Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle Track Output”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Last Journey. I. An Extreme-scale Simulation on the Mira Supercomputer

The Last Journey is a large-volume, gravity-only, cosmological N-body simulation evolving more than 1.24 trillion particles in a periodic box with a side length of 5.025 Gpc. It was implemented using the HACC simulation and analysis framework on the BG/Q system Mira. The cosmological parameters are chosen to be consistent with the results from the Planck satellite. A range of analysis tools have been run in situ to enable a diverse set of science projects and, at the same time, keep the resulting data amount manageable. Analysis outputs have been generated starting at redshift z ~ 10 to allow for construction of synthetic galaxy catalogs using a semianalytic modeling approach in postprocessing. As part of our in situ analysis pipeline, we employ a new method for tracking halo substructures, introducing the concept of subhalo cores. The production of multiwavelength synthetic sky maps is facilitated by generating particle light cones in situ, also beginning at z ~ 10. We provide an overview of the simulation setup and generated data products; a first set of analysis results is presented. A subset of the data is publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

AC-LGADs Fermilab front-end electronics characterization

Here, we characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the time resolution is influenced by the front-end electronics. To achieve this, we developed a setup capable of generating input signals with varying amplitudes. The output results demonstrated that signal processing by the front-end electronics plays a crucial role in enhancing time resolution. We showed that the time resolution achieved by the FEE board is better than 2 p s at the 1 σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Microbially Induced Calcite Precipitation for the Immobilization of Strontium-90 Using a Variable Velocity Streamtube Ensemble (Final Technical Report)

Biogeochemical modeling using PHREEQC2 and a streamtube ensemble approach is utilized to understand a well-to-well subsurface treatment system at the Vadose Zone Research Park (VZRP) near Idaho Falls, Idaho. Treatment involves in situ microbially-mediated ureolysis to induce calcite precipitation for the immobilization of strontium-90. PHREEQC2 is utilized to model the kinetically-controlled ureolysis and consequent calcite precipitation. Reaction kinetics, equilibrium phases, and cation exchange are used within PHREEQC2 to track pH and levels of calcium, ammonium, urea, and calcite precipitation over time, within a series of one-dimensional advective-dispersive transport paths creating a streamtube ensemble representation of the well-to-well transport. An understanding of the impact of physical heterogeneities within this radial flowfield is critical for remediation design; we address this via the streamtube approach: instead of depicting spatial extents of solutes in the subsurface we focus on their arrival distribution at the control well(s). Traditionally, each streamtube maintains uniform velocity; however in radial flow in homogeneous media, the velocity within any given streamtube is spatially-variable in a common way, being highest at the input and output wells and approaching a minimum at the midpoint between the wells. This idealized velocity variability is of significance in the case of ureolytically driven calcite precipitation. Streamtube velocity patterns for any particular configuration of injection and withdrawal wells are available as explicit calculations from potential theory, and also from particle tracking programs. To approximate the actual spatial distribution of velocity along streamtubes, we assume idealized radial non-uniform velocity associated with homogeneous media. This is implemented in PHREEQC2 via a non-uniform spatial discretization within each streamtube that honors both the streamtube’s travel time and the idealized “fast-slow-fast” pattern of non-uniform velocity along the streamline. Breakthrough curves produced by each simulation are weighted by the path-respective flux fractions (obtained by deconvolution of tracer tests conducted at the VZRP) to obtain the flux-average of flow contributions to the observation well.

