Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Prediction and assignment of site occupation and energy levels for Pb{sup 2+} ions in crystal hosts

The environmental factor h{sub e} of the host was calculated quantitatively in Pb{sup 2+}-doped 23 compounds based on the dielectric theory of chemical bond for complex crystals. The relationship between the A band energy E{sub A} of Pb{sup 2+} and the environmental factor h{sub e} was intensively studied. The results indicate that E{sub A} of Pb{sup 2+} decreases linearly with increasing of h{sub e}. A linear model was proposed which allows us to correctly predict and assign the site occupations and the position of A band for Pb{sup 2+}-doped compounds if the crystal structure and the refraction index were known. Applied to SrGa{sub 2}O{sub 4}:Pb{sup 2+}, CaAl{sub 2}B{sub 2}O{sub 7}:Pb{sup 2+} and SrAl{sub 2}B{sub 2}O{sub 7}:Pb{sup 2+}, the theoretical predictions are in very good agreement with the experimental data. In SrGa{sub 2}O{sub 4}:Pb{sup 2+}, the excitation spectrum of Pb{sup 2+} from two different cation sites was identified: the higher energy band of A (265 nm) from the site of Sr2, and the lower ones (280 nm) from the site of Sr1. - Graphical abstract: The A band energy E{sub A} of Pb{sup 2+} has linear relationship with environmental factor h{sub e}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Occupancy schedules learning process through a data mining framework

Building occupancy is a paramount factor in building energy simulations. Specifically, lighting, plug loads, HVAC equipment utilization, fresh air requirements and internal heat gain or loss greatly depends on the level of occupancy within a building. Developing the appropriate methodologies to describe and reproduce the intricate network responsible for human-building interactions are needed. Extrapolation of patterns from big data streams is a powerful analysis technique which will allow for a better understanding of energy usage in buildings. A three-step data mining framework is applied to discover occupancy patterns in office spaces. First, a data set of 16 offices with 10 minute interval occupancy data, over a two year period is mined through a decision tree model which predicts the occupancy presence. Then a rule induction algorithm is used to learn a pruned set of rules on the results from the decision tree model. Finally, a cluster analysis is employed in order to obtain consistent patterns of occupancy schedules. Furthermore, the identified occupancy rules and schedules are representative as four archetypal working profiles that can be used as input to current building energy modeling programs, such as EnergyPlus or IDA-ICE, to investigate impact of occupant presence on design, operation and energy use in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantitative Analysis of the Drosophila Segmentation Regulatory Network Using Pattern Generating Potentials

Cis-regulatory modules that drive precise spatial-temporal patterns of gene expression are central to the process of metazoan development. We describe a new computational strategy to annotate genomic sequences based on their ‘‘pattern generating potential’’ and to produce quantitative descriptions of transcriptional regulatory networks at the level of individual protein-module interactions. We use this approach to convert the qualitative understanding of interactions that regulate Drosophila segmentation into a network model in which a confidence value is associated with each transcription factor-module interaction. Sequence information from multiple Drosophila species is integrated with transcription factor binding specificities to determine conserved binding site frequencies across the genome. These binding site profiles are combined with transcription factor expression information to create a model to predict module activity patterns. This model is used to scan genomic sequences for the potential to generate all or part of the expression pattern of a nearby gene, obtained from available gene expression databases. Interactions between individual transcription factors and modules are inferred by a statistical method to quantify a factor’s contribution to the module’s pattern generating potential. We use these pattern generating potentials to systematically describe the location and function of known and novel cis-regulatory modules in the segmentation network, identifying many examples of modules predicted to have overlapping expression activities. Surprisingly, conserved transcription factor binding site frequencies were as effective as experimental measurements of occupancy in predicting module expression patterns or factor-module interactions. Thus, unlike previous module prediction methods, this method predicts not only the location of modules but also their spatial activity pattern and the factors that directly determine this pattern. As databases of transcription factor specificities and in vivo gene expression patterns grow, analysis of pattern generating potentials provides a general method to decode transcriptional regulatory sequences and networks.

