Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Other,ENG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurement Of The Neutron Spectrum Of A DD Electronic Neutron Generator

A Cuttler-Shalev (C-S){sup 3}He proportional counter has been used to measure the energy spectrum of neutrons from a portable deuterium-deuterium electronic neutron generator. To improve the analysis of results from the C-S detector digital pulse shape analysis techniques have been used to eliminate neutron recoil artifacts in the recorded data. Data was collected using a 8-GHz, 10-bit waveform digitizer with its full scale corresponding to approximately 6-MeV neutrons. The measurements were made with the detector axis perpendicular to the direction of ions in the ENG in a plane 0.5-m to the side of the ENG, measuring neutrons emitted at an angle from 87.3 deg. to 92.7 deg. with respect to the path of ions in the ENG. The system demonstrated an energy resolution of approximately 0.040 MeV for the thermal peak and approximately 0.13 MeV at the DD neutron energy. In order to achieve the ultimate resolution capable with this type of detector it is clear that a higher-precision digitizer will be needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Neutron Interrogation to Detect Shielded Fissionable Material

Portable electronic neutron generators (ENGs) may be used to interrogate suspicious items to detect, characterize, and quantify the presence fissionable material based upon the measurement of prompt and/or delayed emissions of neutrons and/or photons resulting from fission. The small size (<0.2 m3), light weight (<12 kg), and low power consumption (<50 W) of modern ENGs makes them ideally suited for use in field situations, incorporated into systems carried by 2-3 individuals under rugged conditions. At Idaho National Laboratory we are investigating techniques and portable equipment for performing active neutron interrogation of moderate sized objects less than ~2-4 m3 to detect shielded fissionable material. Our research in this area relies upon the use of pulsed deuterium-tritium ENGs and the measurement of die-away prompt fission neutrons and other neutron signatures in-between neutron pulses from the ENG and after the ENG is turned off.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanosecond carrier lifetimes in solution-processed enargite (Cu 3 AsS 4 ) thin films

Enargite (ENG) Cu 3 AsS 4 is a promising material for photovoltaic applications due to its constituent earth abundant elements of differing ionic radii, ideal predicted optoelectronic properties, and demonstrated use in a working thin-film solar cell. However, little is known about ENG's defect properties; such knowledge is necessary to assess its potential for future use in high-efficiency devices. One indicator of a material's quality is its photogenerated carrier lifetime, which can be related to its bulk defect properties. Here, we use a combination of time-resolved terahertz spectroscopy and time-resolved photoluminescence to assess carrier dynamics in ENG thin films processed from nanoparticle precursors. The Shockley–Read–Hall (SRH) lifetimes are on the multi-nanosecond scale, which exceed those reported in more mature systems and represent promising values for a candidate photovoltaic material. These results suggest that ENG is worthy of further research and development effort with an eye toward future photovoltaic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

INL Neutron Interrogation R&D: FY2010 MPACT End of Year Report

Experiments have been carried out to investigate the feasibility and utility of using neutron interrogation and small-scale, portable prompt gamma-ray neutron activation analysis (PGNAA) instruments for assaying uranium for safeguards applications. Prior work has shown the potential of the PGNAA technique for assaying uranium using reactor-based neutron sources and high-yield electronic neutron generators (ENGs). In this project we adapted Idaho National Laboratory's portable isotopic neutron spectroscopy (PINS) PGNAA system for measuring natural-enrichment uranium yellowcake and metallic depleted uranium and highly enriched uranium. This work used 252Cf as well as deuterium-deuterium (DD) and deuterium-tritium (DT) ENGs. For PGNAA measurements a limiting factor when assaying large objects is the detector dead time due to fast-neutron scattering off of the uranium; this limits the maximum useable neutron source strength to O(107) neutrons per second. Under these conditions the low PGNAA reaction cross sections for uranium prohibited the collection of useful uranium PGNAA signatures from either the yellowcake or metallic uranium samples. Measurement of the decay product activation in these materials following irradiation in the PGNAA geometry similarly did not produce useful uranium activation product – fission product signatures. A customized irradiation geometry tailored to optimally thermalize the interrogation neutron source, intended only for generating long-lived activation products – fission products and not intended for PGNAA measurements, might be possible using small scale ENGs but an application need and a modeling and simulation exercise would be recommended before advancing to experiments. Neutron interrogation PGNAA using a DT-ENG was found to be a quick and useful qualitative method for detecting the presence of oxygen in natural-enrichment uranium yellowcake. With a low effort of development work it would be reasonable to expect this measurement could be transitioned to a qualitative technique for assaying oxides as well as other common uranium matrices including nitrides, fluorides, carbides, and sodium-bonded metals. Inert-matrix fuel material confirmation would also be well-served through this technique. This may be of interest for nuclear Material Protection, Accounting, and Control for Transmutation (MPACT) safeguards applications as a method for confirming material-form declarations in advanced fuel cycle material inventories and for quality control during fuel fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining the temporal evolution of hypervelocity impact phenomena via high-speed imaging and ultraviolet-visible emission spectroscopy

