Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optimal Zone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spectroscopic analysis on the basis of Judd–Ofelt theory along [0 0 1] of Er:YVO{sub 4} grown by optical floating zone technique

Highlights: ► Synthesis and solid state reaction for Er:YVO{sub 4} is addressed. ► Single crystal growth by OFZ technique along c [0 0 1] is discussed. ► Differences in crystal morphology along a and c axes are experimentally observed. ► This is explained on the basis of difference in attachment energy. ► Spectroscopic investigations along [0 0 1] are carried out. - Abstract: 1.0 at.% erbium-doped YVO{sub 4} crystals have been grown along [0 0 1] by optical floating zone technique after optimizing the synthesis process. The circular cross-section of the grown crystals is explained on the basis of attachment energy. Using Judd–Ofelt (JO) theory the absorption and emission lines observed in absorption and photoluminescence data along [0 0 1] are characterized. JO intensity parameters as calculated are: Ω{sub 2} = 14.4389 × 10{sup −20} cm{sup 2}, Ω{sub 4} = 2.3320 × 10{sup −20} cm{sup 2} and Ω{sub 6} = 1.7794 × 10{sup −20} cm{sup 2}. For {sup 4}I{sub 13/2} → {sup 4}I{sub 15/2} transition the calculated radiative lifetime and emission cross-section are: 2.59 × 10{sup −20} cm{sup 2} and 2.45 ms, respectively.

36 MATERIALS SCIENCE↗

The Industrial Sodium Cooled Fast Reactor

This paper investigates the use of enrichment and moderator zoning methods for optimizing the r-z power distribution within sodium cooled fast reactors. These methods allow overall greater fuel utilization in the core resulting in more fuel being irradiated near the maximum allowed thermal power. The peak-to-average power density was held to 1.18. This core design, in conjunction with a multiple-reheat Brayton power conversion system, has merit for producing an industrial level of electrical output (2400MWth, 1000MWe) from a relatively compact core size. The total core radius, including reflectors and shields, was held to 1.78m. Preliminary safety analysis suggests that positive reactivity insertion resulting from a leak between the sodium primary loop and helium power conversion system can be mitigated using simple gas-liquid centripetal separation strategies in the plant’s primary loop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FIELD TEST INSTRUCTION 100-NR-2 OPERABLE UNIT DESIGN OPTIMIZATION STUDY FOR SEQUESTRATION OF SR-90 SATURATED ZONE APATITE PERMEABLE REACTIVE BARRIER EXTENSION

The objective of this field test instruction is to provide technical guidance for aqueous injection emplacement of an extension apatite permeable reactive barrier (PRE) for the sequestration of strontium-90 (Sr-90) using a high concentration amendment formulation. These field activities will be conducted according to the guidelines established in DOE/RL-2010-29, 100-NR-2 Design Optimization Study, hereafter referred to as the DOS. The DOS supports the Federal Facility Agreement Consent Order (EPA et al., 1989), Milestone M-16-06-01, and 'Complete Construction of a Permeable Reactive Barrier at 100-N.' Injections of apatite precursor chemicals will occur at an equal distance intervals on each end of the existing PRE to extend the PRB from the existing 91 m (300 ft) to at least 274 m (900 ft). Field testing at the 100-N Area Apatite Treatability Test Site, as depicted on Figure 1, shows that the barrier is categorized by two general hydrologic conceptual models based on overall well capacity and contrast between the Hanford and Ringold hydraulic conductivities. The upstream portion of the original barrier, shown on Figure 1, is characterized by relatively low overall well specific capacity. This is estimated from well development data and a lower contrast in hydraulic conductivity between the Hanford formation and Ringold Formations. Comparison of test results from these two locations indicate that permeability contrast between the Hanford formation and Ringold Formation is significantly less over the upstream one-third of the barrier. The estimated hydraulic conductivity for the Hanford formation and Ringold Formation over the upstream portion of the barrier based on observations during emplacement of the existing 91 m (300 ft) PRB is approximately 12 and 10 m/day (39 and 32 ft/day), respectively (PNNL-17429). However, these estimates should be used as a rough guideline only, as significant variability in hydraulic conductivity is likely to be observed in the barrier extension wells, particularly those in the Ringold formation. The downstream portion of the original barrier, shown on Figure 1, is characterized by generally higher well specific capacity and a larger hydraulic conductivity contrast between the Hanford formation and Ringold Formation. Hydraulic conductivity rates for the Hanford formation and Ringold Formation over the downstream portion of the barrier were estimated at 29 and 9 m/day (95 and 29 ft/day), respectively (with the Hanford formation hydraulic conductivity being greater in the downstream portion than the upstream portion). Once again, it should be noted that the actual conductivities may vary significantly, and the values state above should only be used as a rough initial estimates. Optimum apatite emplacement has been shown to occur when injections targeting the Hanford formation and the Ringold Formation are performed separately. The remainder of this test instruction provides details for conducting these formation-targeted injections.

