Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Orbitrap™”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of Novel Microcystins Using High-Resolution MS and MS n with Python Code

Cyanotoxins called microcystins (MCs) are highly toxic and can be present in drinking water sources. Determining the structure of MCs is paramount because of its effect on toxicity. Though over 300 MC congeners have been discovered, many remain unidentified. In this work, a method is described for the putative identification of MCs using liquid chromatography (LC) coupled with high-resolution (HR) Orbitrap mass spectrometry (MS) and a new bottom-up sequencing strategy. Maumee River water samples were collected during a harmful algal bloom and analyzed by LC–MS with simultaneous HRMS and MS/MS. Unidentified ions with characteristic MC fragments (135 and 213 m/z) were recognized as possible novel MC congeners. An innovative workflow was developed for the putative identification of these ions. Python code was written to generate the potential structures of unidentified MCs and to assign ions after the fragmentation for structural confirmation. The workflow enabled the putative identification of eight previously reported MCs for which standards are not available and two newly discovered congeners, MC-HarR and MC-E(OMe)R.

54 ENVIRONMENTAL SCIENCES↗

Augmentation of MS/MS Libraries with Spectral Interpolation for Improved Identification

Tandem mass spectrometry (MS/MS) is a primary tool for identification of small molecules and metabolites where resultant spectra are most commonly identified by matching them with spectra in MS/MS reference libraries. The high degree of variability in MS/MS spectrum acquisition techniques and parameters creates a significant challenge for building standardized reference libraries. Here we present a method to improve the usefulness of existing MS/MS libraries by augmenting available experimental spectra datasets with statistically interpolated spectra at unreported collision energies. We find that highly accurate spectral approximations can be interpolated from as few as three experimental spectra and that the interpolated spectra will be consistent with true spectra gathered from the same instrument as the experimental spectra. Supplementing existing spectral databases with interpolated spectra yields consistent improvements to identification accuracy on a range of instruments and precursor types. Applying this method yields significant improvements (~10% more spectra correctly identified) on large datasets (2,000 - 10,000 spectra), indicating this is a quick yet adept tool for improving spectral matching in situations where available reference libraries are not yet sufficient. We also find improvements of matching spectra across instrument types (between an Agilent Q-TOF and an Orbitrap Elite), at high collision energies (50 - 90 eV), and with smaller datasets available through MassBank.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing Top-Down Proteoform Identification: Deconvolution, PrSM Overlap, and PTM Detection

Generating top-down tandem mass spectra (MS/MS) for complex mixtures of proteoforms has become possible through improvements in fractionation, on-line separation, dissociation, and mass analysis. The algorithms to match tandem mass spectra to sequences have undergone a parallel evolution, with both spectral alignment and peak matching being paired with diverse methods for scoring proteoform-spectral matches (PrSMs). This study assesses state-of-the-art algorithms for top-down identification through three distinct challenges. The first is identifying a large yield of PrSMs while controlling false discovery rate (FDR) in identifying thousands of proteoforms from complex cell lysates via four software workflows: ProSight Proteome Discoverer, TopPIC, Informed Proteomics, and pTop. The second is the deconvolution of data from both Thermo Orbitrap-class and Bruker maXis Q-TOF instruments to produce consistent precursor charge and mass determinations while generating fragment mass lists to optimize identification. The third attempts to detect diverse post-translational modifications (PTMs) in proteoforms from cow milk and human ovarian tissue. The data demonstrate that existing software suites produce admirable sensitivity, in some cases identifying a third of collected tandem mass spectra with FDR controlled below 2%; the overlap in these PrSMs, however, illustrates real value in searching data with multiple search engines. Differences among identification workflows seem to result from each search algorithm incorporating its own deconvolution algorithm. By transmitting deconvolution data from multiple deconvolution routes (Thermo Xtract, Bruker Auto MSn, Mascot Distiller, TopFD, and FLASHDeconv) to the downstream TopPIC search algorithm, we were able to detect common causes of deconvolution disagreement. The detection of PTMs was very inconsistent among search algorithms, with some workflows suggesting as little as 1% of PrSMs from cow’s milk were singly-phosphorylated while other workflows found that 18% of PrSMs were singly-phosphorylated. Taken together, these results make a strong argument for top-down researchers to adopt a standard practice of analyzing each MS/MS experiment with at least two different search engines.

