Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV field performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

PV Reliability Operations and Maintenance (PVROM) Database Initiative: 2014 Project Report

To fill a major knowledge gap, Sandia National Laboratories (SNL) and the Electric Power Research Institute (EPRI) are jointly engaged in a multi-year research effort, supported by the Department of Energy’s SunShot Program, to examine real-world photovoltaic (PV) plant reliability and performance. Findings and analyses, derived from field data documented in the PV Reliability Operations Maintenance (PVROM) database tool as well as from convened workshops and working group discussions, are intended to inform industry best practices around the optimal operations and maintenance (O&M) of solar PV assets. To improve upon and evolve existing solar PV O&M approaches, this report: 1. Provides perspective on the concept of PV “system” reliability and how it can inform plant design, operations, and maintenance decisions that produce better long-term outcomes; 2. Describes the PVROM data collection tool, its technical capabilities, and results generated from database content in 2014; 3. Presents ongoing research efforts that are meant to drive the solar industry toward PV O&M best practice protocols and standards; and 4. Reflects on future areas of inquiry that can help better forecast plant health (e.g., system component availability, component wear out, etc.) and associated lifecycle costs. Ultimately, this report adds to the knowledge base of improving PV system O&M activities by discussing data collection and analysis techniques that can be used to better understand and enhance the reliability, availability, and performance of a photovoltaic system.

14 SOLAR ENERGY↗

Experimental Comparison of PV-Smoothing Controllers using Distributed Generators

The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

14 SOLAR ENERGY↗

Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems

Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.

14 SOLAR ENERGY↗

Measured and estimated performance of a fleet of shaded photovoltaic systems with string and module-level inverters

Shade obstructions can significantly impact the performance of photovoltaic (PV) systems. Although there are many models for partially shaded PV arrays, there is a lack of information available regarding their accuracy and uncertainty when compared with actual field performance. This work assesses the recorded performance of 46 residential PV systems, equipped with either string-level or module-level inverters, under a variety of shading conditions. We compare their energy production data to annual PV performance predictions, with a focus on the practical models developed here for National Renewable Energy Laboratory's system advisor model software. This includes assessment of shade extent on each PV system by using traditional onsite surveys and newer 3D obstruction modelling. The electrical impact of shade is modelled by either a nonlinear performance model or assumption of linear impact with shade extent, depending on the inverter type. When applied to the fleet of residential PV systems, performance is predicted with median annual bias errors of 2.5% or less, for systems with up to 20% estimated shading loss. The partial shade models are not found to add appreciable uncertainty to annual predictions of energy production for this fleet of systems but do introduce a monthly root-mean-square error of approximately 4%-9% due to seasonal effects. Here the use of a detailed 3D model results in similar or improved accuracy over site survey methods, indicating that, with proper description of shade obstructions, modelling of partially shaded PV arrays can be done completely remotely, potentially saving time and cost.

14 SOLAR ENERGY↗

OPET Firmware (Open PV Electrical Tool Firmware) [SWR-25-43]

The main application of OPET is long term performance measurements of PV devices in field or under controlled environmental conditions. This repository contains everything relating to the firmware of the OPET device including source code. If you are looking for the hardware or control software repositories, links are below: https://github.com/NREL/opet-hardware https://github.com/NREL/opet-control

McDanold, Byron [National Renewable Energy Laborat↗

Industry Facing PV Degradation Prediction Tool and Database to Enable a 50 Year Life Module

The goal of this work is to create an online tool that can be used to search for degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published open-source allowing users to expand on the existing framework.

degradation↗

Photovoltaic Data Acquisition (PVDAQ) Public Datasets

The NREL PVDAQ is a large-scale time-series database containing system metadata and performance data from a variety of experimental PV sites and commercial public PV sites. The datasets are used to perform on-going performance and degradation analysis. Some of the sets can exhibit common elements that effect PV performance (e.g. soiling). The dataset consists of a series of files devoted to each of the systems and an associated set of metadata information that explains details about the system hardware and the site geo-location. Some system datasets also include environmental sensors that cover irradiance, temperatures, wind speeds, and precipitation at the site.

Array↗

PV Lifetime Project: Measuring PV Module Performance Degradation: 2018 Indoor Flash Testing Results

Photovoltaic (PV) module and system performance degradation is being measured by periodic flash testing of fielded PV modules at three sites. As of early 2018, results from modules fielded in New Mexico and Colorado are now available. These data indicate that module degradation varies significantly between module types and can also vary between modules of the same model. In addition, degradation rates for some module types appear to vary over time. Great care is made to control for stability and repeatability in the measurements over time, but there is still a +/-0.5% uncertainty in flash test stability. Therefore, it will take several more years for degradation rate results to be known with higher confidence.

14 SOLAR ENERGY↗

Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

14 SOLAR ENERGY↗

Reliability of tandem solar cells and modules: what's next?

