Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOCATHODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Characterization of quantum well structures using a photocathode electron microscope

Present day integrated circuits pose a challenge to conventional electronic and mechanical test methods. Feature sizes in the submicron and nanometric regime require radical approaches in order to facilitate electrical contact to circuits and devices being tested. In addition, microwave operating frequencies require careful attention to distributed effects when considering the electrical signal paths within and external to the device under test. An alternative testing approach which combines the best of electrical and optical time domain testing is presented, namely photocathode electron microscope quantitative voltage contrast (PEMQVC).

Spencer, Michael G.↗

Lightweight, High-Yield Photocathode

Layer of Astroquartz (or equivalent) cloth woven from quartz thread multiplies electron current emitted by aluminum photocathode sensitive to ultraviolet light when placed in external steady-state electric field. Desirable in applications where low power consumption required.

Leung, Philip L.↗

Results From Cs Activated GaN Photocathode Development for MCP Detector Systems at GSFC

We describe the development of high quantum efficiency W photocathodes for use in large area two dimensional microchannel plate based detector arrays to enable new W space astronomy missions. Future W missions will require improvements in detector sensitivity, which has the most leverage for cost-effective improvements in overall telescope/instrument sensitivity. We use new materials such as p-doped GaN, AIGaN, ZnMgO, Sic and diamond. We have currently obtained QE values > 40 % at 185 nm with Cesiated GaN, and hope to demonstrate higher values in the future. By using controlled internal fields and nano-structuring of the surfaces, we plan to provide field emission assistance for photoelectrons while maintaining their energy distinction from dark noise electrons. We will transfer these methods from GaN to ZnMgO, a new family of wide band-gap materials more compatible with microchannel plates. We also are exploring technical parameters such as doping profiles, internal and external field strengths, angle of incidence, field emission assistance, surface preparation, etc.

Norton, Tim↗

Piezoelectrically enhanced photocathode

A photocathode, for generating electrons in response to incident photons in a photodetector, includes a base layer having a first lattice structure and an active layer having a second lattice structure and epitaxially formed on the base layer, the first and second lattice structures being sufficiently different to create a strain in the active layer with a corresponding piezoelectrically induced polarization field in the active layer, the active layer having a band gap energy corresponding to a desired photon energy.

Beach, Robert A.↗

Silicon/Carbon Nanotube Photocathode for Splitting Water

A proof-of-concept device is being developed for hydrogen gas production based on water-splitting redox reactions facilitated by cobalt tetra-aryl porphyrins (Co[TArP]) catalysts stacked on carbon nanotubes (CNTs) that are grown on n-doped silicon substrates. The operational principle of the proposed device is based on conversion of photoelectron energy from sunlight into chemical energy, which at a later point, can be turned into electrical and mechanical power. The proposed device will consist of a degenerately n-doped silicon substrate with Si posts covering the surface of a 4-in. (approximately equal to 10cm) wafer. The substrate will absorb radiation, and electrons will move radially out of Si to CNT. Si posts are designed such that the diameters are small enough to allow considerable numbers of electrons to transport across to the CNT layer. CNTs will be grown on top of Si using conformal catalyst (Fe/Ni) deposition over a thin alumina barrier layer. Both metallic and semiconducting CNT will be used in this investigation, thus allowing for additional charge generation from CNT in the IR region. Si post top surfaces will be masked from catalyst deposition so as to prevent CNT growth on the top surface. A typical unit cell will then consist of a Si post covered with CNT, providing enhanced surface area for the catalyst. The device will then be dipped into a solution of Co[TArP] to enable coating of CNT with Co(P). The Si/CNT/Co [TArP] assembly then will provide electrons for water splitting and hydrogen gas production. A potential of 1.23 V is needed to split water, and near ideal band gap is approximately 1.4 eV. The combination of doped Si/CNT/Co [TArP] will enable this redox reaction to be more efficient.

Amashukeli, Xenia↗

Further developments of electrographic image detectors

This paper reports the current status of a program to develop far- and middle-ultraviolet-sensitive electrographic detectors. These include large-format, semitransparent-photocathode detectors and opaque-photocathode electrographic Schmidt cameras. Modifications of a previously-demonstrated far-UV large-format detector to make it suitable for possible Shuttle/Spacelab space astronomy investigations have been implemented and tested. Middle-ultraviolet-sensitive large-format and Schmidt electrographic detectors are now in the laboratory development stage. Cesium telluride photocathodes are used to provide sensitivity in the 1700-3100 A spectral range, and techniques for processing these photocathodes are discussed. The preparation and use of polyimide barrier membranes, for protecting the photocathodes from deterioration by film outgassing, are described. A new opaque-photocathode vacuum-ultraviolet-sensitive electrographic detector has been demonstrated, which is based on an oblique-focusing electron optical system similar to that used by Princeton with electron-bombarded CCD arrays. Test results and potential applications of this detector are described.

Carruthers, G. R.↗

Image tube

An optical image is projected onto a planar surface of a photocathode that derives an electron beam replica of the image. A target electrode displaced relative to the photocathode so that it does not obstruct the optical image includes a planar surface for receiving and deriving an accurate replica of the electron beam image. The two planar surfaces are parallel. The electron beam image is focused on the target electrode by providing throughout a region that extends between the planar surfaces of the photocathode and receiving electrode, constant homogeneous dc electric and magnetic fields. The electric field extends in a direction perpendicular to the planar surfaces while the magnetic field extends along a straight line that intersects the photocathode and target electrode at an acute angle.