59 BASIC BIOLOGICAL SCIENCES↗

SPE-CZE-MS Quantifies Zeptomole Amounts of Phosphorylated Peptides

Capillary zone electrophoresis (CZE) is gaining attention in the field of single-cell proteomics for its ultralow-flow and high-resolution separation abilities. Even more sample-limited yet rich in biological information are phosphoproteomics experiments, as the phosphoproteome composes only a fraction of the whole cellular proteome. Rapid analysis, high sensitivity, and maximization of sample utilization are paramount for single-cell analysis. Some challenges of coupling CZE analysis with mass spectrometry analysis (MS) of complex mixtures include 1. sensitivity due to volume loading limitations of CZE and 2. incompatibility of MS duty cycles with electropherographic time scales. Here, we address these two challenges as applied to singlecell- equivalent phosphoproteomics experiments by interfacing a microchip-based CZE device integrated with a solid-phaseextraction (SPE) bed with the Orbitrap Astral mass spectrometer. Using 225 phosphorylated peptide standards and phosphorylated peptide-enriched mouse brain tissue, we investigate microchip-based SPE-CZE functionality, quantitative performance, and complementarity to nano-LC-MS (nLC-MS) analysis. We highlight unique SPE-CZE separation mechanisms that can empower fitfor- purpose applications in single-cell-equivalent phosphoproteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme Molecular Complexity Resulting in a Continuum of Carbonaceous Species in Biomass Burning Tar Balls from Wildfire Smoke

Biomass burning emits a wide range of carbonaceous particles into the atmosphere and has negative impacts on human health and the Earth’s radiative balance. Nonvolatile spherical organic aerosol particles, commonly known as tar balls, represent one of the most abundant particles in aged biomass burning smoke. However, the detailed molecular-level composition of ambient tar balls is largely unknown but critical to access their environmental impacts. Ambient aerosol samples collected during a wildfire event, which were ~90% tar balls by number fraction, were analyzed using ultrahigh resolution Orbitrap Elite mass spectrometry with four complementary ionization modes. Our results show the molecular composition of tar balls to be complex, composed of over 10,000 molecular formulas. Model estimated saturation mass concentrations and relative humidity dependent glass transition temperatures were consistent with low volatility and solid morphology as expected for tar balls. Room-temperature evaporation kinetics showed that these particles were composed of ~90% non-volatile species. The molecular complexity detected here signifies a continuum of carbonaceous species, ranging from C3 to C45 with continuous ranges of oxygenation and hydrogen saturation for each Cn. Approximately 24% of molecular formulas were estimated the be highly aromatic, which could indicate chemical compounds with negative health effects, and which may contribute to visible light absorption. The carbon continuum observed here has significant implications for the molecular characterization of atmospheric organic matter. The level of complexity detected here should not be ignored in future studies and we demonstrate that multiple analytical methods may be required to suitably interpret this complexity on a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Native Top-Down Mass Spectrometry Characterization of Model Integral Membrane Protein Bacteriorhodopsin

Bacteriorhodopsin (bR) from Halobacterium salinarum has been a model system for structural biology and is a structural template for the characterization of membrane G-protein couple receptors (GPCRs) in particular. Here, in this study, wild-type bacteriorhodopsin and two single-residue mutants were characterized by native top-down mass spectrometry (nTD-MS) with Orbitrap-based high-energy collision dissociation (HCD) and electron capture dissociation (ECD). After in-source dissociation ejected the membrane protein from detergent micelles, high-resolution native MS measurement allowed for identification of multiple proteoforms as well as lipid-bound forms. Further top-down MS measurements by HCD produced a large number of product ions for in-depth sequencing and unambiguous localization of post-translational modifications. For the first time, native TD-MS with ECD was used to characterize an integral membrane protein. ECD yielded fragments originating from all helices and loop regions, even accessing a sequence stretch that HCD could not. Combining HCD and ECD fragmentation patterns significantly enhanced the sequence coverage of bR. We propose bR to be a model analyte for testing nTD-MS performance for membrane proteins.

