At least 55 records · Page 3

Noise suppressed partial volume correction for cardiac SPECT/CT

Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.

60 APPLIED LIFE SCIENCES↗

Pelletization of Immobilized Amine Carbon Dioxide Sorbents with Fly Ash and Poly(vinyl chloride)

Abstract A combination of coal fly ash (FA) and a polymer binder, namely, poly(vinyl chloride) (PVC), was used to pelletize immobilized amine CO 2 sorbents. The pelletization of mixtures of FA and 50 wt % tetraethylenepentamine (TEPA) or ethylenimine oligomer mixture ( M w =423)/silica (EI 423 ‐S) with PVC created a rigid PVC/FA/sorbent network. The strength of the network was attributed, in part, to the hydrogen bonding of PVC with the hydroxy and amine groups of the FA and sorbent (infrared spectroscopy). Increasing the PVC molecular weight or FA content enhanced the pellet strength and reduced CO 2 capture. The optimum pellet, FA/EI 423 ‐S (20/80)_PVC 62 [10 wt % PVC 62 ( M w =62 000), 17 wt % FA], captured 1.33 mmol g −1 and exhibited a crush strength of 1.42 MPa. The reaction between PVC and amines produced ammonium ions (−NH 3 + /−NH 2 + ), which reduced the CO 2 captured by the pellet during stability testing. This issue was partially resolved by replacing PVC 62 with p ‐phenylenediamine‐modified PVC 62 , which also enhanced the pellet CO 2 capture to 1.5 mmol g −1 .

Wilfong, Walter Christopher↗

High-performance polyvinyl chloride gel artificial muscle actuator with graphene oxide and plasticizer

A transparent and electroactive plasticized polyvinyl chloride (PVC) gel was investigated to use as a soft actuator for artificial muscle applications. PVC gels were prepared with varying plasticizer (dibutyl adipate, DBA) content. The prepared PVC gels were characterized using Fourier-transform infrared spectroscopy, thermogravimetric analysis, and dynamic mechanical analysis. The DBA content in the PVC gel was shown to have an inverse relationship with both the storage and loss modulus. The electromechanical performance of PVC gels was demonstrated for both single-layer and stacked multi-layer actuators. When voltage was applied to a single-layer actuator and then increased, the maximum displacement of PVC gels (for PVC/DBA ratios of 1:4, 1:6, and 1:8) was increased from 105.19, 123.67, and 135.55µm (at 0.5kV) to 140.93, 157.13, and 172.94µm (at 1.0kV) to 145.03, 191.34, and 212.84µm (at 1.5kV), respectively. The effects of graphene oxide (GO) addition in the PVC gel were also investigated. The inclusion of GO (0.1 wt.%) provided an approximate 20% enhancement of displacement and 41% increase in force production, and a 36% increase in power output for the PVC/ GO gel over traditional plasticizer only PVC gel. The proposed PVC/GO gel actuator may have promising applications in artificial muscle, small mechanical devices, optics, and various opto-electro-mechanical devices due to its low-profile, transparency, and electrical response characteristics.

59 BASIC BIOLOGICAL SCIENCES↗

A novel process for separation of hazardous poly(vinyl chloride) from mixed plastic wastes by froth flotation

Highlights: • A novel method was proposed for separation of PVC by froth flotation. • Calcium hypochlorite treatment improves selectively surface wettablity. • Mechanism of surface treatment was examined by SEM, FTIR and XPS. •Binary plastics with different particle sizes were separated effectively. • Separation of PVC from mixed plastic wastes was obtained. - Abstract: A novel method, calcium hypochlorite (CHC) treatment, was proposed for separation of hazardous poly(vinyl chloride) (PVC) plastic from mixed plastic wastes (MPWs) by froth flotation. Flotation behavior of single plastic indicates that PVC can be separated from poly(ethylene terephthalate) (PET), poly(acrylonitrile-co-butadiene-co-styrene) (ABS), polystyrene (PS), polycarbonate (PC) and poly(methyl methacrylate) (PMMA) by froth flotation combined with CHC treatment. Mechanism of CHC treatment was examined by contact angle measurement, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Under the optimum conditions, separation of PVC from binary plastics with different particle sizes is achieved efficiently. The purity of PC, ABS, PMMA, PS and PET is greater than 96.8%, 98.5%, 98.8%, 97.4% and 96.3%, respectively. Separation of PVC from multi-plastics was further conducted by two-stage flotation. PVC can be separated efficiently from MPWs with residue content of 0.37%. Additionally, reusing CHC solution is practical. This work indicates that separation of hazardous PVC from MPWs is effective by froth flotation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrocatalytic grafting of polyvinyl chloride plastics

