Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER SUPPLIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Schematic for the CAEN backup Power-supply [Slides]

J158 in the schematic shown below is the physical power switch for the UDCM. You will see that we really only care about 3 pins on this physical switch, pins 1,2 and 6. we are going to splice between the switch and the board, meaning we are ‘effectively’ elevating this component to become part of our own module, and then have our module interface with the board. So when I say ‘Pin 1 Switch’ I am literally referring the Switch’s pin 1. Whereas when I say ‘Pin 1 Board’ I am talking about the part of the board that originally would have interfaced with pin 1 on the switch as shown in the lower left corner.

42 ENGINEERING↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.

combined heat and power (CHP)↗

Nuclear Thermal Energy Storage Configurations for Industrial Combined Heat and Power Supply: Conceptual Study and Engineering Designs

The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smart controller with phantom inductor current sensing for switched mode power supplies

Voltage on the output terminal of an inductor is obtained as a first input signal to a control block (CB); the inductor has an input terminal connected to a power switch and driver block at a switching node. A sense input voltage is obtained on an output terminal of a sensing circuit that is not directly connected to the switching node, as a second input signal to the CB. A voltage is generated on a first output terminal of the CB and is selected such that the CB can use its first and second input signals to infer the current through the inductor. A pulse width modulation (PWM) signal is generated on a second output terminal of the CB, based on the inferred current through the inductor; the second output signal from the CB is provided to a PWM input terminal of the power switch and driver block.

Zhang, Xin↗

System and method of wireless power supply

A system and method for sensorless coil detection that exploits a dead-time effect in a WPT inverter as an indicator of presence of a receiver. In one embodiment, a system described herein may be configured to detect arrival of a moving receiver prior to alignment of the moving receiver with the transmitter for power transmission.

Kavimandan, Utkarsh D.↗

A multi-model assessment of global freshwater temperature and thermoelectric power supply under climate change

Water temperature is a key abiotic factor influencing aquatic ecosystem health and the services provided to both nature and humans. Global water temperature models offer possibilities to improve our understanding of water temperature regimes, which is increasingly important against the backdrop of climate change. Yet, existing studies have predominantly relied on a single model, which can lead to an incomplete representation of uncertainty and potential biases, in addition to limited insight into the range of possible future conditions, which ultimately reduces the robustness of climate impact assessments. Here, we provide a comprehensive assessment of surface freshwater temperature changes from various river and lake models for both past conditions and under future scenarios of climate change. Global models consistently simulate that surface water temperatures are currently 0.5 °C–0.8 °C higher than at the turn of the century (i.e. 1981–2000), and that warming will extend and intensify with future global change throughout the 21st century. While the strength of warming is highly sensitive to the different water temperature models, emissions scenarios and global climate models, our multi-model ensemble shows a global average annual water temperature rise of between +1.3 °C and +4.1 °C by the end of the century. To illustrate a potential societal impact of our results, we evaluate how future changes in discharge and water temperature may affect existing thermoelectric power plants, estimating average annual reductions of 1.5%–6% in global usable capacity by the end of the century. However, with river water temperatures projected to exhibit more pronounced seasonal patterns in the future—especially under the more extreme climate change scenarios and during summer months in the Northern Hemisphere—intra-annual reductions in usable capacity can be much more severe. Given the challenges associated with (large-scale) adaptation to control water temperature regimes, strong climate change mitigation is crucial for minimising water temperature rises and its associated negative impacts on humankind and ecosystems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Synchronization and phase locking of resonant magnet power supplies for Mu2e experiment at Fermilab

The Mu2e Experiment has stringent beam structure requirements; namely, it requires short (~200 ns) proton bunches separated by 1.5-2.0 $\mu$s. This beam structure will be produced using the Fermilab 8 GeV Booster, the 8 GeV Recycler Ring, and the Delivery Ring, which was formerly part of the antiproton accumulator system. Out of time beam is limited to a fraction of level of no more than $1\times 10^{-10}$, a requirement known as "extinction". Achieving this level of extinction requires a system of resonant magnets and collimators, phased such that only in time particles will pass through. The Mu2e magnet system involves two components: a 300 kHz component, timed such that the 600 kHz beam will pass through the collimators at the nodes, and a 4.5 MHz system to reduce the slewing of the in-time beam. These two systems must be precisely phase locked to the bunch rate coming from the Delivery Ring, which itself must be phased to match beam transfers coming from the Recycler. This poster describes the control system for the magnets, which is based on an Intel Arria FPGA, which handles phase locking of the magnets to the Delivery Ring, including the phase jumps required to match transfers from the Recycler.

43 PARTICLE ACCELERATORS↗

Electron storage ring power supply system design report

In January 2020, U.S. Secretary of Energy Dan Brouillette announced the decision to build an Electron Ion Collider (EIC) at Brookhaven National Laboratory (BNL). While advancing the state of the art of particle colliders, the EIC will enable the U.S. nuclear physics community, with world wide participation, to take a giant step forward in the centuries-old quest to understand the nature of matter at its most fundamental level, providing the clearest picture yet of how the elemental quarks and gluons interact to form the basic structure of atoms and nuclei. The EIC at Brookhaven National Laboratory will be the first particle accelerator capable of colliding polarized ions with polarized electrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed Power Supply for Magnet Quench Training

Superconducting magnets typically go through aseries of spontaneous “training” quenches as their current isincreased towards its design value. To decrease the number ofthese quenches, a device has been designed to boost the magnetcurrent at the moment a quench has been detected and beforemagnet protection has been initiated. The aim of the boost is todrive the magnet coil further along towards its maximum currentwith each training quench, and hence reduce the number ofquenches required.

43 PARTICLE ACCELERATORS↗