Wind tunnel and flight development of spoilers for general aviation aircraft

Wind tunnel tests have been carried out to develop a spoiler lateral control system for use with the GA(W)-1 airfoil with a 30% Fowler flap. Tests show that unfavorable aerodynamic interactions can occur between spoiler and flap for large flap deflections. Providing venting of lower surface air through the spoiler opening substantially improves performance. Results of tests with a number of spoiler and cavity shapes are presented and discussed. Applications of two-dimensional wind tunnel results to the design of satisfactory manual lateral control systems are discussed.

Wentz, W. H., Jr.↗

Flight Test Data for Prototype Air-Ground Control and Non-Payload Communications Radio Link

Extensive flight testing was conducted over flat terrain, hilly terrain, and open freshwater settings to examine performance of an air-ground command and control radio link for unmanned aerial vehicles. The flight data collected on bidirectional radio range, signal fading, and transmitted data loss were necessary to validate a proposed air-ground radio waveform that was being considered by a U.S. standards organization. The NASA test system operated at C-band frequencies and utilized a prototype, software-defined radio developed in cooperation with a commercial avionics supplier. Results are presented for multiple altitudes, ranges, and flight conditions, indicating the signal fade depths, occurrence rates, and durations for each flight environment.

Kurt Shalkhauser↗

A Systems Approach to AI Model Integration and Performance Evaluation for the Generic UAM Simulation Framework

This paper introduces py-guam, an open-source experimentation framework developed for the NASA Generic Urban Air Mobility simulation (GUAM) environment, facilitating the integration and evaluation of advanced artificial intelligence (AI) algorithms. We present a systems approach which enables the seamless incorporation of data-driven models, including off-nominal and failure state detection, into the GUAM’s Cognitive Architecture (CA). The framework supports customizable experimentation parameters, derives Safety Performance Indicators (SPIs) from UL 4600 safety case analyses, and employs rapid UAM simulations to assess AI impacts on flight performance across diverse scenarios. Through comprehensive testing and validation experiments, we demonstrate GUAM’s capability to enhance safety and efficiency in urban air mobility operations. Additionally, the open-source nature of py-guam fosters community collaboration, ensuring continuous improvement and adaptability to evolving technological advancements. This work establishes a robust tool for developing and testing AI-driven urban air mobility (UAM) systems, advancing the safety and reliability of autonomous urban air vehicles.

Artificial Intelligence↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Volatile aldehyde emissions from “sub-ohm” vaping devices

"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The external gamma radiation environment from the Kiwi Phoebus, and Pewee reactors

During the past few years, ground tests of high-powered propulsion-prototype reactors have provided several opportunities to observe the external radiation environment. Reactor tests have been conducted in free air and inside of open well shields. Measurements were taken over distances ranging from contact with the pressure vessel out to greater than 5000' both during operation and after shutdown. Some measurements characteristic of each of the systems are presented and compared with results of calculations.

Malenfant, R. E.↗

Full-Scale Wind-Tunnel Tests on Several Metal Propellers Having Different Blade Forms

This report gives the full-scale aerodynamic characteristics of five different aluminum alloy propellers having four different blade forms. They were tested on an open cockpit fuselage with a radial air-cooled engine having conventional cowling. The results show that (1) the differences in propulsive efficiency due to the differences in blade form were small; (2) the form with the thinnest airfoil sections had the highest efficiency; (3) it is advantageous as regards propulsive efficiency for a propeller operating in front of a body, such as a radial engine, to have its pitch reduced toward the hub.