Polyvinyl chloride (PVC) plastics require high loadings of plasticizers and stabilizers to achieve commercially useful bulk properties. However, these non-covalent additives leach from PVC over time, resulting in the loss of their tailored functionality. This work details the electrocatalytic functionalization of PVC to covalently graft plasticizing additives directly onto the polymer backbone. Here, mechanistic insights guided the design of electrocatalysts capable of modifying C–Cl bonds of PVC under mild conditions with high selectivity while suppressing side reactions such as elimination and chain scission. Functional groups that mimic PVC plasticizers are covalently installed into the backbone of PVC to create new materials with distinct bulk properties from the original polymer. The degree of polymer grafting is easily controlled by simply changing the redox capacity that is passed during electrolysis. This strategy is employed to create chemically- and leach-resistant PVC materials by directly electrolyzing mixtures of consumer PVC products

Zackasee, Jordan L.S.↗

Characteristics and radiolysis behavior of polyvinylchloride under accelerated proton and γ-irradiation

Here the effect of high energy protons and γ-irradiation on the structural properties, surface-energies, and toxicological properties of polyvinyl chloride (PVC) were studied due to the role PVC products play in many technologies including the nuclear industry. Accelerated 1–4 MeV protons impacting on PVC in vacuum lead to the formation of polyenyl radicals as shown by EPR and to an increase in free surface energy due to functionalization of the surface of the irradiated polymer. γ-irradiation leads to the formation of unsaturated bonds, carbonyl and hydroxyl groups as shown by IR and to the release of HCl. Correlated molecular orbital theory calculations of reaction thermodynamics were used to aid in the development of a mechanism in the absence of oxygen. The formation and accumulation of chromophores and auxochromic groups during γ-radiolysis of PVC leads to a gradual change of the initial white color of the polymer to yellow and then to brown and black with high sensitivity. A mixture of powdered PVC and silicate glue was used to determine the profile of a 60 Co γ-radiation beam on targets with a complex relief. γ-irradiated polymer does not have a local irritating effect due to a single application to the skin of mice in an adhesive mixture at a concentration of up to 5000 mg/kg. γ-radiolysis of PVC powder in air with a dose of up to 1400 kGy does not affect its acute toxicity when administered intragastrically to BDF1 mice. PVC and its γ-irradiated analogs are non-toxic at doses ≤5000 mg/kg.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Highly Stretchable, Ultratough, and Multifunctional Poly(vinyl chloride)-Based Plastics via a Green, Star-Shaped Macromolecular Additive

As one of the most prolifically produced plastics in the world, poly(vinyl chloride) (PVC) suffers from mechanical brittleness and low toughness. Compared with traditional phthalate-type plasticizers, poly(ε-caprolactone) (PCL)-based plasticizers are especially attractive due to their “green” nature and capabilities to achieve improved physical properties. Herein, a stretchable and ultratough PVC-based plastic was achieved by a star-shaped PCL copolymer with a rigid, amino-containing, branched polylactide (N-BPLA) core and a soft PCL shell, that is, RN-SPCLs. With an optimal feed ratio of the CL monomer and N-BPLA core, the RN-SPCL2 can efficiently lower the glass transition temperature (T g ) of PVC plastics, achieving the transition from the “glassy” to “rubbery” state at ambient temperature. The obtained RN-SPCL2/PVC not only shows high extensibility, that is, 453%, but also maintains close to 80% of tensile strength of neat PVC, that is, 30.1 MPa, which is much higher than the previously reported plasticized PVCs. Its overall toughness reaches 92.7 MJ/m 3 , being more than 50-fold higher than neat PVC and 2 to 3 times higher than linear PCL or dibutyl phthalate plasticized PVCs. The important role of star-shaped architecture with a rigid core and flexible PCL shell for RN-SPCL2 in achieving highly stretchable and ultratough PVC plastics is systematically investigated. More interestingly, the as-prepared RN-SPCLs also endow PVC plastics with photoluminescence property and allow homogeneous dispersion of nanosized TiO 2 for significantly enhancing the anti-UV capability.