54 ENVIRONMENTAL SCIENCES↗

Measurements and models of reactive transport in geological media

Reactive chemical transport plays a key role in geological media across scales, from pore scale to aquifer scale. Systems can be altered by changes in solution chemistry and a wide variety of chemical transformations, including precipitation/dissolution reactions that cause feedbacks that directly affect the flow and transport regime. The combination of these processes with advective-dispersive-diffusive transport in heterogeneous media leads to a rich spectrum of complex dynamics. The principal challenge in modeling reactive transport is to account for the subtle effects of fluctuations in the flow field and species concentrations; spatial or temporal averaging generally suppresses these effects. Moreover, it is critical to ground model conceptualizations and test model outputs against laboratory experiments and field measurements. This paper emphasizes the integration of these aspects, considering carefully designed and controlled experiments at both laboratory and field scales, in the context of development and solution of reactive transport models based on continuum-scale and particle tracking approaches. We first discuss laboratory experiments and field measurements that define the scope of the phenomena and provide data for model comparison. We continue by surveying models involving advection-dispersion-reaction equation and continuous time random walk formulations. The integration of measurements and models is then examined, considering a series of case studies in different frameworks. We delineate the underlying assumptions, and strengths and weaknesses, of these analyses, and the role of probabilistic effects. Finally, we also show the key importance of quantifying the spreading and mixing of reactive species, recognizing the role of small-scale physical and chemical fluctuations that control the initiation of reactions.

58 GEOSCIENCES↗

SU-F-T-165: Daily QA Analysis for Spot Scanning Beamline

Purpose: The dosimetric results of our daily quality assurance over the last 8 years for discrete pencil beam scanning proton therapy will be presented. Methods: To perform the dosimetric checks, a multi-ion chamber detector is used, which consists of an array of 5 single parallel plate ion chambers that are aligned as a cross separated by 10cm each. The Tracker is snapped into a jig, which is placed on the tabletop. Different amounts of Solid Water buildup are added to shift the dose distribution. The dosimetric checks consist of 3 parts: position check, range check and volume dose check. Results: The average deviation of all position-check data were 0.2±1.3%. For the range check, the average deviation was 0.1%±1.2%, which also corresponds to a range stability of better than 1 mm over all measurements. The volumetric dose output readings were all within ±1% with the exception of 2 occasions when the cable to the dose monitor was being repaired. Conclusion: Morning QA using the Tracker device gives very stable dosimetric readings but is also sensitive to mechanical and output changes in the proton therapy delivery system.

07 ISOTOPE AND RADIATION SOURCES↗

Large-Scale Transport Model Uncertainty and Sensitivity Analysis: Distributed Sources in Complex Hydrogeologic Systems

The Underground Test Area (UGTA) Project of the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is in the process of assessing and developing regulatory decision options based on modeling predictions of contaminant transport from underground testing of nuclear weapons at the Nevada Test Site (NTS). The UGTA Project is attempting to develop an effective modeling strategy that addresses and quantifies multiple components of uncertainty including natural variability, parameter uncertainty, conceptual/model uncertainty, and decision uncertainty in translating model results into regulatory requirements. The modeling task presents multiple unique challenges to the hydrological sciences as a result of the complex fractured and faulted hydrostratigraphy, the distributed locations of sources, the suite of reactive and non-reactive radionuclides, and uncertainty in conceptual models. Characterization of the hydrogeologic system is difficult and expensive because of deep groundwater in the arid desert setting and the large spatial setting of the NTS. Therefore, conceptual model uncertainty is partially addressed through the development of multiple alternative conceptual models of the hydrostratigraphic framework and multiple alternative models of recharge and discharge. Uncertainty in boundary conditions is assessed through development of alternative groundwater fluxes through multiple simulations using the regional groundwater flow model. Calibration of alternative models to heads and measured or inferred fluxes has not proven to provide clear measures of model quality. Therefore, model screening by comparison to independently-derived natural geochemical mixing targets through cluster analysis has also been invoked to evaluate differences between alternative conceptual models. Advancing multiple alternative flow models, sensitivity of transport predictions to parameter uncertainty is assessed through Monte Carlo simulations. The simulations are challenged by the distributed sources in each of the Corrective Action Units, by complex mass transfer processes, and by the size and complexity of the field-scale flow models. An efficient methodology utilizing particle tracking results and convolution integrals provides in situ concentrations appropriate for Monte Carlo analysis. Uncertainty in source releases and transport parameters including effective porosity, fracture apertures and spacing, matrix diffusion coefficients, sorption coefficients, and colloid load and mobility are considered. With the distributions of input uncertainties and output plume volumes, global analysis methods including stepwise regression, contingency table analysis, and classification tree analysis are used to develop sensitivity rankings of parameter uncertainties for each model considered, thus assisting a variety of decisions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Velocity field calculation for non-orthogonal numerical grids

