Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLOTTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

MCL1 inhibition enhances the efficacy of docetaxel against airway-derived squamous cell carcinoma cells

Highlights: • Authentic squamous cell carcinoma (SqCC) cell lines of the lung are sparse. • HARA lung SqCC cells depend highly on MCL1 for survival in vitro and in vivo. • MCL1-silenced HARA cells decline in number upon docetaxel (DTX) exposure. • High MCL1 mRNA expression is linked with shorter survival in lung SqCC patients. • MCL1 depletion + DTX is highly effective against Detroit 562 pharyngeal SqCC cells. MCL1 is an anti-apoptotic BCL2 family member that is often overexpressed in various malignant tumors. However, few reports have described the role of MCL1 in squamous cell carcinoma (SqCC) derived from airways including the lung. In this study, we examined whether MCL1 could be a novel druggable target for airway-derived SqCC, for which effective molecular targeted drugs are unavailable. We searched the Kaplan–Meier Plotter database and found that high MCL1 mRNA expression was significantly associated with shorter survival in patients with lower airway (lung) or upper airway (head and neck) derived SqCC. We also explored the Expression Atlas database and learned that authentic lung SqCC cell lines expressing both TP63 and KRT5 mRNA were extremely sparse among the publicly available “lung SqCC cell lines”, with an exception being HARA cells. HARA cells were highly dependent on MCL1 for survival, and MCL1-depleted cells were not able to grow, and even declined in number, upon docetaxel (DTX) exposure in vitro and in vivo. Similar in vitro experimental findings, including those in a 3D culture model, were also obtained using Detroit 562 pharyngeal SqCC cells. These findings suggested that combined treatment with MCL1 silencing plus DTX appears highly effective against airway-derived SqCC.

60 APPLIED LIFE SCIENCES↗

l3d2vtk: An MCNPTools Utility to Enable LNK3DNT File Visualization & Post-Processing

This paper describes recent work to develop and incorporate a utility program into the MCNPTools package that enables LNK3DNT file visualization & post-processing. A LNK3DNT file is a binary Cartesian, cylindrical, or spherical structured mesh file that describes material and material relative density distributions by mesh voxel. This mesh file format is principally used by the PARTISN discrete-ordinates radiation-transport code. However, the MCNP ® Monte Carlo radiation-transport code can use LNK3DNT files to specify geometry, and the MCNP code can produce LNK3DNT files representing a user-defined region of the MCNP constructive solid geometry (CSG). Because of the use of LNK3DNT files as MCNP input and output and with other computer codes, improving the ability to visualize and/or quantitatively post-process LNK3DNT files benefits end users. In particular, it is helpful to visually verify that the material and density distributions are as expected. Also, an analyst can orient viewers with respect to other in formation, e.g., by co-plotting a voxelized representation of MCNP CSG with mesh tally and/or particle track results. However, until now, the only capability to interactively interrogate LNK3DNT files is through a 2-D slice plotter provided by the Monte Carlo Application ToolKit (MCATK), which is not currently distributed outside of Los Alamos National Laboratory. The utility created as part of this work converts LNK3DNT binary files to an ASCII XML-based StructuredMesh VTK (.vts) file. The geometries supported are 1-D spherical and cylindrical ( r ), 1-D Cartesian ( x ), 2-D cylindrical ( r-z and r-θ ) and Cartesian ( x-y ), and 3-D cylindrical ( r-z-θ ) and Cartesian ( x-y-z ). This file format is chosen to minimize external dependencies (e.g., on an HDF5 library) and to provide a file that can be interrogated by the user in a text editor or standard visualization applications (e.g., ParaView or VisIt). However, other file formats may provide more utility such as XDMF, which can use HDF5 and is discussed further as something to explore as future work. This paper is organized as follows: a brief introduc tion to the MCNPTools library and utility programs is given, the LNK3DNT-to-VTK (l3d2vtk) utility functionality is de scribed, and then an example post-processing workflow using the ParaView application is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In search of autophagy biomarkers in breast cancer: Receptor status and drug agnostic transcriptional changes during autophagy flux in cell lines

Autophagy drives drug resistance and drug-induced cancer cell cytotoxicity. Targeting the autophagy process could greatly improve chemotherapy outcomes. The discovery of specific inhibitors or activators has been hindered by challenges with reliably measuring autophagy levels in a clinical setting. We investigated drug-induced autophagy in breast cancer cell lines with differing ER/PR/Her2 receptor status by exposing them to known but divergent autophagy inducers each with a unique molecular target, tamoxifen, trastuzumab, bortezomib or rapamycin. Differential gene expression analysis from total RNA extracted during the earliest sign of autophagy flux showed both cell- and drug-specific changes. We analyzed the list of differentially expressed genes to find a common, cell- and drug-agnostic autophagy signature. Twelve mRNAs were significantly modulated by all the drugs and 11 were orthogonally verified with Q-RT-PCR (Klhl24, Hbp1, Crebrf, Ypel2, Fbxo32, Gdf15, Cdc25a, Ddit4, Psat1, Cd22, Ypel3). The drug agnostic mRNA signature was similarly induced by a mitochondrially targeted agent, MitoQ. In-silico analysis on the KM-plotter cancer database showed that the levels of these mRNAs are detectable in human samples and associated with breast cancer prognosis outcomes of Relapse-Free Survival in all patients (RSF), Overall Survival in all patients (OS), and Relapse-Free Survival in ER + Patients (RSF ER + ). High levels of Klhl24, Hbp1, Crebrf, Ypel2, CD22 and Ypel3 were correlated with better outcomes, whereas lower levels of Gdf15, Cdc25a, Ddit4 and Psat1 were associated with better prognosis in breast cancer patients. This gene signature uncovers candidate autophagy biomarkers that could be tested during preclinical and clinical studies to monitor the autophagy process.