58 GEOSCIENCES↗

Simulations of CO 2 injection into fractures and faults for improving their geophysical characterization at EGS sites

Here, we propose the use of CO 2 in push-pull well tests to improve geophysical identification and characterization of fractures and faults at enhanced geothermal system (EGS) sites. Using TOUGH2/ECO2N, we carried out numerical experiments of push-pull injection-production cycling of CO 2 into idealized vertical fractures and faults to produce pressure-saturation-temperature conditions that can be analyzed for their geophysical response. Our results show that there is a strong difference between injection and production mainly because of CO 2 buoyancy. While the CO 2 -plume grows laterally and upward during injection, not all CO 2 is recovered during the subsequent production phase. Even under the best conditions for recovery, at least 10% of the volume of the pores still remains filled with CO 2 . To improve EGS characterization, comparisons can be made of active seismic methods carried out before and after (time lapse mode) CO 2 injection into the fracture or fault. Here we find that across the CO 2 saturation range, C11 (the normal stiffness in the horizontal direction perpendicular to the fracture plane) varies between maximum and minimum values by about 15%. It reaches a maximum at around 6% gas saturation, decreasing exponentially to a minimum at higher saturations. Finally, our results suggest that CO 2 injection can be effectively used to infiltrate fault and fracture zones reaching about optimal saturation values in order to enhance seismic imaging at EGS sites.

58 GEOSCIENCES↗

Highly efficient greenish-blue platinum-based phosphorescent organic light-emitting diodes on a high triplet energy platform

We have demonstrated high-efficiency greenish-blue phosphorescent organic light-emitting diodes (PHOLEDs) based on a dimesitylboryl-functionalized C^N chelate Pt(II) phosphor, Pt(m-Bptrz)(t-Bu-pytrz-Me). Using a high triplet energy platform and optimized double emissive zone device architecture results in greenish-blue PHOLEDs that exhibit an external quantum efficiency of 24.0% and a power efficiency of 55.8 lm/W. This record high performance is comparable with that of the state-of-the-art Ir-based sky-blue organic light-emitting diodes.

36 MATERIALS SCIENCE↗

Hierarchical Speed Planner for Automated Vehicles: A Framework for Lagrangian Variable Speed Limit in Mixed-Autonomy Traffic

Here, this article presents a novel hierarchical speed planning framework for variable speed limits in mixed-autonomy traffic environments, leveraging server-side macroscopic control and vehicle-side microscopic execution. The framework integrates real-time traffic state estimation (TSE) and reinforcement learning (RL)-based control to mitigate congestion and improve traffic flow. A TSE enhancement module combines macroscopic data from sources like INRIX with high-resolution observations from connected autonomous vehicles (CAVs), enabling predictive modeling to address latency and noise. The target speed design module employs kernel smoothing and a buffer zone strategy to optimize traffic density and flow around bottlenecks. The proposed system was validated in the largest open-road test to date with 100 CAVs, demonstrating an overall 8% traffic density decrease, with a specific decrease of 7% upstream, 10% downstream, and a 52% decrease during the congestion formation phase at bottlenecks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochromic Window Demonstration at the John E. Moss Federal Building, 650 Capitol Mall, Sacramento, California