Hallam, K. L.↗

Refractive field correctors for the Starlab ultraviolet telescope

Field correctors for a one-meter, f/15 cassegrainian telescope were designed as part of a NASA-funded study of an astronomical obervatory on board of the Space Shuttle. By means of a Gasgoigne corrector and a biconcave field flattener, astigmatism and field curvature are corrected in a 0.6 deg field. Applicable wavelength ranges are limited by chromatic aberrations. The upper wavelength is selected to match a photocathode response limit. The lower wavelength limit is defined by a filter. Examples of usable wavelength ranges are: 210 nm - 1100 nm (multialkali photocathode, fused-silica corrector elements), 177 nm - 320 nm (cesium telluride photocathode, calcium fluoride correctors); and possibly 134 nm - 190 nm (cesium iodide photocathode, lithium fluoride correctors). Residual rms lateral color is smaller than 0.02 arc sec, and axial color is smaller than 0.25 arc sec (blur diameter at the ends of the wavelength range). The correctors introduce a small amount of coma. This is compensated by adjustment of the conic constants of the telescope mirrors.

Bottema, M.↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

Near-Infrared Photon-Counting Camera for High-Sensitivity Observations

The dark current of a transferred-electron photocathode with an InGaAs absorber, responsive over the 0.9-to-1.7- micron range, must be reduced to an ultralow level suitable for low signal spectral astrophysical measurements by lowering the temperature of the sensor incorporating the cathode. However, photocathode quantum efficiency (QE) is known to reduce to zero at such low temperatures. Moreover, it has not been demonstrated that the target dark current can be reached at any temperature using existing photocathodes. Changes in the transferred-electron photocathode epistructure (with an In- GaAs absorber lattice-matched to InP and exhibiting responsivity over the 0.9- to-1.7- m range) and fabrication processes were developed and implemented that resulted in a demonstrated >13x reduction in dark current at -40 C while retaining >95% of the approximately equal to 25% saturated room-temperature QE. Further testing at lower temperature is needed to confirm a >25 C predicted reduction in cooling required to achieve an ultralow dark-current target suitable for faint spectral astronomical observations that are not otherwise possible. This reduction in dark current makes it possible to increase the integration time of the imaging sensor, thus enabling a much higher near-infrared (NIR) sensitivity than is possible with current technology. As a result, extremely faint phenomena and NIR signals emitted from distant celestial objects can be now observed and imaged (such as the dynamics of redshifting galaxies, and spectral measurements on extra-solar planets in search of water and bio-markers) that were not previously possible. In addition, the enhanced NIR sensitivity also directly benefits other NIR imaging applications, including drug and bomb detection, stand-off detection of improvised explosive devices (IED's), Raman spectroscopy and microscopy for life/physical science applications, and semiconductor product defect detection.

Jurkovic, Michael↗

The oblique electron lens.

An oblique electron lens is described that is especially applicable to image converters and camera tubes employing flat opaque photocathodes. The use of optical lenses, corrector plates, and/or mirrors (often employed in other electron lenses designed for use with opaque photocathodes) are eliminated. The oblique electron lens is well suited to ultraviolet and vacuum ultraviolet image converters, and to image converters employing opaque negative electron affinity photocathodes. It is also possible to use this oblique electron lens for electronography. Measurements on an experimental tube show that a limiting resolution of 50 line pairs/mm is possible, but the intrinsic lens quality is believed to approach that of a conventional electromagnetic lens having uniform and colinear electric and magnetic fields.

Johnson, C. B.↗

SEC vidicon testing

Results obtained from several basic measurements of the performance of an SEC vidicon camera head are presented. The measurements or tests are patterned around the sensor requirements which exist for a rapid response coronagraph. Following a brief description of the SEC vidicon camera head, test set-up, and operating procedures, results are presented for five basic tests. These tests include: (1) Input-output, or transfer, characteristics; (2) modulation transfer function; (3) signal-to-noise ratio; (4) photocathode sensitivity; and (5) target gain. The input-output characteristics and photocathode sensitivity measurements were obtained for three bandpasses centered about 4000, 5250, and 6200 A. Results are also given for the variation of photocathode sensitivity with position on the cathode surface.

Johnson, D. S., Jr.↗

Evaluation of the amperex 56 TVP photomultiplier

Characteristics were measured for the Amperex 56 TVP 42 mm-diameter photomultiplier. Some typical photomultiplier characteristics-such as gain, dark current, transit and rise times-are compared with data provided. Photomultiplier characteristics generally not available such as the single photoelectron time spread, the relative collection efficiency, the relative anode pulse amplitude as a function of the voltage between the photocathode and focusing electrode, and the position of the photocathode sensing area were measured and are discussed for two 56 TVP's. The single photoelectron time spread, the relative collection efficiency, and the transit time difference as a function of the voltage between photocathode and focusing electrode were also measured and are discussed, particularly with respect to the optimization of photomultiplier operating conditions for timing applications.

Lo, C. C.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