36 MATERIALS SCIENCE↗

Controlling selectivity for dechlorination of poly(vinyl chloride) with (xantphos)RhCl

Reaction of poly(vinyl chloride) (PVC) with 5 equiv. of triethyl silane in THF, in the presence of in situ generated (xantphos)RhCl catalyst, results in partial reduction of PVC via hydrodechlorination to yield poly(vinyl chloride-co-ethylene). Increasing catalyst loading or using N,N-dimethylacetamide (DMA) as a solvent both diminished selectivity for hydrodechlorination, promoting competitive dehydrochlorination reactions. Reaction of PVC with 2 equiv. of sodium formate in THF in the presence of (xantphos)RhCl affords excellent selectivity for hydrodechlorination along with complete PVC dechlorination, yielding polyethylene-like polymers. Higher catalyst loadings were necessary to activate PVC towards reduction in this case. In contrast, reaction of PVC with 1 equiv. of NaH in DMA, in the presence of (xantphos)RhCl, exhibited good selectivity for dehydrochlorination, as well as much higher reaction rates. These results combined shed light on the interplay between critical reaction parameters that control PVC's mode of reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and flux assessment of airborne phthalates released from polyvinyl chloride consumer goods

Highlights: • Enhanced levels of semi-volatile organic compounds (SVOCs) can affect human health. • The major SVOCs like phthalates are released into indoor by many sources like plasticizers. • This study investigated the emission characteristics of diverse phthalates from plastic/rubber products. • Emission behavior of phthalates is described in relation to several key variables, e.g., types of PVC. The concentrations and fluxes of airborne phthalates were measured from five types of polyvinyl chloride (PVC) consumer products (vinyl flooring, wallcovering, child's toy, yoga mat, and edge protector) using a small chamber (impinger) system. Airborne phthalates released from each of those PVC samples were collected using sorbent (Tenax TA) tubes at three temperature control intervals (0, 3, and 6 h) under varying temperature conditions (25, 40, and 90 °C). A total of 11 phthalate compounds were quantified in the five PVC products examined in this study. To facilitate the comparison of phthalate emissions among PVC samples, their flux values were defined for total phthalates by summing the average fluxes of all 11 phthalates generated during the control period of 6 h. The highest flux values were seen in the edge protector sample at all temperatures (0.40 (25 °C), 9.65 (40 °C), and 75.7 μg m{sup −2} h{sup −1} (90 °C)) of which emission was dominated by dibutyl isophthalate. In contrast, the lowest fluxes were found in wallcovering (0.01 (25 °C) and 0.05 μg m{sup −2} h{sup −1} (40 °C)) and child's toy (0.23 μg m{sup −2} h{sup −1} (90 °C)) at each temperature level. The information regarding phthalate composition and emission patterns varied dynamically with type of PVC sample, controlled temperature, and duration of control.

54 ENVIRONMENTAL SCIENCES↗

Formation and fluidity measurement of supported lipid bilayer on polyvinyl chloride membrane

We prepared an artificial lipid bilayer on a plasticized poly(vinyl chloride) (PVC) membrane on a Si3N4 layer deposited on a Si wafer. We optimized the experimental condition for the fabrication of the PVC membrane, and obtained a PVC membrane with a flat and uniform surface on the scale of several hundreds of micrometer suitable for a substrate for supported lipid bilayers (SLBs). The SLB of 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) was formed on the PVC membrane by the vesicle fusion method. The observation with a conventional epi-fluorescence microscope and a confocal laser scanning microscope gave geometrically uniform images of the SLB on the PVC membrane. The fluidity and the mobile fraction of the SLB was evaluated by the fluorescence recovery after photobleaching method, and compared with that on a thermally oxidized SiO{sub 2}/Si substrate. The SLB on the PVC membrane contained immobile fraction ∼30%, but the diffusion in the mobile fraction was two times faster than that in the SLB on SiO{sub 2}/Si, which had little immobile fraction.

36 MATERIALS SCIENCE↗

Probiotics for Rectal Volume Variation During Radiation Therapy for Prostate Cancer

Purpose: To investigate the effect of the probiotic Lactobacillus acidophilus on the percentage volume change of the rectum (PVC{sub R}), a crucial factor of prostate movement. Methods and Materials: Prostate cancer patients managed with tomotherapy as a radical treatment were enrolled in the study to take a probiotic capsule containing 1.0 × 10{sup 8} colony-forming units of L acidophilus or a placebo capsule twice daily. Radiation therapy was performed at a dose of 78 Gy in 39 fractions. The PVC{sub R}, defined as the difference in rectal volume between the planning computed tomographic (CT) and daily megavoltage CT images, was analyzed. Results: Forty patients were randomized into 2 groups. The L acidophilus group showed significantly lower median rectal volume and median PVC{sub R} values than the placebo group. L acidophilus showed a significant reduction effect on the PVC{sub R} (P<.001). However, the radiation therapy fraction number did not significantly influence the PVC{sub R}. Conclusions: L acidophilus was useful in reducing the PVC{sub R}, which is the most important determining factor of prostate position, during radiation therapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface treatment with Fenton for separation of acrylonitrile-butadiene-styrene and polyvinylchloride waste plastics by flotation

