Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Oxygen Consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Myocardial metabolism during exposure to carbon monoxide in the conscious dog.

Investigation of the relationship between coronary flow, heart rate, left ventricular function, and myocardial oxygen consumption at increasing levels of carboxyhemoglobin in conscious dogs. The results demonstrate a linear increase in coronary flow and heart rate as the carboxyhemoglobin increases up to 20%. Myocardial oxygen consumption declined during the same period.

Adams, J. D.↗

Research on inert gas narcosis and air velocity effects on metabolic performance

The effects of air velocity on metabolic performance are studied by using high forced airflow in a closed environment as a mechanism to control the concentration of volatile animal wastes. Air velocities between 100 and 200 ft/min are without significant effects on the metabolism of rats. At velocities of 200 ft/min and above, oxygen consumption and CO2 production as well as food consumption increase. In most instances, the changes are on the order of 5-10%. At the same time, the RQ for the animals increases slightly and generally correlates well with oxygen consumption and CO2 production. Experiments on the nature of inert gas narcosis show that halothane and methoxyflurane are rather potent inhibitors of the NADH:O2 oxidoreductase system in rats. These experiments suggest that the mechanism of inert gas narcosis is not mandatorily related to a membrane surface phenomenon.

Source record↗

Pyruvate ingestion for 7 days does not improve aerobic performance in well-trained individuals

The purposes of the present studies were to test the hypotheses that lower dosages of oral pyruvate ingestion would increase blood pyruvate concentration and that the ingestion of a commonly recommended dosage of pyruvate (7 g) for 7 days would enhance performance during intense aerobic exercise in well-trained individuals. Nine recreationally active subjects (8 women, 1 man) consumed 7, 15, and 25 g of pyruvate and were monitored for a 4-h period to determine whether blood metabolites were altered. Pyruvate consumption failed to significantly elevate blood pyruvate, and it had no effect on indexes of carbohydrate (blood glucose, lactate) or lipid metabolism (blood glycerol, plasma free fatty acids). As a follow-up, we administered 7 g/day of either placebo or pyruvate, for a 1-wk period to seven, well-trained male cyclists (maximal oxygen consumption, 62.3 +/- 3.0 ml. kg(-1). min(-1)) in a randomized, double-blind, crossover trial. Subjects cycled at 74-80% of their maximal oxygen consumption until exhaustion. There was no difference in performance times between the two trials (placebo, 91 +/- 9 min; pyruvate, 88 +/- 8 min). Measured blood parameters (insulin, peptide C, glucose, lactate, glycerol, free fatty acids) were also unaffected. Our results indicate that oral pyruvate supplementation does not increase blood pyruvate content and does not enhance performance during intense exercise in well-trained cyclists.

Randomized Controlled Trial↗

The effects of argon in the bioenergetics of the hamster and the rat

Oxygen consumption was examined in hamsters and rats exposed to normoxic mixtures of argon at 1 atm. In fasted and nonfasted animals, no marked change in O2 utilization was detectable at 22 C. However, at 7 C a significant decrease in oxygen consumption was observed where the animals were exposed in argon. The data are interpreted in terms of the greater thermal conductivity of nitrogen. The study was prompted by conflicting reports on the metabolic effects of argon and helium.

Tempel, G. E.↗

Thermoregulation in cold- and noncold-acclimated rats cold exposed in hypergravic fields

The effect of hypergravity on thermoregulation processes is investigated experimentally in rats. Hooded male Long-Evans rats were kept for 6 weeks at 5 or 23 C (cold-acclimated and noncold-acclimated groups, CA and NCA) prior to testing. One test protocol comprised sequential 1-h exposures to 23 C at 1 G, 23 C at 3 G (in a 2.1-m radius centrifuge; -Gx), 8 C at 3 G, 8 C at 1 G, and finally 23 C at 1 G, with continuous measurement of the oxygen consumption. In a second protocol, restrained rats were exposed to 23 C at 1 G, 23 C at 3 G, and 10 C at 3 G, and core temperature changes were monitored. The results are presented in graphs and a table. Oxygen consumption doubled in both CA and NCA rats on exposure to cold at 1 G, but at 3 G NCA consumption decreased while CA consumption remained high. The CA rats were also more able to maintain core temperature at 3 G than the NCA rats. These differences are attributed to the nonshivering thermogenic processes developed in CA rats, which appear to be unaffected by hypergravity.

