Self-destruct charge ordnance component of the Agena D vehicle self-destruct system
Self-destruct explosive charge component of Agena D flight termination system
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Self-destruct explosive charge component of Agena D flight termination system
Explore the source record for details and available documents.
Exploding bridgewire /EBW/ systems compared to hot-wire initiators for Mars space probe
Development of falling sphere for atmospheric density measurements onboard ships
Explore the source record for details and available documents.
A single-stage axial-flow turbine was investigated to determine the effect of increased stator throat area on the performance level of a turbojet engine turbine. The stator blades were bent to increase the throat area in order to move the compressor operating point in the engine farther away from surge. Results are compared with those obtained with the as-cast stator setting.
Recent progress on system development in the laser initiation of explosive devices is summarized. The topics included are: development of compact free-running mode and Q-switched lasers, development of low-loss fiber optic bundles and connectors, study of nuclear radiation effects on the system, characterization of laser initiation sensitivities of insensitive high explosives, and the design methods used to achieve attractive system weight and cost savings. Direction for future work is discussed.
McDonnell Douglas Missile Systems Company (MDMSC) has developed a laser ignition subsystem (LIS) for air-to-air missile applications. The MDMSC subsystem is designed to activate batteries, unlock fins, and sequence propulsion system events. The subsystem includes Pyro Zirconium Pump (PZP) lasers, mechanical Safe & Arm, fiber-optic distribution system, and optically activated pyrotechnic devices (initiators, detonators, and thermal batteries). The LIS design has incorporated testability features for the laser modules, drive electronics, fiber-optics, and pyrotechnics. Several of the LIS have been fabricated and have supported thermal battery testing, integral rocket ramjet testing, and have been integrated into integral rocket ramjet flight test vehicles as part of the flight control subsystem.
The topics are presented in viewgraph form and include the following: characteristics, system description, laser firing unit, fiber optic cables, and initiators.
Launch vehicles and spacecraft use explosively initiated devices to effect numerous events from lift-off to orbit. These explosive devices are electrically initiated by way of electro-mechanical switching networks. Today's technology indicates that upgrading to solid state control circuits and laser initiated explosive devices can improve performance, streamline operations and reduce costs. This paper describes a plan to show that these technology advancements are viable for Air Force Space and Missile System Center (SMC) program use, as well as others.
Explore the source record for details and available documents.
To fully characterize the inductive response of an isolated conductive object, such as buried unexploded ordinance, one needs to measure its response to stimulation by primary magnetic fields in three linearly independent (e.g., approximately orthogonal) directions. In one embodiment this is achieved by measuring the response to magnetic fields of three independent transmitters arranged to have magnetic fields that are linearly independent. According to the apparatus and methods employing the system of this invention, multiple transmitters and receivers of known relative position and orientation on a single platform are used. In a preferred embodiment, matched sets of receiver pairs connected in gradient mode are positioned adjacent to closely spaced pairs of transmitting coils, such that a minor displacement of one or both of the receiver coil pairs relative to the paired transmitting coils will not affect the detected secondary signals emitted by a buried metallic object.
One historical industrial activity area is associated with R001, R-SMA-0.5: Site C-00-020. Area of Concern (AOC) C-00-020 is a suspected mortar impact area located along the north valley wall of Rendija Canyon on General Services Administration (GSA) and U.S. Forest Service (USFS) land. The 30-acre site also includes a tributary of Rendija Canyon. Most of the site lies within the Santa Fe National Forest, except for a small area on the southeastern edge that is private property. AOC C-00-020 was suspected to be a former mortar-impact area because of a “U.S. Property—No Trespassing” sign and a nearly illegible bilingual sign posted in the area. The signs no longer remain. Extensive archival searches have revealed no documentation regarding the use of this site as a munitions impact area. In addition, no field evidence of operations (e.g., munitions debris [MD], munitions and explosives of concern [MEC], unexploded ordnance [UXO], or impact scars) has ever been found at AOC C-00-020. Resource Conservation and Recovery Act (RCRA) facility investigation (RFI) activities conducted in 1993 included conducting an ordnance sweep followed by a geophysical sweep. No ordnance, MD, MEC, or UXO was located. In addition, no ordnance was found during the 2007 investigation or during the 2009 ordnance survey. The site is located within an area burned by the 2000 Cerro Grande fire. The stream channel that runs through the center of the site has been widened by flooding. Currently, there are burned and live trees on the steep slopes next to the stream. Ordnance surveys at the site resulted in no findings except for scrap metal such as bailing wire. The complete absence of ordnance and explosives waste (OEW) confirmed that the site was never used as an ordnance-impact area. In accordance with the approved investigation work plan, no further investigation was conducted at AOC C-00-020. The New Mexico Environment Department (NMED) concurred with the conclusion that no additional ordnance surveys need to be conducted at this site and issued a corrective action complete without controls for AOC C-00-020 on May 16, 2012. No industrial materials were historically managed at this Site; therefore, no potential contaminants are associated with the Site.
