Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM 241”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

241 Am Ingrowth and Its Effect on Internal Dose

Generally, plutonium has been manufactured to support commercial and military applications involving heat sources, weapons and reactor fuel. This work focuses on three typical plutonium mixtures, while observing the potential of 241 Am ingrowth and its effect on internal dose. The term “ingrowth” is used to describe 241 Am production due solely from the decay of 241 Pu as part of a plutonium mixture, where it is initially absent or present in a smaller quantity. Dose calculation models do not account for 241 Am ingrowth unless the 241 Pu quantity is specified. This work suggested that 241 Am ingrowth be considered in bioassay analysis when there is a potential of a 10% increase to the individual’s committed effective dose. It was determined that plutonium fuel mixtures, initially absent of 241 Am, would likely exceed 10% for typical reactor grade fuel aged less than 30 years; however, heat source grade and aged weapons grade fuel would normally fall below this threshold. In conclusion, although this work addresses typical plutonium mixtures following separation, it may be extended to irradiated commercial uranium fuel and is expected to be a concern in the recycling of spent fuel.

241Am↗

A Second Look at Neutron Resonance Transmission Analysis as a Spent Fuel NDA Technique

Many different nondestructive analysis techniques are currently being investigated as a part of the United States Department of Energy's Next Generation Safeguards Initiative (NGSI) seeking methods to quantify plutonium in spent fuel. Neutron Resonance Transmission Analysis (NRTA) is one of these techniques. Having first been explored in the mid-1970s for the analysis of individual spent-fuel pins a second look, using advanced simulation and modeling methods, is now underway to investigate the suitability of the NRTA technique for assaying complete spent nuclear fuel assemblies. The technique is similar to neutron time-of-flight methods used for cross-section determinations but operates over only the narrow 0.1-20 eV range where strong, distinguishable resonances exist for both the plutonium (239, 240, 241,242Pu) and uranium (235,236,238U) isotopes of interest in spent fuel. Additionally, in this energy range resonances exists for six important fission products (99Tc, 103Rh, 131Xe, 133Cs, 145Nd, and 152Sm) which provide additional information to support spent fuel plutonium assay determinations. Initial modeling shows excellent agreement with previously published experimental data for measurements of individual spent-fuel pins where plutonium assays were demonstrated to have a precision of 2-4%. Within the simulation and modeling analyses of this project scoping studies have explored fourteen different aspects of the technique including the neutron source, drift tube configurations, and gross neutron transmission as well as the impacts of fuel burn up, cooling time, and fission-product interferences. These results show that NRTA may be a very capable experimental technique for spent-fuel assay measurements. The results suggest sufficient transmission strength and signal differentiability is possible for assays through up to 8 pins. For an 8-pin assay (looking at an assembly diagonally), 64% of the pins in a typical 17 ? 17 array of a pressurized water reactor fuel assembly can be part of a complete transmission assay measurement with high precision. Analysis of rows with up to 12 pins may also be feasible but with diminished precision. Preliminary data analysis of an NRTA simulation has demonstrated the simplicity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the Feasibility of Using Neutron Resonance Transmission Analysis (NRTA) for Assaying Plutonium in Spent Fuel Assemblies

Neutron resonance transmission analysis (NRTA) is an active-interrogation nondestructive assay (NDA) technique capable of assaying spent nuclear fuel to determine plutonium content. Prior experimental work has definitively shown the technique capable of assaying plutonium isotope composition in spent-fuel pins to a precision of approximately 3%, with a spatial resolution of a few millimeters. As a Grand Challenge to investigate NDA options for assaying spent fuel assemblies (SFAs) in the commercial fuel cycle, Idaho National Laboratory has explored the feasibility of using NRTA to assay plutonium in a whole SFA. The goal is to achieve a Pu assay precision of 1%. The NRTA technique uses low-energy neutrons from 0.1-40 eV, at the bottom end of the actinide-resonance range, in a time-of-flight arrangement. Isotopic composition is determined by relating absorption of the incident neutrons to the macroscopic cross-section of the actinides of interest in the material, and then using this information to determine the areal density of the isotopes in the SFA. The neutrons used for NRTA are produced using a pulsed, accelerator-based neutron source. Distinguishable resonances exist for both the plutonium (239,240,241,242Pu) and uranium (235,236,238U) isotopes of interest in spent fuel. Additionally, in this energy range resonances exists for six important fission products (99Tc, 103Rh, 131Xe, 133Cs, 145Nd, and 152Sm) which provide additional information to support spent fuel plutonium assay determinations. Based on extensive modeling of the problem using Monte Carlo-based simulation codes, our preliminary results suggest that by rotating an SFA to acquire four symmetric views, sufficient neutron transmission can be achieved to assay a SFA. In this approach multiple scan information for the same pins may also be unfolded to potentially allow the determination of plutonium for sub-regions of the assembly. For a 17 ? 17 pressurized water reactor SFA, a simplistic preliminary analysis indicates the mass of 239Pu may be determined with a precision on the order of 5%, without the need for operator-supplied fuel information or operational histories. This paper will present our work to date on this topic, indicate our preliminary findings for a conceptual assay approach, discuss resilience against spoofing, and outline our future plans for evaluating the NRTA technique for SFA plutonium determination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualification of JEFF3.1.1 library for high conversion reactor calculations using the ERASME/R experiment

