Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture

Evaluation Of Elbow Exoskeleton in Glovebox Operations To Minimize Injuries – 25704

In nuclear facilities across the DOE, ergonomic injuries pose a significant occupational hazard for GB workers. Recent studies at Los Alamos National Laboratory (LANL) have revealed concerning trends in worker health, with approximately 50% of GB workers reporting musculoskeletal symptoms after 25 years of service [1]. The current GB design, largely unchanged since the 1960s, presents several ergonomic challenges including inappropriate finger lengths, nonexistent joint angles, and incorrect thumb placement. These design flaws directly contribute to conditions such as lateral epicondylitis (tennis elbow) and De Quervain's tenosynovitis which causes pain and inflammation in the tendons at the base of the thumb. These are examples of conditions caused by workers performing repetitive precision tasks [2].

Ramon, Rodrigo N. [Savannah River National Laborat

Pressure Safety Training (Rev. 8)

This is the workbook for the Pressure Safety Training Course. It is intended as a reference manual and guide for all work with pressurized liquids or gases. This workbook contains basic references to make work with pressure safer. It is intended to supplement classroom instruction, rather than serve as a definitive text on pressure. Earlier versions of the manual were intended specifically for training at Lawrence Livermore National Laboratory. This revision is a generic version intended for training at all DOE facilities. The information in the Standards chapter is from the LLNL Health and Safety Manual. It is included here as a convenient reference and guide for developing similar standards at your own facility.

42 ENGINEERING

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Technical Background and Validation Report on the Residential Water Inhalation Risk Calculator Presented in the Risk Assessment Information System

Indoor air quality (IAQ) is critical for human health. Poor IAQ is linked to respiratory issues, cardiovascular diseases, and cancer. Indoor pollutants are emitted by typical household items such as cleaning products, personal care items, building materials, and tap water - an understudied volatile organic compound (VOC) source. This document presents the Residential Water Inhalation Risk Calculator (RWIRC), which estimates daily VOC exposure concentrations from various household water uses, such as showering and dishwashing, to assess exposure risks for the most vulnerable occupant. Integrated into the Risk Assessment Information System (RAIS) and sponsored by the US Department of Energy (DOE), the calculator divides a house into three compartments: shower, bathroom, and other spaces, accounting for daily water usage patterns and calculating VOC concentrations. Exposure data generated using the calculator can assist health assessors in estimating excess lifetime cancer risk (ELCR) and hazard index (HI) from VOC inhalation. Unlike traditional exposure models that utilize Andelman’s constant, the RWIRC continuously assesses variability in VOC concentrations and environmental conditions using differential equations to track VOC concentrations and air exchange between compartments. The calculator also provides unique volatilization fractions for each chemical and appliance, enhancing accuracy of the exposure concentration estimation. The RWIRC is accessible online and allows users to customize parameters (i.e., number of bathrooms, water temperature, and exhaust fan conditions) and input VOC characteristics (i.e., tap water and ambient air concentrations). This document provides a step-by-step guide on implementing the calculator. It also provides comparisons with the ATSDR-SHOWER calculator, using eight VOCs with varying physicochemical properties to reveal differences in algorithms and output concentrations. Simulations also assess how bathroom door positions and exhaust fan usage affect VOC exposure. The calculator results can enhance EPA risk screening levels for inhalation exposure to VOCs from tap water, offering a sophisticated tool for assessing inhalation risks and improving public health protection.

54 ENVIRONMENTAL SCIENCES

Assessing Indoor versus Outdoor PM 2.5 Concentrations during the 2025 Los Angeles Fires Using the PurpleAir Sensor Network

In January 2025, a series of fast-moving wildland-urban-interface (WUI) fires swept through the Los Angeles (LA) metropolitan area, causing severe air pollution. While the impacts of WUI fires on outdoor air quality have been extensively studied, indoor exposure remains less understood, despite most people sheltering indoors during WUI fires. Here, this study investigates the spatial and temporal patterns of indoor and outdoor PM 2.5 concentrations across the South Coast Air Basin, with a focus on LA County during the LA fires. Using high-resolution data from co-located indoor and outdoor PurpleAir (PA) sensors, we analyze hourly PM 2.5 levels and indoor/outdoor ratios. Outdoor PM 2.5 concentrations spiked sharply during the fires, reaching unhealthy levels exceeding 130 μg/m 3 , compared to the mean concentration (12 μg/m 3 ) during non-fire hours. Indoor concentrations also increased, though to a lesser extent, peaking around 60 μg/m 3 compared to a mean of 7 μg/m 3 during non-fire hours. This reflects the partial shielding that indoor environments provide from outdoor air pollution. The mean (0.42) and median (0.29) indoor/outdoor PM 2.5 ratios during LA fire hours were lower than the mean (0.93) and median (0.66) ratios during non-fire hours. Indoor/outdoor PM 2.5 ratios across sensors showed a wide distribution, reflecting differences in building characteristics and occupant behavior, such as indoor activities and the use of air purifiers. These findings emphasize the need for guidance and interventions to reduce indoor PM 2.5 exposure and protect public health during extreme WUI fire events.