59 BASIC BIOLOGICAL SCIENCES↗

An Occupational Performance Test Validation Program for Fire Fighters at the Kennedy Space Center

We evaluated performance of a modified Combat Task Test (CTT) and of standard fitness tests in 20 male subjects to assess the prediction of occupational performance standards for Kennedy Space Center fire fighters. The CTT consisted of stair-climbing, a chopping simulation, and a victim rescue simulation. Average CTT performance time was 3.61 +/- 0.25 min (SEM) and all CTT tasks required 93% to 97% maximal heart rate. By using scores from the standard fitness tests, a multiple linear regression model was fitted to each parameter: the stairclimb (r(exp 2) = .905, P less than .05), the chopping performance time (r(exp 2) = .582, P less than .05), the victim rescue time (r(exp 2) = .218, P = not significant), and the total performance time (r(exp 2) = .769, P less than .05). Treadmill time was the predominant variable, being the major predictor in two of four models. These results indicated that standardized fitness tests can predict performance on some CTT tasks and that test predictors were amenable to exercise training.

Schonfeld, Brian R.↗

Quantifying spatiotemporal variability in occupant exposure to an indoor airborne contaminant with an uncertain source location

Well-mixed zone models are often employed to compute indoor air quality and occupant exposures. While effective, a potential downside to assuming instantaneous, perfect mixing is underpredicting exposures to high intermittent concentrations within a room. When such cases are of concern, more spatially resolved models, like computational-fluid dynamics methods, are used for some or all of the zones. But, these models have higher computational costs and require more input information. A preferred compromise would be to continue with a multi-zone modeling approach for all rooms, but with a better assessment of the spatial variability within a room. Here to do so, we present a quantitative method for estimating a room's spatiotemporal variability, based on influential room parameters. Our proposed method disaggregates variability into the variability in a room's average concentration, and the spatial variability within the room relative to that average. This enables a detailed assessment of how variability in particular room parameters impacts the uncertain occupant exposures. To demonstrate the utility of this method, we simulate contaminant dispersion for a variety of possible source locations. We compute breathing-zone exposure during the releasing (source is active) and decaying (source is removed) periods. Using CFD methods, we found after a 30 minutes release the average standard deviation in the spatial distribution of exposure was approximately 28% of the source average exposure, whereas variability in the different average exposures was lower, only 10% of the total average. We also find that although uncertainty in the source location leads to variability in the average magnitude of transient exposure, it does not have a particularly large influence on the spatial distribution during the decaying period, or on the average contaminant removal rate. By systematically characterizing a room's average concentration, its variability, and the spatial variability within the room important insights can be gained as to how much uncertainty is introduced into occupant exposure predictions by assuming a uniform in-room contaminant concentration. We discuss how the results of these characterizations can improve our understanding of the uncertainty in occupant exposures relative to well-mixed models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Demand Flexibility: Modeling Occupant Behavior using Sociodemographic Predictors

Demand flexibility (DF) has the potential to increase the saturation of renewables in the grid and reduce operating costs for both utilities and customers. However, less than 8% of U.S. residential electric customers are enrolled in DF programs. A major research gap on this topic is an uneven understanding of behavioral drivers of electricity use and DF program participation at the household level. In this study, we employ machine learning models to predict residential occupant behavior in activities relevant to DF. We model occupants' extensive decisions (i.e., choice of action) and intensive behaviors (i.e., amount of time spent) during peak and off-peak time periods using the publicly available American Time Use Survey, which includes activities data for approximately 200,000 respondents. In our machine learning models, predictions for both extensive and intensive behavior fell within a +/-20% error margin at the aggregate level. We identify 13 key sociodemographic predictors of DF-related intensive behavior using LASSO inference and beta coefficient ranking. However, these top predictors differ by activity, suggesting potential scope for differential user targeting for DF events and technologies during program design. This work also contributes to understanding when and who might adopt these DF technologies based on their daily routine activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing the cardiovascular therapeutic indices of glycopyrronium and tiotropium in an integrated rat pharmacokinetic, pharmacodynamic and safety model

