Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PDD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-F-T-551: Beam Hardening and Attenuation of Photon Beams Using Integral Quality Monitor in Radiotherapy

Purpose: Aim of the multi-centre study was to analyse beam hardening effect of the Integral Quality Monitor (IQM) for high energy photon beams used in radiotherapy with linear accelerators. Generic values for attenuation coefficient k(IQM) of IQM system were additionally investigated. Methods: Beam hardening effect of the IQM system was studied for a set of standard nominal photon energies (6 MV–18 MV) and two flattening filter free (FFF) energies (6 MV FFF and 10 MV FFF). PDD curves were measured and analysed for various square radiation fields, with and without IQM in place. Differences between PDD curves were statistically analysed through comparison of respective PDD-20,10 values. Attenuation coefficients k(IQM) were determined for the same range of photon energies. Results: Statistically significant differences in beam qualities for all evaluated high energy photon beams were found, comparing PDD-20,10 values derived from PDD curves with and without IQM in place. Significance of beam hardening effect was statistically proven with high confidence (p < 0,01) for all analysed photon beams except for 15 MV (p = 0,078), although relative differences in beam qualities were minimal, ranging from 0,1 % to 0,5 %. Attenuation of the IQM system showed negligible dependence on radiation field size. However, clinically important dependence of kIQM versus TPRs20,10 was found: 0,941 for 6 MV photon beams, to 0,959 for 18 MV photon beams, with highest uncertainty below 0,006. k(IQM) versus TPRs were tabulated and polynomial equation for the determination of k(IQM) is suggested for clinical use. Conclusion: There was no clinically relevant beam hardening, when IQM system was on linear accelerators. Consequently, no additional commissioning is needed for the IQM system regarding the determination of beam qualities. Generic values for k(IQM) are proposed and can be used as tray factors for complete range of examined photon beam energies.

60 APPLIED LIFE SCIENCES↗

Dosimetry of a Small Air Cavity for Clinical Electron Beams: A Monte Carlo Study

This study investigated dosimetric changes in a water phantom when a small air cavity was presented at the central axis of a clinical electron beam. We used 6-, 9-, and 16-MeV electron beams with a 10 x 10 cm{sup 2} applicator and cutout produced by a Varian 21 EX linear accelerator. Percentage depth doses (PDDs) for different depths (0.5-7 cm), thicknesses (2-10 mm), and widths (1-5 cm) of air cavities were calculated using Monte Carlo simulations (EGSnrc code) validated by film measurements. By comparing PDDs of phantoms with and without the air cavity, it was found that when the depth or thickness of cavity was changed, the PDD curve below the cavity was shifted with a distance equal to the thickness of the cavity. However, when the width of the air cavity was changed, both the PDD curve and its slope within and below the cavity were changed. A larger width of the air cavity resulted in a shallower PDD curve within the cavity. The slope of the PDD curve below the cavity tended towards a value as the width of the air cavity was increased to 3-5 cm for the 6-, 9-, and 16-MeV electron beams. The dependence of the depth dose on the width of the air cavity is a result of the contribution of the electron side scattering in the water surrounding the cavity. The change in depth dose resulting from the presence of an air cavity can cause discrepancies between the calculated and actual dose during radiotherapy, unless the effects of the air cavity are properly characterized during treatment planning. From the dosimetry data in this study, neglecting an air cavity of 1-cm thickness in the build-up region of a 6-MeV electron beam resulted in a delivered dose 10-12% larger than the original prescription. Delivered doses 3% and 6% higher than the prescribed dose were observed when doses were prescribed at R{sub 80} for a 16-MeV electron beam. These results were obtained by neglecting air cavities with thicknesses equal to 2 and 4 mm, respectively, at a depth of 5 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

High resolution (1 km) positive degree-day modelling of Greenland ice sheet surface mass balance, 1870–2012 using reanalysis data