2025 Los Angeles Fires

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES

BRCore: an R package implementing flexible selection of core taxa using contribution to Bray-Curtis dissimilarity and neutral model fitting

Identifying core taxa in microbial ecology highlights groups likely to participate in a broad range of potential ecological interactions. Here, we present BRCore, an R package to identify core taxa using abundance-occupancy distributions and beta-diversity contributions across ecological niches, and predict stochastic and deterministic taxa.

59 BASIC BIOLOGICAL SCIENCES

Estimating coccidioidomycosis endemicity while accounting for imperfect detection using spatio - temporal occupancy modeling

Coccidioidomycosis, or Valley fever, is an infectious disease caused by inhaling Coccidioides fungal spores. Incidence has risen in recent years, and it is believed the endemic region for Coccidioides is expanding in response to climate change. While Valley fever case data can help us understand trends in disease risk, using case data as a proxy for Coccidioides endemicity is not ideal because case data suffers from imperfect detection, including false positives (e.g., travel-related cases reported outside of endemic area) and false negatives (e.g., misdiagnosis or underreporting). Here we proposed a Bayesian, spatio-temporal occupancy model to relate monthly, county-level presence/absence data on Valley fever cases to latent endemicity of Coccidioides, accounting for imperfect detection. We used our model to estimate endemicity in the western United States. We estimated high probability of endemicity in southern California, Arizona, and New Mexico, but also in regions without mandated reporting, including western Texas, eastern Colorado, and southeastern Washington. We also quantified spatio-temporal variability in detectability of Valley fever, given an area is endemic to Coccidioides. We estimated an inverse relationship between lagged 3- and 9-month precipitation and case detection, and a positive association with agriculture. This work can help inform public health surveillance needs and identify areas that would benefit from mandatory case reporting.

60 APPLIED LIFE SCIENCES

Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households in the United States

Energy insecurity, or the inability to afford energy needs, affects most low-income households in the United States and leads to risky choices and additional insecurities including food and health. Although there are government programs designed to provide relief from energy insecurity, eligibility is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. Here we explore the relationship between energy insecurity and energy-limiting behaviors and investigate alternative solutions such as energy storage and rooftop solar. This analysis demonstrates that solar and energy storage can offset two-thirds of the bill savings that households could attain through severe energy-limiting behavior. These systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity.

Kerby, Jessica R. [Pacific Northwest National Labo

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska is the state's capital city and has a renewable energy goal to reach 80% renewable energy for the space heating and transportation sectors by 2045. In practical terms, this indicates a need to electrify both sectors, to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Energy Light & Power. In an effort to complement and enable electrification, researchers examined the feasibility to deploy storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows, while preserving operability and views. They can also improve comfort and reduce noise. Researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021, in addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues such as windows that were not square. These results point to several barriers to widespread deployment of storm windows in the area, but also open the door to opportunities to design deployment programs that improve safety as well as efficiency.