With its low CO{sub 2} production, Nuclear Energy appears to be an efficient solution to the global warming due to green-house effect. However, current LWR reactors are poor uranium users and, pending the development of Fast Neutron Reactors, alternative concepts of PWR with higher conversion ratio (HCPWR) are being studied again at CEA, first studies dating from the middle 80's. In these French designs, low moderation ratio has been performed by tightening the lattice pitch, achieving a conversion ratio of 0.8-0.9 with a MOX fuel coming from PWR UOX recycling. Theses HCPWRs are characterized by a harder neutron spectrum and the calculation uncertainties on the fundamental neutronics parameters are increased by a factor 3 regarding a standard PWR lattice, due to the major contribution of the Plutonium isotopes and of the epithermal energy range to the reaction rates. In order to reduce these uncertainties, a 3-year experimental validation program called ERASME has been performed by CEA from 1984 to 1986 in the EOLE reactor. Monte Carlo analysis of the ERASME/R experiments with the Monte Carlo code TRIPOLI4 allowed the qualification of the recommended JEFF.3.1.1 library for major neutronics parameters. K{sub eff} of the MOX under-moderated lattice is over-predicted by 440 {+-} 830 pcm (2{sigma}); the conversion ratio, indicator of the good use of uranium, is also slightly over-predicted: 2 % {+-} 4 % (2{sigma}) and the same for B4C absorber rods worth and soluble boron worth, over-predicted by 2 %, both in the 2 standard deviations range. The radial fission maps of heterogeneities (water-holes, B4C and fertile rods) are well reproduced: maximal (C-E)/E dispersion is 1.3 %, maximal power peak error is 2.7 %. The void reactivity worth is the only parameter poorly calculated with an overprediction of +12.4% {+-} 1.5%. ERASME/R analysis of MOX reactivity, void effect and spectral indexes will contribute to the reevaluation of {sup 241}Am and Plutonium isotopes nuclear data for the next library JEFF3.2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Should WIPP Resume Unfiltered Discharge of Underground Ventilation?

