Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PHOTOMULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators

Beam Loss Assessment Through Use of Photomultiplier Tubes

The first machine in the Fermilab Accelerator chain, the Linac, delivers a 400 MeV proton beam. The first portion of the Fermilab Linac, the Drift Tube Linac, lacks the degree of instrumentation necessary for beam tuning. To compensate for this, photomultiplier tube (PMT s) based loss monitors were installed on either side of the first two drift tube tanks, but are not yet operational. One of the main goals in this is to make PMT's operational beam loss monitors for tuning. Noise reduction and peak finding on the PMT data is a requirement for this. A method for noise reduction and peak finding has been developed and implemented to produce a consistent and stable output. Future work includes integration with ACNET to automate input and output of data for analysis of beam loss.

Waggoner, Alexander

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]