cold climate

Insulation Activation and Contamination in Low-Power Experiments

Among the diverse advanced nuclear reactor concepts being developed are designs that expect to operate at much higher temperatures than conventional light-water reactors, and therefore require alternative materials for components capable of withstanding these extreme temperatures. Insulation is one such component where alternative high-temperature industrial composites are being considered. Low-power experiments can provide an opportunity for advancing our understanding of material behavior under irradiation; however, these experiments are not without occupational hazards. The focus of this paper is the potential for activation of insulating composites when exposed to neutron fluence during reactor experiments, and to discuss the subsequent contamination of the testing area. This paper will also discuss practical measures for preventing the creation and inhalation of activated particulate matter (i.e., dust), such as engineering and administrative controls and personal protective equipment. This paper evaluates the suitability of several insulation materials for use in reactor experiments based on their activation from neutron irradiation. The materials considered are Pyrogel XTE by Aspen Aerogel, Cerablanket and Kaowool by Morgan Advanced Materials, Thermo-12 Gold by Johns Manville, and Maxsil CF6-2000 by McAllister Mills. Although these materials are not yet widely used in the nuclear industry, they are common in other industries due to their thermal insulating properties. These materials produce dust while handling that can pose health and safety hazards, which could be further exacerbated by activation. The analysis presented in this paper utilizes a deterministic method developed to predict the activation source term of the provided insulation materials. The method calculates the atomic density of each element within the composites and simulates their exposure to a specified neutron flux density representative of low power experimental conditions. During the irradiation phase and throughout the extensive cooling period, neutron absorptions and nuclear decays are tracked for relevant isotopes. The residual activity within each composite is then assessed to identify the material with the lowest potential radiological hazard to workers. Dust will be created during installation and removal of insulating materials and may also be generated during the experiment. Contamination of surrounding surfaces due to dispersion is highly likely unless preventative measures are taken. The results of this analysis are used to estimate an internal dose from inhalation of activated dust, which is significantly lower than the allowable whole-body dose. However, the risk of internal exposure may increase if the dust becomes a transport vector for nuclear material. The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of these insulating materials in low-power nuclear experiments and to foster safer work environments through informed decision-making and strategic planning. This work ultimately contributes to a broader understanding of how new non-nuclear materials for advanced reactors impact the radiological safety of co-located workers, helping to ensure the responsible management of radioactive materials during installation and decommissioning activities.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE

Dataset for: Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households

Energy insecurity affects most low-income households in the United States. Energy insecurity, which is characterized by a household’s inability to afford their energy needs, often leads to risky choices, causing other forms of insecurity including food and health. Although there are government programs designed to provide relief to low-income households that face energy insecurity, eligibility for these programs is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. This paper explores the relationship between energy insecurity and energy-limiting behaviors to investigate alternative solutions that target the households that may fall out of available energy assistance programs. We explore the role of battery energy storage systems and rooftop solar photovoltaics in improving energy affordability. The results show that residential rooftop solar and behind-the-meter energy storage can offset two-thirds of the bill savings that households attain through energy-limiting behavior. Household renewable energy systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit.

Kerby, Jessica [Pacific Northwest National Laborat

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska, is the state's capital city and aims to reach 80% renewable energy for the space heating and transportation sectors by 2045. This goal highlights a need to electrify both sectors to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Electric Light and Power. To that end, researchers examined the feasibility of deploying storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows while preserving operability and views. They can also improve comfort and reduce noise. In addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews, researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues, such as windows that were not square. These results point to several barriers to the widespread deployment of window upgrades in the area and open the door to opportunities to design deployment programs that improve safety and efficiency.

cold climate

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization

Acute Exposure to Aerosolized Nanoplastics Modulates Redox-Linked Immune Responses in Human Airway Epithelium

Micro- and nanoplastics (MPs and NPs) are pervasive environmental pollutants detected in aquatic ecosystems, with emerging evidence suggesting their presence in airborne particles generated by water body motion. Inhalation exposure to airborne MPs and NPs remains understudied despite documented links between occupational exposure to these particles and adverse respiratory outcomes, including airway inflammation, oxidative stress, and chronic respiratory diseases. This study explored the effects of acute NP exposure on a fully differentiated 3D human airway epithelial model derived from 14 healthy donors. Airway epithelium was exposed to aerosolized 50 nm polystyrene NPs at concentrations ranging from 2.5 to 2500 µg/mL for three minutes per day over three days. Functional assays revealed no significant alterations in tissue integrity, cell survival, mucociliary clearance, or cilia beat frequency, suggesting intact epithelial function post-exposure. However, cytokine and chemokine profiling identified a significant five-fold increase in CCL3 (MIP-1α), a neutrophilic chemoattractant, in NP-exposed samples compared to controls. This was corroborated by increased neutrophil chemotaxis in response to conditioned media from NP-exposed tissues, indicating a pro-inflammatory neutrophilic response. Conversely, levels of interleukins (IL-21, IL-2, IL-15), CXCL10, and TGF-β were significantly reduced, suggesting immunomodulatory effects that may impair adaptive immune responses and tissue repair mechanisms. These findings demonstrate that short-term exposure to NP-containing aerosols induces a distinct pro-inflammatory response in airway epithelium, characterized by enhanced neutrophil recruitment and reduced secretion of key immune modulators. These findings underscore the potential for aerosolized NPs to induce oxidative and inflammatory stress, raising concerns about their long-term impact on respiratory health and redox regulation.

Biochemistry & Molecular Biology