The temporal evolution of a previously observed hypervelocity impact-induced vapor cloud [Mihaly et al., Int. J. Impact Eng. 62, 13 (2013)] was measured by simultaneously recording several full-field, near-IR images of the resulting emission using an OMA-V high-speed camera. A two-stage light-gas gun was used to accelerate 5 mg Nylon 6/6 right-cylinders to speeds between 5 km/s and 7 km/s to impact 1.5 mm thick 6061-T6 aluminum target plates. Complementary laser-side-lighting [Mihaly et al., Int. J. Impact Eng. 62, 13 (2013); Proc. Eng. 58, 363 (2013)] and front-of-target (without laser illumination) images were also captured using a Cordin ultra-high-speed camera. The rapid expansion of the vapor cloud was observed to contain a bright, emitting exterior, and a darker, optically thick interior. The shape of this phenomenon was also observed to vary considerably between experiments due to extremely high-rate (>250 000 rpm) of tumbling of the cylindrical projectiles. Additionally, UV-vis emission spectra were simultaneously recorded to investigate the temporal evolution of the atomic and molecular composition of the up-range, impact-induced vapor plume. A PI-MAX3 high-speed camera coupled to an Acton spectrograph was utilized to capture the UV-vis spectra, which shows an overall peak in emission intensity between approximately 6–10 μs after impact trigger, corresponding to an increased quantity of emitting vapor/plasma passing through the spectrometer slit during this time period. The relative intensity of the numerous spectral bands was also observed to vary according to the exposure delay of the camera, indicating that the different atomic/molecular species exhibit a varied temporal evolution during the vapor cloud expansion. Higher resolution spectra yielded additional emission lines/bands that provide further evidence of interaction between fragmented projectile material and the 1 mmHg atmosphere inside the target chamber. A comparison of the data to down-range emission spectra also revealed differences in the relative intensities of the atomic/molecular composition of the observed vapor clouds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comment on Comment on “Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments”*

Abstract Cangialosi, Alegría, and Colmenero have made a comment on a paper of ours [Polym. Eng. Sci. 2022:1–13], in which we discussed the concern that the enthalpy recovery data reported by Cangialosi and co‐workers [Phys. Rev. Lett. 2013;111(9):095701] for polystyrene aged up to 15 K below glass transition temperature was anomalous and contradicted existing experimental results from the literature over a similar range of aging conditions. Their response shifts the focus away from the raised questions about their experimental results and attempts to invalidate the data that we cited in support of our argument. Here we respond to the comment and add additional analysis that suggests the structural recovery response of glassy materials exhibits smooth behavior over the full range of measurements, up to 7 or 8 logarithmic decades. We do this by referring to the work on the intrinsic isotherm down‐jump and memory responses of poly(vinyl acetate) between 40°C and 15°C over six logarithmic decades by Kovacs [Fortsch. Hochpolym. Fo. 1963;3(1/2):394–508], the small‐strain tensile creep of poly(vinyl chloride) quenched from 90°C to 40°C (approximately 40°C below T g ) over seven logarithmic decades from Struik [Polym Eng. Sci., 1977;17:165–173], and the volume recovery behavior for aging times up to 3 months in a temperature range between 95°C and −50°C by Greiner and Schwarzl [Rheol. Acta. 1984;23(4):378–395]. We also add discussion that an isothermal aging procedure using a vacuum oven is highly vulnerable to temperature errors due to the problem of good temperature control when the heat transfer mechanism is primarily radiative.

Jin, Shuang↗

Variation in Telangiectasia Predisposing Genes Is Associated With Overall Radiation Toxicity

Purpose: In patients receiving radiotherapy for breast cancer where the heart is within the radiation field, cutaneous telangiectasiae could be a marker of potential radiation-induced heart disease. We hypothesized that single nucleotide polymorphisms (SNPs) in genes known to cause heritable telangiectasia-associated disorders could predispose to such late, normal tissue vascular damage. Methods and Materials: The relationship between cutaneous telangiectasia as a late normal tissue radiation injury phenotype in 633 breast cancer patients treated with radiotherapy was examined. Patients were clinically assessed for the presence of cutaneous telangiectasia and genotyped at nine SNPs in three candidate genes. Candidate SNPs were within the endoglin (ENG) and activin A receptor, type II-like 1 (ACVRL1) genes, mutations in which cause hereditary hemorrhagic telangiectasia and the ataxia-telangiectasia mutated (ATM) gene associated with ataxia-telangiectasia. Results: A total of 121 (19.1%) patients exhibited a degree of cutaneous telangiectasiae on clinical examination. Regression was used to examine the associations between the presence of telangiectasiae in patients who underwent breast-conserving surgery, controlling for the effects of boost and known brassiere size (n=388), and individual geno- or haplotypes. Inheritance of ACVRL1 SNPs marginally contributed to the risk of cutaneous telangiectasiae. Haplotypic analysis revealed a stronger association between inheritance of a ATM haplotype and the presence of cutaneous telangiectasiae, fibrosis and overall toxicity. No significant association was observed between telangiectasiae and the coinheritance of the candidate ENG SNPs. Conclusions: Genetic variation in the ATM gene influences reaction to radiotherapy through both vascular damage and increased fibrosis. The predisposing variation in the ATM gene will need to be better defined to optimize it as a predictive marker for assessing radiotherapy late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