Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutron, fluorescence, and optical imaging: An in situ combination of complementary techniques

An apparatus which enables the simultaneous combination of three complementary imaging techniques, optical imaging, fluorescence imaging, and neutron radiography, is presented. While each individual technique can provide information on certain aspects of the sample and their time evolution, a combination of the three techniques in one setup provides a more complete and consistent data set. The setup can be used in transmission and reflection modes and thus with optically transparent as well as opaque samples. Its capabilities are illustrated with two examples. A polymer hydrogel represents a transparent sample and the diffusion of fluorescent particles into and through this polymer matrix is followed. In reflection mode, the absorption of solvent by a nile red-functionalized mesoporous silica powder and the corresponding change in fluorescent signal are studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electro-Optical Measurement Techniques

Utilize the unique characteristics of photons across different regions of the electromagnetic spectrum to probe the optical and electronic properties of chemical systems, materials and devices for energy conversion technologies.

absorption↗

Spatial Temporal Image Correlation Spectroscopy (STICS) for Flow Analysis with Application for Blood Flow Mapping

It is important for surgeons to be able to measure blood flow in exposed arterioles during surgery. We report our progress in the development of an optical technique that will measure blood flow in surgically exposed blood vessels and enable previously difficult measurements. By monitoring optical fluctuations, the optical technique, based on Spatial Temporal Image Correlation (STICS), will directly measure the velocity of micron-scale particles--such as red blood cells. It will complement existing technology and provide qualitative measurements that were not previously possible. It relies on the concept that blood, when viewed on a small enough scale, is an inhomogeneous substance. Individual blood cells passing between a near-infrared light source and a detector will cause fluctuations in the transmitted optical signal. The speed, direction, and flow pattern of blood cells can be determined from these optical fluctuations. We present a series of computer simulations and experiments on phantom and animal systems to test this technique's ability to map complex flow patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cooled Spray Technology for Particulate Reduction in a Heavy-Duty Engine

Cooled spray (CS) technology passively reduces particulate matter (PM) emissions from diesel engines compared to non-CS-equipped diesel engines. CS inserts are mounted near the injector nozzle and control mixing so that the fuel and air can premix while limiting combustion near fuel-rich zones, thereby reducing the formation of particulate matter. CS components contain no moving parts and could be installed as a retrofit or built into new engines. However, CS technology is early in its development, and further investigations are needed to understand the overall performance implications and practicality of the technology. In this paper, we investigate several important aspects of CS, providing a clearer picture of some challenges and potential benefits of CS. Two alignment techniques are used to characterize measurement ease and bias, namely, an optical alignment and spray-plug impact alignment. While the optical technique facilitates alignment more easily, a bias was measured between the optical and spray-plug techniques, suggesting the optical technique may have insufficient accuracy without additional corrections. We also evaluate the engine performance of a well-aligned and poorly aligned CS insert, compared to the baseline configuration. The poorly aligned insert shows slower combustion than the baseline and mixed overall performance. However, the well-aligned insert shows faster combustion than the baseline and PM emission reduction at most operating conditions, with some conditions showing PM reduction up to 80%. Furthermore, the results of this paper highlight the alignment challenges of CS technology as well as the potential PM reduction benefit of the technology.

33 ADVANCED PROPULSION SYSTEMS↗

Fringe biasing: A variance reduction technique for optically thick meshes

Fringe biasing is a stratified sampling scheme applicable to Monte Carlo thermal radiation transport codes. The thermal emission source in optically thick cells is partitioned into separate contributions from the cell interiors (where the likelihood of the particles escaping the cells is virtually zero) and the 'fringe' regions close to the cell boundaries. Thermal emission in the cell interiors can now be modelled with fewer particles, the remaining particles being concentrated in the fringes so that they are more likely to contribute to the energy exchange between cells. Unlike other techniques for improving the efficiency in optically thick regions (such as random walk and discrete diffusion treatments), fringe biasing has the benefit of simplicity, as the associated changes are restricted to the sourcing routines with the particle tracking routines being unaffected. This paper presents an analysis of the potential for variance reduction achieved from employing the fringe biasing technique. The aim of this analysis is to guide the implementation of this technique in Monte Carlo thermal radiation codes, specifically in order to aid the choice of the fringe width and the proportion of particles allocated to the fringe (which are interrelated) in multi-dimensional simulations, and to confirm that the significant levels of variance reduction achieved in simulations can be understood by studying the behaviour for simple test cases. The variance reduction properties are studied for a single cell in a slab geometry purely absorbing medium, investigating the accuracy of the scalar flux and current tallies on one of the interfaces with the surrounding medium. (authors)

97 MATHEMATICS AND COMPUTING↗

Experimental comparison of particle interaction measurement techniques using optical traps.

Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the linewidth enhancement factor of mid-infrared quantum cascade lasers by different optical feedback techniques

Precise knowledge of the linewidth enhancement factor of a semiconductor laser under actual operating conditions is of prime importance since this parameter dictates various phenomena such as linewidth broadening or optical nonlinearities enhancement. The above-threshold linewidth enhancement factor of a mid-infrared quantum cascade laser structure operated at 10{sup ∘}C is determined experimentally using two different methods based on optical feedback. Both Fabry-Perot and distributed feedback quantum cascade lasers based on the same active area design are studied, the former by following the wavelength shift as a function of the feedback strength and the latter by self-mixing interferometry. The results are consistent and unveil a clear pump current dependence of the linewidth enhancement factor, with values ranging from 0.8 to about 3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic near-field optical interaction between oscillating nanomechanical structures

Near-field optical techniques exploit light-matter interactions at small length scales for mechanical sensing and actuation of nanomechanical structures. Here, we study the optical interaction between two mechanical oscillators—a plasmonic nanofocusing probe-tip supported by a low frequency cantilever, and a high frequency nanomechanical resonator—and leverage their interaction for local detection of mechanical vibrations. The plasmonic nanofocusing probe provides a confined optical source to enhance the interaction between the two oscillators. Dynamic perturbation of the optical cavity between the probe-tip and the resonator leads to nonlinear modulation of the scattered light intensity at the sum and difference of their frequencies. This double-frequency demodulation scheme is explored to suppress unwanted background and to detect mechanical vibrations with a minimum detectable displacement sensitivity of 0.45pm/Hz 1/2 , which is limited by shot noise and electrical noise. We explore the demodulation scheme for imaging the bending vibration mode shape of the resonator with a lateral spatial resolution of 20nm. We also demonstrate the time-resolved aspect of the local optical interaction by recording the ring-down vibrations of the resonator at frequencies of up to 129MHz. The near-field optical technique is promising for studying dynamic mechanical processes in individual nanostructures.

36 MATERIALS SCIENCE↗

A Review of Advanced Characterization Methods and Techniques for Amorphous and Poorly Crystalline Materials Applicable to Cementitious Waste Forms

This review covers advanced characterization methods of cementitious materials. The particular focus is to understand cementitious compositions with amorphous content because conventional techniques such as X-ray diffraction are more applicable to materials with long range order. Also of interest is advanced characterization that provides deeper insights into properties such as porosity. There are five groups of characterization methods discussed in this review which are: electron beam/microscopy, X-ray, neutron diffraction and scattering, nuclear magnetic resonance, and optical techniques. The techniques can be further grouped by the categories of nanoscale structural understanding (transmission electron microscopy and pair distribution function), microscale structural understanding (focused ion beam and x-ray tomography), microscopic elemental distributions (energy dispersive spectroscopy and X-ray fluorescence), and chemical binding information (electron energy loss spectroscopy, x-ray absorption spectroscopy, nuclear magnetic resonance, Raman spectroscopy, and infrared spectroscopy), with advantages and disadvantages of each method discussed. The recommendation for further research is to begin with techniques that are easier to prepare samples for, measure, and analyze, such as the optical techniques of Raman and infrared spectroscopy. If more information is needed, pursue collaborations, other techniques, or proposals for beam time at the synchrotron sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Drag Reduction by Laser-Plasma Energy Addition in Hypersonic Flow

An experimental study was conducted to investigate the drag reduction by laser-plasma energy addition in a low density Mach 7 hypersonic flow. The experiments were conducted in a shock tunnel and the optical beam of a high power pulsed CO{sub 2} TEA laser operating with 7 J of energy and 30 MW peak power was focused to generate the plasma upstream of a hemispherical model installed in the tunnel test section. The non-intrusive schlieren optical technique was used to visualize the effects of the energy addition to hypersonic flow, from the plasma generation until the mitigation of the shock wave profile over the model surface. Aside the optical technique, a piezoelectric pressure transducer was used to measure the impact pressure at stagnation point of the hemispherical model and the pressure reduction could be observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of an optical mixing technique to drive Kinetic Electrostatic Electron Nonlinear waves in laser produced plasmas