Weick, Fred E↗

Solar Tower Experiments for Radiometric Calibration and Validation of Infrared Imaging Assets and Analysis Tools for Entry Aero-Heating Measurements

The NASA Engineering and Safety Center sponsored Hypersonic Thermodynamic Infrared Measurements assessment team has a task to perform radiometric calibration and validation of land-based and airborne infrared imaging assets and tools for remote thermographic imaging. The IR assets and tools will be used for thermographic imaging of the Space Shuttle Orbiter during entry aero-heating to provide flight boundary layer transition thermography data that could be utilized for calibration and validation of empirical and theoretical aero-heating tools. A series of tests at the Sandia National Laboratories National Solar Thermal Test Facility were designed for this task where reflected solar radiation from a field of heliostats was used to heat a 4 foot by 4 foot test panel consisting of LI 900 ceramic tiles located on top of the 200 foot tall Solar Tower. The test panel provided an Orbiter-like entry temperature for the purposes of radiometric calibration and validation. The Solar Tower provided an ideal test bed for this series of radiometric calibration and validation tests because it had the potential to rapidly heat the large test panel to spatially uniform and non-uniform elevated temperatures. Also, the unsheltered-open-air environment of the Solar Tower was conducive to obtaining unobstructed radiometric data by land-based and airborne IR imaging assets. Various thermocouples installed on the test panel and an infrared imager located in close proximity to the test panel were used to obtain surface temperature measurements for evaluation and calibration of the radiometric data from the infrared imaging assets. The overall test environment, test article, test approach, and typical test results are discussed.

Splinter, Scott C.↗

Influence Of Holes On The In-Plane Tensile Strength And Fatigue Durability Of A NICALON(Trademark)/Si-N-C Ceramic Matrix Composite

Effects of different sizes of holes as well as different percentages of open areas on the in-plane tensile strength and fatigue durability of the SiC/Si-N-C composite were investigated in this study. Test specimens with no holes, four different diameters of holes (1.0 to 3.2 mm), and four different open areas (20 to 35%) were machined. All mechanical testing was performed in air at a temperature of 910 C. Fatigue tests were conducted with a load ratio, R = 0.05, and a frequency of 0.33 Hz. In general, both the in-plane tensile strength of the composite and its fatigue durability decreased with an increase in the size of the hole and percentage of the open area. Reductions in the in-plane tensile strength and cyclic fatigue life of the composite were described by empirical equations with the diameter of the hole and the percent open area as the independent variables. The validity of these two empirical equations was verified with additional tensile and fatigue test data generated on the composite specimens.

Kalluri, Sreeramesh↗

Rapid Fabrication of Flat Plate Cavity Phosphor Thermography Test Models for Shuttle Return-to-Flight Aero-Heating

Methods, materials and equipment are documented for fabricating flat plate test models at NASA Langley Research Center for Shuttle return-to-flight aeroheating experiments simulating open and closed cavity interactions in Langley s hypersonic 20-Inch Mach 6 air wind tunnel. Approximately 96 silica ceramic flat plate cavity phosphor thermography test models have been fabricated using these methods. On one model, an additional slot is machined through the back of the plate and into the cavity and vented into an evacuated plenum chamber to simulate a further opening in the cavity. After sintering ceramic to 2150 F, and mounting support hardware, a ceramic-based two-color thermographic phosphor coating is applied for global temperature and heat transfer measurements, with fiducial markings for image registration.

Buck, Gregory M.↗

Sphere drag tests in the variable density wind tunnel

The air forces on a twenty-centimeter sphere were measured after it had been rebuilt as an open throat type. The results from tests made at widely different densities and airspeeds and also on a smaller sphere are given.

Jacobs, Eastman N↗

Air lock mechanism speeds specimen testing in high-temperature vacuum furnaces

Mechanism, made of 347 stainless steel, is attached to furnace port by bolted flange. Unit incorporates quick opening, high vacuum valve and associated fittings which provide connections to air lock evacuation and to inert gas supply for quenching specimen after it is withdrawn from furnace into air lock.

