Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of static and dynamic enclosures in determining DMS and OCS fluxes in Sphagnum peatlands

A static enclosure method was applied to determine the exchange of dimethyl sulfide (DMS) and OCS between the surface of Sphagnum peatlands and the atmosphere. Measurements were performed concurrently with dynamic enclosure measurements with S-free air used as sweep gas. DMS emission rates determined by both methods were comparable between 5 and 500 nmol/m(sup -2)h(sup -1). The dynamic method provided positive OCS flux rates (emission) for measurements performed at sites containing Sphagnum. Conversely, data from the static method indicated that OCS was consumed from the atmosphere. Measurements using both techniques at a site devoid of vegetation showed that peat is a source of both DMS and OCS. Results suggested that OCS is produced in surface peat but it is taken up from the atmosphere by Sphagnum mosses. However, the net effect of both processes is that OCS uptake exceeds emission. The dynamic enclosure technique is adequate to measure rates of emissions of S gases which are produced in peatlands but not consumed, as long as attention is paid to the rate of sweep flow.

Demello, William Zamboni↗

Bayesian forecasting and uncertainty quantifying of stream flows using Metropolis–Hastings Markov Chain Monte Carlo algorithm

This paper presents a Bayesian approach using Metropolis-Hastings Markov Chain Monte Carlo algorithm and applies this method for daily river flow rate forecast and uncertainty quantification for Zhujiachuan River using data collected from Qiaotoubao Gage Station and other 13 gage stations in Zhujiachuan watershed in China. The proposed method is also compared with the conventional maximum likelihood estimation (MLE) for parameter estimation and quantification of associated uncertainties. While the Bayesian method performs similarly in estimating the mean value of daily flow rate, it performs over the conventional MLE method on uncertainty quantification, providing relatively narrower reliable interval than the MLE confidence interval and thus more precise estimation by using the related information from regional gage stations. As a result, the Bayesian MCMC method might be more favorable in the uncertainty analysis and risk management.

58 GEOSCIENCES↗

Effect of Changing Weight and Mass on Human Performance in a Lunar Prototype Spacesuit

Physical effort, compensation, and controllability in a spacesuit can be affected by suit mass and gravity level. Because of limitations in certain reduced-gravity simulators and the finite selection of lunar prototype suits, it is difficult to ascertain how a change in suit mass affects suited human performance. One method of simulating a change in mass is to vary the total gravity-adjusted weight (TGAW), which is defined as the sum of the suit mass and subject mass, multiplied by the gravity level. PURPOSE: To determine if two methods of changing TGAW during parabolic flight - changing suit mass or gravity level - affect subjective ratings of suited human performance equally. METHODS: A custom weight support structure was connected to a lunar prototype spacesuit, allowing the addition of mass to the suit while maintaining a near-constant center of mass. In the varied-weight (VW) series, suit mass (120 kg) was constant at 0.1 G, 0.17 G, and 0.3 G, yielding TGAWs of 196, 333, and 588 N, assuming an 80-kg subject. In the varied-mass (VM) series, gravity level was constant at 0.17 G and suit mass was 89, 120, and 181 kg, yielding TGAWs of 282, 333, and 435 N. The 333 N condition was common to both series. Direct comparison was not possible due to limited adjustability of suit mass and limited options for parabolic profiles. Five astronaut subjects (80.3 11.8 kg) completed 4 different tasks (walk, bag pickup, lunge, and shoveling) in all conditions and provided ratings of perceived exertion (RPE) and the gravity compensation and performance scale (GCPS) upon completion of each task. RESULTS: Where VM and VW series overlapped, RPE and GCPS trendlines were similar. Mean RPE and GCPS at 333 N was 8.4 and 3.7. Mean RPE and GCPS for VM was 7.8 and 3.8 for 282 N and 9.8 and 4.1 for 435 N. Extrapolation of the VM trend to match VW TGAWs 196 and 588 N predicts an RPE of 6.5 and 12.3 and GCPS of 4.4 and 5.9, whereas the measured VW values for RPE were 8.1 and 9.8 and GCPS were 4.4 and 3.7. CONCLUSION: Modeling a change in suit mass by altering weight alone may be an adequate simulation through a limited range when looking at gross metrics of subjective suited human performance. Whether altering weight alone will be sufficient for more precise metrics of human performance, and across a wider range of activities, still needs further study.