60 APPLIED LIFE SCIENCES↗

Results of stainless steel canister corrosion studies and environmental sample investigations

This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of used nuclear fuel. The work involves both characterization of the potential physical and chemical environment on the surface of the storage canisters and how it might evolve through time, and testing to evaluate performance of the canister materials under anticipated storage conditions. To evaluate the potential environment on the surface of the canisters, SNL is working with the Electric Power Research Institute (EPRI) to collect and analyze dust samples from the surface of in-service SNF storage canisters. In FY 13, SNL analyzed samples from the Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI); here, results are presented for samples collected from two additional near-marine ISFSI sites, Hope Creek NJ, and Diablo Canyon CA. The Hope Creek site is located on the shores of the Delaware River within the tidal zone; the water is brackish and wave action is normally minor. The Diablo Canyon site is located on a rocky Pacific Ocean shoreline with breaking waves. Two types of samples were collected: SaltSmart™ samples, which leach the soluble salts from a known surface area of the canister, and dry pad samples, which collected a surface salt and dust using a swipe method with a mildly abrasive ScotchBrite™ pad. The dry samples were used to characterize the mineralogy and texture of the soluble and insoluble components in the dust via microanalytical techniques, including mapping X-ray Fluorescence spectroscopy and Scanning Electron Microscopy. For both Hope Creek and Diablo Canyon canisters, dust loadings were much higher on the flat upper surfaces of the canisters than on the vertical sides. Maximum dust sizes collected at both sites were slightly larger than 20 μm, but Phragmites grass seeds ~1 mm in size, were observed on the tops of the Hope Creek canisters. At both sites, the surface dust could be divided into fractions generated by manufacturing processes and by natural processes. The fraction from manufacturing processes consisted of variably-oxidized angular and spherical particles of stainless steel and iron, generated by machining and welding/cutting processes, respectively. Dust from natural sources consisted largely of detrital quartz and aluminosilicates (feldspars and clays) at both sites. At Hope Creek, soluble salts were dominated by sulfates and nitrates, mostly of calcium. Chloride was a trace component and the only chloride mineral observed by SEM was NaCl. Chloride surface loads measured by the Saltsmart™ sensors were very low, less than 60 mg m –2 on the canister top, and less than 10 mg m –2 on the canister sides. At Diablo Canyon, sea-salt aggregates of NaCl and Mg-SO 4 , with minor K and Ca, were abundant in the dust, in some cases dominating the observed dust assemblage. Measured Saltsmart™ chloride surface loads were very low (<5 mg m –2 ); however, high canister surface temperatures damaged the Saltsmart™ sensors, and, in view of the SEM observations of abundant sea-salts on the package surfaces, the measured surface loads may not be valid. Moreover, the more heavily-loaded canister tops at Diablo Canyon were not sampled with the Saltsmart™ sensors. The observed low surface loads do not preclude chloride-induced stress corrosion cracking (CISCC) at either site, because (1) the measured data may not be valid for the Diablo Canyon canisters; (2) the surface coverage was not complete (for instance, the 45º offset between the outlet and inlet vents means that near-inlet areas, likely to have heavier dust and salt loads, were not sampled); and (3) CISCC has been experimentally been observed at salt loads as low as 5-8 mg/m 2 . Experimental efforts at SNL to assess corrosion of interim storage canister materials include three tasks in FY14. First, a full-diameter canister mockup, made using materials and techniques identical to those used to make interim storage canisters, was designed and ordered from Ranor Inc., a cask vendor for Areva/TN. The mockup will be delivered prior to the end of FY14, and will be used for evaluating weld residual stresses and degrees of sensitization for typical interim storage canister welds. Following weld characterization, the mockup will be sectioned and provided to participating organizations for corrosion testing purposes. A test plan is being developed for these efforts. In a second task, experimental work was carried out to evaluate crevice corrosion of 304SS in the presence of limited reactants, as would be present on a dustcovered storage canister. This work tests the theory that limited salt loads will limit corrosion penetration over time, and is a continuation of work carried out in FY13. Laser confocal microscopy was utilized to assess the volume and depth of corrosion pits formed during the crevice corrosion tests. Results indicate that for the duration of the current experiments (100 days), no stifling of corrosion occurred due to limitations in the amount of reactants present at three different salt loadings. Finally, work has been carried out this year perfecting an instrument for depositing sea-salts onto metal surfaces for atmospheric corrosion testing purposes. The system uses an X-Y plotter system with a commercial airbrush, and deposition is monitored with a quartz crystal microbalance. The system is capable of depositing very even salt loadings, even at very low total deposition rates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