crystal cleavage↗

Rapid Generation of Tandem Mass Spectrometry Reference Libraries Using Immediate Drop-on-Demand Liquid Handling Coupled to an Open Port Sampling Interface

In metabolomics, tandem MS (MS2) fragmentation libraries are important for the identification of unknown features, but generating these libraries takes many valuable hours of instrument and operator time. Here, an immediate droplet-on-demand/open port sampling interface was used to rapidly acquire tandem MS of standards arrayed in a 96-well plate format. A workflow was developed for automated, high-throughput control of MS2 library generation. Pure standard mass spectral libraries were collected on Orbitrap and Q-TOF mass spectrometers for 192 compounds using 6 different collision energies with a throughput of 4 and 7.8 s/spectrum, respectively. Libraries were acquired using different solvent additives, precursor adducts, and ion polarities.

Cahill, John [ORNL] (ORCID:0000000298664010)↗

Ultrasensitive single-cell proteomics workflow identifies >1000 protein groups per mammalian cell

Here, we report on the combination of nanodroplet sample preparation, ultra-low-flow nanoLC, high-field asymmetric ion mobility spectrometry (FAIMS), and the latest-generation Orbitrap Eclipse Tribrid mass spectrometer for greatly improved single-cell proteome profiling. FAIMS effectively filtered out singly charged ions for more effective MS analysis of multiply charged peptides, resulting in an average of 1056 protein groups identified from single HeLa cells without MS1-level feature matching. This is 2.3 times more identifications than without FAIMS and a far greater level of proteome coverage for single mammalian cells than has been previously reported for a label-free study. Differential analysis of single microdissected motor neurons and interneurons from human spinal tissue indicated a similar level of proteome coverage, and the two subpopulations of cells were readily differentiated based on single-cell label-free quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Sticky roots--implications of widespread, cryptic, viral infection of plants in natural and managed ecosystems for soil carbon processing in the rhizosphere

Plants strongly influence soil properties through rhizodeposition, in which exudates diffuse from roots, additional secretions are actively released, and root cells are sloughed into the soil. This contribution by plants of carbon compounds belowground is at the core of soil health, water holding capacity, and the soil carbon storage that pulls carbon dioxide out of the atmosphere. Once in soil, organic matter can bind with minerals such as iron hydroxides, where it can be protected from microbial attack for millenia, preserving very large terrestrial soil carbon pools. However, those same compounds contributed by roots to soil may also destabilize the long-term protective associations of SOM with minerals, making that soil organic matter (SOM) more vulnerable to microbial attack and decomposition. Plant roots thus influence both the buildup and breakdown of soil carbon pools. DOE’s E3SM Land Model (ELM) includes a representation of soil carbon storage on minerals, but the potential vulnerability of SOM–mineral associations to effects of rhizodeposition is not yet represented in ELM. To begin testing for this effect of rhizodeposition on soil carbon storage and decomposition, we worked to develop a novel approach during this TES Exploratory project DE-SC0019142 – we harnessed the power of plant viral infection. We examined whether plant virus infection can serve as a tool to intensify rhizodeposition at the root surface, and therefore possibly intensify mobilization of SOM from minerals making it visible to our analytical techniques. Viral infection is widespread in terrestrial ecosystems; 25-70% of plants have virus infection, yet the influence of such infection on root traits and terrestrial soil carbon dynamics remains largely unexplored. We used two plant hosts: the annual Avena sativa (oats) and the genetically tractable, model grass Brachypodium distachyon. These grasses were infected with the broad host range virus Barley Yellow Dwarf Virus (BYDV) via aphids (Rhopalosiphum padi). BYDV infects at least 150 grass species in agricultural and natural ecosystems, and in previous experiments, oats infected with BYDV had roots that were very sticky to the touch, strongly suggesting that infection altered rhizodeposition. We developed this new experimental approach mostly in a one virus (Barley Yellow Dwarf Virus)–one plant (Avena sativa) system. (Several effects of infection in a Brachypodium-BYDV system were similar in nature to effects on Avena sativa, but were more variable.) In the BYDV-Avena system, we developed protocols for consistently infecting target plants (and avoiding infection of control plants) using aphid caging on leaves. We measured that infected plants exhibited reduced photosynthesis, plant (including root) biomass, and root:shoot ratio, as well as simplified root system architecture. We established procedures for sampling the organic compounds carried specifically in phloem (vascular tissue) of leaves and roots, using aphid stylectomy. We used FTICR-MS, Orbitrap GC-MS, and LC-MS/MS to analyze organic compounds in phloem, liquid around roots of plants grown hydroponically, and pore water around roots in soil, and found differences in the compounds in solution bathing roots when infected and uninfected plants were grown hydroponically. Finally, we synthesized isotopically-labeled mineral–organic matter (MAOM) associations in the lab and developed assays using them in solution and in soil. Assays quantified the extent and rate of mineralization of labeled MAOM that was mobilized by functionally distinct rhizodeposits and then attacked by microbes. Two mechanisms for MAOM mobilization emerged, with distinct dynamics. During “direct” mobilization, rhizodeposits such as the strong ligand oxalic acid could drive rapid dissolution of minerals, mobilizing MAOM. During “indirect” mobilization, rhizodeposits such as the simple sugar glucose did not attack minerals directly but instead intensified microbial activity, which led to mobilization via changes in e.g. pH, Eh, and microbial metabolite production (Li et al. 2021). Mechanistic understanding derived from these data and our ongoing experiments using these techniques will inform future development of ELM. Plant roots not only contribute newly fixed organic compounds to soils, but also root activities can drive mineralization of the carbon and nutrients mobilized off minerals via “indirect” or “direct” mechanisms. Using viral infection as a new tool, ongoing combined experimentation and modeling will explore the strength and larger-scale significance of the cascade of processes from rhizodeposition to MAOM mobilization for soil carbon storage and nutrient cycling in terrestrial ecosystems. And if viral infection leads quite generally to “sticky roots”, our perception of the potential importance of prevalent virus infection in terrestrial landscapes will be transformed.