On February 14, 2014 an incident in Panel 7, Room 7 of the Waste Isolation Pilot Plant (WIPP) underground repository resulted in the release of americium and plutonium (mostly {sup 241}Am) into the environment and contaminated portions of the repository primarily along the ventilation path from the location of the incident. The WIPP uses a ventilation system to ensure that underground air is circulated throughout the repository and to ensure that conditions are safe for the workers. Since the air in the repository exits to the surface through an exhaust shaft, this shaft is the sole potential pathway for airborne radioactivity release from the repository. During normal operations, exhaust air is released to the environment unfiltered. However, since the radiation release event, the WIPP ventilation system has been, and will likely remain in what is called 'filtration mode', (i.e., exhaust air is routed through a HEPA filter system). Redirection of the ventilation system through the HEPA (High Efficiency Particulate Air) filter system was necessary at the peak of the radiation release event to protect aboveground workers at the site and the public in the surrounding areas. However, evaluation of more than two years of underground ventilation sampling data indicates that residual radioactivity levels in the underground no longer warrant HEPA filtration in order to meet either worker or environmental protection criteria. WIPP should consider resumption of the unfiltered discharge of underground ventilation to the environment. Recent sampling data indicate that there have been no detectable releases that would have resulted in a hypothetical dose to a worker or a member of the public in excess of the 0.1 mSv (10 mrem) per year limit for periodic confirmatory sampling as required for operating repositories by the Environmental Protection Agency (40 CFR 191)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tonopah Test Range Air Monitoring: CY2018 Meteorological, Radiological, and Wind Transported Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Double Tracks site and Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to the Clean Slate sites and at the TTR Sandia National Laboratories (SNL) Range Operations Center (ROC). The primary objective of the monitoring effort is to support the DOE Environmental Management Nevada Program (EM NV) in the safe remediation of the environmental legacy of nuclear device development and testing by determining if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites, and to provide information for designing long-term monitoring of the sites. The monitoring program in 2018 included five stations. Station 400, located within TTR Area 3 and near the ROC, monitors conditions near the local workforce center. Stations 401 and 403 are located on the northern and southeastern perimeter fence lines, respectively, of the Clean Slate III site. Stations 404 and 405 are along the northern and eastern boundary fence, respectively, at Clean Slate II. The stations are generally downwind of the contaminated areas during either northwesterly or southerly winds, which are the predominant wind directions. The stations—which are similar in design to the Community Environmental Monitoring Program (CEMP) stations operating at locations surrounding the Nevada National Security Site and TTR—include meteorological instruments and continuous-flow, low-volume air samplers. Three pressurized ionization chambers for measuring gamma energy are in use at Stations 400, 401, and 403. Saltation sensors and saltation traps are deployed at the stations adjacent to the Clean Slate sites. Detailed meteorological data are recorded on data loggers, with periodic uploads via a satellite system to the Western Regional Climate Center (WRCC) at Desert Research Institute (DRI), to monitor instrument and site conditions. Air filter samples are collected every two weeks and the deposits in the saltation traps are collected when a sufficient sample mass for analysis has accumulated (generally a six- to eight-month interval). Monitoring at TTR in calendar year (CY) 2018 provided surveillance of both ambient conditions, and ground disturbance associated with remediation activities at Clean Slate II and III. The first half of CY2018 data from Stations 404 and 405 at Clean Slate II were collected during remediation activities at that site, and data collected during the final third of the year at Stations 401 and 403 at Clean Slate III coincided with remediation work at the site. Ambient conditions prevailed at Station 400 throughout the year. Dust transport by suspension and saltation is strongly dependent on wind speed. Concentrations of PM 10 (particulate matter of aerodynamic diameter ≤10 micrometers [μm], a size fraction of small particles that are suspended in the air and can be easily inhaled) remain low until winds exceed approximately 32 kilometers per hour (km/hr) (20 miles per hour [mph]). Saltation particle counts also increase above the same general threshold wind speed. Wind speeds in excess of 32 km/hr (20 mph) occur less than three percent of the time at the sites. Ground disturbing remediation activities were carried out at Clean Slate II from October 31, 2017, until July 26, 2018. Station 404 is located closest to the remediation area and is downwind of the area when winds are from the south. By late November, analysis of dust from the air sampler at Station 404 registered increases in plutonium-239+240 ( 239+240 Pu) concentrations. Peak plutonium concentrations, accompanied by elevated gross alpha concentrations and the detection of americium-241 ( 241 Am) by gamma spectroscopy, occurred between March and May 2018. During spring and early summer of 2018, elevated radionuclide concentrations were also measured in dust collected from the air sampler at Station 405, which is more than twice the distance from the remediation activity as Station 404. A minor but sustained increase in gross alpha concentration of suspended dust collected at Stations 400, 401, and 403 was also observed starting in May 2018 and continuing into August. Stations 401 and 403 are approximately 4.8 to 6.4 km (three to four miles) from Clean Slate II and Station 400 is approximately 13 km (eight miles) from that site. The radionuclide content of material that saltated into the passive Big Spring Number Eight (BSNE) traps during the Clean Slate II remediation period increased in both the traps facing toward and away from the fenced contamination area at Station 404, with the largest increases in concentration (almost five times the previous 239+240 Pu concentration) observed in the traps facing the fenced area. The radionuclide concentration in material in the trap facing away from the fence more than doubled from that measured in 2017. A similar increase was observed for the saltation trap facing away from the fenced area at Station 405, although no increase was observed for material captured in the trap facing the fenced area. Particles ranging in size from 50 to 500 µm generally move by saltation processes and are not expected to significantly contribute to dose for someone breathing in the standard respiratory zone for adult humans (1.5 to 1.7 m [4.9 to 5.6 ft] above ground level) because they are too large to be entrained in the air as suspended dust. Remediation activities at Clean Slate III began on September 5, 2018, and continued until a brief hiatus started on December 20, 2018. Although Station 401 is much closer to the remediation area than Station 403, the first increase in gross alpha and 239+240 Pu concentrations was noted in dust from filters collected at Station 403 in early November 2018. The highest radionuclide concentrations of 2018 at the Clean Slate III stations were recorded in air samples taken from Stations 401 and 403 in late December 2018 and these concentrations were comparable between the two station locations. Gamma rate data measured by the PICs was slightly higher than the annual average at Stations 401 and 403 after remediation activities began, but no single measurement was outside of the range observed in 2018 prior to remediation activities. No increase in radionuclide concentration was observed for the Clean Slate III remediation time period on air filters collected from the other stations. Radiological monitoring at Station 400—which is located at the ROC, and therefore the closest regularly staffed work location to the Clean Slate sites—recorded a higher mean gross alpha activity from dust collected on air sampler filters than in previous years. The individual biweekly air filters yielded measurements of gross alpha that were at or below the mean plus one standard deviation measured in CY2017, except for the period from April 25, 2018, through September 12, 2018. Nonetheless, gamma spectroscopy of all air filters from Station 400 identified only naturally occurring radionuclides, with no detection of americium-241 ( 241 Am) (which is used as an indicator of plutonium-241[ 241 Pu]). Alpha spectroscopy of selected air filters collected at Station 400 did not detect plutonium-238 ( 238 Pu) or 239+240 Pu above the analytical detection limit. Gross beta and gamma exposure rate data were comparable to data from regional CEMP stations. No saltation traps are deployed at Station 400. Considering the ambient monitoring periods during CY2018, the monitoring stations adjacent to the Clean Slate sites recorded above-background 238 Pu and 239+240 Pu concentrations (SNL, 1998; Turner et al., 2003) in samples collected by passive saltation traps and on selected air filters. These observations were consistent with previous years and indicated that radionuclide movement occurred under ambient conditions by processes of both saltation and suspension. The presence of radionuclides in all saltation traps, both upwind and downwind of the fenced contamination areas, was consistent with previous radiological survey results (EG&G, 1979) that show lower concentration radiologically contaminated material dispersed outside the fenced area. Although 239+240 Pu concentrations in the air filter samples were sometimes orders of magnitude higher than background, the concentrations were below risk-based action levels defined for an industrial area worker scenario (U.S. DOE, 2014). The interception of airborne dust with above-background radionuclide concentrations demonstrates that dispersal processes are continuing. Strong winds are the driver for both suspension and saltation of dust and soil. The recorded wind speed and PM10 during remediation activities at Clean Slate II and III identified discrete wind events lasting approximately five to eight hours each, which accounted for the greatest PM 10 concentrations at the monitoring stations. These events captured the effect of winds from the northwest and from the south. The observed differences in dust loading and radionuclide concentrations for the monitoring stations when they were either upwind or downwind of the contamination area identify the remediation area as a source of plutonium contaminated dust. The increase in concentration of radionuclides in airborne dust during the remediation activities, compared with measurements under previous ambient conditions (mean 239+240 Pu concentrations during remediation activities are approximately nine to 40 times higher compared to pre-remediation concentrations, depending on monitoring station), highlights the impact of land disturbance on wind-borne contaminant transport from the Clean Slate test areas. The meteorological and particulate matter monitoring indicated that conditions for wind-borne contaminant movement exist at the Clean Slate sites, and that transport of radionuclide-contaminated soil by both suspension and saltation occurred under ambient conditions and accelerated when the sites were disturbed. The 239+240 Pu alpha spectroscopy results indicated that airborne concentrations during remediation activities ranged from 2 × 10-16 to 380 × 10-16 µCi/ml. These results can be compared to the derived air concentration limit for 239 Pu of 6 × 10-11 µCi/ml for occupational workers contained in Code of Federal Regulations 10 CFR 835, Occupational Radiation Protection. Even though the air sampling results document an increase in concentration during remediation activities, the observed concentrations are less than 0.06 percent of the occupational limit. The Corrective Action Unit (CAU) closure strategy uses a risk-based approach, whereby acceptable contaminant concentrations are determined as a function of anticipated human exposure.