Highlights: • Surface treatment with Fenton was developed for flotation separation of waste plastics. • Surface treatment changes selectively the floatability of ABS surface. • Mechanism of surface treatment was studied by FT-IR and XPS analysis. • Plastic mixtures with different particle sizes and mass fractions were separated effectively. - Abstract: Surface treatment with Fenton was applied to flotation separation of acrylonitrile-butadienestyrene (ABS) and polyvinylchloride (PVC). After treatment, the floatability of ABS has a dramatic decrease, while the floatability of PVC is not affected. Fourier transform infrared spectroscopy (FT-IR) spectra and X-ray photoelectron spectroscopy (XPS) spectra were recorded to ascertain the mechanism of Fenton treatment. FT-IR and XPS analysis confirms that the introduction of oxygen-containing group occurs on the surface of ABS. The optimum conditions are molar ration (H{sub 2}O{sub 2}:Fe{sup 2+}) 10000, H{sub 2}O{sub 2} concentration 0.4 M/L, pH 5.8, treatment time 2 min and temperature 25 °C, frother concentration 15 mg/L and flotation time 3 min. Particle sizes and mixing ratios were also investigated. Plastic mixtures of ABS and PVC with different particle sizes and mixing ratios can be effectively separated. The purity of ABS and PVC are up to 100% and 99.78%, respectively; the recovery of ABS and PVC are up to 99.89% and 100%, respectively. A practical, environmentally friendly and effective reagent, namely Fenton, was originally applied to surface treatment of ABS and PVC waste plastics for flotation separation of their mixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hard Carbon Originated from Polyvinyl Chloride Nanofibers As High-Performance Anode Material for Na-Ion Battery

Two types of hard carbon materials were synthesized through direct pyrolysis of commercial polyvinyl chloride (PVC) particles and pyrolysis of PVC nanofibers at 600-800 degrees C, respectively, where the nanofibers were prepared by an electrospinning PVC precursors method. These as-prepared hard carbon samples were used as anode materials for Na-ion batteries. The hard carbon obtained from PVC nanofibers achieved a high reversible capacity of 271 mAh/g and an initial Coulombic efficiency of 69.9%, which were much superior to the one from commercial PVC, namely, a reversible capacity of 206 mAh/g and an initial Coulombic efficiency of 60.9%. In addition, the hard carbon originated from the PVC nanofibers exhibited good cycling stability and rate performance: the initial discharge capacities were 389, 228, 194, 178, 147 mAh/g at the current density of 12, 24, 60, 120, and 240 mA/g, respectively, retaining 211 mAh/g after 150 cycles. Such excellent cycle performance, high reversible capacity, and good rate capability enabled this hard carbon to be a promising candidate as anode material for Na-ion battery application.

electrospinning↗

Investigation of realistic PET simulations incorporating tumor patient's specificity using anthropomorphic models: Creation of an oncology database

Purpose: The GATE Monte Carlo simulation toolkit is used for the implementation of realistic PET simulations incorporating tumor heterogeneous activity distributions. The reconstructed patient images include noise from the acquisition process, imaging system's performance restrictions and have limited spatial resolution. For those reasons, the measured intensity cannot be simply introduced in GATE simulations, to reproduce clinical data. Investigation of the heterogeneity distribution within tumors applying partial volume correction (PVC) algorithms was assessed. The purpose of the present study was to create a simulated oncology database based on clinical data with realistic intratumor uptake heterogeneity properties.Methods: PET/CT data of seven oncology patients were used in order to create a realistic tumor database investigating the heterogeneity activity distribution of the simulated tumors. The anthropomorphic models (NURBS based cardiac torso and Zubal phantoms) were adapted to the CT data of each patient, and the activity distribution was extracted from the respective PET data. The patient-specific models were simulated with the Monte Carlo Geant4 application for tomography emission (GATE) in three different levels for each case: (a) using homogeneous activity within the tumor, (b) using heterogeneous activity distribution in every voxel within the tumor as it was extracted from the PET image, and (c) using heterogeneous activity distribution corresponding to the clinical image following PVC. The three different types of simulated data in each case were reconstructed with two iterations and filtered with a 3D Gaussian postfilter, in order to simulate the intratumor heterogeneous uptake. Heterogeneity in all generated images was quantified using textural feature derived parameters in 3D according to the ground truth of the simulation, and compared to clinical measurements. Finally, profiles were plotted in central slices of the tumors, across lines with heterogeneous activity distribution for visual assessment.Results: The accuracy of the simulated database was assessed against the original clinical images. The PVC simulated images matched the clinical ones best. Local, regional, and global features extracted from the PVC simulated images were closest to the clinical measurements, with the exception of the size zone variability and the mean intensity values, where heterogeneous tumors showed better reproducibility. The profiles on PVC simulated tumors after postfiltering seemed to represent the more realistic heterogeneous regions with respect to the clinical reference.Conclusions: In this study, the authors investigated the input activity map heterogeneity in the GATE simulations of tumors with heterogeneous activity distribution. The most realistic heterogeneous tumors were obtained by inserting PVC activity distributions from the clinical image into the activity map of the simulation. Partial volume effect (PVE) can play a crucial role in the quantification of heterogeneity within tumors and have an important impact on applications such as patient follow-up during treatment and assessment of tumor response to therapy. The development of such a database incorporating patient anatomical and functional variability can be used to evaluate new image processing or analysis algorithms, while providing control of the ground truth, which is not available when dealing with clinical datasets. The database includes all images used and generated in this study, as well as the sinograms and the attenuation phantoms for further investigation. It is freely available to the interested reader of the journal at http://www.med.upatras.gr/oncobase/.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of partial volume correction and analysis of longitudinal [ 18 F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models

