H2 gas. In one embodiment, the chemochromic pigment comprises PdO/TiO2. The sensor can be embodied as a two layer structure with the gas permeable matrix material intermixed with the chemochromic pigment in one layer and a second layer which provides a support or overcoat layer.

Bokerman, Gary↗

Permeability of Two Parachute Fabrics - Measurements, Modeling, and Application

Two parachute fabrics, described by Parachute Industry Specifications PIA-C-7020D Type I and PIA-C-44378D Type I, were tested to obtain their permeabilities in air (i.e., flow-through volume of air per area per time) over the range of differential pressures from 0.146 psf (7 Pa) to 25 psf (1197 Pa). Both fabrics met their specification permeabilities at the standard differential pressure of 0.5 inch of water (2.60 psf, 124 Pa). The permeability results were transformed into an effective porosity for use in calculations related to parachutes. Models were created that related the effective porosity to the unit Reynolds number for each of the fabrics. As an application example, these models were used to calculate the total porosities for two geometrically-equivalent subscale Disk-Gap-Band (DGB) parachutes fabricated from each of the two fabrics, and tested at the same operating conditions in a wind tunnel. Using the calculated total porosities and the results of the wind tunnel tests, the drag coefficient of a geometrically-equivalent full-scale DGB operating on Mars was estimated.

Cruz, Juan R.↗

Permeability of Two Parachute Fabrics: Measurements, Modeling, and Application

Two parachute fabrics, described by Parachute Industry Specifications PIA-C-7020D Type I and PIA-C-44378D Type I, were tested to obtain their permeabilities in air (i.e., flow-through volume of air per area per time) over the range of differential pressures from 0.146 psf (7 Pa) to 25 psf (1197 Pa). Both fabrics met their specification permeabilities at the standard differential pressure of 0.5 inch of water (2.60 psf, 124 Pa). The permeability results were transformed into an effective porosity for use in calculations related to parachutes. Models were created that related the effective porosity to the unit Reynolds number for each of the fabrics. As an application example, these models were used to calculate the total porosities for two geometrically-equivalent subscale Disk-Gap-Band (DGB) parachutes fabricated from each of the two fabrics, and tested at the same operating conditions in a wind tunnel. Using the calculated total porosities and the results of the wind tunnel tests, the drag coefficient of a geometrically-equivalent full-scale DGB operating on Mars was estimated.

Cruz, Juan R.↗

Variable Permeability Magnetometer Systems and Methods for Aerospace Applications

A magnetometer configured to measure low field strength magnetic fields is provided. Certain embodiments of the magnetometer include a cylindrical coil assembly having a variable permeability core and terminals disposed at both ends. A current source circuit may be operably connected to the terminals and configured to apply a voltage controlled current across the terminals. A voltage readout circuit may be operably connected to the terminals and configured to measure a voltage across the terminals due to the applied current from the current source. An inductance of the coil assembly directly varies as an ambient magnetic field strength varies a permeability of the variable permeability core, and a voltage across the terminals varies directly with the inductance such that the measured voltage across the terminals is a direct measure of the ambient magnetic field strength.

Shams, Qamar A.↗

Permeability of a New Parachute Fabric – Measurements, Modeling, and Application

In response to a NASA request, Heathcoat Fabrics Limited has woven a new parachute fabric (Custom Design 1 G-60315-1800-Q01). This fabric was tested to obtain its permeability in air (i.e., flow-through volume of air per area per time) over a range of differential pressures from 0.146 to 25 psf (7 to 1197 Pa). The fabric met its specification permeability of 60 to 100 ft3/ft2/min (30.5 to 50.8 cm3/cm2/s) at the U.S. standard differential pressure of 0.5 inch of water (2.60 psf, 124 Pa). The permeability results were transformed into an effective porosity model for use in calculations related to the total porosity of parachutes. The tested fabric is being considered for use in parachutes for future missions to Mars. Calculations of drag coefficient were performed for two geometrically identical parachutes using either the new fabric or fabric woven to Parachute Industry Specification PIA-C-7020D Type I (Mars Science Laboratory Disk-Gap-Band parachute operating on Mars at a Mach number of 0.41). These calculations indicate essentially no difference in the drag coefficient between the two parachutes.

Cruz, Juan R.↗