54 ENVIRONMENTAL SCIENCES↗

Neutron Resonance Transmission Analysis (NRTA): Initial Studies of a Method for Assaying Plutonium in Spent Fuel

Neutron Resonance Transmission Analysis (NRTA) is an analytical technique that uses neutrons to assay the isotopic content of bulk materials. The technique uses a pulsed accelerator to produce an intense, short pulse of neutrons in a time-of-flight configuration. These neutrons, traveling at different speeds according to their energy, can be used to interrogate a spent fuel (SF) assembly to determine its plutonium content. Neutron transmission through the assembly is monitored as a function of neutron energy (time after the pulse), similar to the way neutron cross-section data is often collected. The transmitted neutron intensity is recorded as a function of time, with faster (higher-energy) neutrons arriving first and slower (lower-energy) neutrons arriving later. The low-energy elastic scattering and absorption resonances of plutonium and other isotopes modulate the transmitted neutron spectrum. Plutonium content in SF can be determined by analyzing this attenuation. Work is currently underway at Idaho National Laboratory, as a part of United States Department of Energy's Next Generation Safeguards Initiative (NGSI), to investigate the NRTA technique and to assess its feasibility for quantifying the plutonium content in SF and for determining the diversion of SF pins from assemblies. Preliminary results indicate that NRTA has great potential for being able to assay intact SF assemblies. Operating in the 1-40 eV range, it can identify four plutonium isotopes (239, 240, 241, & 242Pu), three uranium isotopes (235, 236, & 238U), and six resonant fission products (99Tc, 103Rh, 131Xe, 133Cs, 145Nd, and 152Sm). It can determine the areal density or mass of these isotopes in single- or multiple-pin integral transmission scans. Further, multiple observables exist to allow the detection of material diversion (pin defects) including fast-neutron and x-ray radiography, gross-transmission neutron counting, plutonium resonance absorption analysis, and fission-product resonance absorption analysis. Initial benchmark modeling has shown excellent agreement with previously published experimental data for measurements of individual SF pins where plutonium assays were experimentally demonstrated to have a precision of better than 3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A priori precision estimation for neutron triples counting