54 ENVIRONMENTAL SCIENCES↗

Characterizing the contribution of bioaerosols diversity from complex aerosol particle samples.

Current global change scenarios expect to significantly increase the contribution of pollen to the total organic aerosol budget. In addition, pollen can burst into smaller fragments that are highly efficient as cloud condensation nuclei. However, current climate models still do not incorporate the effects of these particles due to detection and quantification challenges in complex aerosol mixtures. Chemical biomarkers (i.e. fructose) have commonly been used to trace pollen but this approximation can generate false positive results given the large number of shared compounds between different bioaerosols. A previous pilot EMSL experiment performed on pure pollen samples suggested that using a set of metabolites as a fingerprint of bioaerosols could serve to substantially increase detection accuracy over single biomarker approaches. In this proposal we developed novel bioinformatic strategies to characterize and quantify complex pollen mixtures present in the atmosphere. For that, we used diverse machine learning algorithms to analyze metabolic fingerprints from complex mixtures of different pollen acquired with high-resolution mass spectrometry (Orbitrap Q-Exactive). Our preliminary results demonstrated the potential to accurately discern and identify at specific relative abundances different pollen species in complex mixtures. Our research will lead to a significant advancement in the atmospheric chemistry and provide much needed data to improve the accuracy of climate models.

54 ENVIRONMENTAL SCIENCES↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial Co-Culture Control Proteomics (MC-DP1)

Co-cultured S. elongatus PCC 7942 CscB/SPS and R. toruloides IFO0880 presented as an effective photosynthesis-driven biofuel production platform. The goal of this experiment was to understand the molecular mechanism of this co-culture system at redox post-translational modification level. The redox proteome of the co-cultured strains was compared to a mono-cultured S. elongatus in light or dark conditions. Samples were processed using a resin-assisted capture (RAC) workflow with TMT labeling to enrich and quantify modified cysteines at proteome level. The datasets were generated by a Q Exactive Plus Orbitrap Mass Spectrometer coupled with a Waters nanoAcquity UPLC, then searched by MSGF+ for downstream redox PTM analysis.

Source record↗