Whitehead, C.↗

Inlet Performance of the NFAC 1/50th-scale 80- by 120- Foot Wind Tunnel

The National Full-Scale Aerodynamics Complex 80- by 120-Foot Wind Tunnel (80x120) was dedicated in 1987 and rated at 100 knots for full-scale aircraft testing at NASA Ames Research Center. The 80x120 is the world’s largest wind tunnel, designed as an open circuit tunnel with a large aerodynamically treated inlet open to the ambient atmospheric air. In 2017, damage was sustained within the wind tunnel drive system, opening a window to do testing using the existing 1/50th-scale model of the 80- by 120-Foot Wind Tunnel within the full-scale 80- by 120-Foot Wind tunnel test section. The objective of the research was to quantify the turbulence levels within the 1/50th-scale test section as a function of onset atmospheric wind direction (± 90 deg from tunnel center-line), variable test section speed (5 – 50 m/s) and purposeful obtrusion of wind flow into the inlet. The model wind tunnel inlet, contraction, and test section are geometrically identical to that of the full-scale wind tunnel and model testing provides aerodynamic performance characteristics under controlled test conditions allowing for insight into the full-scale test section flow quality. The test section turbulence levels are minimally affected by the onset direction of the ambient atmospheric wind, but are dramatically affected by the speed in the tunnel while operated in the presence of winds. Original design specifications were axial/vertical/lateral turbulence ≤ 0.5% at maximum test section speed, though early full scale tunnel testing determined that lateral turbulence would be ≤ 0.6%. For test section speeds ≥ 30 m/s the tunnel is within the design specification limits. Between 5 m/s and 30 m/s, the test section turbulence levels are dependent on the onset wind direction and test section speed where test section turbulence in the axial, vertical and lateral directions was seen to be between 0.5% and 1% and, at times, greater than 1%. Finally, testing was performed with blockage designs at the inlet to disrupt the wind flow quality entering the tunnel contraction zone in an attempt to create higher levels of turbulence for high turbulent test conditions simulating the earth’s boundary layer. The highest turbulence levels measured were 6% in the axial direction by use of large spires designed to obstruct ≈ 50% of the inlet area.

Inlet Performance↗

Flow-establishment times for blunt bodies in an expansion tube

Flow establishment results are presented as obtained from shock standoff distance, pressure, and heat transfer measurements in the Langley expansion tube. The models tested were flat-faced cylinders with varying radius and a sphere with a constant radius, and they were positioned at the acceleration section exit and tested in the open jet at zero angle of attack. The experimental results were obtained as spinoff from various studies using helium, air, and CO2 test gases at freestream velocities in the range 5-7 km/sec. Time histories of shock detachment distance illustrate that the shock formation about the smaller-radii flat-faced cylinders and the sphere is symmetrical, whereas a complex, asymmetric formation is observed for the larger-radii cylinders. Flow is shown to establish more readily about the sphere than a flat-faced cylinder of the same diameter. A quasi-steady flow exists about relatively large blunt models during two-thirds of the approximate 250-microsec expansion tube test period.

Miller, C. G.↗

Two dimensional cold air cascade study of a film cooled turbine stator blade. 2: Experimental results of full film cooling tests

The effect of full film cooling on the performance of a turbine stator blade was studied in a two-dimensional cascade. The blade contained 12 rows of coolant holes, 6 rows on the suction surface and 6 on the pressure surface. Separate tests were first made with coolant ejection from each of the 12 rows. Then successive tests were made with various combinations of coolant rows open, including full film cooling. The principal results are presented in terms of primary-air efficiency as a function of coolant fraction. In addition, the efficiency results of the multirow tests are compared with the multi-row efficiency predicted by adding the single-row results.

Prust, H. W., Jr.↗

SIR Glass Test Vehicle Designed to Characterize Process Materials

The exposure to harsh environments can result in reliability issues on highly dense electronic packages and circuit assemblies. One area of concern is electrochemical failure mechanisms caused by electrolytic corrosion, electrochemical migration (dendrites), and leakage currents under humid conditions. These no-fault and no-trouble found failure points are challenging to detect and to perform process control during the assembly process. The focus of this research centers on metallizing glass surface insulation resistance test vehicles to characterize materials on electronic packages and components that exhibit the highest risk of failure due to material interactions and process residues. Glass test vehicles provide a visual representation of materials when they are exposed to moisture content in the air. Harsh environments can cause material interactions resulting in morphology changes, opening, and release of active components. A transparent test vehicle is highly functional for environmental stress testing under temperature, humidity, and bias. The designed experiment will evaluate the effects of material and process residues that can undergo changes in behavior during application, which leads to local failures.

Capen, Bill↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