The nondestructive assay of Plutonium bearing items for criticality, safety, security, safeguards, inventory balance, process control, waste management and compliance is often undertaken using correlated neutron counting. In particular Multiplicity Shift Register analysis allows one to extract autocorrelation parameters from the pulse train which can, within the framework of a simple interpretational model, be related to the effective {sup 240}Pu spontaneous fission mass present. The effective {sup 240}Pu mass is a weighted sum of the {sup 238}Pu, {sup 240}Pu and {sup 242}Pu masses so if the relative isotopic composition of the Pu can be established from the measured {sup 240}Pu effective mass one can estimate the total Pu mass and also the masses of the individual isotopes, example the fissile species {sup 239}Pu and {sup 241}Pu. In multiplicity counting three counting rates are obtained. These are the Singles, Doubles and Triples rates. The Singles rate is just the gross, totals or trigger rate. The Doubles and Triples rates are calculated from factorial moments of the observed signal triggered neutron multiplicity distributions following spontaneous fission in the item and can be thought of as the rate of observed coincident pairs and coincident triplets on the pulse train. Coincident events come about because the spontaneous fission and induced fission chains taking place in the item result in bursts of neutrons. These remain time correlated during the detection process and so retain information, through the burst size distribution, about the Pu content. In designing and assessing the performance of a detector system to meet a given goal it is necessary to make a priori estimates of the counting precision for all three kinds of rates. This is non-trivial because the counting does not obey the familiar rules of a Poissonian counting experiment because the pulse train has time correlated events on it and the train is sampled by event triggered gates that may overlap. For Singles and Doubles simple approximate analytical empirical rules for how to estimate the variance have been developed guided by theory and refined by experiment. However, for Triples no equivalent rules have been put forward and tested until now. In this work we propose an analytical expression, the CSH relation, for the variance on the Triples count and exercise it against experimental data gathered for Pu items measured in the Los Alamos National Laboratory's Epithermal Neutron Multiplicity Counter (ENMC). Preliminary results are encouraging and reasonable agreement with observation, considered fit for scoping studies, is obtained. We have also looked at the behavior using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recycle of Am-241 obtained from long term stored plutonium for use in radioisotope power systems - 15035

Pu-238 has been used as a power source for spacecraft since the early days of space exploration. It has proven to be an effective source of power where the use of solar generated power is impractical. Its application for use in spacecraft power systems was developed by the USA and Russia who have spent many $ 100s of millions on its development and production. However, the original facilities for the production of Pu-238 are no longer in use and existing worldwide stockpiles have reduced to levels sufficient for only one or two further missions. Production of Pu-238 requires considerable facilities including a nuclear reactor and reprocessing plants that are very expensive to build and operate. The European Space Agency (ESA) has assessed the options for post-launch power generation in future European space missions and has made the decision to pursue the use of Am-241 as an alternative isotope to power future European Radioisotope Power Systems (RPS). What makes Am-241 attractive for the European market is its 100% isotopically pure production from the decay of Pu-241 in separated civil plutonium stockpiles. Historically, Europe has relied on collaborations with the USA or Russia to access these nuclear power sources. During 2009, the European Space Agency (ESA) funded a project to examine the cost and practicality of establishing a European source of material suitable for Radioisotope Power Systems (RPS). The study concluded that a small number of radioisotopes could be used in RPSs. On further review two leading candidates, Am-241 and Pu-238, were selected for further study. Whilst Pu-238 was recognized as the isotope of choice for use in RPSs, the costs of setting up a European based production facility was prohibitively expensive. Although Am-241 has a number of limitations compared to Pu-238, the much reduced production costs make Am-241 an attractive option for European based production of RPSs. Despite its lower power density of ∼ 0.11 Wth/g, Am-241 is viewed as a potential alternative to Pu-238 because of its availability within the nuclear fuel cycle. During the reprocessing of spent nuclear fuel plutonium is separated as a chemically pure PuO{sub 2} product, containing around 3-11% w/w of the Pu-241 isotope, and placed into storage. During storage the Pu-241 isotope beta decays to Am-241 with a half-life of 14.4 years. {sub 94}{sup 241}Pu → (β 14.4 y) {sub 95}{sup 241}Am. This process has resulted in many 100 kgs of americium growing into the civil plutonium stockpile in the UK; material that is of value in generating heat sources and is able to be recycled. The key benefit of Am-241 as a potential European RPS source isotope is the availability of feed material along with the facilities to process it. It is expected that aged civil PuO{sub 2} will contain 25-50 g Am-241 per kg PuO{sub 2} depending on the source. A conceptual flowsheet using facilities for separating americium from plutonium is expected to produce on average 8.4 kg Am/year. ESA are now following their published road-map of studies to develop flight ready RTGs and RHUs. This has included the development and testing of the flowsheet to be used for production of Am-241. The project has focused on underpinning the conceptual flowsheet, using aged plutonium in NNL's PuMA laboratory. This has underpinned the design of a plant to produce a steady supply of Am-241. The scope of the overall project is 'store to store' - the starting point is aged plutonium currently housed in existing Sellafield stores and the end point is the storage of separated plutonium and americium powders on the Sellafield site. The full scale process is planned to be housed within the NNL's Central Laboratory in an existing facility designed for plutonium active operations. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Updated Reference VTR Core for CD-1