Here, we show results from a positive degree-day (PDD) model of Greenland ice sheet (GrIS) surface mass balance (SMB), 1870–2012, forced with reanalysis data. The model includes an improved daily temperature parameterization as compared with a previous version and is run at 1 km rather than 5 km resolution. The improvements lead overall to higher SMB with the same forcing data. We also compare our model with results from two regional climate models (RCMs). While there is good qualitative agreement between our PDD model and the RCMs, it usually results in lower precipitation and lower runoff but approximately equivalent SMB: mean 1979–2012 SMB (± standard deviation), in Gt a –1 , is 382 ± 78 in the PDD model, compared with 379 ± 101 and 425 ± 90 for the RCMs. Comparison with in situ SMB observations suggests that the RCMs may be more accurate than PDD at local level, in some areas, although the latter generally compares well. Dividing the GrIS into seven drainage basins we show that SMB has decreased sharply in all regions since 2000. Finally we show correlation between runoff close to two calving glaciers and either calving front retreat or calving flux, this being most noticeable from the mid-1990s.

54 ENVIRONMENTAL SCIENCES↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

The effect of laser spot shapes on polar-direct-drive implosions on the National Ignition Facility

Ongoing polar-direct-drive (PDD) implosions on the National Ignition Facility (NIF) [J. D. Lindl and E. I. Moses, Phys. Plasmas 18, 050901 (2011)] use existing NIF hardware, including indirect-drive phase plates. This limits the performance achievable in these implosions. Spot shapes are identified that significantly improve the uniformity of PDD NIF implosions; outer surface deviation is reduced by a factor of 7 at the end of the laser pulse and hot-spot distortion is reduced by a factor of 2 when the shell has converged by a factor of ∼10. As a result, the neutron yield increases by approximately a factor of 2. This set of laser spot shapes is a combination of circular and elliptical spots, along with elliptical spot shapes modulated by an additional higher-intensity ellipse offset from the center of the beam. This combination is motivated in this paper. It is also found that this improved implosion uniformity is obtained independent of the heat conduction model. This work indicates that significant improvement in performance can be obtained robustly with the proposed spot shapes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-601: Output Factor Calculation of Irregular Shape Electron Cutout at Extended SSD

Purpose: To calculate the output factor of irregular shape electron beam at extended SSD using modified lateral build-up-ratio method. Methods: Circular cutouts from 2.0cm diameter to maximum possible sizes were prepared for applicator cone size of 15×15cm. In addition, different irregular cutouts were prepared. Percentage depth dose (PDD) curves were measured for each cutout using 6, 9, 12 and 16-MeV at the standard SSD of 100cm. The scanning was done using Multidata system and Scanditronix diodes on 2100SC Varian LINAC. In addition, for each cutout and electron beam energy doses were measured at SSD values of 100, 105, 110, 115cm using EDR2 films and diodes. Results: The measured PDD were normalized to the depth of 1.0mm. The lateral build-up-ratio (LBR) and the lateral scatter parameter (sigma) were calculated for each circular cutout using the open 15X15-cm2 field as the reference field. Taking the linear increase of sigma with cutout size into account, PDD of the irregular cutouts were calculated at 100 cm SSD. Furthermore, using the dose measured at different SSDs, the effective SSD value for each circular cutout and electron beam energy was determined. Employing the LBR and the effective-SSD values of the circular cutouts along with the calculated PDD of the irregular cutouts, the output factors of the irregular cutout at different extended SSD values were calculated. Finally, the calculated output factors were compared with the measured values. Conclusion: In this research, it is shown that output factor of irregular shape electron beam at extended SSD can be determined by using the LBR and the effective SSD values of circular cutouts. The percentage difference of the calculated output factor from the measured output factor for irregular cutouts at extended SSD were within 3.0%.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-75: A Simple Technique for Proton Beam Range Verification