Dynamic windows have the potential to provide real-time optimization of perimeter zone energy use, peak demand, comfort, amenity, and cost criteria on a seasonal or even minute-to- minute basis in response to weather, occupant or regional grid demands. Electrochromic (EC) windows, a type of dynamic window, have the ability to adjust their tint dynamically in response to a small applied voltage. In previous studies, they have shown potential to reduce heating, ventilation and air conditioning (HVAC) energy consumption and increase occupant satisfaction. This technology is available in the U.S. as a commercial product from multiple vendors with high-capacity manufacturing facilities, and could be broadly deployed if successful in a pilot test. This Green Proving Ground (GPG) program study examines the energy and comfort performance of EC windows in south-facing perimeter zones of a typical U.S. General Services Administration GSA office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transparent multi-zone crystal growth furnace and method for controlling the same

A crystal growth system, comprising: a furnace; a plurality of heating elements coupled to said furnace, each said plurality of heating elements defining a heat zone, each said heating element set to a desired temperature value; a plurality of thermocouples associated with respective heat zones to detect a temperature value; a translation system for passing an ampoule containing crystal growth material through said furnace into said heat zones and providing a positional location of said ampoule and; a multi-variable self-tuning temperature controller connected to said plurality of heating elements, said plurality of thermocouples and said translation system, said controller monitoring each said zone temperature value and upon considering the thermal interaction of heating zones and the moving thermal inertia of the ampoule, adjusting voltage input to said heat zones to obtain optimal crystal growth within said ampoule.

Duval, Walter↗

Transparent multi-zone crystal growth furnace and method for controlling the same

A crystal growth system, comprising: a furnace; a plurality of heating elements coupled to said furnace, each said plurality of heating elements defining a heat zone, each said heating element set to a desired temperature value; a plurality of thermocouples associated with respective heat zones to detect a temperature value; a translation system for passing an ampoule containing crystal growth material through said furnace into said heat zones and providing a positional location of said ampoule and; a multi-variable self-tuning temperature controller connected to said plurality of heating elements, said plurality of thermocouples and said translation system, said controller monitoring each said zone temperature value and upon considering the thermal interaction of heating zones and the moving thermal inertia of the ampoule, adjusting voltage input to said heat zones to obtain optimal crystal growth within said ampoule.

Duval, Walter↗

Deconvolution Methods and Systems for the Mapping of Acoustic Sources from Phased Microphone Arrays

Mapping coherent/incoherent acoustic sources as determined from a phased microphone array. A linear configuration of equations and unknowns are formed by accounting for a reciprocal influence of one or more cross-beamforming characteristics thereof at varying grid locations among the plurality of grid locations. An equation derived from the linear configuration of equations and unknowns can then be iteratively determined. The equation can be attained by the solution requirement of a constraint equivalent to the physical assumption that the coherent sources have only in phase coherence. The size of the problem may then be reduced using zoning methods. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with a phased microphone array (microphones arranged in an optimized grid pattern including a plurality of grid locations) in order to compile an output presentation thereof, thereby removing beamforming characteristics from the resulting output presentation.