Norcross, Jason R.↗

Tuning the Electrochemical Performance of Titanium Carbide MXene by Controllable In Situ Anodic Oxidation

Abstract MXenes are a class of two‐dimensional (2D) transition metal carbides, nitrides and carbonitrides that have shown promise for high‐rate pseudocapacitive energy storage. However, the effects that irreversible oxidation have on the surface chemistry and electrochemical properties of MXenes are still not understood. Here we report on a controlled anodic oxidation method which improves the rate performance of titanium carbide MXene (Ti 3 C 2 T x , T x refers to ‐F, =O, ‐Cl and ‐OH) electrodes in acidic electrolytes. The capacitance retention at 2000 mV s −1 (with respect to the lowest scan rate of 5 mV s −1 ) increases gradually from 38 % to 66 % by tuning the degree of anodic oxidation. At the same time, a loss in the redox behavior of Ti 3 C 2 T x is evident at high anodic potentials after oxidation. Several analysis methods are employed to reveal changes in the structure and surface chemistry while simultaneously introducing defects, without compromising electrochemically active sites, are key factors for improving the rate performance of Ti 3 C 2 T x . This study demonstrates improvement of the electrochemical performance of MXene electrodes by performing a controlled anodic oxidation.

Tang, Jun↗

Tuning the Electrochemical Performance of Titanium Carbide MXene by Controllable In Situ Anodic Oxidation

MXenes are a class of two-dimensional (2D) transition metal carbides, nitrides and carbonitrides that have shown promise for high-rate pseudocapacitive energy storage. However, the effects that irreversible oxidation have on the surface chemistry and electrochemical properties of MXenes are still not understood. In this work, we report on a controlled anodic oxidation method which improves the rate performance of titanium carbide MXene (Ti 3 C 2 T x , T x refers to -F, =O, -Cl and -OH) electrodes in acidic electrolytes. The capacitance retention at 2000 mV s -1 (with respect to the lowest scan rate of 5 mV s -1 ) increases gradually from 38% to 66% by tuning the degree of anodic oxidation. At the same time, a loss in the redox behavior of Ti 3 C 2 T x is evident at high anodic potentials after oxidation. Several analysis methods are employed to reveal changes in the structure and surface chemistry while simultaneously introducing defects, without compromising electrochemically active sites, are key factors for improving the rate performance of Ti 3 C 2 T x . This study demonstrates improvement of the electrochemical performance of MXene electrodes by performing a controlled anodic oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing Interanalyst Variability in Photovoltaic Degradation Rate Assessments

The economic return on investment of a commercial photovoltaic system depends greatly on its performance over the long term and, hence, its degradation rate. Many methods have been proposed for assessing system degradation rates from outdoor performance data. However, comparing reported values from one analyst and research group to another requires a common baseline of performance; consistency between methods and analysts can be a challenge. An interlaboratory study was conducted involving different volunteer analysts reporting on the same photovoltaic performance data using different methodologies. Initial variability of the reported degradation rates was so high that analysts could not come to a consensus whether a system degraded or not. More consistent values are received when written guidance is provided to each analyst. Further improvements in analyst variance was accomplished by using the free open-source software RdTools, allowing a reduction in variance between analysts by more than two orders of magnitude over the first round, where multiple analysis methods are allowed. This article highlights many pitfalls in conducting 'routine' degradation analysis, and it addresses some of the factors that must be considered when comparing degradation results reported by different analysts or methods.