Purpose: To develop a measurement-based technique to verify the range of proton beams for quality assurance (QA). Methods: We developed a simple technique to verify the proton beam range with in-house fabricated devices. Two separate devices were fabricated; a clear acrylic rectangular cuboid and a solid polyvinyl chloride (PVC) step wedge. For efficiency in our clinic, we used the rectangular cuboid for double scattering (DS) beams and the step wedge for pencil beam scanning (PBS) beams. These devices were added to our QA phantom to measure dose points along the distal fall-off region (between 80% and 20%) in addition to dose at mid-SOBP (spread out Bragg peak) using a two-dimensional parallel plate chamber array (MatriXX™, IBA Dosimetry, Schwarzenbruck, Germany). This method relies on the fact that the slope of the distal fall-off is linear and does not vary with small changes in energy. Using a multi-layer ionization chamber (Zebra™, IBA Dosimetry), percent depth dose (PDD) curves were measured for our standard daily QA beams. The range (energy) for each beam was then varied (i.e. ±2mm and ±5mm) and additional PDD curves were measured. The distal fall-off of all PDD curves was fit to a linear equation. The distal fall-off measured dose for a particular beam was used in our linear equation to determine the beam range. Results: The linear fit of the fall-off region for the PDD curves, when varying the range by a few millimeters for a specific QA beam, yielded identical slopes. The calculated range based on measured point dose(s) in the fall-off region using the slope resulted in agreement of ±1mm of the expected beam range. Conclusion: We developed a simple technique for accurately verifying the beam range for proton therapy QA programs.

60 APPLIED LIFE SCIENCES↗

SU-E-T-390: Evaluation of Heterogeneity Corrections Made by RayStation Treatment Planning

Purpose: To examine the agreement between absorbed doses calculated by RayStation treatment planning algorithm to those measured with gafchromic film and ion chamber when the photon beam is perturbed by attenuation or lateral scatter of lung material. Methods: A gafchromic EBT2 film was placed in the center of a 30×30×20 cm{sup 3} solid water phantom with a 5 cm lung slab placed at 10 cm depth. The film was irradiated at SSD = 100 cm with a 6 MV photon beam, 10×10 and 5×5 cm{sup 2} field sizes and with the beam parallel to the film and lung slab. A CT was performed to the phantom arrangement for RayStation dose calculation. The films were scanned in an Epson 10000X flatbed scanner and analyzed using the red channel, 16 bits, 76 dpi. PDD curves at the central axis and profiles at dmax were also measured in water using a CC13 (0.13 CC) ion chamber. Measurements and calculation of PDD curves at the central axis and profiles at dmax and 20 cm depth were compared using the criteria suggested by the AAPM Task Group # 53. Results: The PDD curves measured with gafchromic film and those measured in water with ion chamber agree with the ones calculated by RayStation within the uncertainty of the measurements which is within 3%. The passing rate values of the measured and calculated profiles for the 2 field sizes are within 94% for both at dmax and at 20 cm depth. Conclusion: Raystation dose calculation engine models inhomogeneity corrections. Differences between the calculated PDD curves and profiles and those measured with gafchromic film are within the uncertainty of the measurements and inside of the agreement tolerance suggested by TG53. Therefore, RayStation treatment planning has an acceptable algorithm to correct dose delivered by photon beams perturbed by lung tissue.

60 APPLIED LIFE SCIENCES↗

SU-E-T-665: Radiochromic Film Quenching Effect Reduction for Proton Beam Dosimetry

Purpose: Depending on the useful dose range in which radiochromic films operate, number of different radiochromic film models have been designed. The impact of different film models on quenching effect for percent depth dose (PDD) measurements in proton beams has been investigated. Methods: Calibrated PTW Markus ionization chamber was used to measure PDD and beam output for 26.5 MeV protons produced by CS30 cyclotron. An aluminum cylinder was added in front of the beam exit serving as a radiation shutter. The measured signal was normalized to a monitor chamber reading and subsequently scaled by ratio of water-to-air stopping powers at given depth, while the effective depth of measurements was scaled by ratios of material-to-water physical densities and CSDA ranges. Output was measured in water at 2.1 mm reference-depth in the plateau upstream from the Bragg peak. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water. Three radiochromic film models (EBT, EBT3 and HD-V2) were calibrated within Lexan phantom positioned at the same water-equivalent depth. Thicknesses of films sensitive layers were 34 µm, 30 µm and 8 µm, respectively. Small film pieces (1 x 2 cm{sup 2}) were positioned within polyethylene phantom along the beam central axis with an angulation of 5° for PDD measurements. Results: While the output of the proton beam was found to be around 7 Gy/sec, the actual value of the output per monitor chamber reading (2.32 Gy/nC) was used for reference-dose irradiations during film calibration. Dose ratios at the Bragg peak relative to the reference-depth were 3.88, 2.52, 2.19, and 2.02 for the Markus chamber, HD-V2, EBT3, and EBT film models, respectively. Conclusion: Results at hand suggest that quenching effect is reduced when a radiochromic film model with smaller sensitive layer thickness is used for PDD measurements in proton beams. David Lewis is the owner of RCF Consulting, LLC.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-78: Minimum Data Set of Measurements for TG 71 Based Electron Monitor-Unit Calculations