Brooks, Thomas F.↗

Conceptual design of inverted core lead bismuth eutectic fast reactor for marine applications

The development of an inverted core fast reactor aims to generate 60 MWth for about 30 Effective Full Power Years without refueling. The reactor design is a transportable reactor using UO{sub 2} fuel and lead-bismuth-eutectic cooled designed for marine applications and is intended to improve the reactor performances compared to the normal core design: better condition for passive cooling system capability by lower core pressure drop, taking advantage of potential power uprate from the lower maximum fuel temperature. Systematic design processes are presented in this work: fuel pin geometry selection, fuel assembly (FA) design, and core design. A relationship between pressure drops, coolant velocity, maximum fuel temperature, coolant channel diameter, and fuel volume fraction was introduced in a single graph used as a tool to select fuel pin geometry. Fuel fabrication capability also took place in consideration of FA design which led to 7 holes per FA, and two-dimensional temperature distribution studies were also carried out. Core design processes including radial zoning, axial zoning, and core optimization were conducted using Monte Carlo code MCS, which is UNIST CORE laboratory in-house code. The current core design uses 3 fuel enrichment levels and 3 FA types to control the local power distribution and power shift during its lifetime. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flexible atomic layer deposition system for coating porous materials

In this paper, we describe an atomic layer deposition (ALD) system that is optimized for the growth of thin films on high-surface-area, porous materials. The system incorporates a moveable dual-zone furnace allowing for rapid transfer of a powder substrate between heating zones whose temperatures are optimized for precursor adsorption and oxidative removal of the precursor ligands. The reactor can both be evacuated, eliminating the need for a carrier gas during precursor exposure, and rotated, to enhance contact between a powder support and the gas phase, both of which help us to minimize mass transfer limitations in the pores during film growth. The capabilities of the ALD system were demonstrated by growing La 2 O 3 , Fe 2 O 3 , and LaFeO 3 films on a 120 m 2 g -1 MgAl 2 O 4 powder. Analysis of these films using scanning transmission electron microscopy and temperature-programmed desorption of 2-propanol confirmed the conformal nature of the oxide films.

36 MATERIALS SCIENCE↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Stable Geometry of a Plane Five-Link Mechanism

A five-link mechanism of parallel structure with rotary kinematic pairs is considered. Possible configurations of the mechanism, its working regions, and singular positions are discussed. Possible optimization of its working zone without singular positions of the second kind is analyzed.

42 ENGINEERING↗

Optimal Piecewise Linear Basis Functions in Two Dimensions

We use a variational approach to optimize the center point coefficients associated with the piecewise linear basis functions introduced by Stone and Adams [1], for polygonal zones in two Cartesian dimensions. Our strategy provides optimal center point coefficients, as a function of the location of the center point, by minimizing the error induced when the basis function interpolation is used for the solution of the time independent diffusion equation within the polygonal zone. By using optimal center point coefficients, one expects to minimize the errors that occur when these basis functions are used to discretize diffusion equations, or transport equations in optically thick zones (where they approach the solution of the diffusion equation). Our optimal center point coefficients satisfy the requirements placed upon the basis functions for any location of the center point. We also find that the location of the center point can be optimized, but this requires numerical calculations. Curiously, the optimum center point location is independent of the values of the dependent variable on the corners only for quadrilaterals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anisotropic Elastic-Waveform Modeling for Fracture Characterization in EGS Reservoirs

Enhanced geothermal systems (EGS) contain newly created fractures in addition to possible existing fractures. Accurate characterization and monitoring of EGS reservoirs are crucial for optimal placement of new wells and effective extraction of geothermal heat. The fractured reservoirs behave as anisotropic media where seismic waves propagate with different velocities along different directions. In addition, the anisotropic properties of fluid-filled fracture zones could be different from those of dry fracture zones. We develop an optimized rotated staggered-grid elastic-wave finite-difference method for simulating seismic-wave propagation in heterogeneous, anisotropic media. Our new method uses a few extra grid points and optimized finite-difference coefficients based on the space-time dispersion relation, and reduce numerical dispersion of the conventional rotated staggered-grid finite-difference scheme. We validate our new method using synthetic vertical-seismic-profiling (VSP) data for an anisotropic geophysical model built with geologic features found at the Raft River EGS reservoir. This improved and optimized rotated staggered-grid finite-difference method provides an essential tool for analyzing VSP data, reverse-time migration, and elastic-waveform inversion in anisotropic, fractured reservoirs.

58 GEOSCIENCES↗