14 SOLAR ENERGY↗

Aircraft digital control design methods

Variations in design methods for aircraft digital flight control are evaluated and compared. The methods fall into two categories; those where the design is done in the continuous domain (or s plane) and those where the design is done in the discrete domain (or z plane). Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the uncompensated s plane design method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

A comparison of digital flight control design methods

Many variations in design methods for aircraft digital flight control have been proposed in the literature. In general, the methods fall into two categories: those where the design is done in the continuous domain (or s-plane), and those where the design is done in the discrete domain (or z-plane). This paper evaluates several variations of each category and compares them for various flight control modes of the Langley TCV Boeing 737 aircraft. Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the 'uncompensated s-plane design' method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

Data from A Mass Spectrometry-Based High-Throughput Screening Method for Engineering Fatty Acid Synthases with Improved Production of Medium Chain Fatty Acids

Microbial cell factories have been extensively engineered to produce free fatty acids (FFAs) as key components of crucial nutrients, soaps, industrial chemicals, and fuels. However, our ability to control the composition of microbially synthesized FFAs is still limited, particularly, for producing medium‐chain fatty acids (MCFAs). This is mainly due to the lack of high‐throughput approaches for FFA analysis to engineer enzymes with desirable product specificity. Here we report a mass spectrometry (MS)‐based method for rapid profiling of MCFAs in Saccharomyces cerevisiae by using membrane lipids as a proxy. In particular, matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐ToF) MS was used to detect shorter acyl chain phosphatidylcholines from membrane lipids and a higher m/z peak ratio at 730 and 758 was used as an indication for improved MCFA production. This colony‐based method can be performed at a rate of ~2 s per sample, representing a substantial improvement over gas chromatography‐MS (typically >30 min per sample) as the gold standard method for FFA detection. To demonstrate the power of this method, we performed site‐saturation mutagenesis of the yeast fatty acid synthase and identified nine missense mutations that resulted in improved MCFA production relative to the wild‐type strain. Colony‐based MALDI‐ToF MS screening provides an effective approach for engineering microbial fatty acid compositions in a high‐throughput manner.

Conversion↗

A mass spectrometry-based high-throughput screening method for engineering fatty acid synthases with improved production of medium-chain fatty acids

Microbial cell factories have been extensively engineered to produce free fatty acids (FFAs), key components of crucial nutrients, soaps, industrial chemicals, and fuels. Yet, our ability to control the specificity of microbially synthesized FFAs is still limited for medium-chain fatty acids (MCFAs), which is mainly due to lack of high-throughput approaches for FFA analysis. Here we report a mass spectrometry (MS)-based method for rapid profiling of MCFAs in Saccharomyces cerevisiae by using membrane lipids as a proxy. Specially, matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF) MS was used to detect shorter acyl chain phosphatidylcholines from membrane lipids and the m/z peak ratio at 730 and 758 was used as an index for improved MCFA production. This yeast colony-based method can be performed at a rate of ~2 second per sample, which is much faster than the gold standard gas chromatography (GC)-MS (typically > 30 min per sample). To demonstrate the power of this method, we performed site-saturation mutagenesis of the yeast fatty acid synthase and identified 9 mutants that resulted in improved MCFA production relative to the wild-type strain. This colony-based MALDI-ToF MS screening method offers an alternative way for engineering microbial fatty acid compositions in a high-throughput manner.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

WE-DE-201-05: Evaluation of a Windowless Extrapolation Chamber Design and Monte Carlo Based Corrections for the Calibration of Ophthalmic Applicators

Purpose: To test the validity of a windowless extrapolation chamber used to measure surface dose rate from planar ophthalmic applicators and to compare different Monte Carlo based codes for deriving correction factors. Methods: Dose rate measurements were performed using a windowless, planar extrapolation chamber with a {sup 90}Sr/{sup 90}Y Tracerlab RA-1 ophthalmic applicator previously calibrated at the National Institute of Standards and Technology (NIST). Capacitance measurements were performed to estimate the initial air gap width between the source face and collecting electrode. Current was measured as a function of air gap, and Bragg-Gray cavity theory was used to calculate the absorbed dose rate to water. To determine correction factors for backscatter, divergence, and attenuation from the Mylar entrance window found in the NIST extrapolation chamber, both EGSnrc Monte Carlo user code and Monte Carlo N-Particle Transport Code (MCNP) were utilized. Simulation results were compared with experimental current readings from the windowless extrapolation chamber as a function of air gap. Additionally, measured dose rate values were compared with the expected result from the NIST source calibration to test the validity of the windowless chamber design. Results: Better agreement was seen between EGSnrc simulated dose results and experimental current readings at very small air gaps (<100 µm) for the windowless extrapolation chamber, while MCNP results demonstrated divergence at these small gap widths. Three separate dose rate measurements were performed with the RA-1 applicator. The average observed difference from the expected result based on the NIST calibration was −1.88% with a statistical standard deviation of 0.39% (k=1). Conclusion: EGSnrc user code will be used during future work to derive correction factors for extrapolation chamber measurements. Additionally, experiment results suggest that an entrance window is not needed in order for an extrapolation chamber to provide accurate dose rate measurements for a planar ophthalmic applicator.