Hybrid tandem photovoltaic (PV) technology development has gained momentum in the last few years. This has been motivated by a need to push module efficiencies beyond what is theoretically capable with single-junction technologies to further accelerate total global PV deployment. Significant advances have been made with multiple material systems achieving tandem efficiencies over 30% in the last decade. All of the highest record efficiencies have been from laboratory-scale devices, with areas of 1 cm2 or less. Interestingly, there are multiple material combinations and terminal configurations that have demonstrated promising results. Despite these high laboratory efficiencies, reasonable service lifetimes (a useful operating lifetime of at least 25 years) are needed for tandems to compete with the levelized cost of energy (LCOE) of traditional single junction PV technologies. Existing commercial Si PV products have demonstrated performance in the field with an average of less than 1% relative annual degradation in module and system performance, and many manufacturers now provide 30 year warranties on their products.

14 SOLAR ENERGY↗

Laboratory and Field Characterization of the Electrical Response of Modules Containing Configurable Current Cells (C3) Under Non-Optimal Conditions Such as Shading (Final Report)

This work is to be conducted in support of the American Made Challenges Solar Prize. The intent is to connect competitor teams with national laboratories that can help accelerate the development of innovative solutions and products. Teams who have won the Set! and Go! Contests are eligible to utilize vouchers at national laboratories to advance their ideas. Laboratory and field characterization of the electrical response of modules containing Configurable Current Cells (C3) under non-optimal conditions such as shading.

14 SOLAR ENERGY↗

Power modeling of degraded PV systems: Case studies using a dynamically updated physical model (PV-Pro)

Power modeling, widely applied for health monitoring and power prediction, is crucial for the efficiency and reliability of Photovoltaic (PV) systems. The most common approach for power modeling uses a physical equivalent circuit model, with the core challenge being the estimation of model parameters. Traditional parameter estimation either relies on datasheet information, which does not reflect the system's current health status, especially for degraded PV systems, or requires additional I-V characterization, which is generally unavailable for large-scale PV systems. Thus, we build upon our previously developed tool, PV-Pro (originally proposed for degradation analysis), to enhance its application for power modeling of degraded PV systems. PV-Pro extracts model parameters from production data without requiring I-V characterization. This dynamic model, periodically updated, can closely capture the actual degradation status, enabling precise power modeling. PV-Pro is compared with popular power modeling techniques, including persistence, nominal physical, and various machine learning models. The results indicate that PV-Pro achieves outstanding power modeling performance, with an average nMAE of 1.4 % across four field-degraded PV systems, reducing error by 17.6 % compared to the best alternative technique. Furthermore, PV-Pro demonstrates robustness across different seasons and severities of degradation. The tool is available as a Python package at https://github.com/DuraMAT/pvpro.

14 SOLAR ENERGY↗

Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint

The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

14 SOLAR ENERGY↗

A bending test protocol for characterizing the mechanical performance of flexible photovoltaics

Flexible photovoltaics (PV) represents a promising research field with great potential for wearable, portable, and indoor applications. Significant progress has been made in recent years, with flexible emerging PV reporting power conversion efficiency (PCE) over 24%. Yet, there is a need for a unifying protocol to assess PV performance, compare research results, and evaluate the state- of-the-art achievements in flexible PV. In this paper, a consensus protocol is presented for measuring PCE over 1,000 bending cycles under 1% strain. Moreover, several good practice guidelines are proposed including bending procedures, flexibility testing with and without encapsulation, and ambient conditions during testing (e.g., temperature, humidity, illumination). Notably, the importance of uniform application of bending radius and the testing of parallel and perpendicular orientations of bending axis with respect to the direction of the electric current are emphasized. These recommendations aim to promote consistency in device comparison and allow for better reproducibility.

Fukuda, Kenjiro↗

AI and ML Applications for PV Reliability and System Performance

This poster discusses AI and ML topics in PV reliability and system performance. In particular, automated metadata extraction and QA for fielded solar installations is covered for the PV Fleets Project. Additionally, statistical learning topics for the PVInsight Project are addressed, as well as development of the PV Validation Hub.

algorithm↗

Data for Validating Models for PV Module Performance

This data encompasses performance data measured for flat-plate photovoltaic (PV) modules installed in Cocoa, Florida; Eugene, Oregon; and Golden, Colorado. The data include PV module current-voltage curves and associated meteorological data for approximately one-year periods. The data was acquired with the NREL Performance and Energy Rating Testbed (PERT) and the mobile Performance and Energy Rating Testbed (mPERT).

PV, Validation, IV Curves, Field performance, mPER↗

The Baseline Performance Reference for Irradiance in PV System Applications

This report proposes the definition of a new baseline performance reference (BPR). The definition goes beyond existing standards pertaining to photovoltaic (PV) reference cells and devices to define the response under all possible operating conditions in the field. Field evaluations using BPR devices will be more sensitive to performance anomalies than pyranometers because they track PV system power output more closely. At the same time, they will be able to detect a broader range of performance anomalies than traditional matched reference devices, which might have matching defects. The BPR definition also opens the door to new practices in resource assessment and yield prediction. Solar resource data can be collected or modeled and validated directly as BPR irradiance, and PV system simulations based on BPR irradiance need fewer assumptions and less processing to obtain the effective irradiance on modules. As a result, lower uncertainty in yield assessments can be expected.

14 SOLAR ENERGY↗