Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integrated Framework of Multisource Data Fusion for Outage Location in Looped Distribution Systems

Accurate outage location is essential for expediting post-outage power restoration, minimizing outage duration, and enhancing the resilience of distribution networks. With the advent of advanced metering infrastructure, data-driven outage location methods have significantly advanced beyond traditional approaches that rely on manual inspections. However, existing methods still face critical challenges, like reliance on single-source data, limited ability to handle partially observable systems or difficulties with loop networks. To the best of our knowledge, no single approach has comprehensively addressed all of these challenges at once. To this end, this paper proposes a comprehensive multisource data fusion framework for outage locations via probabilistic graph networks. The framework consists of three key phases. First, a novel method for reconstituting distribution networks with loops is developed, transforming looped networks into multiple radial subnetworks that retain all outage causalities of the original network. Second, Bayesian network (BN) models are established for each subnetwork, integrating multiple data sources and network structures. Finally, a joint Gibbs sampling mechanism, featuring forward and backward information flow, is designed to merge data from separate BN models and maximize the utilization of limited evidence, ensuring accurate outage location identification. In conclusion, the framework was validated on two modified public test systems, and comparative studies confirmed its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lagrange-Based Options for Relay Satellites to Eliminate Earth-Mars Communications Outages During Solar Superior Conjunctions

Recent conjunction class Mars human mission plans have generally assumed that there will inevitably be periods of communications outages between Earth and Mars. This has significant cost and risk implications for not only Mars missions, but also precursor missions in the lunar environment. But are there ways to avoid these outages? The potential exists for communications to be interrupted by Solar Superior Conjunctions (SSCs). Depending on the communications system, used, there can be communications outages up to as many as 78 days. The higher bandwidth systems experience the greatest outage. If these communications channels are interrupted due to an SSC, there are of course resulting challenges to mission operations. An outage of a few days to a few weeks could allow minor disturbances to become major concerns or even trigger subsystems failures. An inability to consult with the ground at the wrong time could result in loss of mission, loss of an element, or loss of life. Each planet in the solar system has a set of five Lagrange points associated with it and the Sun. At any given point in time, a planet or either its L4 or L5 point is visible to any other planet in the solar system, regardless of the position of the sun relative to the two. Thus, L4 and L5 have high value as relay systems to prevent communications outages. There are four sets of solar Lagrange points that may be of potential use in this study: Mars-Sun L4 and L5 points, Earth-Sun L4 and L5, Venus-Sun L4 and L5, and Mercury-Sun L4 and L5. A candidate relay satellite system will be identified, with consideration of both new technology developments and existing telecommunications satellites. This system may have implications for not only the Mars human mission architectures, but also Gateway and human lunar surface architectures as these other studies are tasked with paving the way to human Mars missions. If Mars communications outages can be eliminated, then the degree of autonomy necessary in Mars and precursor systems may be reduced.

Relay Satellite↗

Technology Integration Initiative In Support of Outage Management

Plant outage management is a high priority concern for the nuclear industry from cost and safety perspectives. Often, command and control during outages is maintained in the outage control center where many of the underlying technologies supporting outage control are the same as those used in the 1980’s. This research reports on the use of advanced integrating software technologies and hand held mobile devices as a means by which to reduce cycle time, improve accuracy, and enhance transparency among outage team members. This paper reports on the first phase of research supported by the DOE Light Water Reactor Sustainability (LWRS) Program that is performed in close collaboration with industry to examine the introduction of newly available technology allowing for safe and efficient outage performance. It is thought that this research will result in: improved resource management among various plant stakeholder groups, reduced paper work, and enhanced overall situation awareness for the outage control center management team. A description of field data collection methods, including personnel interview data, success factors, end-user evaluation and integration of hand held devices in achieving an integrated design are also evaluated. Finally, the necessity of obtaining operations cooperation support in field studies and technology evaluation is acknowledged.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Olkiluoto 1 and 2 - Plant efficiency improvement and lifetime extension-project (PELE) implemented during outages 2010 and 2011

Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to the program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Concepts for an Outage Control Center Information Dashboard