Computational grids containing cell faces that do not align with an orthogonal (e.g. Cartesian, cylindrical) coordinate system are routinely encountered in porous-medium numerical simulations. Such grids are referred to in this study as non-orthogonal grids because some cell faces are not orthogonal to a coordinate system plane (e.g. xy, yz or xz plane in Cartesian coordinates). Non-orthogonal grids are routinely encountered at the Savannah River Site in porous-medium flow simulations for Performance Assessments and groundwater flow modeling. Examples include grid lines that conform to the sloping roof of a waste tank or disposal unit in a 2D Performance Assessment simulation, and grid surfaces that conform to undulating stratigraphic surfaces in a 3D groundwater flow model. Particle tracking is routinely performed after a porous-medium numerical flow simulation to better understand the dynamics of the flow field and/or as an approximate indication of the trajectory and timing of advective solute transport. Particle tracks are computed by integrating the velocity field from cell to cell starting from designated seed (starting) positions. An accurate velocity field is required to attain accurate particle tracks. However, many numerical simulation codes report only the volumetric flowrate (e.g. PORFLOW) and/or flux (flowrate divided by area) crossing cell faces. For an orthogonal grid, the normal flux at a cell face is a component of the Darcy velocity vector in the coordinate system, and the pore velocity for particle tracking is attained by dividing by water content. For a non-orthogonal grid, the flux normal to a cell face that lies outside a coordinate plane is not a true component of velocity with respect to the coordinate system. Nonetheless, normal fluxes are often taken as Darcy velocity components, either naively or with accepted approximation. To enable accurate particle tracking or otherwise present an accurate depiction of the velocity field for a non-orthogonal grid, Darcy velocity components are rigorously derived in this study from normal fluxes to cell faces, which are assumed to be provided by or readily computed from porous-medium simulation code output. The normal fluxes are presumed to satisfy mass balances for every computational cell, and if so, the derived velocity fields are consistent with these mass balances. Derivations are provided for general two-dimensional quadrilateral and three-dimensional hexagonal systems, and for the commonly encountered special cases of perfectly vertical side faces in 2D and 3D and a rectangular footprint in 3D.

97 MATHEMATICS AND COMPUTING↗

MO-F-CAMPUS-T-04: Implementation of a Standardized Monthly Quality Check for Linac Output Management in a Large Multi-Site Clinic

Purpose: This work is to investigate the feasibility of a standardized monthly quality check (QC) of LINAC output determination in a multi-site, multi-LINAC institution. The QC was developed to determine individual LINAC output using the same optimized measurement setup and a constant calibration factor for all machines across the institution. Methods: The QA data over 4 years of 7 Varian machines over four sites, were analyzed. The monthly output constancy checks were performed using a fixed source-to-chamber-distance (SCD), with no couch position adjustment throughout the measurement cycle for all the photon energies: 6 and 18MV, and electron energies: 6, 9, 12, 16 and 20 MeV. The constant monthly output calibration factor (Nconst) was determined by averaging the machines’ output data, acquired with the same monthly ion chamber. If a different monthly ion chamber was used, Nconst was then re-normalized to consider its different NDW,Co-60. Here, the possible changes of Nconst over 4 years have been tracked, and the precision of output results based on this standardized monthly QA program relative to the TG-51 calibration for each machine was calculated. Any outlier of the group was investigated. Results: The possible changes of Nconst varied between 0–0.9% over 4 years. The normalization of absorbed-dose-to-water calibration factors corrects for up to 3.3% variations of different monthly QA chambers. The LINAC output precision based on this standardized monthly QC relative to the TG-51 output calibration is within 1% for 6MV photon energy and 2% for 18MV and all the electron energies. A human error in one TG-51 report was found through a close scrutiny of outlier data. Conclusion: This standardized QC allows for a reasonably simplified, precise and robust monthly LINAC output constancy check, with the increased sensitivity needed to detect possible human errors and machine problems.