Purpose: Building up a TG-71 based electron monitor-unit (MU) calculation protocol usually involves massive measurements. This work investigates a minimum data set of measurements and its calculation accuracy and measurement time. Methods: For 6, 9, 12, 16, and 20 MeV of our Varian Clinac-Series linear accelerators, the complete measurements were performed at different depth using 5 square applicators (6, 10, 15, 20 and 25 cm) with different cutouts (2, 3, 4, 6, 10, 15 and 20 cm up to applicator size) for 5 different SSD’s. For each energy, there were 8 PDD scans and 150 point measurements for applicator factors, cutout factors and effective SSDs that were then converted to air-gap factors for SSD 99–110cm. The dependence of each dosimetric quantity on field size and SSD was examined to determine the minimum data set of measurements as a subset of the complete measurements. The “missing” data excluded in the minimum data set were approximated by linear or polynomial fitting functions based on the included data. The total measurement time and the calculated electron MU using the minimum and the complete data sets were compared. Results: The minimum data set includes 4 or 5 PDD’s and 51 to 66 point measurements for each electron energy, and more PDD’s and fewer point measurements are generally needed as energy increases. Using only <50% of complete measurement time, the minimum data set generates acceptable MU calculation results compared to those with the complete data set. The PDD difference is within 1 mm and the calculated MU difference is less than 1.5%. Conclusion: Data set measurement for TG-71 electron MU calculations can be minimized based on the knowledge of how each dosimetric quantity depends on various setup parameters. The suggested minimum data set allows acceptable MU calculation accuracy and shortens measurement time by a few hours.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-371: Development of a Linac Monte Carlo Model to Calculate Surface Dose

Purpose: To generate and validate a linac Monte Carlo (MC) model for surface dose prediction. Methods: BEAMnrc V4-2.4.0 was used to model 6 and 18 MV photon beams for a commercially available linac. DOSXYZnrc V4-2.4.0 calculated 3D dose distributions in water. Percent depth dose (PDD) and beam profiles were extracted for comparison to measured data. Surface dose and at depths in the buildup region was measured with radiochromic film at 100 cm SSD for 4 × 4 cm{sup 2} and 10 × 10 cm{sup 2} collimator settings for open and MLC collimated fields. For the 6 MV beam, films were placed at depths ranging from 0.015 cm to 2 cm and for 18 MV, 0.015 cm to 3.5 cm in Solid Water™. Films were calibrated for both photon energies at their respective dmax. PDDs and profiles were extracted from the film and compared to the MC data. The MC model was adjusted to match measured PDD and profiles. Results: For the 6 MV beam, the mean error(ME) in PDD between film and MC for open fields was 1.9%, whereas it was 2.4% for MLC. For the 18 MV beam, the ME in PDD for open fields was 2% and was 3.5% for MLC. For the 6 MV beam, the average root mean square(RMS) deviation for the central 80% of the beam profile for open fields was 1.5%, whereas it was 1.6% for MLC. For the 18 MV beam, the maximum RMS for open fields was 3%, and was 3.1% for MLC. Conclusion: The MC model of a linac agreed to within 4% of film measurements for depths ranging from the surface to dmax. Therefore, the MC linac model can predict surface dose for clinical applications. Future work will focus on adjusting the linac MC model to reduce RMS error and improve accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-431: Dosimetric Validation of Acuros XB Algorithm for Photon Dose Calculation in Water

