Research on cold cathodes Second quarterly report, 14 Aug. - 14 Nov. 1965
GaP/tungsten and GaP/platinum diode and tungsten/barium oxide phototube fabrication and testing in cold cathode study
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
GaP/tungsten and GaP/platinum diode and tungsten/barium oxide phototube fabrication and testing in cold cathode study
Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.
The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.
We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons ($N_{\rm PE}$) given the known systematic errors on the simulation parameters. We compare results from four measurements of the $N_{\rm PE}$ determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of $0.0055\pm0.0009$ for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.
In this paper we consider an evolution of ideas in vacuum photodetector developments. Diverse approaches in developments of vacuum photodetectors (classical photomultipliers and hybrid phototubes) for the last half of century are covered. A particular emphasis is made on large area vacuum photodetectors developments. Some other issues concerning WLS and light guide techniques for increasing photodetectors sensitivity are highlighted as well.
This High Energy Physics research project achieved its goal of exploring high-energy interactions with 7, 8 and 13 TeV data accumulated by CMS at the Energy Frontier. For the original hadron calorimeter (HCAL) and for its upgrade during Long Shutdown 1 (LS1), the PI helped propose and implement the upgrading the phototubes, new electronics, and fast timing of the hadronic forward (HF) and hadronic outer (HO) calorimeters of CMS, projects which he had forcefully advocated since the inception of CMS. The PI and his colleagues Prof. J. Rohlf and chief electronics engineer E. Hazen, his post-docs A. Heister and S. Girgis, and his graduate students (P. Lawson and D. Arcaro) contributed software tools used in perfecting of μTCA and Advanced Mezzanine Card (AMC13) electronics, the PC board that provides clock, timing and DAQ service for HCAL (and now many other subdetectors and central systems in the upgraded CMS detector). This Task reaped the benefits of these hardware contributions 1) to hermiticity for missing energy searches, and 2) to forward tagging jets for Vector Boson Fusion processes by analyzing and publishing early data, including that for the Higgs discovery and for exotic and supersymmetric searches.
Understanding the origin of CP violation is currently one of the most forefront issues in elementary particle physics. Together with a better understanding of quark mixing and neutrino mixing phenomena, it is one of the central goals of particle physics, and has been pursued vigorously in many experiments. The very rare decay $K_L \to \pi ^0 v\bar{v}$ provides one of the best probes for understanding the original of CP violation in the quark sector. Particularly, theoretical uncertainties are very small in the Standard Model (SM) calculations, and the value therefore most suitable to be tested for beyond SM contributions. J-PARC E14 (also known as KOTO) aims to reach Standard Model sensitivity and beyond with Stage-1 and Stage-2. KOTO acquired 100 hours beam data in May 2013 and the result has been accepted for publication. From 2015-16, KOTO increased the data set by a factor of twenty, which will allow a limit to be set at the Grossman-Nir bound. This bound is valid in virtually any extension of the Standard Model. By comparing this model-independent bound and SM prediction, it is clear that there is considerable room for new physics. Analysis on these collected data sets shows neutron interactions which mimic the two-photon signal could become a potential background. To discriminate neutron background from the photon signal, one important tool, as shown in current data, is to perform detailed waveform analysis of the signal from the phototubes. To fully capture the calorimeter pulse shape with best fidelity from 100 out of the 2700 channels of CsI, we built the 500 MSPS (Mega Samples Per Second) with 14-bit digitizers. With KOTO Stage-2 currently in the planning stages, we started R&D work on a full width, but length scalable photon veto barrel detector with detailed layout of active detector elements.
In December 2010, the old British Phototube manufacture, EMI, called about their new product -after the company changed its name. The system they are marketing is very suitable for our use, digitizing charge from the detector in the beam line. Their system was capable of a large number of channels. Initially, we were offered a system based on integration with CCD readout. It is called the HE system. After many exchanges we bought a 64-channel system. It came pre assembled.
Application of gallium phosphide crystals for hot-electron cold cathode research - life tests for silver-barium oxide phototubes - surface film, semiconductor, and vacuum requirements
PAGEOS 1 and Echo 1 satellites tracked and photometrically analyzed in U-B-V spectral regions, describing phototubes, filters and Cassegrain reflecting telescope
Nonmechanical shutter utilizes nematic crystals to attenuate illumination, thus protecting light-sensitive devices such as vidicon or image orthicon tubes and phototubes. Opacity of liquid crystals is controlled by photosensor.
FITLOS is computer program which implements new curve fitting technique. Main program reads input data, calls appropriate subroutines for curve fitting, calculates statistical analysis, and writes output data. Method was devised as result of need to suppress noise in calibration of multiplier phototube capacitors.
An extremely accurate attitude determination was developed for space applications. This system uses a high sensitivity star sensor in which the photomultiplier tube is subject to noise generated by space radiations. The space radiation induced noise arises from trapped electrons, solar protons and other ionizing radiations, as well as from dim star background. The solar activity and hence the electron and proton environments are predicted through the end of the twentieth century. The available data for the response of the phototube to proton, electron, gamma ray, and bremsstrahlung radiations are reviewed and new experimental data is presented. A simulation was developed which represents the characteristics of the effect of radiations on the star sensor, including the non-stationarity of the backgrounds.
Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20 percent H 80 percent He correspond to theoretically predicted conditions.
A light-detection system for an optical radar, or lidar, unit to be used for remote temperature and composition measurements was designed, built, and bench tested. This detection system processes three return signal wavelengths: two Raman wavelengths, and the Rayleigh-Mie wavelength at 694.3 nanometers. Means of coping with photomultiplier tube instabilities and limitations are discussed. Circuits for gain control, ranging, and digitizing are included. The phototube gains can be switched fully on in 80 meters (450 nsec) or off in 30 meters (200 nsec) of range. The range circuit processes signals from 0.1 to 2 kilometers, with an estimated range resolution of less than 5 meters.
Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20% H2-80% He, at incident shock speeds of 12 to 14 km/sec and pressures of 66.6 to 133.3 N/sq m (0.5 to 1.0 mm Hg), correspond to theoretically predicted conditions. Immediately behind the incident shock at speeds of 17 to 24 km/sec the data indicate that the plasma reached equilibrium then demonstrated a drop in intensity which has been attributed to radiative cooling.
The power spectrum of phototube current from a laser Doppler velocimeter operating in the heterodyne mode has been computed. The spectrum is obtained in terms of the space time correlation function of the fluid. The spectral width and shape predicted by the theory are in agreement with experiment. For normal operating parameters the time average spectrum contains information only for times shorter than the Lagrangian integral time scale of the turbulence. To examine the long time behavior, one must use either extremely small scattering angles, much longer wavelength radiation or a different mode of signal analysis, e.g., FM detection.
The power spectrum of phototube current from a laser Doppler velocimeter operating in the heterodyne mode has been computed. The spectral width and shape predicted by the theory are in agreement with experiment. For normal operating parameters the time-average spectrum contains information only for times shorter than the Lagrangian-integral time scale of the turbulence. To examine the long-time behavior, one must use either extremely small scattering angles, much-longer-wavelength radiation, or a different mode of signal analysis, e.g., FM detection.