A preliminary reference core design was previously developed for the Versatile Test Reactor. The main features are that it is a 300 MW th sodium-cooled fast reactor using ternary metallic fuel U-20Pu-10Zr and able to achieve peak fast fluxes (E n > 0.1 MeV) in excess of 4.0x10 15 n/cm 2 -s. The plutonium in the fuel was assumed to be “reactor grade”, with a fissile quality of about 72% (i.e., 239 Pu and 241 Pu comprise 72% of the plutonium isotopes), and the uranium was assumed to be low-enriched uranium with 5% 235 U. This preliminary core design has been used through the CD-0 phase of the VTR project. Progression of the work after CD-0 led to revising, updating and refining the reference VTR core design, based on considerations from the various VTR teams: fuel, experiment, safety, and plant design teams. The objective of this report is to summarize the various changes made and details added to the model, to provide a description of the updated reference VTR core design and of its performance characteristics. This includes the traditional reactor physics characteristics, fuel cycle details, reactivity coefficients, temperature distributions, control rod worths and shutdown requirements. All of these define the updated “reference VTR core” intended to be used through CD-1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Approach in Fissile Assay Using LSDS - 17076

A quantitative assay of isotopic fissile materials (U{sup 235}, Pu{sup 239}, Pu{sup 241}) was conducted at the Korea Atomic Energy Research Institute (KAERI), using a lead slowing down spectrometer (LSDS). Using a uranium rod and plutonium, the actual measurement of induced fission neutrons was performed in the RPI (Rensselaer Polytechnic Institute) LSDS facility. In the simulation, a content of U{sup 235}, Pu{sup 239}, and Pu{sup 241} was changed. The detected signal has a direct relationship with the mass of the existing fissile isotopes. The mathematical model for fissile assay was applied to the measured and simulated detection data. The assay results show that the isotopic content was consistent with 2 to 3% uncertainty for Pu{sup 239}. The simulation indicated that the assay result was affected by the self-shielding correction. Usually, in highly enriched plutonium, the correction plays an important role and good understanding of it is required in order to increase assay accuracy. The combination of LSDS technique measurement and simulation is a very powerful and direct way to analyze the isotopic fissile content. The information provided by such analysis is applicable to nuclear fuel cycle development and spent fuel management for safety and economics. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Decontamination methods testing for the waste isolation pilot plant - 15691

On February 14, 2014, americium and plutonium contamination was released in the Waste Isolation Pilot Plant (WIPP) salt caverns. Several practical, easily deployable methods of decontaminating WIPP salt, using a surrogate contaminant and americium ({sup 241}Am), were developed and tested. The effectiveness of the methods is evaluated qualitatively, and to the extent practical, quantitatively. Of the methods tested (dry brushing, vacuum cleaning, water washing, strippable coatings, and mechanical grinding), the most practical seems to be water washing. Effectiveness is very high, and water washing is easy and rapid to deploy. The amount of wastewater produced (2 L/m{sup 2}) would be substantial and may not be easy to manage, but the method is the clear winner from a usability perspective. Removable surface contamination levels (smear results) from water washed coupons found no residual removable contamination. Thus, whatever contamination is left is likely adhered to (or trapped within) the salt. The other option that shows promise is the use of a fixative barrier. Bartlett Nuclear, Inc.'s Polymeric Barrier System proved the most durable of the coatings tested. The coatings were not tested for contaminant entrapment, only for coating integrity and durability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implications of Plutonium isotopic separation on closed fuel cycles and repository design