07 ISOTOPE AND RADIATION SOURCES↗

Development of aircraft lavatory compartments with improved fire resistance characteristics. Phase 2: Sandwich panel resin system development

A NASA-funded program is described which aims to develop a resin system for use in the construction of lavatory wall panels, sidewall panels, and ceiling panels possessing flammability, smoke and gas emission, and toxicity (FS&T) characteristics superior to the existing epoxy resin. Candidate resins studied were phenolic, polyimide, and bismaleimide. Based on the results of a series of FS&T as well as mechanical and aesthetic property tests, a phenolic resin was chosen as the superior material. Material and process specifications covering the phenolic resin based materials were prepared and a method of rating sandwich panel performance was developed.

Anderson, R. A.↗

Improved CdTe PLR Estimates: Self-Shading and Spectral Mismatch

The RdTools year-on-year method of estimating performance loss rate (PLR) employs a simple normalization to remove the confounding effect of irradiance and temperature variation. However, the normalization's assumption that PV production scales linearly with in-plane broadband irradiance is a worse approximation for CdTe and other technologies with larger spectral sensitivities than it is for the more common c-Si technology. Additionally, CdTe systems using single-axis trackers (-20% of installed US utility-scale capacity) are subject to self-shading in the morning and afternoon, introducing another nonlinearity between PV output and broadband irradiance. Ignoring these effects may subject the estimated PLR to increased uncertainty, and perhaps bias, depending on the character of their short- and long-term variability. In this work we show that including self-shading and spectral mismatch models in the normalization for tracking CdTe systems can result not only in tighter PLR confidence intervals but different median PLRs as well. The shading and spectral models are kept simple to maintain consistency with the RdTools ethos of not requiring detailed system metadata or unusual measurements.

CdTe↗

Enhanced rate performance of Li3V2(PO4)3/C cathode by an improved rheological phase assisted microwave method

Highlights: • Rheological phase assisted microwave can utilize both advantages of two methods. • Polyethylene glycol was used as both rheological medium and carbon precursor. • 101.8 mA h g{sup −1} of specific capacity was obtained at 50 C rates. - Abstract: In this study, high-rate Li{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C composite is successfully synthesized via an improved rheological phase assisted microwave method using polyethylene glycol as both rheological medium and carbon precursor. The relatively uniform Li{sub 3}V{sub 2}(PO{sub 4}){sub 3} particles are encapsulated in amorphous carbon architecture to form core-shell structure, providing effective electron and ion transport. When used as a cathode material in lithium ion battery, the Li{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C composite displays a maximum discharge capacity of 101.8 mA h g{sup −1} at 50 C charge/discharge rate and still possesses 98.3% of capacity retention after 100 cycles, demonstrating superior rate capability and excellent cycling stability when compared with bare Li{sub 3}V{sub 2}(PO{sub 4}){sub 3}. The observed electrochemical performance could be attributed to uniform coated-carbon pyrolysis from polyethylene glycol rheological phase precursor and small Li{sub 3}V{sub 2}(PO{sub 4}){sub 3} pristine particles synthesized by the fast microwave heating route.