The concept for a dual test item has been developed for use in simulating live initiators/detonators during ground testing to verify the proper operation of the safing and firing circuitry for ground and flight systems ordnance as well as continuous monitoring for any stray voltages. Previous ordnance simulators have consisted of fuses, flash bulbs, inert devices with bridge wires, and actual live ordnance items mounted in test chambers. Stray voltage detectors have included devices connected to the firing circuits for continuous monitoring and a final no-voltage test just prior to ordnance connection. The purpose of this combined ordnance simulation and stray-voltage detection is to provide an improved and comprehensive method to ensure the ordnance circuitry is verified safe and operational.
1.1 Purpose and Scope. This report summarizes the activities, compliance status, annual inspection, and environmental monitoring results from calendar year 2015 for the Weldon Spring, Missouri, Site. The U.S. Department of Energy (DOE) prepares this annual report as part of the site’s long-term surveillance and maintenance (LTS&M) activities, in accordance with the requirements of the Long-Term Surveillance and Maintenance Plan for the Weldon Spring, Missouri, Site (LTS&M Plan) (DOE 2008a) and the Federal Facility Agreement for the Weldon Spring Site (DOE 2006). The Weldon Spring site is a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) site. 1.2 Site Description. The Weldon Spring site is located in St. Charles County, Missouri, about 30 miles west of St. Louis, Missouri (Figure 1). The site comprises two geographically distinct, DOE-owned properties: the former Weldon Spring Chemical Plant and Raffinate Pit sites (Chemical Plant) and the former Weldon Spring Quarry (Quarry). The former Chemical Plant is located about 2 miles southwest of the junction of Missouri State Route 94 and Interstate 64. The Quarry is about 4 miles southwest of the former Chemical Plant. Both sites are accessible from Missouri State Route 94. During the early 1940s, the Department of the Army acquired 17,232 acres of private land in St. Charles County for the construction of the Weldon Spring Ordnance Works facility. The former Ordnance Works site has since been divided into several contiguous areas under different ownership, as depicted in Figure 2. Current land use of the former Ordnance Works site includes the former Chemical Plant and Quarry, the U.S. Army Reserve Weldon Spring Training Area, the Missouri Department of Conservation (MDC), the Missouri Department of Natural Resources (MDNR) Division of State Parks (MDNR-Parks), Francis Howell High School, a St. Charles County highway maintenance (formerly Missouri Department of Transportation [MoDOT]) facility, the Public Water Supply District No. 2 water supply facility, the St. Charles County law enforcement training center, the village of Weldon Spring Heights, and a University of Missouri research park. The former Chemical Plant and Quarry areas total 228.16 acres. The Former Chemical Plant property occupies 219.50 acres, and the Quarry occupies 8.66 acres.
Many systems derive their electromagnetic radiation (EMR) environments from Mil-Std-464C or Mil-Std-464D, Electromagnetic Environmental Effects Requirements for Systems. This standard defines several EMR environments based on the type of system and expected application. Many nuclear weapon (NW) systems reference the ordnance environments as the starting point for their functional EMR requirements, since any item intended to go into Department of Defense (DOD) custody is expected to be certified hazards of electromagnetic radiation to ordnance (HERO) safe when exposed to the environments listed in Mil-Std-464 Table 9. This environment is defined as the envelope of all sources any system in DOD custody may ever encounter, however, and may include sources that are not relevant for a particular system. This document is intended to provide additional clarity on the Mil-Std-464C and Mil-Std-464D EMR environments, specifically the driving sources for the maximum ordnance levels. This supplementary information may be used to guide tailoring of relevant environments or application to different systems with the additional consideration of any shielding that may reduce the external environments defined in the military standard.
The objective of the ARTS program was to develop lighter and less expensive spacecraft ordnance and release systems that answer to the requirements of a wide variety of spacecraft applications. These improvements were to be evaluated at the spacecraft system level, as it was determined that there were substantial system-level costs associated with the present ordnance and release subsystems. New, better devices were to be developed, then flight qualified, then integrated into a flight experiment in order to prove the reliability required for their subsequent use on high-reliability spacecraft. The secondary goal of the program was to quantify the system-level benefits of these new subsystems based upon the development program results. Three non-explosive release mechanisms and one laser-diode-based ordnance system were qualified under the program. The release devices being developed were required to release high preloads because it is easier to scale down a release mechanism than to scale it up. The laser initiator developed was required to be a direct replacement for NASA Standard Initiators, since these are the most common initiator in use presently. The program began in October, 1991, with completion of the flight experiment scheduled for February, 1994. This paper provides an overview of the ARTS program, discusses the benefits of using the ARTS components, introduces the new components, compares them with conventional systems and each other, and provides recommendations on how best to implement them.
This paper presents an application of statistical engineering to solve the problem of determining the effects of reducing test sample sizes and environment levels in lot acceptance testing (LAT) of ordnance devices used by NASA and DoD space systems. Unlike environmental testing of dedicated qualification hardware, ordnance devices have a test-like-you-fly exception and use lot acceptance sampling or LAT. LAT is performed by randomly selecting a predefined number of devices from an individual lot and exposing them to a more severe dynamic shock and vibration testing environments than flight (sometimes as high as 6 decibels over flight environments) and then performing a destructive test on the device. Recent trends have been suggested to reduce LAT costs by reducing environment test levels or the number of devices per LAT, or both. A method is given here to compute flight risk, so the proposed methods can be compared by subject matter experts to the baseline LAT methods. In addition, this method can be used to determine the best methods to include in future LAT standards for pyrotechnic devices.