60 APPLIED LIFE SCIENCES↗

An Artificial neural network based $b$ jet identification algorithm at the CDF Experiment

We present the development and validation of a new multivariate $b$ jet identification algorithm ('$b$ tagger') used at the CDF experiment at the Fermilab Tevatron. At collider experiments, $b$ taggers allow one to distinguish particle jets containing $B$ hadrons from other jets. Employing feed-forward neural network architectures, this tagger is unique in its emphasis on using information from individual tracks. This tagger not only contains the usual advantages of a multivariate technique such as maximal use of information in a jet and tunable purity/efficiency operating points, but is also capable of evaluating jets with only a single track. To demonstrate the effectiveness of the tagger, we employ a novel method wherein we calculate the false tag rate and tag efficiency as a function of the placement of a lower threshold on a jet's neural network output value in $Z+1$ jet and $t\bar{t}$ candidate samples, rich in light flavor and $b$ jets, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extending the dynamic range of electronics in a Time Projection Chamber

When Time Projection Chambers (TPCs) are used in low to intermediate heavy ion collisions, the mass and momentum range of the emitted particles cover a wide range in energy losses. Many TPC readout electronics currently only have a single gain output with a fixed dynamic range. In a recent set of experiments using the SAMURAI Pion-Reconstruction and Ion-Tracker (StrRIT) TPC, it was important to simultaneously measure relativistic pions and heavy ion tracks from the same collisions. As the ionization from a track's energy loss is collected and multiplied by the anode wires, a distribution of image charges is induced on the TPC read-out pads. If the avalanche on a wire is large enough, the charge collected by pads directly underneath will saturate the readout electronics; pads farther away in the distribution will not be saturated. Using these unsaturated pads and the known pad distribution function, we can estimate the charge on saturated pads, increasing the dynamic range by a factor of 5.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS Fast TracKer system

The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited $\eta$-$\phi$ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conditional Point Sampling: A Monte Carlo Method for Radiation Transport in Stochastic Media.

Current methods for stochastic media transport are either computationally expensive or, by nature, approximate. Moreover, none of the well-developed, benchmarked approximate methods can compute the variance caused by the stochastic mixing, a quantity especially important to safety calculations. Therefore, we derive and apply a new conditional probability function (CPF) for use in the recently developed stochastic media transport algorithm Conditional Point Sampling (CoPS), which 1) leverages the full intra-particle memory of CoPS to yield errorless computation of stochastic media outputs in 1D, binary, Markovian-mixed media, and 2) leverages the full inter-particle memory of CoPS and the recently developed Embedded Variance Deconvolution method to yield computation of the variance in transport outputs caused by stochastic material mixing. Numerical results demonstrate errorless stochastic media transport as compared to reference benchmark solutions with the new CPF for this class of stochastic mixing as well as the ability to compute the variance caused by the stochastic mixing via CoPS. Using previously derived, non-errorless CPFs, CoPS is further found to be more accurate than the atomic mix approximation, Chord Length Sampling (CLS), and most of memory-enhanced versions of CLS surveyed. In addition, we study the compounding behavior of CPF error as a function of cohort size (where a cohort is a group of histories that share intra-particle memory) and recommend that small cohorts be used when computing the variance in transport outputs caused by stochastic mixing.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-379: Evaluation of An EPID-Based System for Daily Dosimetry Check by Comparison with a Widely-Used Ionization Chamber-Based Device