Purpose: We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [ 18 F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM). Methods: We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden–level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates. Results: The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability. Conclusion: The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [ 18 F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test–retest variability. Clinical trial registration: NCT02640092 and NCT03289143.

60 APPLIED LIFE SCIENCES↗

A novel process for separation of polycarbonate, polyvinyl chloride and polymethyl methacrylate waste plastics by froth flotation

Highlights: • KMnO{sub 4} treatment changes selectively flotation behavior of PC, PVC and PMMA plastics. • Ternary waste plastics are separated efficiently by froth flotation. • Recycling of KMnO{sub 4} solutions is conducted to make the process green. • A novel process is proposed for separation of waste plastics by froth flotation. - Abstract: A novel process was proposed for separation of ternary waste plastics by froth flotation. Pretreatment of plastics with potassium permanganate (KMnO{sub 4}) solution was conducted to aid flotation separation of polycarbonate (PC), polyvinyl chloride (PVC) and polymethyl methacrylate (PMMA) plastics. The effect of pretreatment parameters including KMnO{sub 4} concentration, treatment time, temperature and stirring rate on flotation recovery were investigated by single factor experiments. Surface treatment with KMnO{sub 4} changes selectively the flotation behavior of PC, PVC and PMMA, enabling separation of the plastics by froth flotation. Mechanism of surface treatment was studied by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray photoelectron spectrum (XPS). Effect of frother concentration and flotation time on flotation behavior of plastic mixtures was further studied for flotation separation. The optimized conditions for separation of PC are KMnO{sub 4} concentration 2 mmol L{sup −1}, treatment time 10 min, temperature 60 °C, stirring rate 300 rpm, flotation time 1 min and frother concentration 17.5 mg L{sup −1}. Under optimum conditions, PVC and PMMA mixtures are also separated efficiently by froth flotation associated with KMnO{sub 4} treatment. The purity of PC, PVC and PMMA is up to 100%, 98.41% and 98.68%, while the recovery reaches 96.82%, 98.71% and 98.38%, respectively. Economic analysis manifests remarkable profits of the developed process. Reusing KMnO{sub 4} solution is feasible, enabling the process greener.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Effects in the Poly-N-Vinylcaprolactam/Titanium(IV) Oxides Nanocomposite System and Their Nature

Nanocomposites based on poly-N-vinylcaprolactam (PVC), characterized by different drying temperatures of aqueous PVC solution at 25°С (PVC25) and 40°С (PVC40), with titanium(IV) oxide nanoparticles (TONs) (η-phase (TP: TiO{sub 2–x} · mH{sub 2}O) with a superstructure to the anatase structure and ordered solid solution with partial replacement of oxygen atoms in the η-phase with peroxo group O {sub 2}{sup 2–} (PP: TiO{sub x}(O{sub 2}){sub 2–x} · nH{sub 2}O)) have been obtained for the first time and characterized by X-ray diffraction and IR spectroscopy. It is found that a common feature of TP/PVC and PP/PVC obtained by dry mixing and grinding is the decrease in the number of water molecules for TP and PP in the interlayer space of the structure and their attachment to the PVC amide groups; the differences are related to the specificity of PVC behavior in these systems: mechanodestruction of PVC in PP/PVC40 and different numbers of water molecules in PVC25 and PVC40.

36 MATERIALS SCIENCE↗