Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutral beams for the burning plasma era: Simulations and modeling of deuterium ion beams for plasma heating (CRADA Final Report)

Together with Realta Fusion, we set up several simulation scenarios and ran simulations using the WarpX code which is developed by LBNL and especially by members of the LBNL team. We investigated beam transport and beam neutralization and ran optimization and benchmark simulations. To achieve this, several new features were added to the warpX code. These code additions will also be beneficial to other users of warpX including several fusion companies and researchers at National Laboratories. Furthermore, we supported Realta Fusion in setting up their own instances of WarpX. We presented our results at the American Physical Society Division of Plasma Physics meeting and are in the process of writing a publication that will be submitted to a peer-reviewed journal to share our results with the broader community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal Alfvén mode instability driven by plasma current in low-density Ohmic plasmas of the spherical tori

Due to intrinsically low magnetic fields, at low density the drift speed of the current-carrying electrons in spherical tokamaks can exceed fraction of the Alfvén speed sufficient for the excitation of the Alfvén gap modes. A particular case of the toroidal mode, observed during minor disruptions in Ohmic shots on SUNIST [Liu et al., Phys. Plasmas 23, 120706 (2016)], is considered in the present communication. Due to the negligible effect of the electron pressure gradient, the growth rate scales linearly with the drift speed, with slope inversely proportional to electron thermal velocity. In the absence of continuum damping, the threshold value of the drift speed for TAE excitation is independent of electron temperature.

Marchenko, V. S. (ORCID:0000000261480533)↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Toward the origins of binding energy shifts and “satellites” formation during plasma-XPS measurements

In-plasma x-ray photoelectron spectroscopy (plasma-XPS) emerges as a powerful platform for real-time, in situ chemical analysis under conditions relevant to semiconductor processing and other plasma-enabled technologies. This study investigates the origins of binding energy (BE) shifts and the formation of “satellite” peaks observed during plasma-XPS measurements across conductive, dielectric, and gas-phase systems. Using a standard laboratory-based ambient pressure XPS apparatus coupled with an alternating current (AC)-driven capacitively coupled plasma source, we demonstrate that metastable surface species, such as transient Au oxides, can be detected during plasma exposure, revealing chemical states that are hardly accessible using conventional ultrahigh vacuum (UHV) XPS. In dielectric samples (e.g., undoped diamond, sapphire), we observe pressure- and plasma-type-dependent BE shifts of more than 50 eV, attributed to x-ray-induced and plasma-mediated surface charging. These shifts are mitigated at higher pressures/plasmas or in electronegative plasmas (e.g., O 2 ), the latter due to enhanced charge compensation mechanisms involving slow negative ions. For gas-phase species, AC-plasma excitation leads to spectral broadening and the emergence of “satellite” peaks with energy separations of a few electron volts, linked to oscillating local plasma potentials in the probing volume. Furthermore, these findings highlight the complex and important interplay between plasma parameters, surface charging, and local electric fields in shaping XPS spectra. Overall, plasma-XPS emerges as a critical metrological tool for probing transient surface chemistry, with implications for semiconductor processing, material synthesis, and plasma diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of N 2 /O 2 plasma interaction with Pt-catalyst: effect of metastable adsorbates on product hysteresis

The coupling of catalysts and atmospheric-pressure plasma has the potential to improve the efficiency of certain catalytic reactions. Understanding the changes that the catalyst surface undergoes during exposure to plasma is key to improving plasma–catalytic performance. In this work, long term exposure of Pt–Al 2 O 3 powder catalyst to an Ar/N 2 /O 2 non-equilibrium atmospheric-pressure plasma-jet was investigated. Products produced by the interaction were analyzed downstream with Fourier-transform infrared spectroscopy while surface species were analyzed operandi with diffuse reflectance infrared Fourier transform spectroscopy. During exposure, the catalyst temperature was ramped cyclically between 100 °C and 350 °C to understand how substrate temperature affects the plasma–catalyst interaction. Long-lasting changes were revealed to take place on the catalyst surface during plasma exposure. At low temperatures, Pt–O and Pt–NO accumulate on the surface which react at elevated temperatures to form NO 2 . NO 2 initially appears to spill on to the Al 2 O 3 support as nitrites and nitrates instead of desorbing. Stable surface conditions are only achieved after prolonged plasma exposure, when nitrate sites on the Al 2 O 3 support are filled. By changing the catalyst temperature at various rates, the impact of total plasma species flux to the surface was analyzed. It was found that decreasing the heating rate increased the hysteresis in the pattern of NO 2 formation during thermal cycling. The variation with temperature demonstrates that plasma exposure results in a buildup of surface NO x and oxygen species which react or desorb at high temperatures. The observed changes are discussed from the generic viewpoint that a non-equilibrium plasma interacting with a catalyst at low temperature introduces metastable steady-state surface conditions. Upon heating above a threshold temperature, the introduced surface modifications can change either due to thermal effects, or, for a plasma environment, by additional interaction with the incident plasma species flux. The surface/material changes take place in a highly predictable fashion and after sufficient time above the threshold temperature reach a steady-state condition that is different from the transient behavior that is observed during initial heating. During cooling the plasma-surface interaction exhibits a different behavior than during heating, and this results in hysteresis of diverse observables. The metastability/hysteresis description appears quite generic and analogous to hysteresis behavior seen for different systems. Furthermore, it is expected to be useful for understanding the consequences of plasma–catalyst surface interactions for various systems.