Advances in laser enrichment may enable relatively low-cost plutonium isotopic separation. This would have large impacts on LWR closed fuel cycles and waste management. If Pu-240 is removed before recycling plutonium as mixed oxide (MOX) fuel, it would dramatically reduce the buildup of higher plutonium isotopes, Americium, and Curium. Pu-240 is a fertile material and thus can be replaced by U-238. Eliminating the higher plutonium isotopes in MOX fuel increases the Doppler feedback, simplifies reactor control, and allows infinite recycle of MOX plutonium in LWRs. Eliminating fertile Pu-240 and Pu-242 reduces the plutonium content in MOX fuel and simplifies fabrication. Reducing production of Pu-241 reduces production of Am-241 - the primary heat generator in spent nuclear fuels after several decades. Reducing heat generating Am-241 would reduce repository cost and waste toxicity. Avoiding Am- 241 avoids its decay product Np-237, a nuclide that partly controls long-term oxidizing repository performance. Most of these benefits also apply to LWR plutonium recycled into fast reactors. There are benefits for plutonium isotopic separation in fast reactor fuel cycles (particularly removal of Pu-242) but the benefits are less. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements Conducted on an Unknown Object Labeled Pu-239

Measurements were carried out on 12 November 2013 to determine whether Pu-239 was present on an object discovered in a plastic bag with label “Pu-­239 6 uCi.” Following initial survey measurements to verify that the object was not leaking or contaminated, spectra were collected with a High Purity Germanium (HPGe) detector with object positioned in two different configurations. Analysis of the spectra did not yield any direct evidence of Pu-­239. From the measured spectra, minimum detectable activity (MDA) was determined to be approximately 2 uCi for the gamma-­ray measurements. Although there was no direct evidence of Pu-239, a peak at 60 keV characteristic of Am-­241 decay was observed. Since it is very likely that Am-­241 would be present in aged plutonium samples, this was interpreted as indirect evidence for the presence of plutonium on the object. Analysis of this peak led to an estimated Pu-­239 activity of 0.02–0.04 uCi, or <1x10 -6 grams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opportunities for the Multi Recycling of Used MOX Fuel in the US - 12122

Over the last 50 years the US has accumulated an inventory of used nuclear fuel (UNF) in the region of 64,000 metric tons in 2010, and adds an additional 2,200 metric tons each year from the current fleet of 104 Light Water Reactors. This paper considers a fuel cycle option that would be available for a future pilot U.S. recycling plant that could take advantage of the unique opportunities offered by the age and size of the large U.S. UNF inventory. For the purpose of this scenario, recycling of UNF must use the available reactor infrastructure, currently LWR's, and the main product of recycling is considered to be plutonium (Pu), recycled into MOX fuel for use in these reactors. Use of MOX fuels must provide the service (burn-up) expected by the reactor operator, with the required level of safety. To do so, the fissile material concentration (Pu-239, Pu-241) in the MOX must be high enough to maintain criticality, while, in current recycle facilities, the Pu-238 content has to be kept low enough to prevent excessive heat load, neutron emission, and neutron capture during recycle operations. In most countries, used MOX fuel (MOX UNF) is typically stored after one irradiation in an LWR, pending the development of the GEN IV reactors, since it is considered difficult to directly reuse the recycled MOX fuel in LWRs due to the degraded Pu fissile isotopic composition. In the US, it is possible to blend MOX UNF with LEUOx UNF from the large inventory, using the oldest UNF first. Blending at the ratio of about one MOX UNF assembly with 15 LEUOx UNF assemblies, would achieve a fissile plutonium concentration sufficient for reirradiation in new MOX fuel. The Pu-238 yield in the new fuel will be sufficiently low to meet current fuel fabrication standards. Therefore, it should be possible in the context of the US, for discharged MOX fuel to be recycled back into LWR's, using only technologies already industrially deployed worldwide. Building on that possibility, two scenarios are assessed where current US inventory is treated; Pu recycled in LWR MOX fuels, and used MOX fuels themselves are treated in a continuous partitioning-transmutation mode (case 2a) or until the whole current UNF inventory (64,000 MT in 2010) has been treated followed by disposal of the MOX UNF to a geologic repository (case 2b). In the recycling scenario, two cases (2a and 2b) are considered. Benefits achieved are compared with the once through scenario (case 1) where UNF in the current US inventory are disposed directly to a geologic repository. For each scenario, the heat load and radioactivity of the high activity wastes disposed to a geologic repository are calculated and the savings in natural resources quantified, and compared with the once-through fuel cycle. Assuming an initial pilot recycling facility with a capacity of 800 metric tons a year of heavy metal begins operation in 2030, ∼8 metric tons per year of Pu is recovered from the LEUOx UNF inventory, and is used to produce fresh MOX fuels. At a later time, additional treatment and recycling capacities are assumed to begin operation, to accommodate blending and recycling of used MOX Pu, up to 2,400 MT/yr treatment capacity to enable processing UNF slightly faster than the rate of generation. Results of this scenario analysis study show the flexibility of the recycling scenarios so that Pu is managed in a way that avoids accumulating used MOX fuels. If at some future date, the decision is made to dispose of the MOX UNF to a geologic repository (case 2b), the scenario is neutral to final repository heat load in comparison to the direct disposal of all UNF (case 1), while diminishing use of natural uranium, enrichment, UNF accumulation, and the volume of HLW. Further recycling of Pu at the end of the scenario (case 2a) would exhibit further benefits. As expected, Pu-241 and Am-241 are the source of long term HLW heat load and Am-241 and Np-237 are the source of long term radiotoxicity. When advanced technology is available, introduction of minor actinide recycling, in addition to Pu recycling, by the end of this scenario, or sooner, would have a major impact on final repository heat load and long term radiotoxicity of the HLW. This scenario is also compatible with a gradual introduction of a small number of FR's for Pu management. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New reference materials for trace-levels of actinide elements in plutonium