Long acting inhaled muscarinic receptor antagonists, such as tiotropium, are widely used as bronchodilator therapy for chronic obstructive pulmonary disease (COPD). Although this class of compounds is generally considered to be safe and well tolerated in COPD patients the cardiovascular safety of tiotropium has recently been questioned. We describe a rat in vivo model that allows the concurrent assessment of muscarinic antagonist potency, bronchodilator efficacy and a potential for side effects, and we use this model to compare tiotropium with NVA237 (glycopyrronium bromide), a recently approved inhaled muscarinic antagonist for COPD. Anaesthetized Brown Norway rats were dosed intratracheally at 1 or 6 h prior to receiving increasing doses of intravenous methacholine. Changes in airway resistance and cardiovascular function were recorded and therapeutic indices were calculated against the ED{sub 50} values for the inhibition of methacholine-induced bronchoconstriction. At both time points studied, greater therapeutic indices for hypotension and bradycardia were observed with glycopyrronium (19.5 and 28.5 fold at 1 h; > 200 fold at 6 h) than with tiotropium (1.5 and 4.2 fold at 1 h; 4.6 and 5.5 fold at 6 h). Pharmacokinetic, protein plasma binding and rat muscarinic receptor binding properties for both compounds were determined and used to generate an integrated model of systemic M{sub 2} muscarinic receptor occupancy, which predicted significantly higher M{sub 2} receptor blockade at ED{sub 50} doses with tiotropium than with glycopyrronium. In our preclinical model there was an improved safety profile for glycopyrronium when compared with tiotropium. - Highlights: • We use an in vivo rat model to study CV safety of inhaled muscarinic antagonists. • We integrate protein and receptor binding and PK of tiotropium and glycopyrrolate. • At ED{sub 50} doses for bronchoprotection we model systemic M{sub 2} receptor occupancy. • Glycopyrrolate demonstrates lower M{sub 2} occupancy at bronchoprotective doses. • Glycopyrrolate demonstrates an improved CV safety profile, versus tiotropium.

60 APPLIED LIFE SCIENCES↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transfer learning for smart buildings: A critical review of algorithms, applications, and future perspectives

Smart buildings play a crucial role toward decarbonizing society, as globally buildings emit about one-third of greenhouse gases. In the last few years, machine learning has achieved a notable momentum that, if properly harnessed, may unleash its potential for advanced analytics and control of smart buildings, enabling the technique to scale up for supporting the decarbonization of the building sector. In this perspective, transfer learning aims to improve the performance of a target learner exploiting knowledge in related environments. The present work provides a comprehensive overview of transfer learning applications in smart buildings, classifying and analyzing 77 papers according to their applications, algorithms, and adopted metrics. The study identified four main application areas of transfer learning: (1) building load prediction, (2) occupancy detection and activity recognition, (3) building dynamics modeling, and (4) energy systems control. Furthermore, the review highlighted the role of deep learning in transfer learning applications that has been used in more than half of the analyzed studies. The paper also discusses how to integrate transfer learning in a smart building's ecosystem, identifying, for each application area, the research gaps and guidelines for future research directions.

Pinto, G↗

Cross-correlation of SDSS DR7 quasars and DR10 BOSS galaxies: The weak luminosity dependence of quasar clustering at z ∼ 0.5