Purpose: To examine the feasibility of using Varian’s EPID-based Machine Performance Check (MPC) system to track daily machine output through comparison with Sun Nuclear’s DailyQA3 (DQA) device. Methods: Daily machine outputs for two photon energies (6 and 16MV) and five electron energies (6, 9, 12, 16, 20MeV) were measured for one month using both MPC and DQA. Baselines measurements for MPC were taken at the start of the measurement series, while DQA baselines were set at an earlier date. In order to make absolute comparisons with MPC, all DQA readings were referenced to the average of the first three DQA readings in that series, minimizing systematic differences between the measurement techniques due to baseline differences. In addition to daily output measurements, weekly averages were also calculated and compared. Finally, the electron energy dependence of each measurement technique was examined by comparing energy-specific measurements to the average electron output of all energies each day. Results: For 6 and 16MV photons, the largest absolute percent differences between MPC and DQA were 0.60% and 0.73%, respectively. Weekly averages were within 0.17% and 0.23%, respectively. For all five electron energies, the greatest absolute percent differences between MPC and DQA for each energy ranged from 0.49%–0.83%. Weekly averages ranged from 0.07%–0.28%. DQA energy-specific electron readings matched the average electron output within 0.29% for all days and all energies. MPC energy-specific readings matched the average within 0.21% for 9–20MeV. However, 6MeV showed a larger distribution about the average with four days showing a difference greater than 0.30% and a maximum difference of 0.51%. Conclusion: MPC output measurements correlated well with the widely-used DQA3 for most beam energies, making it a reliable back up technique for daily output monitoring. However, MPC may display an energy dependence for lower electrons energies, requiring additional investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive machine learning for time-varying systems: low dimensional latent space tuning

Machine learning (ML) tools such as encoder-decoder convolutional neural networks (CNN) can represent incredibly complex nonlinear functions which map between combinations of images and scalars. For example, CNNs can be used to map combinations of accelerator parameters and images which are 2D projections of the 6D phase space distributions of charged particle beams as they are transported between various particle accelerator locations. Despite their strengths, applying ML to time-varying systems, or systems with shifting distributions, is an open problem, especially for large systems for which collecting new data for re-training is impractical or interrupts operations. Particle accelerators are one example of large time-varying systems for which collecting detailed training data requires lengthy dedicated beam measurements which may no longer be available during regular operations. We present a novel method of adaptive ML for time-varying systems. Our approach is to map very high (N ≈ 100k) dimensional inputs (a combination of scalar parameters and images) into the low dimensional (N ≈ 2) latent space at the output of the encoder section of an encoder-decoder CNN. We then actively tune the low dimensional latent space-based representation of complex system dynamics by the addition of an adaptively tuned feedback vector directly before the decoder sections builds back up to our image-based high-dimensional phase space density representations. This method allows us to learn correlations within and to quickly tune the characteristics of incredibly large parameter space systems and to track their evolution in real time based on feedback without massive new data sets for re-training. We demonstrate that our method can accurately predict and track the phase space of charged particle beams at various locations in a particle accelerator by adaptively adjusting in real-time while the unknown input beam distribution of the accelerator is changing in shape, charge, and offset and while the RF system of the accelerator itself is also changing in an unpredictable way. For FACET-II we demonstrate that such an approach has the potential to use transverse deflecting cavity and energy spread spectrum beam measurements to accurately predict 2D projections of the 6D phase space of the electron beam at the plasma wakefield acceleration interaction point where such diagnostics are unavailable.

47 OTHER INSTRUMENTATION↗

Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2

The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2. The final single-hit spatial resolution, averaged over 1172 monitored drift tube chambers, is $81.7 \pm 2.2 \mu$m.