The nuclear industry, and the business world in general, is facing a rapidly increasing amount of data to be dealt with on a daily basis. In the last two decades, the steady improvement of data storage devices and means to create and collect data along the way influenced the manner in which we deal with information. Most data is still stored without filtering and refinement for later use. Many functions at a nuclear power plant generate vast amounts of data, with scheduled and unscheduled outages being a prime example of a source of some of the most complex data sets at the plant. To make matters worse, modern information and communications technology is making it possible to collect and store data faster than our ability to use it for making decisions. However, in most applications, especially outages, raw data has no value in itself; instead, managers, engineers and other specialists want to extract the information contained in it. The complexity and sheer volume of data could lead to information overload, resulting in getting lost in data that may be irrelevant to the task at hand, processed in an inappropriate way, or presented in an ineffective way. To prevent information overload, many data sources are ignored so production opportunities are lost because utilities lack the ability to deal with the enormous data volumes properly. Decision-makers are often confronted with large amounts of disparate, conflicting and dynamic information, which are available from multiple heterogeneous sources. Information and communication technologies alone will not solve this problem. Utilities need effective methods to exploit and use the hidden opportunities and knowledge residing in unexplored data resources. Superior performance before, during and after outages depends upon the right information being available at the right time to the right people. Acquisition of raw data is the easy part; instead, it is the ability to use advanced analytical, data processing and data visualization methods to turn the data into reliable information and comprehensible, actionable information. Techniques like data mining, filtering and analysis only work reliably for well-defined and well-understood problems. The path from data to decision is more complex. The ability to communicate knowledge during outages and emergent issues is crucial. This paper presents an approach to turn the unused data into an opportunity: applying principles from semiotics, human factors and visual analytics to transform the traditional way of processing outage data into media that will improve the collective situation awareness, knowledge, decisions, actions and overall performance of the entire outage team, and also support the reliability, quality and overall effectiveness of maintenance work. The application of the proposed visualization methods will become the medium of a semi-automated analytical process where humans and machines cooperate using their respective, distinct capabilities for the most effective results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Estimating Critical Customer Outages Resulting from Extreme Hurricanes

US power outage data has been collected by organizations such as Oak Ridge National Laboratory (ORNL) through Environment for Analysis Geo-Located Energy Infrastructure (EAGLE-I: freely available) and poweroutage.us (commercial data: available to purchase). However, these sources do not provide information specific to outages of critical customers. Critical customers include entities, facilities, and individuals whose continuous access to electricity is essential for public safety, emergency response, disaster recovery, the well-being of vulnerable populations, public safety and order, and public utilities such as natural gas, communications, water and sanitation. Identification and geolocation of critical customers is crucial for understanding and addressing the effects of power outages on essential services and ensuring that necessary measures are taken to maintain their operations during power disruptions. This work is a first step towards estimating the occurrences of critical customer outages and developing a critical customer power outage data repository. This work estimates outage incidents of critical customers through spatiotemporal mapping of power outage data, weather data, building data, and critical infrastructure network data. Our results show that critical customer effects vary across different counties. We provide appropriate mathematical explanations and simplifications to define and systematize the proposed approach.

Bhusal, Narayan [ORNL] (ORCID:0000000222752145)↗

A Bayesian Approach Based Outage Prediction in Electric Utility Systems Using Radar Measurement Data

Severe weather events such as strong thunderstorms are some of the most significant and frequent threats to the electrical grid infrastructure. Outages resulting from storms can be very costly. While some tools are available to utilities to predict storm occurrences and damage, they are typically very crude and provide little means of facilitating restoration efforts. This study developed a methodology to use historical high-resolution (both temporal and spatial) radar observations of storm characteristics and outage information to develop weather condition dependent failure rate models (FRMs) for different grid components. Such models can provide an estimation or prediction of the outage numbers in small areas of a utility’s service territory once the real-time measurement or forecasted data of weather conditions become available as the input to the models. Considering the potential value provided by real-time outages reported, a Bayesian outage prediction (BOP) algorithm is proposed to account for both strength and uncertainties of the reported outages and failure rate models. The potential benefit of this outage prediction scheme is illustrated in this study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OTRA-THS MAC to reduce Power Outage Data Collection Latency in a smart meter network

The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion. Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.

Garlapati, Shravan K↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

Analysis and Mitigation of Cascading Outages Using an Interaction Graph Addressing Transient Stability

Cascading outages of power systems pose great threats to system security and reliability, potentially leading to large-scale blackouts. For analysis and mitigation of cascading outages, this paper proposes a transient stability-incorporated interaction graph. This graph statistically quantifies the interactions among line outages and instabilities of generators, which can model propagation paths and patterns of cascading outages. Compared with an interaction graph that only models line outages, this new interaction graph provides important insights on how transient instability occurs along with cascading outages. It also offers more effective strategies for mitigating outage propagation. The proposed interaction graph can be constructed from datasets of historical or simulated cascading events. It is demonstrated on an NPCC 140-bus system with mitigation strategies.

Guo, Zhenping↗

A flexible framework for modeling customer damage functions for power outages

This paper develops a flexible method for estimating the customer cost of a power outage. We add to the current body of literature by outlining a framework which properly accounts for the effects of outage duration. We begin by separating costs into categories depending on whether the cost varies with outage duration and whether the cost is due to perishable inventory. We derive useful functional forms for each cost category and discuss how parameters vary by load type and outage characteristics. We derive outage cost estimates for an unexpected loss of power to both an example manufacturing plant and an example fire station. The framework described in this paper can easily be employed to model outage costs for a wide range of specific operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Evaluating the Impact of Power Outages on Occupancy Patterns During the 2021 Texas Power Crisis

Large-scale power outages, such as those caused by extreme weather events, have a big impact on human behavior. A short power outage is merely a nuisance for most, and may not change people's locations. An outage that lasts for a few hours can result in spoiled food and medical supplies, and people will have to restock spoiled items. Long outages result in temperatures outside tolerable levels in homes, and may prompt people to acquire supplies, such as generators and gas, or change location. The long outages during Winter Storm Uri in Texas resulted in millions of dollars in property damage due to freezing pipes. This level of damage is expected to result in a sharp increase in supply runs and contractor activity. In this paper, we present a tool to explore differences in visiting patterns before, during, and after power outages. It allows to compare different points of interest like medical facilities, grocery stores, hardware stores, and other types of businesses.