We present the measurement of the two-point cross-correlation function (CCF) of 8198 Sloan Digital Sky Survey Data Release 7 quasars and 349,608 Data Release 10 CMASS galaxies from the Baryonic Oscillation Spectroscopic Survey at 0.3 < z < 0.9. The CCF can be reasonably well fit by a power-law model ξ{sub QG}(r) = (r/r {sub 0}){sup –γ} on projected scales of r{sub p} = 2-25 h {sup –1} Mpc with r {sub 0} = 6.61 ± 0.25 h {sup –1} Mpc and γ = 1.69 ± 0.07. We estimate a quasar linear bias of b{sub Q} = 1.38 ± 0.10 at (z) = 0.53 from the CCF measurements, which corresponds to a characteristic host halo mass of ∼4 × 10{sup 12} h {sup –1} M {sub ☉}, compared with a ∼10{sup 13} h {sup –1} M {sub ☉} characteristic host halo mass for CMASS galaxies. Based on the clustering measurements, most quasars at z-bar ∼0.5 are not the descendants of their higher luminosity counterparts at higher redshift, which would have evolved into more massive and more biased systems at low redshift. We divide the quasar sample in luminosity and constrain the luminosity dependence of quasar bias to be db{sub Q} /dlog L = 0.20 ± 0.34 or 0.11 ± 0.32 (depending on different luminosity divisions) for quasar luminosities –23.5 > M{sub i} (z = 2) > –25.5, implying a weak luminosity dependence of clustering for luminous quasars at z-bar ∼0.5. We compare our measurements with theoretical predictions, halo occupation distribution (HOD) models, and mock catalogs. These comparisons suggest that quasars reside in a broad range of host halos. The host halo mass distributions significantly overlap with each other for quasars at different luminosities, implying a poor correlation between halo mass and instantaneous quasar luminosity. We also find that the quasar HOD parameterization is largely degenerate such that different HODs can reproduce the CCF equally well, but with different satellite fractions and host halo mass distributions. These results highlight the limitations and ambiguities in modeling the distribution of quasars with the standard HOD approach.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic-layer doping of SiGe heterostructures for atomic-precision donor devices

As a first step to porting scanning tunneling microscopy methods of atomic-precision fabrication to a strained-Si/SiGe platform, we demonstrate post-growth P atomic-layer doping of SiGe heterostructures. To preserve the substrate structure and elastic state, we use a T ≤ 800 °C process to prepare clean Si 0.86 Ge 0.14 surfaces suitable for atomic-precision fabrication. P-saturated atomic-layer doping is incorporated and capped with epitaxial Si under a thermal budget compatible with atomic-precision fabrication. Hall measurements at T = 0.3 K show that the doped heterostructure has R $\square$ = 570 ± 30 Ω , yielding an electron density n e = 2.1 ± 0.1 × 10 14 cm -2 and mobility μ e = 52 ± 3 cm 2 V -1 s -1 , similar to saturated atomic-layer doping in pure Si and Ge. The magnitude of μ e and the complete absence of Shubnikov–de Haas oscillations in magnetotransport measurements indicate that electrons are overwhelmingly localized in the donor layer, and not within a nearby buried Si well. Finally, this conclusion is supported by self-consistent Schrödinger-Poisson calculations that predict electron occupation primarily in the donor layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance Evaluation of an Occupancy-Based HVAC Control System in an Office Building

As new algorithms incorporate occupancy count information into more sophisticated HVAC control, these technologies offer great potential for reductions in energy costs while enhancing flexibility. This study presents results from a two-year field evaluation of an occupancy-based HVAC control system installed in an office building. Two wings on each of the building’s 2–11 floors were equipped with occupancy counters to learn occupancy patterns. In combination with proprietary machine learning algorithms and thermal modeling, the occupancy data were leveraged to implement optimized start, early closure, and adjustments to fan operation at the air handling unit (AHU) level. This study conducted a holistic evaluation of technical performance, cost-effectiveness analysis, and user satisfaction. Results show the platform reduced weekday AHU run times by 2 h and 35 min per AHU per day during the pandemic time period. Simulation shows that 6.1% annual whole-building savings can be achieved when the building is fully occupied. The results are compared with prior studies, and potential drivers are discussed for future opportunities. The assessment results shed light on the expected in-the-field performance for researchers and industry stakeholders and enabled practical considerations as the technology strives to move beyond research-grade pilot trials into product-grade deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of crash test pulses and their application to aircraft seat analysis

Deceleration time histories (crash pulses) from a series of twelve light aircraft crash tests conducted at NASA Langley Research Center (LaRC) were analyzed to provide data for seat and airframe design for crashworthiness. Two vertical drop tests at 12.8 m/s (42 ft/s) and 36 G peak deceleration (simulating one of the vertical light aircraft crash pulses) were made using an energy absorbing light aircraft seat prototype. Vertical pelvis acceleration measured in a 50 percentile dummy in the energy absorbing seat were found to be 45% lower than those obtained from the same dummy in a typical light aircraft seat. A hybrid mathematical seat-occupant model was developed using the DYCAST nonlinear finite element computer code and was used to analyze a vertical drop test of the energy absorbing seat. Seat and occupant accelerations predicted by the DYCAST model compared quite favorably with experimental values.