Horowitz, J. M.↗

Characterization of a broadly specific cadaverine N-hydroxylase involved in desferrioxamine B biosynthesis in Streptomyces sviceus

N-hydroxylating flavin-dependent monooxygenases (FMOs) are involved in the biosynthesis of hydroxamate siderophores, playing a key role in microbial virulence. Herein, we report the first structural and kinetic characterization of a novel alkyl diamine N-hydroxylase DesB from Streptomyces sviceus (SsDesB). This enzyme catalyzes the first committed step in the biosynthesis of desferrioxamine B, a clinical drug used to treat iron overload disorders. X-ray crystal structures of the SsDesB holoenzyme with FAD and the ternary complex with bound NADP + were solved at 2.86 Å and 2.37 Å resolution, respectively, providing a structural view of the active site environment. SsDesB crystallized as a tetramer and the structure of the individual protomers closely resembles the structures of homologous N-hydroxylating FMOs from Erwinia amylovora (DfoA), Pseudomonas aeruginosa (PvdA), and Aspergillus fumigatus (SidA). Using NADPH oxidation, oxygen consumption, and product formation assays, kinetic parameters were determined for various substrates with SsDesB. SsDesB exhibited typical saturation kinetics with substrate inhibition at high concentrations of NAD(P)H as well as cadaverine. The apparent k cat values for NADPH in steady-state NADPH oxidation and oxygen consumption assays were 0.28 ± 0.01 s -1 and 0.24 ± 0.01 s -1 , respectively. However, in product formation assays used to measure the rate of N-hydroxylation, the apparent k cat for NADPH (0.034 ± 0.008 s -1 ) was almost 10-fold lower under saturating FAD and cadaverine concentrations, reflecting an uncoupled reaction, and the apparent NADPH K M was 33 ± 24 μM. Under saturating FAD and NADPH concentrations, the apparent k cat and K M for cadaverine in Csaky assays were 0.048 ± 0.004 s -1 and 19 ± 9 μM, respectively. SsDesB also N-hydroxylated putrescine, spermidine, and L-lysine substrates but not alkyl (di)amines that were branched or had fewer than four methylene units in an alkyl chain. These data demonstrate that SsDesB has wider substrate scope compared to other well-studied ornithine and lysine N-hydroxylases, making it an amenable biocatalyst for the production of desferrioxamine B, derivatives, and other N-substituted products.

59 BASIC BIOLOGICAL SCIENCES↗

Influences of chemical sympathectomy, demedullation, and hindlimb suspension on the V(O2)max of rats

The contributions of catecholamines from the adrenal medulla to the reduction in maximal oxygen consumption is investigated in chemically sympathectomized rats. The rats are injected with saline and chemically sympathectomized, and approximately half of the rats are surgically demedullated. The subjects undergo head-down suspension for two weeks and are examined in terms of submaximal mechanical efficiency, treadmill run time, and maximal oxygen consumption. Rats with adrenal medullas and injected with saline demonstrate reduced levels of maximal O consumption, whereas chemically sympathectomized rats with adrenal medullas showed no significant reduction. Reduced levels of maximal O consumption is also noted in the sympathectomized demedullated rats. The paper concludes that circulating epinephrine enhances the attenuation of the decrease in the maximal O consumption caused by chemical sympathectomy.

Woodman, Christopher R.↗

Restraint hypothermia in cold-exposed rats at 3 G and 1 G

The relationship between heat loss, heat production, and hypothermia was investigated in experiments with rats which determined if hypergravity affects heat production by altering oxygen consumption and if restraint modifies the ability of the rats to activate thermogenic mechanisms after cold exposure in a hypergravic field. Restrained and unrestrained rats were exposed for 1 hr periods to 1 G and 3 G at ambient temperatures of 24 C or 10 C, and the rate of oxygen consumption, the core temperatures, and the tail temperatures were measured. Results show that thermoregulatory mechanisms are impaired when rats are exposed to 3 G fields, and at 24 C as well as at 10 C this impairment leads to an inappropriate increase in heat loss.