In this report two plutonium oxides were prepared as unique reference materials for measurement of actinide elements present as trace constituents. Each reference material unit is approximately 200 mg of PuO 2 powder in a quartz glass bottle. Characterized attributes of the oxides included mass fractions of plutonium, americium, neptunium, and uranium. Isotope-amount ratios were also determined for plutonium and uranium, but neptunium and americium were observed to be monoisotopic 237 Np and 241 Am. Measurements for characterization and verification of the attributes show that plutonium and trace actinides are homogeneous with the exception of limited heterogeneity for uranium, primarily observed for the 238 U isotope. Model purification ages calculated from measured americium and uranium attribute values are consistent with material histories and indicate that these impurities are predominantly due to the decay of plutonium isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Novel and Cost Effective Approach to the Decommissioning and Decontamination of Legacy Glove Boxes - Minimizing TRU Waste and Maximizing LLW Waste - 13634

This paper describes the process of decommissioning two gloveboxes at the Argonne National Laboratory (ANL) that were employed for work with plutonium and other radioactive materials. The decommissioning process involved an initial phase of clearing tools and materials from the glove boxes and disconnecting them from the laboratory infrastructure. The removed materials, assessed as Transuranic (TRU) waste, were packaged into 55 gallon (200 litre) drums and prepared for ultimate disposal at the Waste Isolation Pilot Plant (WIPP) at Carlsbad New Mexico. The boxes were then sampled to determine the radioactive contents by means of smears that were counted with alpha and beta detectors to determine the residual surface contamination, especially in terms of alpha particle emitters that are an indicator of TRU activity. Paint chip samples were also collected and sent for laboratory analysis in order to ascertain the radioactive contamination contributing to the TRU activity as a fixed contamination. The investigations predicted that it may be feasible to reduce the residual surface contamination and render the glovebox structure low level waste (LLW) for disposal. In order to reduce the TRU activity a comprehensive decontamination process was initiated using chemical compounds that are particularly effective for lifting and dissolving radionuclides that adhere to the inner surfaces of the gloveboxes. The result of the decontamination process was a reduction in the TRU surface activity on the inner surfaces of the gloveboxes by four orders of magnitude in terms of disintegrations per unit area (DPA). The next phase of the process involved a comprehensive assay of the gloveboxes using a combination of passive neutron and gamma ray scintillation detectors and a shielded and collimated high purity Germanium (HPGe) gamma ray detector. The HPGe detector was used to obtain gamma ray spectra for a variety of measurement positions within the glovebox. The spectra were used to determine the TRU content of the boxes by assessing the activity of Am-241 (59 keV) and Pu-241 (414 keV). Using the data generated it was possible for qualified subject matter experts (SME) to assess that the gloveboxes could be consigned for disposition as LLW and not as TRU. Once this determination was assessed and accepted the gloveboxes were prepared for final disposition to the Nevada National Security Site (NNSS) - formerly the Nevada Test Site (NTS). This preparation involved fixing any remaining radioactive contamination within the gloveboxes by filling them with a foam compound, prior to transportation. Once the remaining contamination was fixed the gloveboxes were removed from the laboratory and prepared for transported by road to NNSS. This successful glovebox decontamination and decommissioning process illustrates the means by which TRU waste generation has been minimized, LLW generation has been maximized, and risk has been effectively managed. The process minimizes the volume of TRU waste and reduced the decommissioning time with significant cost savings as the result. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