Alfaro-Bou, E.↗

Using Clustering to Establish Climate Regimes from PCM Output

A multivariate statistical clustering technique--based on the k-means algorithm of Hartigan has been used to extract patterns of climatological significance from 200 years of general circulation model (GCM) output. Originally developed and implemented on a Beowulf-style parallel computer constructed by Hoffman and Hargrove from surplus commodity desktop PCs, the high performance parallel clustering algorithm was previously applied to the derivation of ecoregions from map stacks of 9 and 25 geophysical conditions or variables for the conterminous U.S. at a resolution of 1 sq km. Now applied both across space and through time, the clustering technique yields temporally-varying climate regimes predicted by transient runs of the Parallel Climate Model (PCM). Using a business-as-usual (BAU) scenario and clustering four fields of significance to the global water cycle (surface temperature, precipitation, soil moisture, and snow depth) from 1871 through 2098, the authors' analysis shows an increase in spatial area occupied by the cluster or climate regime which typifies desert regions (i.e., an increase in desertification) and a decrease in the spatial area occupied by the climate regime typifying winter-time high latitude perma-frost regions. The patterns of cluster changes have been analyzed to understand the predicted variability in the water cycle on global and continental scales. In addition, representative climate regimes were determined by taking three 10-year averages of the fields 100 years apart for northern hemisphere winter (December, January, and February) and summer (June, July, and August). The result is global maps of typical seasonal climate regimes for 100 years in the past, for the present, and for 100 years into the future. Using three-dimensional data or phase space representations of these climate regimes (i.e., the cluster centroids), the authors demonstrate the portion of this phase space occupied by the land surface at all points in space and time. Any single spot on the globe will exist in one of these climate regimes at any single point in time. By incrementing time, that same spot will trace out a trajectory or orbit between and among these climate regimes (or atmospheric states) in phase (or state) space. When a geographic region enters a state it never previously visited, a climatic change is said to have occurred. Tracing out the entire trajectory of a single spot on the globe yields a 'manifold' in state space representing the shape of its predicted climate occupancy. This sort of analysis enables a researcher to more easily grasp the multivariate behavior of the climate system.

Oglesby, Robert↗

Southern California Water Resources: Using NASA Earth Observations to Monitor Seagrass Extent and Water Quality Parameters in Southern California

Eelgrass (Zostera marina) is a species of submerged aquatic vegetation found in shallow bays and estuaries with soft seafloors. Eelgrass is recognized for providing ecosystem benefits, such as carbon sequestration, sediment stabilization, water clarification, and fish and wildlife habitats. However, eelgrass is impacted by both marine and terrestrial threats associated with climate change. In this project, we worked with the Southern California Coastal Water Research Project, the National Oceanic and Atmospheric Administration’s National Marine Fisheries Service, and the State of California San Diego Regional Water Quality Control Board to investigate water quality parameters (i.e., chlorophyll-a concentration, sea surface temperature, and turbidity) associated with eelgrass in Newport Bay and Mission Bay, California. The team used Landsat 8 Operational Land Imager and Thermal Infrared Sensor, Landsat 9 Operational Land Imager-2 and Thermal Infrared Sensor-2, Sentinel-2 MultiSpectral Instrument, and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station land surface temperature and cloud mask to create a time series of these water quality parameters from 2019–2023. We found that the parameters followed cyclical, seasonal patterns with turbidity and sea surface temperature peaking in the summer. We did not find that the parameters had changed significantly over longer time periods. These results will be used in a model developed by the Southern California Coastal Water Research Project to assess eelgrass ecosystem health and predict ecosystem occupancy in the future.

Katya Beener↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