Monson, C. B.↗

Comparison of V-4 and V-5 Exercise/Oxygen Prebreathe Protocols to Support Extravehicular Activity in Microgravity

The Prebreathe Reduction Program (PRP) used exercise during oxygen prebreathe to reduce necessary prebreathe time prior to depressurizing to work in a 4.3 psi suit during extravehicular activity (EVA). Initial testing produced a two-hour protocol incorporating ergometry exercise and a 30 min cycle of depress/repress to 10.2 psi where subjects breathed 26.5% oxygen/balance nitrogen (Phase II - 10 min at 75% peak oxygen consumption [VO2 peak] followed by 40 min intermittent light exercise [ILE] [approx. 5.8 mL-per kilogram- per minute], then 50 min of rest). The Phase II protocol (0/45 DCS) was approved for operations and has been used on 40 EVAs, providing significant time savings compared to the standard 4 h resting oxygen prebreathe. The Phase V effort focused on performing all light in-suit exercise. Two oxygen prebreathe protocols were tested sequentially: V-4) 160 min prebreathe with 150 min of continuous ILE. The entire protocol was completed at 14.7 psi. All exercise involved upper body effort. Exercise continued until decompression. V-5) 160 min prebreathe with 140 min of ILE - first 40 min at 14.7 psi, then 30 min at 10.2 psi (breathing 26.5% oxygen) after a 20 min depress, simulating a suit donning period. Subjects were then repressed to 14.7 psi and performed another 50 min of lower body ILE, followed by 50 min rest before decompression. The V-4 protocol was rejected with 3 DCS/6 person-exposures. Initial V-5 testing has produced 0 DCS/11 person-exposures (ongoing trials). The difference in DCS rate was significant (Fisher Exact p=0.029). The observations of DCS were significantly lower in early V-5 trials than in V-4 trials. Additional studies are required to evaluate the relative contribution of the variables in exercise distribution, the 10.2 psi depress/repress component, pre-decompression rest, or possible variation in total oxygen consumption.

Pollock, N. W.↗

Heat Production During Countermeasure Exercises Planned for the International Space Station

This investigation's purpose was to determine the amount of heat produced when performing aerobic and resistance exercises planned as part of the exercise countermeasures prescription for the ISS. These data will be used to determine thermal control requirements of the Node 1 and other modules where exercise hardware might reside. To determine heat production during resistive exercise, 6 subjects using the iRED performed 5 resistance exercises which form the core exercises of the current ISS resistive exercise countermeasures. Each exerciser performed a warm-up set at 50% effort, then 3 sets of increasing resistance. We measured oxygen consumption and work during each exercise. Heat loss was calculated as the difference between the gross energy expenditure (minus resting metabolism) and the work performed. To determine heat production during aerobic exercise, 14 subjects performed an interval, cycle exercise protocol and 7 subjects performed a continuous, treadmill protocol. Each 30-min. exercise is similar to exercises planned for ISS. Oxygen consumption monitored continuously during the exercises was used to calculate the gross energy expenditure. For cycle exercise, work performed was calculated based on the ergometer's resistance setting and pedaling frequency. For treadmill, total work was estimated by assuming 25% work efficiency and subtracting the calculated heat production and resting metabolic rate from the gross energy expenditure. This heat production needs to be considered when determining the location of exercise hardware on ISS and designing environmental control systems. These values reflect only the human subject s produced heat; heat produced by the exercise hardware also will contribute to the heat load.

Rapley, Michael G.↗

Global Kinetic Constants for Thermal Oxidative Degradation of a Cellulosic Paper

Values of global kinetic constants for pyrolysis, thermal oxidative degradation, and char oxidation of a cellulosic paper were determined by a derivative thermal gravimetric study. The study was conducted at heating rates of 0.5, 1, 1.5, 3, and 5 C/min in ambient atmospheres of nitrogen, 0.28, 1.08, 5.2 percent oxygen concentrations, and air. Sample weight loss rate, concentrations of CO, CO2, and H2O in the degradation products, and oxygen consumption were continuously measured during the experiment. Values of activation energy, preexponential factor, orders of reaction, and yields of CO, CO2, H2O, total hydrocarbons, and char for each degradation reaction were derived from the results. Heat of reaction for each reaction was determined by differential scanning calorimetry. A comparison of the calculated CO, CO2, H2O, total hydrocarbons, sample weight loss rate, and oxygen consumption was made with the measured results using the derived kinetic constants, and the accuracy of the values of kinetic constants was discussed.