47 OTHER INSTRUMENTATION↗

CalTestBed - Parthian Energy: Electromagnetic Sensing of Pre-mature Cell Failure (CRADA Final Report)

We had lengthy discussions with Parthian on the interpretation of the original SOW as laid out in the original proposal and on whether or not these tasks were allowable under the rules set by Cal Test Bed. There were also discussions on program limitations on purchasing equipment. We were engaged with vendors identified by Parthian as companies from which we could lease equipment, and in most cases, came to find, that these products were only available for purchase. As a result, we configured translational stages into an x-y plotter arrangement and established computer control over the setup as a step toward building our own system for acquiring data to meet Parthian's requirements. The project reached its scheduled end prior to the start of testing and was allowed to elapse uncompleted.

25 ENERGY STORAGE↗

System for measuring roundness and concentricity of large tanks

Equipment measures the roundness and concentricity of large, massive tanks. The equipment includes a 34-foot rotary table, a variable reluctance displacement transducer, an electronics console, a digital computer, and a 5-foot plotter used for final data display.

Melton, R. E.↗

System remotely inspects, measures, and records internal irregularities in piping

Video electromechanical probe visually inspects and measures internal offset and peaking of welds in relatively large piping. Irregularity dimensions are recorded on peripheral equipment consisting of video tape and X-Y plotter. The probe is used for inspection of vacuum-jacketed liquid lines that cannot be inspected externally.

Burry, F. H.↗

Automated plotting of equipotentials

By substitution of resistance paper for normal plotting paper, an x-y plotter can be used to draw automatically the equipotential lines between components represented in planar form on the paper. This technique is used for high voltage electronic components of complex configuration for the prediction of stress in the intervening insulation.

Bunker, E. R., Jr.↗

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.↗

Lunar-Surface Closeup Stereoscopic Photography on the Sea of Tranquility (Apollo 11 Landing Site)

Analysis of returned lunar samples provides limited information about lunar geology. To obtain information about in-place lunar material, a closeup stereoscopic camera capable of photographing small-scale surface features was built and was used at the Apollo 11 landing site. Stereoscopic photographs were taken of surface areas relative to the lunar module, and the surfaces photographed were analyzed. The photographs are classified into five groups: soil disturbed by astronaut activities, generally undisturbed soil, loose aggregate surface material, crater bottoms with prominent glass deposits, and hard rock deposits. Glass deposits in the returned samples are described for comparison with the features observed in the photographs. The stereoscopic photographs were of outstanding quality and show the nature of lunar-surface material in detail. Lunar topography was reconstructed from the photographs with an analytical plotter. The photography results indicate that the closeup composition and genesis of lunar soil at the Apollo 11 landing site.

Greenwood, W. R.↗

Computer programs for plotting curves with various dashed-line sequences

Two FORTRAN-callable subprograms have been written to draw a smooth curve through a set of input points as a solid line or as a general sequence of long and short dashes. Subroutine LINSEQ draws conventional curves whereas subroutine CONSEQ draws smooth closed curves (contours). The subprograms are based on an approximate calculation of the arc length along the curve and spline interpolation along the arc length. Options are provided for smoothing of the input data and for offsetting the plotted curve from the input data points. The method of calculation of the arc length and the generation of the line sequence are described.Usage descriptions of the main subprograms, sample calling programs illustrating the various features of the subprograms, and sample plots are given. The subroutines should be readily adaptable to almost any computer-driven incremental plotter.

Desmarais, R. N.↗

Space shuttle: Aerodynamic characteristics of a composite booster/040A orbiter launch configuration with fin and booster body configuration effect contribution

An investigation was made of the fin configuration and booster body configuration effects on a composite booster/040A orbiter launch configuration. Aerodynamic performance and stability characteristics in pitch and yaw were obtained. Configurations tested included two stepped cylindrical bodies of different lengths with a conical nose, four fin shapes of various sizes and aspect ratios mounted in different positions around the base of the bodies, two base flare angles and three 040A orbiter configurations. The orbiter variations included a tailless configuration and two tail sizes. A tailless booster launch configuration with deflected petals (expanded flare sectors) was also tested. The model scale was 0.003366. Data were converted to coefficient form in near real time, punched on cards, and tabulated. The cards used in conjunction with a Benson-Lehner plotter were used to provide plotted data. At the end of the test, tabulated input forms were completed for the SADSAC computer program to aid in publishing the final test data report.

Ainsworth, R. W.↗

Photogrammetry of Apollo 15 photography, part C

In the Apollo 15 mission, a mapping camera system and a 61 cm optical bar, high resolution panoramic camera, as well as a laser altimeter were used. The panoramic camera is described, having several distortion sources, such as cylindrical shape of the negative film surface, the scanning action of the lens, the image motion compensator, and the spacecraft motion. Film products were processed on a specifically designed analytical plotter.

Wu, S. S. C.↗