36 MATERIALS SCIENCE↗

A hierarchal model for bacterial cell inactivation in solution by direct and indirect treatment using cold atmospheric plasmas

Cold atmospheric plasma devices have shown promise for a variety of plasma medical applications, including wound healing and bacterial inactivation often performed in liquids. In the latter application, plasma-produced reactive oxygen and nitrogen species (RONS) interact with and damage bacterial cells, though the exact mechanism by which cell damage occurs is unclear. Computational models can help elucidate relationships between plasma-produced RONS and cell killing by enabling direct comparison between dissimilar plasma devices and by examining the effects of changing operating parameters in these devices. In biological applications, computational models of plasma-liquid interactions would be most effective in design and optimization of plasma devices if there is a corresponding prediction of the biological outcome. In this work, we propose a hierarchal model for planktonic bacterial cell inactivation by plasma produced RONS in liquid. A previously developed reaction mechanism for plasma induced modification of cysteine was extended to provide a basis for cell killing by plasma-produced RONS. Results from the model are compared to literature values to provide proof of concept. Differences in time to bacterial inactivation as a function of plasma operating parameters including gas composition and plasma source configuration are discussed. Results indicate that optimizing gas-phase reactive nitrogen species production may be key in the design of plasma devices for disinfection.

59 BASIC BIOLOGICAL SCIENCES↗

Coupled Experimental/Computational Investigation of the Dynamics of Interacting Magnetized Plasmas

The interaction, or interpenetration, of magnetized plasmas of different density and/or pressure occurs in a wide variety of natural and man-made systems. Such systems include extragalactic jets propagating into the intergalactic medium, solar coronal mass ejections into background solar wind, compact toroid (CT) fueling of magnetic fusion plasmas, and jets of capsule shell impurities into DT fusion fuel, which can lead to enhanced impurity mix in inertial fusion implosions. These plasmas may take the form of jets, with open, helical magnetic structure, or plasma “bubbles” with closed magnetic fields (B-fields), such as spheromaks or CT’s. Such structures, both open and closed B-field cases, can transport heat, particles and magnetic flux or magnetic helicity into background plasma regions. For example, the origin of extragalactic magnetic fields may be due, at least in part, to transport by astrophysical jets. The goal of this proposed work was to elucidate the detailed plasma and magnetic field dynamics of high-density plasma jets (open B-field) and bubbles (closed B-field) propagating into lower density background magnetized plasma through controlled laboratory experiments and closely coupled nonlinear MHD modeling. These experiments were conducted in the HelCat (Helicon-Cathode) linear plasma device at the University of New Mexico (UNM). Plasma jets and bubbles were launched via an existing compact coaxial plasma gun, mounted on the HelCat device. This gun produced plasmas tens of cm in scale and lasting tens of microseconds, thereby allowing detailed multipoint, space- and time-resolved measurements to be made routinely. The experiments were directly modeled using the extended magnetohydrodynamic (XMHD) PERSEUS code, developed at Cornell University [23,24]. Both experimental and numerical modeling work are ongoing. The main results to date are reported here. Additional supplemental funding for one year (8/1/2019 – 7/31/2020) supported numerical investigation of photoionization processes important in many low temperature plasmas, including the HelCat device. Initial results of this modeling work is also reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient plasma-detachment events induced by multiple gas puffs in ADITYA-U tokamak

Application of periodic short bursts of gas leads to periodic separation of the plasma column edge from the limiter in the Ohmically heated discharges of ADITYA-U tokamak. After every gas-puff, injecting around 10 17 –10 18 m −3 molecules of fuel gas in the edge of the plasma column, a significant reduction in plasma density, temperature, H α emission intensity and an increase in the H β /H α ratio is observed in the vicinity of the limiter radius for a certain time duration before these parameters regain their pre-gas puff values. A decline in the ion-flux to the limiter is also observed simultaneously. The global confinement of plasma also increases after each gas-puff. These observations, which repeat after each gas-injection, imply that the plasma–neutral interaction occurs further away from the limiters after the gas-injection and indicate a periodic plasma separation from the limiter surface. Further investigation revealed that the gas-injection modifies the radial and toroidal electric field, which may be playing a role in the separation of the plasma column from the limiter surface. It was further demonstrated by an electrode bias experiment in the absence of gas-injection that an application of an external radial electric field can result in obtaining a separated plasma state.

Physics - Plasma physics↗

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology↗

Operando XPS in reactive plasmas: The importance of the wall reactions

In this article, advancements in differential pumping and electron optics over the past few decades have enabled x-ray photoelectron spectroscopy (XPS) measurements at (near-)ambient pressures, bridging the pressure gap for characterizing realistic sample chemistries. Recently, we have demonstrated the capabilities of an ambient pressure XPS setup for in situ plasma environment measurements, allowing plasma-surface interactions to be studied in operando rather than using the traditional before-and-after analysis approach. This new “plasma-XPS” technique facilitates the identification of reaction intermediates critical for understanding plasma-assisted surface processes relevant to semiconductor nanomanufacturing, such as physical vapor deposition, etching, atomic layer deposition, and many other plasma applications. In this paper, we apply the plasma-XPS approach to monitor real-time surface chemical changes on a model Ag(111) single crystal exposed to oxidizing and reducing plasmas. We correlate surface-sensitive data with concurrent gas-phase XPS measurements and residual gas mass-spectrum analysis of species generated during plasma exposure, highlighting the significant role of plasma-induced chamber wall reactions. Ultimately, we demonstrate that plasma-XPS provides comprehensive insights into both surface and gas-phase chemistry, establishing it as a versatile and dynamic characterization tool with broad applications in microelectronics research. Finally, we outline potential enhancements and future metrology directions to advance plasma-XPS investigations further.

36 MATERIALS SCIENCE↗

Validation of prediction capability of operating space for plasma initiation in MAST-U

DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