Purpose: To validate the Acuros XB algorithm implemented in Eclipse Treatment planning system version 11 (Varian Medical System, Inc., Palo Alto, CA, USA) for photon dose calculation. Methods: Acuros XB is a Linear Boltzmann transport equation (LBTE) solver that solves LBTE equation explicitly and gives result equivalent to Monte Carlo. 6MV photon beam from Varian Clinac-iX (2300CD) was used for dosimetric validation of Acuros XB. Percentage depth dose (PDD) and profiles (at dmax, 5, 10, 20 and 30 cm) measurements were performed in water for field size ranging from 2×2,4×4, 6×6, 10×10, 20×20, 30×30 and 40×40 cm{sup 2}. Acuros XB results were compared against measurements and anisotropic analytical algorithm (AAA) algorithm. Results: Acuros XB result shows good agreement with measurements, and were comparable to AAA algorithm. Result for PDD and profiles shows less than one percent difference from measurements, and from calculated PDD and profiles by AAA algorithm for all field size. TPS calculated Gamma error histogram values, average gamma errors in PDD curves before dmax and after dmax were 0.28, 0.15 for Acuros XB and 0.24, 0.17 for AAA respectively, average gamma error in profile curves in central region, penumbra region and outside field region were 0.17, 0.21, 0.42 for Acuros XB and 0.10, 0.22, 0.35 for AAA respectively. Conclusion: The dosimetric validation of Acuros XB algorithms in water medium was satisfactory. Acuros XB algorithm has potential to perform photon dose calculation with high accuracy, which is more desirable for modern radiotherapy environment.

60 APPLIED LIFE SCIENCES↗

Highly Durable Fluorinated High Oxygen Permeability Ionomers for Proton Exchange Membrane Fuel Cells

For proton exchange membrane fuel cells to be cost-competitive in light- and heavy-duty vehicle applications, their Pt content in the catalyst layers needs to be lowered. However, lowering the Pt content results in voltage losses due to high local oxygen transport resistances at the ionomer–Pt interface. It is therefore crucial to use ionomers that have higher oxygen permeability than Nafion. In this paper, novel high oxygen permeability ionomers (HOPIs) are presented, with up to five times higher oxygen permeability than Nafion, synthesized by copolymerization of perfluoro-2,2-dimethyl-1,3-dioxole (PDD) with perfluoro(4-methyl-3,6-dioxaoct-7-ene) sulfonyl fluoride (PFSVE). PDD is the source of higher permeability due to its open ring structure, while PFSVE provides ionic conductivity. Optimization of PDD content and equivalent weight enables increased fuel cell performance, mainly at high current densities, where HOPIs can achieve power densities >1.25 W cm -2 and exceed the 0.8 A cm -2 U.S. Department of Energy durability target by losing only 4.5 mV, which is over six times less than 30 mV. Finally, the interactions between HOPI and SO 3 - groups with a PtCo/C catalyst are also elucidated here at a fundamental level.

25 ENERGY STORAGE↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of small-field tissue phantom ratio data generation methods for an Elekta Agility 6 MV photon beam

Tissue-phantom ratios (TPRs) are a common dosimetric quantity used to describe the change in dose with depth in tissue. These can be challenging and time consuming to measure. The conversion of percentage depth dose (PDD) data using standard formulae is widely employed as an alternative method in generating TPR. However, the applicability of these formulae for small fields has been questioned in the literature. Functional representation has also been proposed for small-field TPR production. This article compares measured TPR data for small 6 MV photon fields against that generated by conversion of PDD using standard formulae to assess the efficacy of the conversion data. By functionally fitting the measured TPR data for square fields greater than 4 cm in length, the TPR curves for smaller fields are generated and compared with measurements. TPRs and PDDs were measured in a water tank for a range of square field sizes. The PDDs were converted to TPRs using standard formulae. TPRs for fields of 4 × 4 cm{sup 2} and larger were used to create functional fits. The parameterization coefficients were used to construct extrapolated TPR curves for 1 × 1 cm{sup 2}, 2 × 2-cm{sup 2}, and 3 × 3-cm{sup 2} fields. The TPR data generated using standard formulae were in excellent agreement with direct TPR measurements. The TPR data for 1 × 1-cm{sup 2}, 2 × 2-cm{sup 2}, and 3 × 3-cm{sup 2} fields created by extrapolation of the larger field functional fits gave inaccurate initial results. The corresponding mean differences for the 3 fields were 4.0%, 2.0%, and 0.9%. Generation of TPR data using a standard PDD-conversion methodology has been shown to give good agreement with our directly measured data for small fields. However, extrapolation of TPR data using the functional fit to fields of 4 × 4 cm{sup 2} or larger resulted in generation of TPR curves that did not compare well with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