big data↗

A Business Case for Advanced Outage Management

The Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program develops and validates technologies that will make the U.S. operating nuclear fleet more efficient and competitive. The program has developed a standard methodology for determining the impact of new technologies in order to assist nuclear power plant (NPP) operators in building sound business cases. This paper presents a generic business case for implementation of technology that supports Advanced Outage Management (AOM). The analysis presented demonstrates that advanced communication and networking and analytical technologies will allow NPP to conduct outages with fewer people in management roles and the remaining people can be more effective and more productive. The benefits are quantified with a rough order of magnitude that provides directional guidance to NPPs that are interested in developing a similar business case. Advanced Outage Management is enabled by a suite of technologies, which are described in further detail in the body of this report. They include: • Mobile Work Packages (MWP) • Computer Based Procedures (CBP) • Personal Digital Assistants (PDA) also referred to as smart devices • Barcode readers • High bandwidth wireless networks • Collaboration software (i.e., OneNote) • Advanced digital displays • Advanced data analytics All the hardware necessary to implement AOM as envisioned in this report is readily available today. Configuration to perform within the plant systems and regulatory boundaries would need to be developed by the NPP. 1. The resulting business case demonstrates benefits in two major categories: 2. Reduction in resources required to manage the outage, a. Increased productivity in outage work that reduces the likelihood of schedule overruns: b. reduce likelihood of bulk work resulting in outage delays c. improved management of critical path single issues, d. improved management of emergent work (improve time to collect data and prepare response) It is important to note that in order to realize these benefits at the scale described in this report requires the plant to rethink how technologies can disrupt current processes; how data might be captured, processed, analyzed and presented with little or no human intervention. In many cases, technology be fully utilized in a way that not only aides productivity, but is utilized towards “work destruction” – elimination of work that is currently performed through a human interface.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using data from connected thermostats to track large power outages in the United States

The detection of power outages is an essential activity for electric utilities. A large, national dataset of Internet-connected thermostats was used to explore and illustrate the ability of Internet-connected devices to geospatially track outages caused by hurricanes and other major weather events. The method was applied to nine major outage events, including hurricanes and windstorms. In one event, Hurricane Irma, a network of about 1000 thermostats provided quantitatively similar results to detailed utility data with respect to the number of homes without power and identification of the most severely affected regions. The method generated regionally uniform outage data that would give emergency authorities additional visibility into the scope and magnitude of outages. The network of thermostat-sensors also made it possible to calculate a higher resolution version of outage duration (or SAIDI) at a level of customer-level visibility that was not previously available.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hurricane-induced power outage risk under climate change is primarily driven by the uncertainty in projections of future hurricane frequency

Nine in ten major outages in the US have been caused by hurricanes. Long-term outage risk is a function of climate change-triggered shifts in hurricane frequency and intensity; yet projections of both remain highly uncertain. However, outage risk models do not account for the epistemic uncertainties in physics-based hurricane projections under climate change, largely due to the extreme computational complexity. Instead they use simple probabilistic assumptions to model such uncertainties. Here, we propose a transparent and efficient framework to, for the first time, bridge the physics-based hurricane projections and intricate outage risk models. We find that uncertainty in projections of the frequency of weaker storms explains over 95% of the uncertainty in outage projections; thus, reducing this uncertainty will greatly improve outage risk management. We also show that the expected annual fraction of affected customers exhibits large variances, warranting the adoption of robust resilience investment strategies and climate-informed regulatory frameworks.

54 ENVIRONMENTAL SCIENCES↗

Studying information recurrence, gatekeeping, and the role of communities during internet outages in Venezuela

Many authoritarian regimes have taken to censoring internet access in order to stop the spread of misinformation, restrict citizens from discussing certain topics, and prevent mobilization, among other reasons. There are several theories about the effectiveness of censorship. Some suggest that censorship will effectively limit the flow of information, whereas others predict that a backlash will form, resulting in ultimately more discussion about the topic. In this work, we analyze the role of communities and gatekeepers during multiple internet outages in Venezuela in January 2019. First, we measure how critical information (e.g., entities and hashtags) spreads during outages focusing on information recurrence and burstiness within and across language and location communities. We discover that information bursts tend to cross both language and location community boundaries rather than being limited to a single community during several outages. Then we identify users who play central roles and propose a novel method to detect gatekeepers—users who prevent critical information from spreading across communities during outages. We show that bilingual and English-speaking users play more central roles compared to Spanish-speaking users, but users inside and outside Venezuela have similar distribution of centrality. Finally, we measure the differences in social network structure before and after each outage event and discuss its effect on how information spreads. We find that with each outage event social connections tend to get less connected with higher mean shortest path, indicating that the effect of censorship makes it harder for information to spread.

97 MATHEMATICS AND COMPUTING↗

Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the line outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