A nitrogen Raman system has been constructed to shift a 70 J 527 nm laser beam to 600 nm with 20 J of energy. The 600 nm probe and a 200J, 527 nm pump beam are optically mixed in a laser produced (gas jet) plasma. The beating of the two laser beams forms a ponderomotive force that can dto drive Kinetic Electrostatic Electron Nonlinear (KEEN) waves discovered in Vlasov-Poisson simulations. KEEN waves were detected in these experiments where traditional plasma theory would declare there to be a spectral gap (ie no waves possible). The detection was done using Thomson scattering with probe wavelengths of both 351 nm and 263.5 nm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terahertz cyclotron resonance spectroscopy of an AlGaN/GaN heterostructure using a high-field pulsed magnet and an asynchronous optical sampling technique

The effective mass, sheet carrier concentration, and mobility of electrons within a two-dimensional electron gas in an AlGaN/GaN heterostructure were determined using a laboratory-based terahertz cyclotron resonance spectrometer. The ability to perform terahertz cyclotron resonance spectroscopy with magnetic fields of up to 31 T was enabled by combining a high-field pulsed magnet with a modified asynchronous optical sampling terahertz detection scheme. This scheme allowed around 100 transmitted terahertz waveforms to be recorded over the 14 ms magnetic field pulse duration. The sheet density and mobility were measured to be 8.0 × 10{sup 12 }cm{sup −2} and 9000 cm{sup 2} V{sup −1} s{sup −1} at 77 K. The in-plane electron effective mass at the band edge was determined to be 0.228 ± 0.002m{sub 0}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Innovative nanopore sequencing technology including a self-assembled porous membrane

Methods and apparatus for long read, label-free, optical nanopore long chain molecule sequencing. In general, the present disclosure describes a novel sequencing technology based on the integration of nanochannels to deliver single long-chain molecules with widely spaced (>wavelength), ˜1-nm aperture “tortuous” nanopores that slow translocation sufficiently to provide massively parallel, single base resolution using optical techniques. A novel, directed self-assembly nanofabrication scheme using simple colloidal nanoparticles is used to form the nanopore arrays atop nanochannels that unfold the long chain molecules. At the surface of the nanoparticle array, strongly localized electromagnetic fields in engineered plasmonic/polaritonic structures allow for single base resolution using optical techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovative nanopore sequencing technology including a self-assembled porous membrane

Methods and apparatus for long read, label-free, optical nanopore long chain molecule sequencing. In general, the present disclosure describes a novel sequencing technology based on the integration of nanochannels to deliver single long-chain molecules with widely spaced (>wavelength), ˜1-nm aperture “tortuous” nanopores that slow translocation sufficiently to provide massively parallel, single base resolution using optical techniques. A novel, directed self-assembly nanofabrication scheme using simple colloidal nanoparticles is used to form the nanopore arrays atop nanochannels that unfold the long chain molecules. At the surface of the nanoparticle array, strongly localized electromagnetic fields in engineered plasmonic/polaritonic structures allow for single base resolution using optical techniques.

Brueck, Steven R. J.↗

A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

Here, we report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas detector of the microbulk technology. The detector is made from radiopure materials and is placed at the focal point of a ~ 5 cm diameter, 1.5 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) assembled from thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. Furthermore, the combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4×10 –3 counts per hour in the energy region-of-interest and signal spot area.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a cosmic ray oriented trigger for the fluorescence telescope on EUSO-SPB2

The Extreme Universe Space Observatory on a Super Pressure Balloon 2 (EUSO-SPB2), in preparation, aims to make the first observations of Ultra-High Energy Cosmic Rays (UHECRs) from near space using optical techniques. EUSO-SPB2 will prototype instrumentation for future satellite-based missions, including the Probe of Extreme Multi-Messenger Astrophysics (POEMMA) and K-EUSO. The payload will consist of two telescopes. The first is a Cherenkov telescope (CT) being developed to quantify the background for future below-the-limb very high energy (E 10 PeV) astrophysical neutrino observations, and the second is a fluorescence telescope (FT) being developed for detection of UHECRs. The FT will consist of a Schmidt telescope, and a 6192 pixel ultraviolet camera with an integration time of 1.05 s. The first step in the data acquisition process for the FT is a hardware level trigger in order to decide which data to record. In order to maximize the number of UHECR induced extensive air showers (EASs) which can be detected, a novel trigger algorithm has been developed based on the intricacies and limitations of the detector. Finally, the expected performance of the trigger has been characterized by simulations and, pending hardware verification, shows that EUSO-SPB2 is well positioned to attempt the first near-space observation of UHECRs via optical techniques.

79 ASTRONOMY AND ASTROPHYSICS↗