36 MATERIALS SCIENCE↗

The EGS Collab Project – Stimulations at Two Depths

The EGS Collab project, supported by the US Department of Energy, is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to address challenges in implementing enhanced geothermal systems (EGS). Data and observations from the field tests are compared to simulations to understand processes and build confidence in numerical modeling of the processes. We have completed Experiment 1 (of 3), which examined hydraulic fracturing in a well-characterized underground fractured phyllite test bed at a depth of approximately 1.5 km at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. Testbed characterization included fracture mapping, borehole acoustic and optical televiewers, full waveform sonic, conductivity, resistivity, temperature, campaign p- and s-wave investigations and electrical resistance tomography. Borehole geophysical techniques including passive seismic, continuous active source seismic monitoring, electrical resistance tomography, fiber-based distributed strain, distributed temperature, and distributed acoustic monitoring, were used to carefully monitor stimulation events and flow tests. More than a dozen stimulations and nearly one year of flow tests were performed. Quality data and detailed observations were collected and analyzed during stimulation and water flow tests using ambient temperature and chilled water. We achieved adaptive control of the tests using real-time monitoring and rapid dissemination of data and near-real-time simulation. More detailed numerical simulation was performed to answer key experimental design questions, forecast fracture propagation trajectories and extents, and analyze and evaluate results. Data are freely available from the Geothermal Data Repository. Experiment 2 examines the potential for hydraulic shearing in amphibolite at a depth of about 1.25 km at SURF. This site has a different set of stress and fracture conditions than Experiment 1. The Experiment 2 testbed consists of nine subhorizontal boreholes configured in two fans of two boreholes which surround the testbed and contain grouted-in electrical resistance tomography, seismic sensors, active seismic sources and distributed fiber sensors. A “five-spot” set of test wells that extends from a custom mined alcove includes an injection well and four production/monitoring wells. The testbed was characterized geophysically and hydrologically, and three stimulations have been performed using the Step-Rate Injection Method for Fracture In-Situ Properties (SIMFIP) tool to measure strains, and a new strain quantifying tool (downhole robotic strain analysis tool -DORSA) was deployed in a monitoring hole during stimulation. Real-time data were broadcast during stimulations to allow real-time response to arising issues.

EGS Collab, Enhanced Geothermal Systems, EGS, fiel↗

Dry-processed electrodes enabled by polytetrafluoroethylene fibrillation for high-performance lithium-ion batteries

The dry processing technique of polytetrafluoroethylene (PTFE) fibrillation offers significant advancements in cost reduction, environmental impact, and electrochemical performance. Dry processing alone allows for ∼ 20–60% cost reduction and increases of up to 40 mg cm⁻2 of areal loading – it typically comes at a reduction of rate capability. By leveraging the network structure of fibers, this method enhances rate capability and cycling performance, providing a compelling alternative to the conventional and currently predominant wet processing. The review delves into PTFE fibrillation mechanisms and examines critical influencing factors including material properties and processing parameters. It also discusses challenges associated with the electrodes fabricated by PTFE fibrillation, including structural instability due to insufficient PTFE fibrillization, compromised electrical conductivity from an insufficient conductive network, inhomogeneous dispersion resulting from the absence of solvents, restricted ionic transport due to increased electrode thickness, inadequate adhesion to current collector because of low surface energy of PTFE, electrochemical degradation due to low lowest unoccupied molecular orbital (LUMO) level of PTFE, particle damage during processing and environmental concerns related PTFE being a perfluoroalkyl and polyfluoroalkyl substances (PFAS). Recent research innovations aimed at mitigating these issues, their application in beyond-lithium batteries, and future research directions are thoroughly discussed.

Park, Hyunji↗

An Experimental Investigation of Leak Rate Performance of a Subscale Candidate Elastomer Docking Space Seal

A novel docking seal was developed for the main interface seal of NASA s Low Impact Docking System (LIDS). This interface seal was designed to maintain acceptable leak rates while being exposed to the harsh environmental conditions of outer space. In this experimental evaluation, a candidate docking seal assembly called Engineering Development Unit (EDU58) was characterized and evaluated against the Constellation Project leak rate requirement. The EDU58 candidate seal assembly was manufactured from silicone elastomer S0383-70 vacuum molded in a metal retainer ring. Four seal designs were considered with unique characteristic heights. The leak rate performance was characterized through a mass point leak rate method by monitoring gas properties within an internal control volume. The leakage performance of the seals were described herein at representative docking temperatures of -50, +23, and +50 C for all four seal designs. Leak performance was also characterized at 100, 74, and 48 percent of full closure. For all conditions considered, the candidate seal assemblies met the Constellation Project leak rate requirement.

Garafolo, Nicholas G.↗