47 OTHER INSTRUMENTATION↗

l3d2vtk: An MCNPTools Utility to Enable LNK3DNT File Visualization & Post-Processing

This paper describes recent work to develop and incorporate a utility program into the MCNPTools package that enables LNK3DNT file visualization & post-processing. A LNK3DNT file is a binary Cartesian, cylindrical, or spherical structured mesh file that describes material and material relative density distributions by mesh voxel. This mesh file format is principally used by the PARTISN discrete-ordinates radiation-transport code. However, the MCNP ® Monte Carlo radiation-transport code can use LNK3DNT files to specify geometry, and the MCNP code can produce LNK3DNT files representing a user-defined region of the MCNP constructive solid geometry (CSG). Because of the use of LNK3DNT files as MCNP input and output and with other computer codes, improving the ability to visualize and/or quantitatively post-process LNK3DNT files benefits end users. In particular, it is helpful to visually verify that the material and density distributions are as expected. Also, an analyst can orient viewers with respect to other in formation, e.g., by co-plotting a voxelized representation of MCNP CSG with mesh tally and/or particle track results. However, until now, the only capability to interactively interrogate LNK3DNT files is through a 2-D slice plotter provided by the Monte Carlo Application ToolKit (MCATK), which is not currently distributed outside of Los Alamos National Laboratory. The utility created as part of this work converts LNK3DNT binary files to an ASCII XML-based StructuredMesh VTK (.vts) file. The geometries supported are 1-D spherical and cylindrical ( r ), 1-D Cartesian ( x ), 2-D cylindrical ( r-z and r-θ ) and Cartesian ( x-y ), and 3-D cylindrical ( r-z-θ ) and Cartesian ( x-y-z ). This file format is chosen to minimize external dependencies (e.g., on an HDF5 library) and to provide a file that can be interrogated by the user in a text editor or standard visualization applications (e.g., ParaView or VisIt). However, other file formats may provide more utility such as XDMF, which can use HDF5 and is discussed further as something to explore as future work. This paper is organized as follows: a brief introduc tion to the MCNPTools library and utility programs is given, the LNK3DNT-to-VTK (l3d2vtk) utility functionality is de scribed, and then an example post-processing workflow using the ParaView application is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An adaptive approach to machine learning for compact particle accelerators

Abstract Machine learning (ML) tools are able to learn relationships between the inputs and outputs of large complex systems directly from data. However, for time-varying systems, the predictive capabilities of ML tools degrade if the systems are no longer accurately represented by the data with which the ML models were trained. For complex systems, re-training is only possible if the changes are slow relative to the rate at which large numbers of new input-output training data can be non-invasively recorded. In this work, we present an approach to deep learning for time-varying systems that does not require re-training, but uses instead an adaptive feedback in the architecture of deep convolutional neural networks (CNN). The feedback is based only on available system output measurements and is applied in the encoded low-dimensional dense layers of the encoder-decoder CNNs. First, we develop an inverse model of a complex accelerator system to map output beam measurements to input beam distributions, while both the accelerator components and the unknown input beam distribution vary rapidly with time. We then demonstrate our method on experimental measurements of the input and output beam distributions of the HiRES ultra-fast electron diffraction (UED) beam line at Lawrence Berkeley National Laboratory, and showcase its ability for automatic tracking of the time varying photocathode quantum efficiency map. Our method can be successfully used to aid both physics and ML-based surrogate online models to provide non-invasive beam diagnostics.

97 MATHEMATICS AND COMPUTING↗

Radioluminescence Investigation of Ion-Irradiated Phosphors

Phosphors are materials that emit light under the excitation of incoming radiation. This property is used, among other applications, in radiation detection. Efficient energy transfer from the ionization track to the luminescent centers must occur to yield significant light output. Besides, the investigation of the effects of ion irradiation on the luminescence of phosphors is comparatively unexplored. In this work, we review radioluminescence (RL) investigation of ion-irradiated oxides and oxide phosphors, and present preliminary data on the effects of ion irradiation on the luminescence of intrinsic phosphor Bi{sub 4}Ge{sub 3}O{sub 12}(BGO). Commercial crystals were irradiated, and the irradiation effects characterized by means of RL measurements as a function of temperature, from 10 K to room temperature (RT), and optical absorption measurements. Overall, surface modification induced by ion irradiation leads to higher luminescence output.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