Kashiwagi, Takashi↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Spatial Study 2022: Water Column, Sediment, and Total Ecosystem Respiration Rates across the Yakima River Basin, Washington, USA (v2)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin and is associated with the manuscript “Sediment-associated processes account for most of the spatial variation in ecosystem respiration in the Yakima River basin” submitted to Nature Communications Earth & Environment (Garayburu-Caruso et al., in review). The dataset provides ecosystem metabolism estimates generated from streamMetabolizer (Appling et al.; 2018) using data collected during the same five-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. Additionally, it includes the scripts used for the analysis and producing the figures in the manuscript. The contents include streamMetabolizer inputs and outputs and additional relevant data needed to generate the main manuscript results. The data included are: total ecosystem respiration, water respiration, calculated sediment-associated respiration, gross primary production outputs from the river corridor model for the Yakima River Basin, median grain size (d50), depth, dissolved oxygen, water temperature, pressure, and annual oxygen consumption. The associated GitHub repository can be found at https://github.com/river-corridors-sfa/SSS_metabolism. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” Raw time series sensor data, total suspended solids, and depth data from SSS were published at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1969566. A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Field metadata for the samples in this da This dataset is comprised of one main data folder with four subfolders. The main data folder contains of (1) file-level metadata; (2) data dictionary; (3) total/water column/sediment respiration; (4) gross primary production (GPP); (5) median grain size (d50); and (6) annual oxygen consumption. The “Figures” subfolder contains the figures used in the paper and all intermediate files (including geospatial files). The “Published_Data” contains a readme directing the user to download the public data to reproduce analyses and figures. The “Scripts” folder contains all scripts used in the analyses that were not part of running StreamMetabolizer. Lastly, the “Stream_Metabolizer” folder contains all files associated with running StreamMetabolizer including (1) model input files, (2) model output files, (3) processing scripts, (4) histogram plots of the outputs, and (5) an R project. All files are .csv, .pdf, .R, .Rmd, .Rproj, .html, .png, .txt, .qgz, .cpg, .dbf, .prj, .shp, .shp.ea.iso.xml, .shp.iso.xml, .shx, .sbn. ta package can be found at either link. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Validation of the Pulmonary Function System for Use on the International Space Station

Aerobic deconditioning occurs during long duration space flight despite the use of exercise countermeasures (Convertino, 1996). As a part of International Space Station (ISS) medical operations, periodic tests designed to estimate aerobic capacity are performed to track changes in aerobic fitness and to determine the effectiveness of exercise countermeasures. These tests are performed prior to, during, and after missions of greater than 30 days in duration. Crewmembers selected for missions aboard the ISS perform a graded exercise test on a cycle ergometer approximately 270 days prior to their scheduled launch date in order to measure peak oxygen consumption (VO2PK) and peak heart rate (HRpk). Approximately 30 to 45 days prior to launch, crewmembers perform a submaximal cycle ergometer test at work rates set to elicit 25, 50 and 75% of their pre-flight VO2PK. This test, known as the Periodic Fitness Evaluation (PFE), serves as a baseline measure to which subsequent in-and post-flight exercise tests are compared. While onboard the ISS, crewmembers are normally scheduled to perform the PFE beginning with flight day (FD) 14 and every 30 days thereafter. The PFE is also conducted 5 and 30 days following flight. Using PFE data, aerobic fitness is estimated by quantifying the VO2 vs. HR relationship using linear regression and calculating the VO2 that would occur at the crewmember s previously measured HRpk. Currently, for data collected during flight, this technique assumes that the pre- vs. in-flight oxygen consumption per given cycle workload is similar. However, the validity of this assumption is based upon a sparse amount of data collected during the Skylab era (Michel, et al. 1977). The method of using heart rate and cycle ergometer work rates has been used to estimate aerobic fitness in normal gravity (Astrand and Ryhming, 1954; Lee, 1993). Due to spaceflight induced physiological alterations, such as shifts in extracellular fluid (e.g. plasma) volume, this method may not be valid during space flight. In addition, the ergometer onboard ISS is vibration-isolated and moves with the astronaut s application of force into the pedals. The effect of this movement on the VO2 of cycle exercise on ISS has not been quantified.

McCleary, Frank A.↗

Metabolic multireactor: Practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

We present a system for carrying out small batch reactor oxygen consumption experiments on water and sediment samples for environmental questions. In general, it provides several advantages that can help researchers achieve impactful experiments at relatively low costs and high data quality. In particular, it allows for multiple reactors to be operated and their oxygen concentrations to be measured simultaneously, providing high throughput and high time-resolution data, which can be advantageous. Most existing literature on similar small batch-reactor metabolic studies is limited to either only a few samples, or only a few time points per sample, which can restrict the ability for researchers to learn from their experiments. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. As such we do not delve deeply into the specifics of the fluorescent dye sensing mechanism. Instead, we focus on practical considerations. We describe the construction and operation of the calibration and experimental systems, and answer many of the questions likely to come up when other researchers choose to build and operate a similar system themselves (questions we ourselves had when we first built the system). In this way, we hope to provide an approachable and easy to use research article that can help other researchers construct and operate a similar system that can be tailored to ask their own research questions, with a minimum of confusion and missteps along the way.

3D printing↗